• Title/Summary/Keyword: 초음파 검사법

Search Result 402, Processing Time 0.029 seconds

Analysis and Simulation of Ultrasonic Wave Propagation and Scattering in Unidirectional Fiber Composites (단일방향 섬유 복합재료 내의 초음파 전파 및 산란 현상의 해석과 시뮬레이션)

  • Lee, Choon-Jae;Yim, Hyun-June
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.3
    • /
    • pp.269-276
    • /
    • 2001
  • Ultrasonic testing of composite materials is much more difficult than that of isotropic materials, because of the beam skew phenomenon caused by their elastic anisotropy. An established analytical method exists for elastic wave propagation in anisotropic media as a result of previous research efforts. Yet, due to the complexity of the analytical method, solution of real problems must resort to the numerical method. In this work, analytical solutions have first been obtained for the wavefield due to a point source in a unidirectional fiber-reinforced composite, which may be modeled as transversely isotropic. Then, the corresponding numerical solutions have been obtained using the mass-spring lattice model(MSLM). The two solutions have agreed well with each other. Other problems such as reflection from free boundaries and scattering from cracks have also been solved numerically, and the results have been investigated from the viewpoint of wave mechanics. The numerical model whose validity has been confirmed by this work will be of great use in simulating ultrasonic testing of composite materials.

  • PDF

Reliability Evaluation of Semiconductor using Ultrasound (초음파를 이용한 반도체의 신뢰성 평가)

  • Jang, Hyo-Seong;Ha, Job;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.6
    • /
    • pp.598-606
    • /
    • 2001
  • Recently, semiconductor packages trend to be thinner, which makes difficult to detect defects therein. A preconditioning test is generally performed to evaluate the reliability of semiconductor packages. The test procedure includes two scanning acoustic microscope (SAM) tests at the beginning and end of the entire test, in order to help detect physical defects such as delaminations and package cracks. In particular, of primary concern are package cracks and delaminations caused by moisture absorbed under ambient conditions. This paper discusses the failure mechanism associated with the moisture absorbed and encapsulated in semiconductors, and the use SAM to detect failures such as tracks and delaminations grown during the preconditioning test.

  • PDF

Comparative Analysis of Liver Ultrasound and Fibroscan Tests for Fatty Liver Diagnosis (지방간 진단을 위한 간 초음파와 Fibroscan 검사법의 비교 분석)

  • Kim, Keun-Hee;Ji, Tae-Jeong;Kim, Hyeon-Jin
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.265-271
    • /
    • 2022
  • This study retrospectively analyzed the test results of 441 patients who visited Hospital I in Busan from October 2021 to December 2021 and conducted both mid-term ultrasound and fibroscan tests. The purpose of the study was to investigate the usefulness of fibroscan in inter-fat evaluation by conducting correlation analysis and chi-squared test of inter-fat evaluation using liver ultrasound and fibroscan. As a result of analyzing the correlation between the fatty liver reading result of abdominal ultrasound and Fibroscan UAP, the correlation was found to be r=0.600 and p=0.000. In the inter-provincial evaluation, Fibroscan showed high validity in predicting objective results using inter-provincial values.

A Study on the Minimum Number of Rebound Number Test and Pulse Velocity Method for Estimating Compressive Strength of Concrete (콘크리트 압축강도 추정을 위한 반발도법과 초음파속도법의 최소시험횟수에 관한 연구)

  • Lee Mun-Hwan;Choi Chang-Woo
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.6 s.84
    • /
    • pp.833-840
    • /
    • 2004
  • Among non-destructive tests for compressive strength, rebound number test and pulse velocity test are the most widely used methods. However, the non-destructive tests mostly used in Korea was developed by foreign country. Therefore, it is unreasonable to directly apply them to concrete structures in Korea. In accordance with the suggestion of Institute of Architecture in Japan for rebound number test, a compressive strength is calculated by the mean value of 20 hit points without being considered standard deviation. Furthermore, there is no regulation on the number of measurements required for measuring compressive strength by pulse velocity test. This study, therefore, reviewed the rebound number test and pulse velocity test by chi-square, and suggested the minimum number of each test. As a result, the minimum number that falls within range of reliability for rebound number test and pulse velocity test are 11 and 7, respectively. If abnormal values are processed as missing and test groups are assumed to be arrayed in cross by considering changes in quality of actual concrete structures, 20 times and 9 times are appropriate for rebound number test and pulse velocity test, respectively.

Simultaneous Measurement of Ultrasonic Velocity and Thickness of Isotropic and Homogeneous Solids Using Two Transducers (두개의 탐촉자를 사용한 등방성 균일 고체의 초음파 속도 및 두께 동시 측정법)

  • Lee, Jeong-Ki;Kwon, Jin-O;Kim, Young-H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.5
    • /
    • pp.363-368
    • /
    • 1999
  • Ultrasonic pulse-echo methods measuring the transit time through specimens have been widely used in determination of ultrasonic velocity and thickness of specimens. Usually, to determine the velocity of the ultrasonic. the transit time of the ultrasonic pulse through specimen is measured by using the ultrasonic measuring equipment such as the oscilloscope including ultrasonic pulser/receiver and the thickness of the specimen is measured by using the length measuring instrument such as micrometer or vernier calipers etc., i. e. each parameter is measured by using each measuring method. In the case of the measuring the thickness of a specimen by using the ultrasonics. the ultrasonic equipments, which measure the thickness, such as the ultrasonic thickness gauge must be calibrated by using the reference block of which the ultrasonic velocity is known beforehand. In the present work, we proposed a new method for simultaneous measurement of ultrasonic velocity and thickness without reference blocks. Experimental results for several specimens show that proposed method have good agreements with those by traditional ultrasonic method.

  • PDF

Simulations for Internal Defect Inspection Using Laser Generated Ultrasonic Wave in Ablation Regime (어블레이션 영역 레이저 초음파의 시뮬레이션과 내부결함 검사)

  • Kim, Jin-Gyum;Choi, Sungho;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.3
    • /
    • pp.226-232
    • /
    • 2014
  • In the present study, the characteristics of laser ultrasound in the ablation regime are investigated using simulations and experiments. The laser ultrasonic technique has been recognized as a noncontact method in the field of nondestructive tests (NDTs). In hostile environments (such as hot temperatures), this method has various advantages over the conventional contact ultrasonic method. In particular, in the ablation regime, the laser ultrasonic technique is suitable for inspecting internal defects because of the high amplitude and directivity of the longitudinal wave. In this paper, a simulation model for laser ultrasound in the ablation regime was developed. This model was subsequently applied to a defective specimen using the B-scan method to locate defects. Finally, we performed an experimental test to verify the simulation results. Consequently, the simulation demonstrated good agreement with the experimental test.

A novel approach to the classification of ultrasonic NDE signals using the Expectation Maximization(EM) and Least Mean Square(LMS) algorithms (Expectation Maximization (EM)과 Least Mean Square(LMS) algorithm을 이용하여 초음파 비파괴검사 신호의 분류를 하기 위한 새로운 접근법)

  • Daewon Kim
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.4 no.1
    • /
    • pp.15-26
    • /
    • 2003
  • Ultrasonic inspection methods are widely used for detecting flaws in materials. The signal analysis step plays a crucial part in the data interpretation process. A number of signal processing methods have been proposed to classify ultrasonic flaw signals. One of the more popular methods involves the extraction of an appropriate set of features followed by the use of a neural network for the classification of the signals in the feature space. This paper describes an alternative approach which uses the least mean square (LMS) method and expectation maximization (EM) algorithm with the model based deconvolution which is employed for classifying nondestructive evaluation (NDE) signals from steam generator tubes in a nuclear power plant. The signals due to cracks and deposits are not significantly different. These signals must be discriminated to prevent from happening a huge disaster such as contamination of water or explosion. A model based deconvolution has been described to facilitate comparison of classification results. The method uses the space alternating generalized expectation maximization (SAGE) algorithm In conjunction with the Newton-Raphson method which uses the Hessian parameter resulting in fast convergence to estimate the time of flight and the distance between the tube wall and the ultrasonic sensor Results using these schemes for the classification of ultrasonic signals from cracks and deposits within steam generator tubes are presented and showed a reasonable performances.

  • PDF

Design and Implementation of Mobile ]Respiration Detection Diagnostic System using Ultrasound Sensing Method fficient Multicasting Environment (초음파 센싱 방식을 이용한 이동형 호흡량 측정 진단기의 설계 및 구현)

  • 김동학;김영길
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.2
    • /
    • pp.509-515
    • /
    • 2004
  • Pulmonary function tests are widely used to diagnose and determine patients' therapy in clinic. And it was also applied in the research of the physiology and dynamics for lung disease. Among the pulmonary function tests, spirometry is the most easy and economic test. Spirometers are medical instruments that measure the instantaneous rate of volume flow of respired Bas. The mechanical spirometer was mostly used in the past. Up to the present, the most popular method of spirometer is the differential pressure technique with which change in the volume of flow are transferred to change in pressure. This kind of instrument suffers from several limitations, pressure drop, difficulty in maintenance and short period of calibration. Therefore, this study has begun to implement ultrasound spirometer, which is free of pressure loss and has wide range, focusing on the flow measurement technique and diagnostic algorithm.

Measurements of Ultrasonic Velocity and Attenuation by Signal Processing Techniques in Time and Frequency Domains (시간 및 주파수 영역에서의 신호 처리 기술에 의한 초음파 속도와 감쇠의 측정)

  • Jang, Young-Su;Kim, Jin-Ho;Jeong, Hyun-Jo;Nam, Young-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.2
    • /
    • pp.118-128
    • /
    • 1999
  • There are many ultrasonic measurement methods that are used in nondestructive testing applications. Some typical applications include material property determination, microstructural characterization. and flaw detection. Ultrasonic parameters such as velocity and attenuation are most commonly required in these applications. The accuracy and repeatability of testing results are dependent on both the hardware used to generate and receive the ultrasonic waves and on the analysis software for calculating these parameters. In this study, five analysis algorithms were implemented on a computer for measuring wave speed in a pulse echo. immersion testing configuration. In velocity measurements comparisons were made between the overlap. cross-correlation. Fourier transform. Hilbert transform, wavelet transform algorithms. Velocity measurement was applied to an isotropic steel sample using the five analysis algorithms. Frequency-dependent phase/group velocity and attenuation were also measured using the Fourier transform and wavelet transform algorithms on a composite laminate containing voids.

  • PDF