• Title/Summary/Keyword: 초음파유속계

Search Result 48, Processing Time 0.028 seconds

Analysis of Tidal Effect in Hangang Bridge by Automatic Discharge Measurement (자동유량측정에 의한 한강대교 조석영향 분석)

  • Lee, Min-Ho;Kim, Chang-Wan;Yoo, Dong-Hoon
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.7
    • /
    • pp.513-523
    • /
    • 2009
  • The measuring point of the Hangang Bridge affected by tide has some special topographic characteristics due to Nodle Island. Furthermore the submerged weirs located on the upstream and downstream. Therefore flow is separated and joined by Nodle Island. Discharge measurement at the point of the Hangang Bridge is very important, because Hangang Bridge is key station in managing the discharge and flood forecasting. In the past, it was too difficult to measure discharge in tidal conditions. HRFCO(Han River Flood Control Office) installed automatic discharge measurement facilities for solving this problem. Measuring equipments operates and measures discharge every 10 minutes at 2 points(southern and northern section close to Nodle Island), and calculates flow discharge using Chiu's velocity law(Chiu, 1988). In order to verify the results of automatic discharge measurements, manual discharge measurements were carried out by ADCP. In addition, the monthly discharge were also compared.

Discharge Measurement Using ADCP Stationary Method (ADCP 정지측정법을 이용한 유량측정)

  • Kim, Yong-Jeon;Lee, Chan-Joo;Yoo, Min-Wook;Kim, Dong-Gu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.462-466
    • /
    • 2010
  • 하천을 횡단하며 유속을 측정하는 ADCP를 유속면적법과 같이 정해진 측선에 정지시켜 연직 유속을 측정하고 이를 단면적과 곱하여 유량을 산정하는 방법이 ADCP 정지측정법(Stationary Method)이다. 이 방법은 이미 괴산댐 하류에 적용되어 정지측정법 측정유량이 댐방류량 대비 평균 4%의 상대오차를 보여 효율성이 입증되었다. 본 연구에서는 일반 자연하천인 임진강 적성지점에 정지측정법을 적용하여 넓은 범위의 수위, 유량 변화에 대한 적용 가능성을 점검하였다. 또한 홍수기 널리 사용되는 측정방법인 부자법의 검증 수단으로서 적용 여부를 검토하였다. 2009년 7월부터 8월까지 총 26회 실시한 정지측정법은 1,046~9,663 $m^3/s$의 측정 유량 범위를 보였다. 측정기간 동안 단면평균 유속은 1.3~3.0m/s였으며, 측정 최대유속은 4.0m/s였다. 측정 소요시간은 23~46분으로 평균 35분 소요되었다. 같은 지점에서 실시한 봉부자법 측정이 평균 29분 소요한 것과 큰 차이가 없었다. ADCP를 이용한 정지측정법은 제조사에서 제공하는 전용 프로그램으로 측정과 동시에 수위, 단면 연직 유속 등의 확인이 가능하며, ISO 기준 불확실도 계산 기능을 포함한다. 대하천인 임진강 적성지점에서 실시한 ADCP 정지측정법은 봉부자법과 비슷한 측정시간이 소요되며 넓은 수위, 유량범위에서 측정이 가능한 방법으로 판단되었다. 기존의 유량측정이 수위, 유량에 따라 방법이 달라지고 측정 장비의 제약이 따르는 것에 반해 ADCP 정지측정법은 보다 넓은 수위, 유량 범위에서 적용이 가능하다. 즉, ADCP 정지 측정법은 평저수시뿐만 아니라 홍수시에도 유량 측정 가능한 방법이기 때문에 봉부자법 또는 초음파표면유속계와 같이 홍수시 사용되는 측정방법의 검증 수단으로서도 활용 가능할 것으로 판단된다.

  • PDF

Applicability Evaluation of Using Logarithmic velocity law for Assessing Local Shear Stress in Straight and Meandering River Channel (직선 및 사행 하천에서의 대수법칙를 이용한 국부 소류력 산정 적용성 검토)

  • Kim, Jong Min;Kim, Dong Su;Son, Geun Soo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.172-172
    • /
    • 2015
  • 하천에서 발생하는 소류력은 하상 변동을 발생시키기 때문에 주변 구조물이나 하천의 흐름특성 등을 변화시키게 되며, 유사이송, 침식 및 퇴적, 유동해석 등에 매우 중요한 하천 계수이다. 하천에서 소류력의 직접 측정은 매우 어려워 직접 측정 대신 하천경사 및 동수반경을 기반한 단면 평균소류력 산정 공식을 일반적으로 이용한다. 그러나, 이러한 방식은 상세한 유사이송, 세굴 등의 해석에는 한계가 있기 때문에 국부적인 소류력이 필요하다. 실내 실험에서는 프레스톤게이지를 활용한 직접 측정이나, 난류측정을 통한 레이놀즈 분포를 외삽하여 단면에서 국부적인 소류력을 측정하는 방식이 사용되어 왔다. 반면, 실제 하천에서는 국부 소류력 직접측정 및 난류 산정이 거의 불가능하거나 비효율적이므로 대안으로 하천의 연직유속분포에 대수분포를 적용하여 소류력을 추정하는 간접적인 방법이 제시되어 왔다. 일부 실내실험에서 대수법칙을 통한 소류력 산정 방식은 직접 측정을 통해 검증한 바가 있으나 실제 하천은 난류의 공간 시간적 스케일이 실내 규모와 상이하여 국부 소류력에 영향을 미칠 수 있어 이러한 검증결과를 현장 적용하기에는 한계가 있다. 본 연구에서는 실제 규모 하천에서 대수법칙을 활용한 국부 소류력 산정 결과와 레이놀즈 응력의 연직분포 측정을 통해 산정한 값과 비교하여 대수법칙 활용 소류력 산정 방식의 적용성을 검토하였다. 실험은 중소규모의 하천을 재현한 한국건설기술연구원 안동하천실험센터 직선(A1) 및 사행(A2) 하천의 유속측정을 수행하였으며, 유속 측정에는 정밀도가 높으나 실내에서 주로 사용된 초음파지점유속계(Micro ADV)를 현장에 설치하여 사용하였다. ADV의 관측 시간은 90초이며, 직선수로에서는 횡방향으로 25 cm 간격, 수심방향으로는 5 ~ 10 cm 간격으로 측정하였고, 사행수로는 횡방향으로 50 cm 간격, 수심방향 5 ~ 10 cm 간격으로 측정을 수행하였다. 실험결과 대수법칙과 레이놀즈 분포로부터 산정된 국부 소류력은 사행과 직선 모두 상당한 이격을 보였다.

  • PDF

Assessment of Uncertainty for Discharge Measurement using Velocity-Area method (유속-면적법으로 측정된 유량에 대한 측정 불확도 평가)

  • Kim, Jongmin;Kim, Dongsu;Kim, Seojun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.104-104
    • /
    • 2016
  • 소규모 하천에서의 평수기 유량 측정은 일반적으로 지점식 초음파 유속계, 프로펠러 유속계 등을 활용해 도섭법으로 측정된 유속 측정성과를 기반하여 유속-면적법으로 산정된다. 유속-면적법으로 측정된 유량 측정 성과는 횡방향 측선의 수, 수심방향 측점의 수, 측정 시간, 수심 등 제반 측정 인자에 의해 영향을 받고 유량 불확도는 각 인자 별 오차에 영향을 받는다. ISO 748 (2007)과 ISO 1088 (2007)은 유속-면적법 적용방법, 현장 측정 가이드라인, 불확도 인자 별 적용 요건에 따른 오차, 최종 유량 불확도 산정 기법을 제시하였다. 따라서, 국내외 유량조사 기관에서는 유속면적법을 적용할 경우, ISO에서 제시된 인자 별 오차 및 유량 불확도 산정 기법을 기반으로 유량 불확도를 산정해왔다. ISO 748과 1088은 다양한 규모의 실제 하천에서 관측된 자료를 기반으로 횡방향 측선 수, 수심방향 측점 수 (2점법, 3점법 등), 측정 시간 등과 관련된 인자 별 오차를 표로 상세하게 제시하였고 실무에서는 별도 추가 검증없이 사용해 왔다. 그러나, ISO에서 유속-면적법 유량 측정 불확도를 평가하기 위해 사용된 측정자료는 유량을 제어하기 힘들고 유속 측정 상황이 유출 조건 별로 상이한 현장 자료를 기반으로 하였고, 상대적으로 정확도가 낮은 프로펠러유속계를 기반으로 1960년대에 관측된 자료들을 주로 활용하여 도출되었다. 따라서, 본 연구에서는 기존 ISO에서 제시한 유속-면적법에 필요한 인자들의 오차를 정밀 실규모 실험을 통해 재산정하여 기존 ISO 748과 1088에서 제시한 인자별 오차의 적정성을 검증하고자 하였다. 이를 위해 흐름을 안정적으로 통제할 수 있는 건설기술연구원 안동 하천실험센터의 완경사수로(A2)에서 정상상태의 폭 7m, 수심 1m, 유속 약 1m/s의 흐름을 유지한 후, 유속 측정 정확도가 우수한 micro-ADV를 활용하여 공간적으로 매우 정밀하게 유속을 측정하고, 수심은 Total Station을 기반으로 흐름 발생 전에 정밀 측정하였다. 오차 분석 결과, ISO 규정에서 제시한 오차와 본 실험의 결과로 도출된 인자들의 오차는 상당한 차이를 보였다. 따라서, 본 연구 결과로 도출된 유속-면적법의 인자 별 오차는 실험이 수행된 소하천 규모의 하천에서 도섭법으로 산정된 유량의 불확도를 평가할 경우에 활용될 것으로 기대된다.

  • PDF

A Study on Field Experiment and Numerical Modeling for Efficiency Analysis of Selective Withdrawal in Imha Reservoir (임하호 선택취수 효과분석을 위한 현장실험 및 수치해석 연구)

  • Kim, Tae Won;Kim, Young Do;Yi, Yong-Kon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.2B
    • /
    • pp.113-121
    • /
    • 2012
  • When a heavy rain brings flooding, a high turbid water is flowing into a reservoir. In this study, the effectiveness of the intake structures for the selective withdrawal from the various levels of a stratified reservoir was evaluated by the field experiments and the numerical modeling of the three-dimensional approaching flows. The temperature, the turbidity, and the velocity fields for the selective withdrawal were measured using both YSI6600EDS and YSI6600ADV, respectively. A threedimensional model, FLOW-3D, was used to predict the performance of the intake tower in Imha reservoir. The comparisons of the vertical velocity field showed a good agreement with the field measurements. The efficiency of the turbid-water elimination of the selective withdrawal method from low levels was higher up to 46% than that of the surface withdrawal. From the analysis of the numerical simulation, the efficiency of turbidity elimination increased by 10% for the selective withdrawal from middle levels, and by 30% from low levels. These results showed that the selective withdrawals from middle and low levels are more effective than the surface-water intake. The similar results were obtained by the one-dimensional model, SELECT, which is much more computationally time-efficient.

Feasibility Calculation of FaSTMECH for 2D Velocity Distribution Simulation in Meandering Channel (사행하천의 2차원 유속분포 모의를 위한 FaSTMECH 모형의 적용성 검토)

  • Son, Geunsoo;You, Hojun;Kim, Dongsu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.6
    • /
    • pp.1753-1764
    • /
    • 2014
  • Numerical flow simulation models in the riverine environments have been widely utilized for analyzing flow dynamics in various degrees in researches and practical applications. However, most of the simulated results have been validated based on the data from indoor experimental models or very limited in-situ measurements. Therefore, it has been required to more accurately validate the performance of the numerical models in terms of the detailed field observations. In particular, it was also hard to validate the performances of the existing numerical models in the real meandered river channels that encompass more sophisticated flow and geometric structures. Recently, advancements of the modern flow measuring instrumentations such as acoustic Doppler current profilers (ADCPs) enabled us to efficiently acquire the detailed flow field in the broad range of river channels, thus that it became to be possible to accurately validate any numerical models with the field observations. In this study, based on the detailed flow measurements in a actual meandered river channel using ADCP, we validated FaSTMECH model in iRIC in terms of water surface elevation, which is relatively new but began to get highlighted in the research areas. As the validation site, a meandering channel in River Experiment Center of KICT was chosen, which has 6.5 m of width, 0.38m of flow depth, 1.54 m3/s of flow discharge, 0.61 m/s of mean flow velocity, and 1.2 of sinuosity. As results, whereas the FaSTMECH precisely simulated water surface elevation, simulated velocity field in the bend did not match well with ADCP dataset.

Development of a method for diagnosing the severity of water stage-discharge hysteresis using water surface slope (수면경사활용 수위-유량 이력현상 현저성 진단기법 개발)

  • Kim, Kyungdong;Kim, Dongsu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.54-54
    • /
    • 2021
  • 최근 홍수파 또는 댐 및 보 등의 하천 구조물과, 본류와 지류의 합류로 인해 발생하는 배수영향 등으로 하천에 고리형 수위-유량관계의 이력현상이 발생하여, 수위-유량관계식으 신뢰도가 저하된다고 판단하여, 대하천 본류와 합류부 인근 지류에 초음파기반유속계(ADCP)의 측정결과를 지표로 활용하는 자동유량관측소가 현재 58개소가 구축되어 운용되고 있다. 그러나, 4대강 사업으로 다기능보의 설치 등으로 인해 하천의 수리학적 특성이 변동되었고, 지류에서 주로 운용하는 수위-유량관계 기반 유량관측소에 수문사상으로 인해 발생한 홍수파 또는 배수영향으로 인한 하천에 수위-유량관계의 이력현상이 발생할 경우, 지류 수위관측소를 자동유량관측소로 대체할 필요성이 제기되고 있다. 기존의 자동유량관측소의 경우 홍수량이 기준이하로 발생할 경우 수위-유량 관계식으로 대체하는 경우도 있지만, 적용기준이 명확하지 않다. 또한, 하천의 수위-유량관계의 이력현상이 발생했을 경우 수위-수면경사의 이력현상도 같이 발생하게 된다. 수면경사의 경우 기존 수위관측소로부터 수위 측정결과로부터 산정할 수 있기에, 수면경사로부터 하천의 이력현상 현저성을 산정할 경우 자동유량 장치를 활용하지 않고 이력현상 현저성 진단을 할 수있다. 따라서, 본 연구에서는 신규 자동유량장치 설치, 기존 수위관측소의 자동유량관측소대체, 자동유량관측소에서 수위-유량관계의 활용 기준 마련 등을 명확하게 판단하기 위해 상류에 위치한 수위관측소의 수위 측정으로부터 하천의 수면경사를 산정하고 수면경사를 활용하여 수위-유량관계 이력현상의 패턴을 분석하여 현저성을 진단하는 기법을 개발하고자 한다. 이를 위해, 다기능보 설치 및 지류-본류로 인한 지류하천의 배수영향과 홍수파에 의해 발생한 수위-유량관계의 이력현상를 다양한 수문사상에 대하여 분석 하였다. 분석방법으로는 대상유역으로 수위-유량관계의 이력현상이 발생하는 영산강유역에 위치한 남평교, 나주대교 두 지점을 선정하고 자동유량관측소 상류에 위치한 기존 수위관측소의 수위 측정값으로부터 하천의 수면경사를 산정하고 수위-유량관계와 수위-수면경사관계의 패턴을 분석하고, 수위-수면경사의 이력현상으로 부터 수위-유량관계 이력현상의 현저성을 진단하였다. 분석결과 각 수문사상마다 수위-유량관계의 최대이력범위와, 수위-수면경사의 최대이력범위를 각각 무차원화시켜 관계그래프를 산정하였다. 남평교의 경우 수위-유량관계의 이력현상이 현저히 나타남에도 불구하고 수위-수면경사의 이력범위는 거의 없었다. 나주대교의 경우 수위-유량관계와, 수위-수면경사관계 각각의 이력범위가 현저히 나타나 관계를 분석하기 용이하였다. 또한, 나주대교관측소지점의 분석을 통하여 수위-수면경사 이력범위의 유의 수준을 두어 일정 이력범위(20%)가 발생한 경우, 수위-유량관계의 이력현상이 현저함을 알 수 있었다. 이러한 결과를 바탕으로 20%이상의 이력범위를 수위-수면경사의 이력범위로부터 수위-유량관계의 현저성을 판단하는 기준으로 제안하였다.

  • PDF

Development of an anisotropic spatial interpolation method for velocity in meandering river channel (비등방성을 고려한 사행하천의 유속 공간보간기법 개발)

  • You, Hojun;Kim, Dongsu
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.7
    • /
    • pp.455-465
    • /
    • 2017
  • Understanding of the two-dimensional velocity field is crucial in terms of analyzing various hydrodynamic and fluvial processes in the riverine environments. Until recently, many numerical models have played major roles of providing such velocity field instead of in-situ flow measurements, because there were limitations in instruments and methodologies suitable for efficiently measuring in the broad range of river reaches. In the last decades, however, the advent of modernized instrumentations started to revolutionize the flow measurements. Among others, acoustic Doppler current profilers (ADCPs) became very promising especially for accurately assessing streamflow discharge, and they are also able to provide the detailed velocity field very efficiently. Thus it became possible to capture the velocity field only with field observations. Since most of ADCPs measurements have been mostly conducted in the cross-sectional lines despite their capabilities, it is still required to apply appropriate interpolation methods to obtain dense velocity field as likely as results from numerical simulations. However, anisotropic nature of the meandering river channel could have brought in the difficulties for applying simple spatial interpolation methods for handling dynamic flow velocity vector, since the flow direction continuously changes over the curvature of the channel shape. Without considering anisotropic characteristics in terms of the meandering, therefore, conventional interpolation methods such as IDW and Kriging possibly lead to erroneous results, when they dealt with velocity vectors in the meandering channel. Based on the consecutive ADCP cross-sectional measurements in the meandering river channel. For this purpose, the geographic coordinate with the measured ADCP velocity was converted from the conventional Cartesian coordinate (x, y) to a curvilinear coordinate (s, n). The results from application of A-VIM showed significant improvement in accuracy as much as 41.5% in RMSE.