• Title/Summary/Keyword: 초음파영상검사

Search Result 407, Processing Time 0.024 seconds

Application of Laser-based Ultrasonic Technique for Evaluation of Corrosion and Defects in Pipeline (배관부 부식 및 결함 평가를 위한 레이저 유도 초음파 적용 기술)

  • Choi, Sang-Woo;Lee, Joon-Hyun;Cho, Youn-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.2
    • /
    • pp.95-102
    • /
    • 2005
  • There are many tube and pipeline in nuclear power plant under high temperature and high pressure. Erosion and corrosion defects were expected on these tube and pipe-line by environmental and mechanical factors. These erosion and corrosion defects ran be evaluated by ultrasonic technique. In these study, Scanning Laser Source(SLS) technique was applied to detect defect and construct image. This technique also makes detection possible on rough and curved surfaces such as tube and pipe-line by scanning. Conventional ultrasonic scanning technique requires immersion of specimen or water jet for transferring ultrasonic wave between transducer and specimen. However, this SLS technique does not need contacting and couplant to generate surface wave and to get flaw images. Therefore, this SLS technique has several advantages, for complicated production inspection, non-contact, remote from specimen, and high resolution. In this study, SLS images were obtained with various conditions of generation laser ultrasound and receiving in order to enhance detectability of flaws on the tube. Stress corrosion cracks were produced on tube and images of stress corrosion cracks were constructed by using SLS technique.

Evaluation of Depth Penetration by Changing Image Parameters using Phantom on Ultrasound (의료용 초음파 영상에 영향을 미치는 Algorithm Parameters 변환으로 빔 투과 깊이 연구)

  • Lee Bo Sam;Lim Hyun Soo
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.30 no.1
    • /
    • pp.77-89
    • /
    • 2004
  • I. 목적 : 의료용 초음파 장비의 성능 관리 중 최적 화질의 기본이 되는 심부 투과 깊이에 대해 검증이 미흡한 장비 회사의 protocol setting 값이 현재 대부분의 병원에서 사용되고 있는 실정이다. 이러한 protocol에서 벗어나 국내 여러 모델의 장치에 공통적으로 환자 검사에 실제로 사용하고 있는 algorithm 인 parameters를 사용하여 초음파 영상에 영향을 미치는 빔 투과 깊이의 변화에 따른 최적영상을 평가하고자 한다. II.

  • PDF

PSNR Analysis of Ultrasound Images for Follow-up of Hepatocellular Carcinoma (간세포암 추적관찰 초음파영상의 PSNR 분석)

  • Lee, Junhaeng
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.5
    • /
    • pp.263-267
    • /
    • 2015
  • In this paper, a method was proposed for objective and scientific judgment on disease conditions that is currently relied on subjective judgment of ultrasound practitioners. In the proposed method, mean squared errors (MSE) in ultrasound images for follow-up of HCC patients were obtained and the Peak Signal to Noise Ratio(PSNR) of the ultrasound images was analyzed. According to the results of analysis, MSE and PSNR values changed over time. This is attributable to changes in ultrasound images resulting from increases in utrasonic echoes following the progression of HCC. The results of the present study can be used as a method for scientific and objective judgment in ultrasonic scan instead of current subjective judgment by practitioners.

Ultrasonography for Diagnosing Sports-Related Shoulder Pain (스포츠 관련 견관절 통증에서 초음파 영상 검사)

  • Song, Hyun Seok
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.5
    • /
    • pp.384-392
    • /
    • 2019
  • Ultrasonography is used for making the diagnosis and treatment decisions for those patients who complain of shoulder pain related with sports activity. Ultrasonography is especially helpful for diagnosing issues with the rotator cuff, the long head of biceps tendon and the acromio-clavicular joint. The medical decisions about shoulder pain can be promptly made when portable ultrasonography is used in the field of sports.

Reconstructing Flaw Image Using Dataset of Full Matrix Capture Technique (Full Matrix Capture 데이터를 이용한 균열 영상화)

  • Lee, Tae-Hun;Kim, Yong-Sik;Lee, Jeong-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.37 no.1
    • /
    • pp.13-20
    • /
    • 2017
  • A conventional phased array ultrasonic system offers the ability to steer an ultrasonic beam by applying independent time delays of individual elements in the array and produce an ultrasonic image. In contrast, full matrix capture (FMC) is a data acquisition process that collects a complete matrix of A-scans from every possible independent transmit-receive combination in a phased array transducer and makes it possible to reconstruct various images that cannot be produced by conventional phased array with the post processing as well as images equivalent to a conventional phased array image. In this paper, a basic algorithm based on the LLL mode total focusing method (TFM) that can image crack type flaws is described. And this technique was applied to reconstruct flaw images from the FMC dataset obtained from the experiments and ultrasonic simulation.

Diagnosis of Chronic Kidney Disease using Sonography (초음파 영상을 이용한 만성 콩팥병의 진단)

  • Ahn, Yu-Ji;Ye, Soo-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.3
    • /
    • pp.153-159
    • /
    • 2017
  • Chronic kidney disease can be treated if it is detected early, but as the disease progresses, it becomes impossible to recover. Finally, renal replacement therapy such as transplantation or dialysis should be used. Ultrasonography is used to diagnose kidney cancer, inflammatory disease, nodular disease, and chronic kidney disease. It is used to identify information about degree of inflammation using information such as kidney size, internal echo characteristics. Currently, the degree of disease in the clinic uses the value of glomerular filtration rate. However, even in ultrasound, changes in the degree of inflammation and disease can be observed. In this study, we used ultrasound images to quantify the changes in brightness, size, cortex, and subclinical changes of the kidney with progression of the disease, and compared them with the glomerular filtration rate used in clinical practice. In 105 cases, we performed 35 cases of normal kidney, 35 cases of early kidney disease, and 35 cases of terminal kidney. The brightness of the cortex of the image was obtained and the difference in brightness between the cortex and the proximal portion was obtained by the slope. The graph of the portion which was not smooth due to the ultrasonic characteristics was used as the function regrass. The size reduction was obtained from the original data. The results were as follows: It was proportional to the glomerular filtration rate. It is considered that the algorithm can be applied to the disease if the algorithm study continues.

Advances in Hardware of Ultrasonic Propagation Imaging System (초음파전파영상화 시스템 하드웨어 발전)

  • Jeong, Hyo-Mi;Lee, Jeong-Ryul;Park, Chan-Ik
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.2
    • /
    • pp.214-219
    • /
    • 2012
  • 초음파전파영상화(UPI) 시스템은 2007년에 첫 논문 발표를 통해 시스템 개발이 보고된 이후 소프트웨어 및 하드웨어적 측면에서 다양한 형태로 발전된 시스템의 개발이 이루어졌다. 본 기고에서는 기본 UPI 시스템, 섬유파트랜스듀서 UPI 시스템, 순수광학시스템으로서 광섬유 센서 UPI 시스템, 완전비접촉 시스템으로서의 공기정압압전센서 UPI 시스템 및 레이저도플러진동계 UPI 시스템, 장거리 UPI 시스템, 옥외 적용성에 필수적인 저온환경 UPI 시스템 등을 소개한다.

A New Health Care Policy in Korea Part 2: Expansion of Coverage by National Health Insurance on the Abdominal Ultrasound and MRI (새로운 건강보험 보장성 강화 대책 2부: 복부 초음파 및 MRI 급여 확대)

  • Min Jae Jang;Seong Jin Park
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.5
    • /
    • pp.1069-1082
    • /
    • 2020
  • Coverage by National Health Insurance (NHI) was expanded in the abdominal imaging area as follows: upper abdominal ultrasound on April 1, 2018, lower abdominal ultrasound on February 1, 2019, and abdominal MRI on November 1, 2019. Many patients can benefit from the expansion of NHI coverage. Newly included diseases for NHI coverage includes liver cirrhosis, gallbladder polyps, hepatic adenoma/dysplastic nodules, pancreatic cysts, autoimmune pancreatitis and bile duct stone disease. However, the expansion of coverage made each examination more complex, including indications, follow-up strategy, the number of examination per patients, the standard images to be acquired, and the standard forms of the radiological report. Therefore, more careful consideration is mandatory when an abdominal imaging examination is prescribed and conducted.

Painful Causes around Hip Joint and Evaluation using Ultrasonography (고관절 주위 통증의 원인과 초음파적 진단)

  • Han, Kye Young
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.2 no.1
    • /
    • pp.45-52
    • /
    • 2009
  • Simple radiography, CT and MRI were used for the diagnosis of the hip disease. However ultrasonography could be a good diagnostic tool for the lesion of tendons and bursae. Another advantage of ultrasonography is its usefulness for the follow-up of these lesions. Nowadays hip ultrasonography expanded the horizon to the follow-up study of total hip arthroplasty. However, the limitation of ultrasonography is that there is disparity in results according to the physician's experiences. In this article ultrasonographic findings of normal structures and pathologic lesions of the hip joint are introduced and explained briefly.

  • PDF

Extraction of Transverse Abdominis Muscle form Ultrasonographic Images (초음파 영상에서 복횡근 근육 추출)

  • Kim, Kwang-Baek
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.3
    • /
    • pp.341-346
    • /
    • 2012
  • In rehabilitation where ultrasonographic diagnosis is not popular, it could be subjective by medical expert's experience. Thus, it is necessary to develop an objective automative procedure in ultrasonic image analysis. A disadvantage of existing automative analytic procedure in musculoskeletal system is to designate an incorrect muscle area when the figure of fascia is vague. In this study, we propose a new procedure to extract more accurate muscle area in abdomen ultrasonic image for that purpose. After removing unnecessary noise from input image, we apply End-in Search algorithm to enhance the contrast between fascia and muscle area. Then after extracting initial muscle area by Up-Down search, we trace the fascia area with a mask based on morphological and directional information. By this tracing of mask movements, we can emphasize the fascia area to extract more accurate muscle area in result. This new procedure is proven to be more effective than existing methods in experiment using convex ultrasound images that are used in real world rehabilitation diagnosis.