• Title/Summary/Keyword: 초음파신호

Search Result 683, Processing Time 0.028 seconds

Locating Particle by Ultrasonic Signal and Partial Discharge Signal Pattern in GIS (초음파 신호와 부분방전 신호의 패턴에 의한 GIS내 파티클 위치 추정)

  • 곽희로;이동준
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.5
    • /
    • pp.12-18
    • /
    • 2000
  • This paper describes the analysis of ultrasonic signal and partial discharge(PD) signal patterns for each location of particle in GIS. The characteristics of the ultrasonic signal and PD signal patterns for each location were as follows; in case of particle on the electrode, large ultrasonic signals and large PD signals occurred in positive half-cycle periodically; in case of particle on the spacer, ultrasonic signals and large PD signals occurred in negative half-cycle periodically; in case of the free moving particle, ultrasonic signals and large PD signals occurred by collision non-periodically. As a result, it was confirmed that particle in GIS could be located by the comparison and analysis of ultrasonic signal and PD signal patterns.

  • PDF

Speech synthesis using acoustic Doppler signal (초음파 도플러 신호를 이용한 음성 합성)

  • Lee, Ki-Seung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.2
    • /
    • pp.134-142
    • /
    • 2016
  • In this paper, a method synthesizing speech signal using the 40 kHz ultrasonic signals reflected from the articulatory muscles was introduced and performance was evaluated. When the ultrasound signals are radiated to articulating face, the Doppler effects caused by movements of lips, jaw, and chin observed. The signals that have different frequencies from that of the transmitted signals are found in the received signals. These ADS (Acoustic-Doppler Signals) were used for estimating of the speech parameters in this study. Prior to synthesizing speech signal, a quantitative correlation analysis between ADS and speech signals was carried out on each frequency bin. According to the results, the feasibility of the ADS-based speech synthesis was validated. ADS-to-speech transformation was achieved by the joint Gaussian mixture model-based conversion rules. The experimental results from the 5 subjects showed that filter bank energy and LPC (Linear Predictive Coefficient) cepstrum coefficients are the optimal features for ADS, and speech, respectively. In the subjective evaluation where synthesized speech signals were obtained using the excitation sources extracted from original speech signals, it was confirmed that the ADS-to-speech conversion method yielded 72.2 % average recognition rates.

Measurement of firmness in apples using ultrasonic techniques( I ) -Ultrasonic characteristics of the apple according to the storage period- (초음파를 이용한 사과의 경도측정( I ) -저장기간에 따른 사과의 초음파 특성-)

  • Kim, M. S.;Seo, R.;Kim, K. B.;Jung, H. M.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.464-470
    • /
    • 2002
  • 본 연구에서는 초음파를 사과의 비파괴 품질판정에 이용하기 위한 기초 연구로서 사과 표면에 입사, 반사되는 초음파 신호를 계측 및 분석하기 위한 시스템을 구축하고 저장기간에 따른 사과의 초음파 특성을 계측하였으며, 그 결론은 다음과 같다. 1. 구성된 비 접촉식 초음파 장치를 이용하여 전압-시간 그래프에서 전압의 진폭(PTP)값을 구하였고 신호처리용 프로그램을 이용하여 획득한 신호를 주파수 영역에서 분석하여 피크주파수, 영역별 에너지 밀도함수 등을 구하였다. 2. 사과의 초음파 특성을 분석한 결과 사과의 저장기간은 초음파 응답신호의 진폭(PTP) 및 제 3영역 에너지 스펙트럼 밀도함수와 높은 상관성이 있는 것으로 나타났다. 3. 초음파를 농산물의 비파괴 품질판정에 적용시 문제가 되고 지는 센서와 시료와의 접촉응력에 의한 응답신호의 변형에 의한 문제를 해결하고자 비 접촉식 센서를 사용하였으며, 실제 농산물에 적용이 가능한 것으로 판단되었다.

  • PDF

Removal Method of Signal Interference between Ultrasound Sensors (초음파 센서 간 신호 간섭 제거 방법)

  • Im, Hyungchul;Lee, Seongsoo
    • Journal of IKEEE
    • /
    • v.25 no.4
    • /
    • pp.584-590
    • /
    • 2021
  • This paper proposes a removal method of signal interference between ultrasound sensors where ghost signals due to interference are excluded and correct signal is recognized in distance mensurement using ultrasound sensors. The proposed method detects and excludes ghost signals when previous measured distance is compared to current measured distance and the distance difference exceeds a threshold. The threshold is fixed in conventional methods, so ghost signals cannot be correctly excluded when ultrasound sensor or target object move rapidly. On the contrary, to improve accuracy, the threshold is not fixed in the proposed method, and the threshold is adpatively determined based on the relative velocity when ultrasound sensor or target object move. Experiments of distance measurement with ultrasound signal interference are carried out where multiple ultrasound sensors of same type are exploited with maximum interference, and the results show that the proposed method efficiently exclude ghost signals.

Preliminary Experiment for Analysis of Guided Wave Behaviors in Buried Steel Pipes (지반에 매립된 배관에서의 유도초음파 거동 해석을 위한 기초 실험)

  • Lee, Ju-Won;Shin, Sung-Woo;Na, Won-Bae;Kim, Jae-Min;Kim, Young-Sang
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.673-675
    • /
    • 2011
  • 본 연구에서는 매립 구간의 길이가 유도초음파 신호 강도에 미치는 영향을 분석하였다. 유도초음파 모드 해석을 통해 가진 모드와 주파수를 결정하였으며, 유도초음파의 가진 및 수진은 경사각 입사 방식의 Pitch-Catch 법을 이용하였다. 또한, 비 매립된 배관에서 유도초음파 신호를 획득하여, 이를 기준으로 매립된 배관에서 획득한 유도초음파 신호를 분석하였다. 실험 결과 매립 구간의 길이가 유도초음파의 신호 강도에 매우 큰 영향을 미칠 뿐만 아니라, 매립 구간의 길이와 신호 강도의 변화가 선형 비례적인 관계를 보이지 않는다는 것을 확인할 수 있었다.

  • PDF

Determination of the Optimum-Bandwidth of Chirp-Signal for Pulse Compression Technique (펄스압축 기술을 위한 chirp 신호의 최적대역폭 결정)

  • Ko, Dae-Sik;Moon, Gun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.5-9
    • /
    • 1997
  • In this paper, when we use the chirp signal as input signal of ultrasonic signal system the technique for determining the bandwidth of the chirp signal that maximizes the amplitude of the compressed ultrasonic echo signal has been studied. In ultrasonic signal processing systems, the signal-to-noise ratio of the echo signal can be too low due to damping and scattering of the ultrasonic wave during transmission. Method of pulse compression using chirp signal is a means to increase the signal-to-noise ratio in ultrasonic pulse-echo systems. Simulation and experimental results showed that the output signal of ultrasonic system was increased by pulse width of chirp signal and the optimum-bandwidth of the chirp signal was 1.15 times larger than the bandwidth of the ultrasonic system.

  • PDF

Estimating the Location of Partial Discharge Signals (부분 방전 신호의 위치 추정)

  • 유치형;정찬수;김재철
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.5
    • /
    • pp.80-85
    • /
    • 1997
  • Preventive diagnosis technique of power transforms is very important for highly reliable operation of power systems, and especially that of online transformer is needed in view of economy. Acoustic methods for partial discharge points have been studied abroad since 1960's in earnest. Electric-ultrasonic locating method by which partial discharges are found through detecting the electric and ultrasonic signal generated in partial discharge and ultrasonic-ultrasonic locating method by which partial discharges are found through detecting two ultrasonic signal with two ultrasonic sensor have been researched in our country. By using this ultrasonic-ultrasonic locating method, it was proposed of graphical determination technique of partial discharge points one dimension, two dimension, three dimension. But in locating partial discharges, they have assumed that the number of signal origin is one. So in this study we suggests a method of locating and knowing the number of signal origins when there are several origins by using ultrasonic-ultrasonic method.

  • PDF

Development of the On-line Ultrasonic Detecter for Transformer Applied Noise Rejection Algorithm (노이즈 제거 알고리즘을 적용한 변압기 초음파 상시 측정장치 개발)

  • 권동진;진상범;곽희로
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.4
    • /
    • pp.80-91
    • /
    • 2002
  • An on-line ultrasonic detector was developed to continuously monitor the ultrasonic signal due to partial discharge in transformer in service. The on-line ultrasonic detector has a band-pass filter designed to measure only the frequencies from 50 to 300[㎑] of ultrasonic signal, to remove electrical and mechanical noises from outside of the transformer, and tlle ultrasonic sensor contains a pre-amplifier with 60[dB] gain. The ultrasonic signal discrimination algorithm which discriminates the ultrasonic signal duration was developed to remove the ultrasonic signal due to OLTC operation having similar characteristics to those due to partial discharge. The reliability of the on-line ultrasonic detector developed in this study was convinced of measurement the ultrasonic signals from the model. transformer in laboratory and transformer in service.

A novel approach to the classification of ultrasonic NDE signals using the Expectation Maximization(EM) and Least Mean Square(LMS) algorithms (Expectation Maximization (EM)과 Least Mean Square(LMS) algorithm을 이용하여 초음파 비파괴검사 신호의 분류를 하기 위한 새로운 접근법)

  • Daewon Kim
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.4 no.1
    • /
    • pp.15-26
    • /
    • 2003
  • Ultrasonic inspection methods are widely used for detecting flaws in materials. The signal analysis step plays a crucial part in the data interpretation process. A number of signal processing methods have been proposed to classify ultrasonic flaw signals. One of the more popular methods involves the extraction of an appropriate set of features followed by the use of a neural network for the classification of the signals in the feature space. This paper describes an alternative approach which uses the least mean square (LMS) method and expectation maximization (EM) algorithm with the model based deconvolution which is employed for classifying nondestructive evaluation (NDE) signals from steam generator tubes in a nuclear power plant. The signals due to cracks and deposits are not significantly different. These signals must be discriminated to prevent from happening a huge disaster such as contamination of water or explosion. A model based deconvolution has been described to facilitate comparison of classification results. The method uses the space alternating generalized expectation maximization (SAGE) algorithm In conjunction with the Newton-Raphson method which uses the Hessian parameter resulting in fast convergence to estimate the time of flight and the distance between the tube wall and the ultrasonic sensor Results using these schemes for the classification of ultrasonic signals from cracks and deposits within steam generator tubes are presented and showed a reasonable performances.

  • PDF

Thickness Measurement by Using Cepstrum Ultrasonic Signal Processing (켑스트럼 초음파 신호 처리를 이용한 두께 측정)

  • Choi, Young-Chul;Park, Jong-Sun;Yoon, Chan-Hoon;Choi, Heui-Joo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.4
    • /
    • pp.290-298
    • /
    • 2014
  • Ultrasonic thickness measurement is a non-destructive method to measure the local thickness of a solid element, based on the time taken for an ultrasound wave to return to the surface. When an element is very thin, it is difficult to measure thickness with the conventional ultrasonic thickness method. This is because the method measures the time delay by using the peak of a pulse, and the pulses overlap. To solve this problem, we propose a method for measuring thickness by using the power cepstrum and the minimum variance cepstrum. Because the cepstrums processing can divides the ultrasound into an impulse train and transfer function, where the period of the impulse train is the traversal time, the thickness can be measured exactly. To verify the proposed method, we performed experiments with steel and, acrylic plates of variable thickness. The conventional method is not able to estimate the thickness, because of the overlapping pulses. However, the cepstrum ultrasonic signal processing that divides a pulse into an impulse and a transfer function can measure the thickness exactly.