• Title/Summary/Keyword: 초음파비파괴검사

Search Result 549, Processing Time 0.021 seconds

Procedure Development and Qualification of the Phased Array Ultrasonic Testing for the Nuclear Power Plant Piping Weld (원자력발전소 배관 용접부 위상배열 초음파검사 절차서 개발 및 기량검증)

  • Yoon, Byung-Sik;Yang, Seung-Han;Kim, Yong-Sik;Lee, Hee-Jong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.317-323
    • /
    • 2010
  • The manual ultrasonic examination for the nuclear power plant piping welds has been demonstrated by using KPD(Korean Performance Demonstration) generic procedure. For automated ultrasonic examination, there is no generic procedure and it should be qualified by using applicable automated equipment. Until now, most of qualified procedures used pulse-echo technique and there is no qualified procedure using phased array technique. In this study, data acquisition and analysis software were developed and phased-array transducer and wedge were designed to implement phased array technique for nuclear power plant in-service inspection. The developed procedure are qualified for performance demonstration for the flaw detection, length sizing and depth sizing. The qualified procedure will be applied for the field examination in the nuclear power plant piping weld inspection.

A Study on a Crack Evaluation Technique for Turbine Blade Root Using Phased Array Ultrasonics (위상배열 초음파를 이용한 터빈 블레이드 루트부내 결함평가 기법 연구)

  • Cho, Yong-Sang;Jung, Gye-Jo;Park, Sang-Ki;Kim, Jae-Hoon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.2
    • /
    • pp.151-157
    • /
    • 2004
  • Ultrasonic testing is a kind of nondestructive test to detect a crack or discontinuity in materials or on material surfaces by sending ultrasound to it. This conventional ultrasonic technique has some limitations in reliably detecting crack or accurately assessing materials in the case of complex-shaped power plant components such as a turbine blade root. An alternative method for such a difficult inspection is highly needed. In this study, application of a phased array ultrasonic testing (UT) system to a turbine blade, one of the critical power plant components, has been considered, and the particular incident angle has been determined so that the greatest track detectability and the most accurate crack length evaluation nay be achieved. The response of ultrasonic phased array was also analyzed to establish a special method to determine the track )ength without moving the transducer. The result showed that the developed method for crack length assessment is a more accurate and effective method, compared with the conventional method.

Classification Technique for Ultrasonic Weld Inspection Signals using a Neural Network based on 2-dimensional fourier Transform and Principle Component Analysis (2차원 푸리에변환과 주성분분석을 기반한 초음파 용접검사의 신호분류기법)

  • Kim, Jae-Joon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.6
    • /
    • pp.590-596
    • /
    • 2004
  • Neural network-based signal classification systems are increasingly used in the analysis of large volumes of data obtained in NDE applications. Ultrasonic inspection methods on the other hand are commonly used in the nondestructive evaluation of welds to detect flaws. An important characteristic of ultrasonic inspection is the ability to identify the type of discontinuity that gives rise to a peculiar signal. Standard techniques rely on differences in individual A-scans to classify the signals. This paper proposes an ultrasonic signal classification technique based on the information tying in the neighboring signals. The approach is based on a 2-dimensional Fourier transform and the principal component analysis to generate a reduced dimensional feature vector for classification. Results of applying the technique to data obtained from the inspection of actual steel welds are presented.

Study on Ultrasonic Transducer for Non-Destructive Evaluation of Highly Attenuative Material Using PMN-PT Single Crystal (PMN-PT 압전 단결정을 이용한 고감쇠 재료 비파괴 평가용 초음파 탐촉자 연구)

  • Kim, Ki-Bok;Ahn, Bong-Young;Kim, Young-Gil;Park, Sang-Ki;Ha, Jeong-Soo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.4
    • /
    • pp.313-320
    • /
    • 2007
  • Recently, a new class of single-crystal piezoelectric materials such as lead metanibobate doped with lead titanate (PMN-PT) has been synthesized and were found to further enhance the electro-mechanical coupling factor compared to piezo-ceramic materials. This paper describes fabrication and evaluation of PMN-PT single crystal ultrasonic transducers for contact measurement of stainless steel that is one of the highly attenuative materials. The design conditions for ultrasonic transducer such as front matching layer between test materials and piezo-material and backing materials were investigated based on the simulation results by KLM model. The PMN-PT single crystal ultrasonic transducers with centre frequencies at 1 and 2.25 MHz were fabricated and their performances were evaluated.

Models of Reliability Assessment of Ultrasonic Nondestructive Inspection (초음파 비파괴검사의 신뢰도 평가 모델)

  • Park, I.K.;Park, U.S.;Kim, H.M.;Park, Y.W.;Kang, S.C.;Choi, Y.H.;Lee, J.H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.6
    • /
    • pp.607-611
    • /
    • 2001
  • Ultrasonic inspection system consist of the operator, equipment and procedure. The reliability of results in ultrasonic inspection is affected by its ability. Furthermore, the reliability of nondestructive testing is influenced by the inspection environment, materials and types of defect. Therefore, it is very difficult to estimate the reliability of NDT due to the various factors. In this study, the probability of detection by logistic probability model and Monte Carlo simulation is used for the reliability assessment of ultrasonic inspection. The utility of the NDT reliability assesment is verified by the analysis of the data from round robin test nth these models.

  • PDF

Inspection of A Deteriorated Bridge Pier Cap Using Common Nondestructive and Destructive Test (파괴 및 비파괴 검사를 이용한 노후 교량의 교각 두부 조사)

  • Kim, Tae Wan;Hong, Sung Nam;Han, Kyoung Bong;Park, Sun Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.2
    • /
    • pp.91-102
    • /
    • 2008
  • Nondestructive testing techniques have been historically and commonly used to evaluate the quality of existing concrete structures. The techniques utilized included visual inspection, hammer sounding, Schmidt hammer rebounding, and ultrasonic pulse velocity testing including tomographic imaging. Results of the nondestructive tests were used to determine areas to be tested with local destructive tests. These tests included concrete compressive strengths, chloride testing, and petrographic testing. The overall results indicate that inside core of each of the pier caps are healthy. On all of the pier caps, extensive exterior concrete layer rehabilitation needs to be completed. This paper shows the application and interpretation of common nondestructive testing techniques and the consequent repair, rehabilitation, maintenance decisions and safety assesment.

A Study on the Guided Wave Mode Conversion using Self-calibrating Technique (자가교정기법에 의한 유도초음파 모드전이에 관한 연구)

  • Park, Jung-Chul;Cho, Youn-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.3
    • /
    • pp.206-212
    • /
    • 2000
  • The guided wave mode conversion phenomena were investigated for the NDE of a plate-like structure with thickness variation. The ratios of reflection and transmission (R/T) were measured via the self-calibrating procedure which allows us to obtain experimental guided wave data in a more reliable way regardless of the coupling uncertainty between transducer & specimen. The results on R/T could be used to determine the thickness reduction of the structure. It was shown that not only the incident modes but also the converted ones need to be considered in the self-calibrating guided wave inspection to extract a reasonable correlation between experimental data & the thickness variation. Through this study, the potential of guided wave inspection as a quantitative NDE technique was explored based on the combined concept of self-calibration & multi-mode conversion in guided wave scattering problems.

  • PDF

The Study of Micro Crack Detection in Dissimilar Metal Weld Using a Variable Ultrasound Infrared Thermography (가변초음파 적외선열화상을 이용한 이종접합용접부의 미세균열 검출 연구)

  • Park, Jeong-Hak;Park, Hee-Sang;Choi, Man-Yong;Kwon, Koo-Ahn
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.3
    • /
    • pp.215-220
    • /
    • 2015
  • As a nondestructive inspection technology currently in use, infrared thermography has gradually expanded its application range to industry. The method detects only defect areas by grafting ultrasound on a technique of detecting infrared energy emitted from all objects with absolute temperature of 0 K and converting this energy into thermography for inspection. Ultrasound infrared thermography has merits including the ability to inspect a wide area in a short time without contacting the target object. This study investigated the applicability of the technique for defect detection using variable ultrasound excitation inspection methods on samples of Terfenol-D, a magnetostrictive material with a tunable natural resonant frequency.