• Title/Summary/Keyword: 초음파기술

Search Result 1,175, Processing Time 0.027 seconds

Basic Study on the Design and Optimization of Sonoreactors for Sonochemical Water/Wastewater Treatment Processes (초음파 수처리 공정 개발을 위한 반응기 설계 기초 연구)

  • Kim, Seulgi;Son, Younggyu
    • Journal of Wetlands Research
    • /
    • v.16 no.2
    • /
    • pp.205-212
    • /
    • 2014
  • Ultrasound technology can be applied in various fields including environmental, energy, and material engineering processes. In this study the effect of liquid height/volume on calorimetric energy and sonochemical oxidation was investigated as one of the basic steps for the design of water/wastereater treatment sonoreactors. The liquid height was increased from 0 to $4{\lambda}$ by $1/4{\lambda}$ and it was found that both calorimetric energy and sonochemical oxidation were significantly increased at relatively high liquid height/volume where the power density was relatively low. The sonochemiluminescence (SCL) images for the visualization of the activity of cavitation also showed that larger and more stable active zone was formed with high SCL intensity at high liquid height/volume. Therefore, it was revealed that sonoreactors for water/wasterwater treatment could be significantly effective in terms of removal efficiency and energy consumption.

Beamforming Technology in Medical Ultrasound System (초음파진단기의 빔포밍 기술)

  • Bae, Moo-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.551-563
    • /
    • 2012
  • Medical ultrasound systems have been used since 1950s, and are now widely used in most hospitals as indispensable diagnostic imaging systems. Since array probe was introduced in 1970s, beamforming technology using electronic signal processing has been adopted to the medical ultrasound system, and has been improved. Beamforming is a important technology which defines the resolution of the ultrasound system. In this paper, the technologies are introduced from basic beamforming principles to current trend. They include principles of beamforming using array probe, basic theory, and practical implementation, and recent topics of synthetic aperture imaging, adaptive beamforming, 2-dimensional beamforming using 2-dimensional array are also introduced. These various technologies will improve system performances continuously by merging innovatively with various technologies in other fields.

A Design of Position Tracking System for Moving Targets with Ultra-Acoustic Sensor (초음파 센서를 이용한 이동표적 위치추적 시스템 설계)

  • Lim, Joong-Soo
    • Proceedings of the KAIS Fall Conference
    • /
    • 2008.11a
    • /
    • pp.188-190
    • /
    • 2008
  • 본 논문에서는 초음파 센서를 이용하여 이동하는 표적의 위치를 실시간으로 추적하는 위치추적 시스템을 개발하였다. 위치 추적 시스템은 4 개의 초음파 센서를 이용해서 각 센서에서 탐지되는 표적까지의 거리 정보를 이용하여 이동하는 표적의 위치좌표(x,y)를 구하였다. 특히 초음파 센서가 가지고 있는 빔폭 특성을 고려하여 4 개 센서 중 2개 센서에만 표적이 탐지될 경우 표적의 위치를 최적화하는 방안을 제시하였으며 개발된 알고리즘을 하드웨어에 장착하어 감시시스템이 실시간 양호하게 구동하는것을 확인하였다.

  • PDF

Ultrasound-guided Intervention in Lumbar Spine (요추부 초음파 유도하 중재술)

  • Moon, Sang Ho
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.6 no.2
    • /
    • pp.81-93
    • /
    • 2013
  • This review was described to investigate the feasibility of using ultrasound as an image tool for interventions of lumbar spine. This article will first provide an overview of lumbosacral spine surface anatomy and sonoanatomy. A detailed understanding of anatomy is critical for interpretation of ultrasound and procedural performance at spine. Fluoroscopy is most commonly used in interventional spine procedures, but radiation exposure is the major concern when obtaining fluoroscopic images. Ultrasound is radiation-free, is easy to use, and can provide real-time images with high accuracy. Also this device can be used in virtually any clinical setting. Ultrasound guidance offers a reliable alternative to fluoroscopy or computed tomography for lumbar interventions and can be safely performed without radiation exposure.

  • PDF

Modal Analysis of an Ultrasonic Tool Horn for RFID TAG Micro-pattern Forming (RFID TAG 미세패턴 성형을 위한 공구혼 진동해석)

  • Kim, Kang-Eun;Lee, Bong-Gu;Choi, Sung-Ju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.652-658
    • /
    • 2016
  • In this paper, the theoretical research and simulation using the Finite Element Method (FEM) to design and form a micro-pattern for an ultrasonic horn is described. The present method is based on an initial design estimate obtained by FEM analysis. The natural and resonant frequencies required for the ultrasonic tool horn used for forming the fine pattern were predicted by finite element analysis. FEM analysis using ANSYS S/W was used to predict the resonant frequency for the optimum technical design of the ultrasonic horn vibration mode shape. When electrical power is supplied to the ultrasonic transducer, it is converted into mechanical movement energy, leading to vibration. The RFID TAG becomes the pattern formed on the insulating sheet by using the longitudinal vibration energy of the ultrasonic tool horn. The FEM analysis result is then incorporated into the optimal design and manufacturing of the ultrasonic tool horn.

Practical Application of Continuous Suspended Sediment Concentration Measurement using H-ADCP (H-ADCP를 활용한 연속적인 부유사농도 측정 방법의 실용화)

  • Geunsoo Son;Youngsin Roh;Dongsu Kim;Suin Choi
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.134-134
    • /
    • 2023
  • 하천의 유사량 측정은 수량·수질 관리에 있어 유량 자료와 함께 필수적인 자료로 다지점에서 연속적으로 측정된 자료가 필요하다. 하지만 현재 부유사 측정 방법은 부유사채집기를 통해 조사가 이루어져 인력, 비용, 안전의 문제로 지점 확대와 연속 측정이 어려운 상황이다. 이러한 문제를 해결하기 위한 대안으로, 센서 기반의 유사량 측정 기술이 개발되어 실용화를 위한 연구들이 수행되고 있다. 특히, 연속적인 유량측정을 목적으로 사용되고 있는 자동유량관측소에 설치된 H-ADCP의 초음파산란도를 이용한 부유사농도 측정 방법은 기 구축된 인프라를 활용하므로 경제적으로 유리하며, 유량자료를 동시에 측정하므로 실시간의 부유사량 자료를 생산할 수 있는 장점이 있다. 이에 본 연구에서는 국가하천에 설치되어 운영 중인 자동유량관측소 H-ADCP의 초음파산란도를 활용하여 연속적인 부유사농도 측정을 위한 기술 개발과 기술 적용을 위한 기준 및 지침을 마련하고자 하였다. 초음파산란도를 활용한 부유사농도 측정 방법의 적용성 검토를 위해 2015년부터 2022년까지 자동 관측소 기준 유사량 측정이 이루어진 지점을 대상으로 자료를 수집하여 지점별 초음파산란도-부유사농도 관계식을 개발하여 분석을 수행하였다. 그리고 테스트베드에서 실시간 운영을 통해 초음파산란도를 활용한 부유사농도 측정 방법의 기술 개선과 분석 절차 및 기준 등 실무적 고려사항을 검토하여 실용화를 위한 지침 및 표준안을 마련하고자 하였다. 본 연구결과를 통해 기존 부유사채집기와 정확도를 분석한 결과, 기존 부유사대비 약 80%의 측정정확도를 보이는 것으로 나타났으며, 10분 간격의 부유사농도의 측정을 통해 홍수기 유사의 이력현상의 분석이 가능함을 확인 할 수 있었다. 추후에는 본 연구 성과를 통해서 개발한 기술을 시범 확대 적용하여 지속적인 기술의 개선과 측정기준을 제시하고, 유지관리 등에 대한 검토를 수행할 예정이며, 실용화를 통해 유사량 조사지점의 확대와 연속적인 유사량 자료를 생산하는데 기여할 것으로 기대된다.

  • PDF

Effect of Thyroid Cancer on Ultrasound Screening (갑상선암 초음파 수검의도에 영향을 미치는 요인)

  • Lee, Seong-Ran
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.05b
    • /
    • pp.802-805
    • /
    • 2011
  • 본 연구는 갑상선암 초음파 수검의도에 영향을 미치는 요인들을 규명하기 위해 시도하였다. 자료는 2010년 12월 13일부터 2011년 1월 31일까지 한 종합병원 건강검진센타에 내원한 검진자 205명을 대상으로 설문 및 면접조사로 도출하였다. 연구결과 첫째, 보건의료에 따른 갑상선암 초음파수검의도는 수검의도가 있는 응답자의 경우 본인의 건강이 양호하다는 85.5%로 건강이 양호하지 못하다의 14.5%보다 유의하게 높았다($X^2$=6.73 p<.01). 둘째 갑상선암 초음파수검의도의 영향요인은 본인이 건강하다는 사람이 그렇지 않은 사람에 비해 2.53배 수검의도가 유의하게 높았다(95% Cl=1.39-12.7) 따라서 홍보를 통한 초음파검진에 대한 국민적 호응을 유도하는 것이 갑상선암의 조기발견을 위한 초음파검진 정책을 효율적으로 운영하는 대안이 될 것이다.

  • PDF

Experimental Studies on Ultrasonic Guided Waves for the On-Line Inspection of Structural Integrity of Nuclear Power Plants (원전 기기 건전성의 온라인 검사를 위한 유도 초음파의 실험적 연구)

  • Eom, Heung-Seop;Kim, Jae-Hee;Song, Sung-Jin;Kim, Young-H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.4
    • /
    • pp.331-340
    • /
    • 2004
  • Deployment of an advanced on-line monitoring of the component integrity offers a prospect of improved performance, enhanced safety, and reduced overall cost for nuclear power plants. Ultrasonic guided waves have been known as one of the promising techniques that could be utilized for on-line monitoring. The present work is aimed at developing a new method for on-line monitoring of the pipes during the operation period of nuclear power plants. For this purpose, the steam generator (S/G) tube was selected as an object of tile experiment. Dispersion corves and the incident angles corresponding to the specific modes were calculated for the S/G tube. The modes of guided waves were identified by the time-frequency diagrams obtained by the short time Fourier transform. It was experimentally confirmed that there was no mode conversion when the ultrasonic guided waves passed over the curved region of the S/G tube. An optimum mode of guided wave for the S/G tube was suggested and verified by the experiment.

초음파 모터의 응용(최근에 출원된 일본 특허를 중심으로)

  • 임기조;강문성
    • 전기의세계
    • /
    • v.43 no.7
    • /
    • pp.32-38
    • /
    • 1994
  • 본고는 모터를 채용해야하는 시스템의 개발 및 성능 개선시 초음파 모터의 적용 타당성을 판단하는 하나의 참고 자료를 관련 연구자, 기술자에게 제공할 목적으로 초음파 모터의 활용에 가장 적극적이며 앞서 있는 일본에서 출원된 최근의 공개 특허 및 실용 신안 특허를 중심으로 초음파 모터의 응용분야를 살펴보고자 한다.

  • PDF