• Title/Summary/Keyword: 초음파기기

Search Result 211, Processing Time 0.032 seconds

Field Application of Ultrasonic Inspection System for Stay Welds at Steam Generator of KSNP (한국표준형 원전 증기발생기 Stay 용접부 자동검사시스템 및 현장 검증)

  • Lim, Sa Hoe;Park, Chi Seung;Park, Chul Hoon;Joo, Keum Chong;Noh, Hee Chung;Yoon, Kwang Sik
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.6 no.1
    • /
    • pp.37-42
    • /
    • 2010
  • The stay cylinder weld at the steam generator of Korean Standard Nuclear Power Plants is safety class I component and is subjected to be inspected by the volumetric examination such as ultrasonic method. As accessibility of this area is limited due to the narrow space and high radiation, the existing manual inspection method involves various difficulties. Moreover operators may be exposed to internal contamination by contaminated dust during the surface buffing process to improve the inspection reliability of this area. Recently the new automatic inspection system for stay cylinder welds has been developed. The inspection system basically consists of a driving assembly, data acquisition device and signal processing units. The driving assembly is classified by 1) the scanner for inspecting and buffing the weld, 2) pillars for guiding the scanner and 3) the base frame for loading and supporting pillars. The scanner has 4 sensor modules to inspect in 4 refracted angles and 4 incident directions. These components can be inserted into the skirt of the stay cylinder through the manway hole and assembled easily by one-touch in the skirt. Data acquisition device and signal processing units developed in previous works are also newly upgraded for better processing of data analysis and evaluation. The system has been successfully demonstrated not only in the mock-up but also in the field. In this paper, newly developed inspection system for the stay cylinder weld of the steam generator is introduced and their field applications are discussed.

  • PDF

Dielectric and Piezoelectric Properties of Low Temperature Sintering PZN-PZT Ceramics with a variation of $Li_2CO_3$ Addition ($Li_2CO_3$ 첨가에 따른 저온소결 PZN-PZT 세라믹스의 유전 및 압전특성)

  • Lee, Yu-Hyong;Lee, Sang-Ho;Yoo, Ju-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.307-307
    • /
    • 2007
  • 압전액츄에이터 및 초음파진동자는 전자제품의 소형화 및 경량화, 의료기기, 모바일기기 및 소형로붓의 발전에 힘입어 그 활용범위가 넓게 확장되고 있다. 1960년 Smolenski등에 의해 $A(B_1,B_2)O_3$형 복합 페로브스카이트 구조를 갖는 강유전성 세라믹스에 대한 연구가 시작된 이래 $Pb(Co,Nb)O_3-Pb(Zr,Ti)O_3$, $Pb(Zn,Nb)O_3-Pb(Zr,Ti)O_3$, $Pb(Mg,Nb)O_3-Pb(Zr,Ti)O_3$ 등 3성분계 세라믹스의 유전, 압전 및 강유전 특성에 대한 많은 연구가 진행되어 왔다. 그러나 압전성이 우수한 세라믹스들은 Pb가 포함되어 있기 때문에 $1000^{\circ}C$ 이상에서 PbO가 급격하게 휘발되는 성질에 따라서 조성의 변동이 생겨 재현성이 어려우며 이를 방지하기 위하여 과잉 PbO를 첨가시키기 때문에 환경오염뿐만 아니라, 경제적인 측면에서도 많은 문제점을 가지고 있다. 소결조제를 이용한 산화물 첨가법은 PbO의 휘발을 억제하는 저온소결 방법중 가장 효과적인 방법으로 알려져 있다. 따라서, 본 연구에서는 적층형 압전액츄에이터로 사용하기위한 저온소결 압전세라믹스를 개발하기 위하여 PZN-PZT세라믹스에 $Li_2CO_3$, $Bi_2O_3$, CuO 를 소결조제로 사용하여 $Li_2CO_3$의 첨가량 변화에 따른 압전 및 유전 특성을 관찰하였다.

  • PDF

Korean Industrial Standards of River Measurements (하천 유량측정분야의 한국산업표준)

  • Jongmin, Kim;Sanghwa Jung;Minjun Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.9-9
    • /
    • 2023
  • 하천의 관리 및 활용을 위해서는 하천의 유량, 수심, 유속과 같은 수리량을 측정하고 모니터링하는 것은 매우 중요하다. 이러한 수리량은 측정하는 방법은 직접 측정하는 방법과 구조물을 이용하여 측정하는 방법이 있으며, 직접 측정하는 방법도 지점 유속을 측정하여 도섭법으로 측정하는 방법, 초음파 방식 도플러 유속계를 이용한 횡단 측정방법 및 특정 수심에서 측정한 유속을 이용하여 지표유속법으로 유량을 산정하는 방법 등이 있다. 또한 '수자원의 조사·계획 및 관리에 관한 법률' 제11조제1항에 따르면 수문조사의 방법·기준 및 수문조사 자료의 처리·활용 방법 등은 표준화해야 한다고 명시되어 있다. 정부에서는 WTO의 TBT협정 등 국제규범에 대응하기 위하여 국제표준인 ISO, IEC 등에 부합하는 국가표준운영체계를 유지하기 위하여 여러 분야의 국제 표준에 대한 대응을 수행하고, 국가표준을 관리하고 있다. 그 중 유량측정과 관련된 국가 및 국제 표준은 2018년부터 환경부 국립환경과학원에서 총괄하고, 한국건설기술연구원과 한국수자원공사에서 표준관리를 위한 표준개발협력기관과 국제표준 대응협력을 위한 ISO 국내 간사기관으로 운영되고 있다. 국가표준의 유량분야(TC 113)는 4개의 세부분과위원회(SC)로 구성되어 있고, 하천에서 수행되는 유량, 수심, 유속 측정 및 측정장비의 검정, 강수량 측정기기 등에 대한 39종이 제정되고 관리하고 있다. 한국건설기술연구원에서는 유량분야의 일반사항, 하천에서의 유량측정방법 및 유량측정기기에 관한 표준을 담당하고 있으며, 유량분야의 국제표준의 개발에 관한 과업을 수행하고 있다. 본 발표에서는 한국건설기술연구원에서 관리하는 유량분야 국가표준 및 국제표준의 종류 및 현업에서 수행중인 하천의 유량 측정과 국가표준의 관계에 대하여 설명하고자 한다.

  • PDF

Change of Cerebral Blood Flow during Tilt Tests in Children with Vasovagal Syncope (혈관미주 신경성 실신 소아에서 기립경사 검사 동안에 뇌혈류 변화)

  • Kim, Su Jung;Yom, Hye Won;Hong, Young Mi;Yoo, Jung Hyen;Lee, Sook Hee;Kim, Chong Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.10
    • /
    • pp.983-988
    • /
    • 2003
  • Purpose : Syncope appears to be common. However, the mechanism of syncope is not clear. Increased vagal activity and withdrawal of sympathetic stimulation cause hypotension, bradycardia and finally loss of consciousness. The purpose of this study was to evaluate changes of cerebral blood flow velocity, blood pressure, and heart rate during tilt test in children with vasovagal syncope. Methods : Sixty four children with a past history of syncope were evaluated. The stand up test was performed for 15 minutes after a rest at supine position for 10 minutes, followed by an $80^{\circ}$ tilt test lasting 45 minutes. If presyncope(lightheadedness, nausea, blurred vision, or sweating) or syncope occurred, the study was discontinued. 12-lead electrocardiography, echocardiography, and electroencephalography were performed. Transcranial Doppler study was performed at the middle cerebral artery with 2 MHz continuous Doppler probe in 10 children with positive tilt test. Systolic, diastolic, mean cerebral blood flow velocity, integral, and pulsatility index were measured with blood pressure, heart rate, and $O_2$ saturation. Results : The positive rate of tilt test was 31.3%(20/64). Systolic, diastolic, and mean cerebral blood flow velocity decreased significantly in absence of hypotension or bradycardia during presyncope. Time velocity integral of cerebral artery also decreased significantly. Conclusion : Decreased cerebral blood flow velocity can predict the presyncope manifestation. Impairment of autoregulation of cerebral blood flow might play an important role in the pathophysiology of vasovagal syncope.

A Study on the Implementation of the Multi-Process Structured ISDN Terminal Adaptor for Sending the Ultra Sound Medical Images (다중처리 구조를 갖는 초음파 의료영상 전송용 ISDN(Integrated Services Digital Network) TA(Terminal Adaptor) 구현에 관한 연구)

  • 남상규;이영후
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.3
    • /
    • pp.317-324
    • /
    • 1994
  • This paper proposed a new method in the implementation of ISDN (integrated services digital network) LAPD (link access procedure on the D-channel) and LAPB (link access procedure on the B-channel) protocols. The proposed method in this paper implement ISDW LAPD protocol through multi-tasking operating system and adopt a kernel part that is changed operating system to target board. The features of implemented system are (1) the para.llel processing of the events generated at each layer, as follows (2) the supporting necessary timers for the implementation of ISDW LAPD protocol from the kernel part by using software, (3) the recommanded SAP (Service Access Point) from CCITT was composed by using port function in the operating system. With the proposed method, the protocols of ISDH layerl, layer2 and layer3 (call control) were implemented by using the kernel part and related tests were carried out by connecting the ISDH terminal simulator to ISDN S-interface system using the ISDN LAPD protocol The results showed that ISDW S-interface terminals could be discriminated by TEI (Terminal Equipment Identifier) assignment in layer 2 (LAPD) and the message transmission of layer 3 was verified by establishing the multi-frame transmission and then through the path established by the LAPD protocol, a user data was tranfered and received on B-channel with LAPB protocol Thererfore, as new efficient ISDN S-interface environment was implemented in the thesis, it was verified that the implemented system can be utilized by connecting ISDW in the future to transfer a medical image data.

  • PDF

A neck healthy warning algorithm for identifying text neck posture prevention (거북목 자세를 예방하기 위한 목 건강 경고 알고리즘)

  • Jae-Eun Lee;Jong-Nam Kim;Hong-Seok Choi;Young-Bong Kim
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.23 no.3
    • /
    • pp.115-122
    • /
    • 2022
  • With the outbreak of COVID-19 a few years ago, video conferencing and electronic document work have increased, and for this reason, the proportion of computer work among modern people's daily routines is increasing. However, as more and more people work on computers in the wrong posture for a long time, the number of patients with poor eyesight and text neck is increasing. Until recently, many studies have been published to correct posture, but most of them have limitations that users may experience discomfort because they have to correct posture by wearing equipment. A posture correction sensor algorithm is proposed to prevent access to the minimum distance between a computer monitor and a person using an ultrasonic sensor device. At this time, an algorithm for minimizing false alarms among warning alarms that sound at the minimum distance is also proposed. Because the ultrasonic sensor device is used, posture correction can be performed without attaching a device to the body, and the user can relieve discomfort. In addition, experimental results showed that accuracy can be improved by reducing false alarms by removing more than half of the noise generated during distance measurement.

Using Ultrasonography in Korean Medicine to Observe Organs and Diseases, and Evidence of its Use (한의학에서 초음파 진단기기를 활용한 장부 및 질병 관찰과 그 활용 근거)

  • Baik, Tai-Hyeun
    • The Journal of Korean Medicine
    • /
    • v.35 no.3
    • /
    • pp.70-92
    • /
    • 2014
  • Objectives: Due to advance of science and IT technology, high tech imaging equipment like ultrasonography, CT, MRI and PET scan is constantly being developed and progressed; use of these techniques is needed for Korean medicine. Methods: Historical study was undertaken on the evidence of using ultrasonography. Normal organs and various sorts of diseases were also observed by ultrasonography. Results: Korean medicine judges disease of internal organs and condition of health by symptoms of functional disease and organic disease based on anatomical theory. Ultrasonography based on anatomical theory is non-invasive and free from radiation exposure and can be performed directly from clinical practice in real-time. Ultrasonography can be a big help for securing the stability of the internal organs in inserting needles in the thorax and abdomen as well as diagnosing functional and organic diseases based on anatomical theory. Conclusion: We look forward to a great development of scientification and objectification of Korean medicine by using and researching imaging equipment based on anatomical theory as well as ultrasonography.

Automatic optimization for time gain compensation and dynamic range control in ultrasound diagnostic systems (초음파 진단 기기에서의 시간 이득 보상과 다이나믹 범위 조절을 위한 자동 최적화 알고리즘)

  • Lee, Duhg-Oon;Kim, Yong-Sun;Ra, Jong-Beom
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.399-402
    • /
    • 2005
  • For efficient and accurate diagnosis of ultrasound images, the time gain compensation (TGC) and dynamic range (DR) control of the ultrasound echo signal are important. TGC is for compensating the attenuation of the ultrasound echo signal along the depth, and DR is used to control the image contrast. In this paper, we propose an algorithm for finding the optimized values of TGC and DR automatically. For TGC, the degree of compensation is determined along the depth based on the effective attenuation estimation of ultrasound signal. For DR optimization, we introduce a novel cost function on the basis of the characteristics of ultrasound image, which provides the minimum value at the optimal DR. Experiments have been performed by applying the proposed algorithm to a real US imaging system. The results show that the algorithm automatically can determine the values of TGC and DR in realtime so that the subjective quality of the corresponding US image may be good enough for diagnosis.

  • PDF

The Vibration Characteristic Analysis by Mode Variation of Ring Type Ultrasonic Motor (링형 초음파모터의 모드선정에 따른 진동특성 해석)

  • 윤신용;백수현;김현일
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.5
    • /
    • pp.309-317
    • /
    • 2004
  • This paper suggested the vibration characteristic improvement by variation mode of ring type ultrasonic motor. Design for the piezoelectric ceramic and elastic body of stator were calculated by the finite element method(FEM) that consider the resonance frequency, vibration mode and coupling efficiency etc. Through the result of vibration analysis from 6 order mode to 8 mode, the 7 order mode was gained very an excellent results that it was the coupling efficient, minimum power loss and bending vibration value. Here over 7 order mode, this paper was acquired that an output current for input voltage was very a large increased results. The result of vibration calculation, from thickness 0.5[mm] to 2[mm], knew the fact that the vibration displacement at 0.5[mm] is an high value too. From such result, this paper was manufactured the ultrasonic motor of outer diameter 5O[mm] , inter 22[mm] having the about 43.86[KHz] resonance frequency. We have gated that a simulation result is 42.2[KHz] and an experiment result is 43.86[KHzl The propriety of this paper was established though comparison. investigation of simulation and experiment result.

Defect Evaluation of Optical Lens by Resonant Ultrasound Spectroscopy (공명초음파분광법을 활용한 광학기기용 렌즈의 결함평가)

  • 김성훈;백경윤;김영남;양인영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1491-1495
    • /
    • 2004
  • In this paper, resonant ultrasound spectroscopy(RUS) was used to determine the natural frequency of a spherical and a aspherical lens. The objective of the paper is to evaluate defect and shape error by using nondestructive evaluation method with Resonant Ultrasound Spectroscopy(RUS). The principle of RUS is that the mechanical resonant frequency of the materials depends on density, and the coefficient of elasticity. We evaluated existence of flaws through comparison with resonant frequency of a spherical and a aspherical lens. The spherical glass lenses were made of BK-7 glass, one's diameter in 2mm and 5mm. The polished spherical glass lenses had no deflection or a deflection below 2.0${\mu}{\textrm}{m}$. Also, The aspherical lens were made of same material and ones diameter in 7mm and thickness in 3.4mm. In the experiment, we were performed to investigate relationship between frequency measuring parameter($\beta$) and mass of each specimens. The difference between resonant frequency and mode of aspherical glass lens which has no defect was distinguished from aspherical glass lens which has some defects.

  • PDF