• Title/Summary/Keyword: 초기 온도

Search Result 3,259, Processing Time 0.034 seconds

Temperature Compensation of Hot-film Flow Sensor (박막 히터형 유량센서의 온도보상)

  • Kim, Hyung-Pyo
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.268-273
    • /
    • 2000
  • This paper represents a hot-film flow sensor which is compensated by a noble temperature compensation method using the initial unbalanced voltage. The resistance value of the sensor is determined by using the graph of the initial unbalanced voltage of an open-loop circuit against the air temperature. The compensation is accomplished by applying the unbalanced ratio of the resistors in the Wheastone bridge circuit. In the range of air temperature of $-20^{\circ}C{\sim}120^{\circ}C$, the error is about ${\pm}1%$.

  • PDF

A Study on the Actual Conditions of and Satisfaction with the Existed Female Dress Forms Usage (국내 여성용 인대 사용 실태 및 만족도에 관한 연구)

  • Park Gin-Ah;Lee Hye-Young;Choi Jin-Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.30 no.3 s.151
    • /
    • pp.378-385
    • /
    • 2006
  • To release fashion trends in an efficient way, many of the apparel business and fashion educational institutes in land adopt fashion shows employing fashion models. Modeling rather than flat pattern making realizes the majority of the complicated design works for the fashion shows. However, for the different measurements between the dress form and the real human model, problems often occur during the modeling and fitting processes. Researches on the standard dress form development representing professional fashion models' features are therefore in urgent need to enable the related apparel business and fashion institutes to make appropriate use of the dress form in their jobs. The study has been conducted as a preliminary study using a questionnaire method ultimately to develop the female dress form. A questionnaire in the research aimed at an investigation into the actual conditions of and satisfaction with the usage and the body measurements of existed dress forms. Approximately 30 fashion-related educational institutes and 10 apparel companies responded to the survey. Data derived from the survey was analyzed using SPSS version 10.1, the statistics tool. The results throughout the research were discussed in terms of largely three categories that are; (1) the general conditions of the usage of the dress form to prepare fashion shows: e.g. the frequency of holding the fashion show in an annual term, the proportion of professional and amateur models employed for the fashion show, the methods to construct garments, types and number of dress forms utilized and etc.; (2) factors considered to purchase the dress form e.g. its functionality, shapes, sizes, duration, price, A/S condition and etc.; and(3) satisfaction with the similarity between the dress form and the human body in the relation to the body measurements. Measurements in length wise, front and back waist lengths, neck to bust point on the dress forms were apparently differed from the ones of the actual body. In particular, differed torso length measurements cause the problem to have to alter the whole silhouette, consequently, the resultant patterns as well. In girth measurements, in order of bust and waist girths, the satisfaction was low.

Deformation and Stress Distribution of Discontinuous Precast Concrete Track Slab : II. Stress Distribution (불연속 프리캐스트 콘크리트궤도 슬래브의 변형과 응력 분포 : II. 응력 분포)

  • Lee, Dong Hoon;Kim, Ki Hyun;Jang, Seung Yup;Zi, Goangseup
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.5
    • /
    • pp.637-648
    • /
    • 2017
  • In this paper, the effects of initial built-in deformation and temperature deformation on the stress distribution of discontinuous precast concrete track slab under train load were examined. According to the results, when train load is put on a precast concrete slab with initial built-in deformation and deformation due to temperature gradient, the maximum tensile stresses develop at the upper side of slab in the slab center, edge center and corner of shear pocket; the stress distribution is different from that of the case under train load only. Therefore, to accurately predict the actual weak points and failure modes, one should calculate the stress under train load considering the initial built-in and temperature deformation of the slab.

A Study on Crack Control of Early-aged Reinforced Concrete Rahmen Bridge (초기재령 철근큰크리트 라멘교의 균열제어에 관한 연구)

  • Jung Hee-Hyo;Lee Sung-Yeol;Kim Woo-Jung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.19 no.1 s.71
    • /
    • pp.15-25
    • /
    • 2006
  • The researches on the early-aged concrete hydration process and the techniques for the early-aged concrete crack control mainly have been focused and developed on the massive concretes in both experimental and numerical studies. However, those researches for relatively thin members such as the upper slab of the reinforced concrete rahmen bridge have nearly been attempted. In this study, a designing technique for crack controlling in the thin members of the early-aged reinforced concrete rahmen bridges based on measured temperature history, strength revelation model and sinkage model is proposed. A method of calculating the reinforcing bar area for crack controlling is also proposed and it is found that the distributing bars under the design loads become the main reinforcing bars in the temperature stress analysis of the early-aged reinforced concrete rahmen bridges. It is shown that the proposed analysis technique is able to use the design of crack control for the early-aged reinforced concrete rahmen bridge.

Deformation and Stress Distribution of Discontinuous Precast Concrete Track Slab : I. Initial and Temperature Deformation (불연속 프리캐스트 콘크리트궤도 슬래브의 변형과 응력 분포 : I. 초기 및 온도 변형)

  • Lee, Dong Hoon;Kim, Ki Hyun;Jang, Seung Yup;Zi, Goangseup
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.5
    • /
    • pp.625-636
    • /
    • 2017
  • This study looked into the behavior of precast concrete track due to temperature variation and initial track deformation and examined the effect of initial deformation and deformation caused by temperature gradient on the stress distribution of slab under train load. In this paper, one of two papers in a series, a finite element analysis model for calculating deformation and stress of precast concrete track was proposed; the temperature distribution and displacements measured at the precast concrete track in the field were compared with the analytical results. The results show that the slab always curled up due to initial deformation; by comparing the measured displacements with the displacements calculated by taking measured temperatures at each depth as input, the effective built-in temperature (EBITD), the temperature difference between the top and bottom of the slab corresponding to the initial deformation, can be estimated. If EBITD is relevantly assumed, the calculated displacements correlate well with the measured ones.

Experimental Investigation on Variation of Internal Relative Humidity and Temperature due to Hydration of Concrete at Early Age (내부 온습도 측정을 통한 초기재령의 콘크리트 내부 습도 및 수화열 변화 특성 분석)

  • Hong, Sung-Ki;Park, Cheol-Woo;Park, Sung-Jae;Kang, Tae-Sung;Kim, Hee-Sung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.741-744
    • /
    • 2008
  • Quality control of early age concrete significantly influences the long term performance. Primary factors for early age concrete quality control should include the relative humidity and temperature variation, and these are more important as structures become massive and huge. Temperature raise due to cement hydration causes stress, which can develop to cracking with internal and/or external restraints. Exposure conditions including ambient temperature, humidity and wind also significantly affect the cracking behavior of early age concrete. Among many of studies on the early age concrete behavior, investigation on the variation of temperature and relative humidity internal of concrete is not common. That is in part because the difficulties in measuring the relative humidity and temperature inside the concrete. This study used a digital sensor with an appropriate logger to measure internal temperature and relative humidity. This direct measuring method is expected to provide more reliable and comprehensive data acquisition on the early age behavior of concrete.

  • PDF

Development of Shelf-life Prediction Model of Tofu Using Mathematical Quantitative Assessment Model (수학적 정량평가 모델을 이용한 두부의 유통기한 예측 모델의 개발)

  • Shin Il-Shik
    • Food Industry And Nutrition
    • /
    • v.10 no.1
    • /
    • pp.11-16
    • /
    • 2005
  • 식물성 단백질의 주요 공급원이며 우리나라 전통식품 중의 하나인 두부의 유통기한을 정량적으로 예측할 수 있는 수학적 모델을 개발하고자 온도와 초기균수에 따른 두부 부패세균의 성장 실험 결과를 데이터베이스화하여 이를 바탕으로 균의 성장을 정량적으로 평가할 수 있는 수학적 모델을 개발하였다. 근의 증식 지표인 최대증식속도상수(k), 유도기(LT), 세대시간(GT)은 온도에 지배적인 영향을 받았으며, 초기균수에 따른 유의 적 인 차이 는 없었다(p<0.05). 최대증식속도상수와 온도 및 초기균수의 상관관계를 나타내는 수학적 정량평가모델인 square root model을 이 용하여 두부 부패 세균의 성장을 정량적으로 예측할 수 있는 모델$({\surd}{\kappa}=0.016861(T+6.87095))$을 개발하였으며 실험치와 예측치의 상관계수는0.969이었다. 이 예측 정량평가모델로부터 예측한 최대증식속도상수와 두부의 관능적 부패시 점을 반영 한 Gompertz 변형 모델을 이용하여 두부의 유통기한을 예측할 수 있는 모델$(Spoilage-critrion(hr)=\frac{2{\times}Ln2+Ln[(Nmax/No)-1])}{k}$을 개발하였다

  • PDF

Heat Transfer Characteristics for Inward Solidification in a Horizontal Cylinder Packed with P.C.M. (상변화물질을 충전한 수평원통관 내에서 응고시 열전달특성)

  • Yum, Sung-Bae;Hong, Chang-Shik;Lee, Chai-Sung
    • Solar Energy
    • /
    • v.11 no.2
    • /
    • pp.51-62
    • /
    • 1991
  • Heat transfer characteristics for heat retrieving processes in a paraffin-filled horizontal circular cylinder was studied. Theoretical and experimental analyses were carried out. In the theoretical analysis, solid and liquid phases were treated separately. Namely, convection for liquid and conduction for solid phase were investigated respectively. The retrieved heat was calculated from the experimentally determined solidified mass. Furthermore, the effects of initial temperature of the liquid and cooling temperature on the heat discharge rate were also studied. In the heat retrieving process, the governing factor for the solidifying rate is the cooling temperature, because most of the liquid sensible heat is rapidly discharged in the initial stage of solidification. Hence heat transfer mechanism during heat retrieving process can be safely considered as conduction. In the cut of frozen paraffin, there showed an empty space in the upper region. It is caused by the temperature drop in the liquid paraffin. While volume shrinkage caused by phase transition was indiscernible. Irrespective of cooling temperature and initial liquid temperature, solidified mass was well-correlated with the product of Fourier number and Stefan number in the solid phase.

  • PDF

Study on Methodology of Trade-Off for Space-borne FPA Thermal Design by Simplified Thermal Node Analysis (단순화 된 열 저항 해석을 이용한 우주용 FPA 열제어 설계 방안 연구)

  • Chang, Jin-Soo;Yang, Seung-Uk;Kim, Jong-Un;Kim, Ee-Eul
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.2
    • /
    • pp.179-185
    • /
    • 2015
  • The main objective of thermal design for a space-borne FPA(Focal Plane Assembly) is to provide stable thermal environment during imaging operation and thus maintain the image quality. An FPA must be maintained within its operating temperature range and cooled down to its initial temperature soon enough for the next imaging operation. This paper describes the study result on performing trade-off studies for FPA thermal design by using simplified thermal node analysis about FPA preliminary design. It also describes the verification results of the study by comparing thermal analysis results and trade-off study results. According to results, we can conclude that this approach is useful for simple and quick trade-off studies without thermal analysis based on thermal math models.

Sensorless initial position detecting method and speed control using parameter compensator with flux observer of the 2-phase SRM with asymmetric inductance profile (비대칭 2상 SRM의 초기각 검출과 파라미터 오차 보상기를 가지는 자속관측기법을 적용한 센서리스 속도제어)

  • Lim, Geun Min;Lee, Jong-Heon;Ahn, Jin-Woo;Lee, Dong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.153-154
    • /
    • 2011
  • 본 논문은 비대칭 2상 SRM의 센서리스 속도제어를 위한 초기각 검출 및 초기 기동방식과 자속관측기를 적용한 센서리스 제어에서 전동기의 온도 및 파라미터 변동에 의한 자속 오차 성분으로 인해 발생하는 위치 추정오차를 보상하기 위한 새로운 보상기를 제안한다. 제안된 방식은 전압펄스 인가로 초기각을 검출하고 검출된 초기 위치정보를 바탕으로 동일한 전압펄스 인가를 통해 비여자상이 여자상이 되는 회전자 위치를 검출하여 상여자를 교체하는 초기기동을 통해 자속관측기를 적용한 센서리스 제어로 안정적으로 진입하도록 한다. 이 때, 제안된 추정위치 보상기를 통해 추정된 센서리스 위치를 순시적으로 보상한다.

  • PDF