• Title/Summary/Keyword: 초기희석

Search Result 226, Processing Time 0.034 seconds

A Study on the Removal Efficiency of Harmful Pollutants in the Cooking Chamber (조리실내의 유해오염물질 제거율에 관한 연구)

  • Kwon, Woo-Taeg;Lee, Woo-Sik
    • Culinary science and hospitality research
    • /
    • v.22 no.8
    • /
    • pp.149-156
    • /
    • 2016
  • The purpose of this study is to reduce the contaminants (total volatile organic compounds (TVOCs), fine particle, odor and total airborne bacteria) during cooking process in cooking chamber, and to decrease the health damage in indoor space that has bad work environment. In order to solve the shortcomings of existing air purifiers and remove all kinds of pollutants effectively, this study focused on the development of indoor air purifiers which are made of bar type. Bio-ceramics filter which combines activated carbon and loess. The air cleaners developed with 4 measuring items including TVOCs, particulate matter, complex odor and total airborne bacteria were measured comparing their pre-service test to their post-service test after a period of time. The measured results showed higher removal efficiency of 91.02% as the concentration of TVOCs was reduced from $2,500{\mu}g/m^3$ to $223{\mu}g/m^3$. Second, the particulate matter removal ratio was 97.51% efficient with average concentration of $26.68{\mu}g/m^3$. Third, the odor showed 95.20% reduction as air dilution ratio averaged out at 144. Last, total airborne bacteria was eliminated by over 94% showing the changeable concentration from $787{\sim}814CFU/m^3$ to $47{\sim}40CFU/m^3$. In addition, the removal rate of harmful pollutants is excellent, and it is expected that the environment of the existing poor cooking room will be greatly improved by using the developed air purifier in combination with the ventilation device and the stove hood.

Detection of Rice Black-Streaked Dwarf Virus In Rice, Maize and Insect Vectors by Enzyme­linked Immunosorbent Assay (효소결합항체법에 의한 벼, 옥수수 및 매개충에서 벼 검은줄 오갈병의 검정)

  • Woo Yong Bum;Lee Key Woon
    • Korean Journal Plant Pathology
    • /
    • v.3 no.2
    • /
    • pp.108-113
    • /
    • 1987
  • Rice black-streaked dwarf virus(RBSDV) was purified from infected maize leaves. Antiserum against RBSDV was prepared for virus detection by enzyme-linked immunosorbent assay(ELISA). In detection of RBSDV by ELISA, effective dilution range of antiserum extracted in RBSDV-containing host plants and insect vectors was from 320 to 2,560 times in rice plant, 320 to 5,120 in maize plant, and 160 to 2,560 times in insect vector, Laodelphax striatellus F, respectively. The percentage of viruliferous vector in overwintered nymphs of Laodelphax striatellus determined by ELISA were 3.0 in Milyang, 2.3 in Chilgok, and 3.7 in Sunsan area. Dead insect vector which could not be tested for vims infection by conventional rice seedling inoculation test could be tested by ELISA. One hundred plants of rice and maize were randomly sampled in the field and tested whether or not they were infected with RBSDV. In rice plants, 4 out of 98 plants turned out to be infected with RBSDV by ELISA. In maize plant, 3 out of 92 plants which were excepted 8 plants to be appeared symptom already were infected. As a result, ELISA could be detected even in case of symptomless plants at early stage of viral infection.

  • PDF

Characteristics for Co-digestion of Food Waste and Night Soil using BMP Test (BMP실험을 이용한 음식물폐기물 및 분뇨의 병합소화 특성)

  • Cho, Jinkyu;Kim, Hyungjin;Oh, Daemin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.9
    • /
    • pp.13-18
    • /
    • 2014
  • BMP test was carried out to evaluate the characteristics for co-digestion of night soil and food waste. 6 types of sludge were tested in 30 days which were raw, excess, digested, night soil/septic tank (1:1), food waste (food : dilution water = 1:1), and mixed sludge. Bio gas was produced actively after 2 days, and continued in 2 weeks. Gas generation amount was decreased rapidly after considerable space of time. Especially maximum productivity of gas was shown in 7~8 days. The ultimate methane yields of raw, excess, digested, night soil/septic tank, food waste, and mixed sludge were 64.63, 67.49, 66.45, 72.44, 107.85, and 46.71 mL $CH_4/g$ VS respectively from Modified Gompertz model. The lag growth phase time and maximum specific methane production rate of mixed sludge were 1.88 day and 80.4 mL/day respectively. The methane potential of mixed sludge was higher than individual sludge. So high methane potential was expected by controlling mixing ratio of food waste. Besides stable operation of digestion tank and the solution of oligotrophic problem were possible.

A Study on the Performance Recovery of $H_2S$ Poisoned PEMFC ($H_2S$ 피독 고분자 전해질막 연료전지의 연료극 성능 회복 연구)

  • Lee, Soo;Jin, Seok-Hwan
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.1
    • /
    • pp.102-107
    • /
    • 2012
  • The recovery of a Pt anode in a PEMFC through 30 ppm $H_2S/H_2$ exposure was evaluated by using a cyclic voltametry(CV) scan. First, the PEMFC unit cell performanc loss was measured three times under an anode feeding with 30 ppm $H_2S/H_2$ for 1hr at $0.5A/cm^2$ of current density. The initial cell performance was $1.16A/cm^2$ at 0.6 V without $H_2S$ poisoning. After first poisoning step for 1hr the cell performance was decrease to $0.77A/cm^2$, and the further poisoning steps decreased up 0.57 V. Finally, the recovery of the cell performance of $H_2S$ poisoned PEMFC was achieved up to 90.3% by applying CV scan. Moreover, we also found out that another possible approach for over 80% recovery of the cell performance of $H_2S$ poisoned anode Pt catalyst layer was to just inject fresh hydrogen into the anode feeding stream.

Flame Instability in Heptane Pool Fires Near Extinction (소화근처 헵탄 풀화재의 화염불안정성)

  • Jeong, Tae Hee;Lee, Eui Ju
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.12
    • /
    • pp.1193-1199
    • /
    • 2012
  • A cup burner experiment was performed to investigate the effect of the oxidizer velocity and concentration on flame instability near extinction. Heptane was used as a fuel and air diluted by nitrogen and carbon dioxide was used in the oxidizer stream. Two types of flame instabilities at the flame base and at axial downstream were observed near extinction. The instability at the flame base could be characterized by cell, swing, and rotation modes, and the cell mode changed to the rotation mode through the swing mode as the oxidizer velocity increased. To assess the parameters for the flame instability, the initial mixture strengths, Lewis number, and adiabatic flame temperature were investigated under each condition. The Lewis number might be the most important among them, but it is impossible to generalize because of the insufficient number of cases. Furthermore, the axial periodic flickering motion disappeared at low and high oxidizer velocities near extinction. This resulted from the fact that low oxidizer velocity induced evaporated fuel velocity below the critical velocity and high velocity made the reacting fuel velocity comparable.

Current Generation from Microbial Fuel Cell Using Stainless Steel Wire as Anode Electrode (스텐철사를 전극으로 이용하는 미생물연료전지의 전류 발생)

  • Jang, Jae Kyung;Kim, Kyung Min;Byun, SungAh;Ryou, Young Sun;Chang, In Seop;Kang, Young Koo;Kim, Young Hwa
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.11
    • /
    • pp.753-757
    • /
    • 2014
  • Anode electrode in a microbial fuel cell (MFC) should transfer the receiving electron as well as provide large surface area that can be immobilized microorganisms. Microorganisms' population is one of important factors to improve the current generation and to treat the livestock wastewater by biological treatment. These studies were attempted to investigate if stainless-steel wire skein (SSWS) could be used as anode electrode replacement a graphite felt electrode in microbial fuel cell. For these studies, pretreated livestock wastewater was used diluted to 500 mg/L as COD before use. At this time, the current showed a little difference of about 5% when using each of a SSW and graphite felt (control). There was no significant difference in the current value. The organic removal rate in the microbial fuel cells used graphite felt and SSWS was 82.4% and 88.3%, respectively. The COD removal in the MFC used the SSWS was higher than that of graphite felt. Ammonium nitrogen was showed similar trend in two case all. These results about current generation and organic matter reduction seem possible that SSWS was used to anode electrode. When SSWS is used, the initial investment for system construction is expected to be able to reduce by approximately 1/50.

Preparation of Polyolefin Hollow Fiber Membranes and Their Applications (폴리올레핀계 고분자 중공사막의 제조 및 응용)

  • 김진호;박민수;장문석;김성수
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2003.11a
    • /
    • pp.154-154
    • /
    • 2003
  • 세계의 특허동향을 분석해 보면 수처리용 MF/UF 분리막의 제조 및 응용에 관한 연구개발이 매우 활발하게 진행되어져 왔음을 알 수 있다. 또한 다국적 기업들의 적극적인 마케팅과 분리막 공법의 우수한 처리효율이 인정되면서 90년대 후반부터는 수십만톤/일 규모의 징수처리 및 하수고도처리 분야에까지 MF/UF 분리막이 괄목할만한 수요의 증대를 보이고 있으며 이러한 추세는 앞으로도 더욱 확대될 것으로 전망이 되고 있다. 고분자재료를 이용하여 MF/UF 분리막을 제조하는 방법으로는 보편적으로 첫째, 고분자를 용매에 녹인 후 용매와 비 용매간의 상호교환을 유도하여 분리막을 제조하는 상전이법(Phase Inversion). 둘째, 고분자를 고온에서 희석제와 melt-blending 한 후 가해진 열을 제거하면서 상분리를 일으켜 다공성을 부여하는 열유도 상분리법(TIPS, Thermally Induced Phase Separation). 셋째, 결정성 고분자를 용융, 압출 및 냉각하여 결정화도가 매우 높은 전구체를 제조한 후 연신에 의해 비결정 영역을 개열시켜 기공을 형성하는 연신법(Stretching process)이 있다. 이 중 물성이 매우 우수한 폴리올레핀계 결정성 고분자를 이용하여 분리막을 제조할 수 있는 방법은 열유도 상분리법 및 연신법에 제한된다. 본 연구 발표에서는 세계적으로도 극소수의 기업들만이 보유하고 있으며 고도로 축적된 노하우를 필요로 하는 열유도 상분리법 및 연신법에 의하여 폴리프로필렌 및 폴리에틸렌 중공사막을 제조하는 방법과 이 두 가지 방법에 의해서 제조된 중공사막의 구조, 물성 및 수투과 성능 그리고 KMS 중공 사막의 응용사례를 통한 실제 운전특성 등을 소개하고자 한다.좋은 결과를 가져다 주는 술식으로 판단되었다.결과를 이용하여 향후 전개될 홈 네트워크 서비스 및 관련시장의 발전 방향을 전망해 보고 이에 따른 기업이나 정부차원의 대응전략을 파악하고자 한다.육구에서는 큰 변화를 나타내고 있지 않았다(p<0.05). 운동과 비운동시킨 참돔의 지질 함량의 변화는 운동시킨 참돔은 운동으로 인한 에너지 소비로 인하여 함량이 유의적으로 감소했으며(r=-0.35), 비운동사육구에서는 절식으로 인하여 지질함량이 감소하였다(r=-0.38). 파괴강도와 가장 밀접한 영향을 가지는 콜라겐은 운동과 비운동 모두 사육기간동안 큰 변화는 보이지 않았다. 초기의 파괴강도값은 1.45±0.02kg(운동사육구), 1.36±0.18kg(비운동사육구)이였으며 사육기간동안 운동사육구는 파괴강도값이 증가한 반면, 비운동수조에서는 참돔의 파괴강도는 사육기간동안 큰 유의차가 없었다. 각 성분간의 상관도를 살펴보면, 수분함량과 파괴강도는 상관성을 가졌으며, 지질함량과 파괴강도도 같은 경향은 나타내었다. 운동기간동안의 파괴강도와 콜라겐 사이에는 상관성의 거의 없었다. 이는 운동기간에 따른 파괴강도의 증가가 콜라겐의 함량의 증가보다는 지질함량의 감소와 수분함량의 증가와 같은 성분과의 상관성이 크다고 판단된다. 다음으로는, 운동횟수에 의한 영향으로써 운동시간을 1일 6시간으로 설정하여, 운동횟수를 결정하기 위하여 오전, 오후에 각 3시간씩 운동시키는 방법과 오전부터 6시간동안 운동시키는 두 방법을 이용하여 품질을 비교하였다. 각 조건에 따라 운동시킨 참돔의 수분함량을 나타낸 것으로, 2회(오전 3시간, 오후 3시간)에 나누어서 운동시키기 위한 육의 수분함량은 73.37±2.02%를 나타냈으며, 1회(6시간 운동)

  • PDF

Nitrogen Management for Infant Rice Seedlings with Extended Nursery Duration by Delayed Transplanting (벼 육묘일수가 지연된 어린모 이앙재배시 질소분시 방법이 생육 및 수량에 미치는 영향)

  • Han, Hee-Suk;Yang, Woon-Ho;Park, Jeong-Hwa;Yoon, Young-Hwan;Kim, Je-Kyu;Yang, Won-Ha;Park, Jong-Wook
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.53 no.3
    • /
    • pp.239-243
    • /
    • 2008
  • This experiment was carried out to elucidate the appropriate split application method of nitrogen fertilizer in infant rice seedlings which show poor seedling growth resulted from extended seedling nursery duration more than 12 days. The 16 day-old infant rice seedling (DOIRS) showed poor seedling growth than 8 day-old seedling. Early growth of transplanted 16 DOIRS was poor, compared with that of transplanted 8 DOIRS. However, the poor plant growth estimated by plant height, tiller number, and the number of newly developed roots was compensated by 70-0-30% (basaltillering-panicle initiation) of nitrogen split application. In 70-0-30% plots among split nitrogen application methods, tiller number, biomass, and leaf area at heading stage of rice showed the highest values. Sixteen DOIRS plots showed lower grain filling and 1000-grain weight, resulted in lower yield of rice than 8 DOIRS plots in the same nitrogen split application. However the lower yield in 16 DOIRS plots was recovered by 70-0-30% of nitrogen split application method to a similar level in 8 DOIRS plots in which nitrogen was split applied by 40-30-30%.

Geochemistry of Cu-Pb-Zn-Ag Deposits from the Euiseong Mineralized Area (의성 광화대 동-연-아연-은 광상의 지화학적 연구)

  • Chi, Se-Jung;Doh, Seong-Jae;Choi, Seon-Gyu;Lee, Jae-Ho
    • Economic and Environmental Geology
    • /
    • v.22 no.3
    • /
    • pp.253-266
    • /
    • 1989
  • The Cu-Pb-Zn-Ag hydrothermal vein type deposits which comprise the Dongil and Dong-cheogogsan mines occur within the Cretaceous sedimentary rocks in the Euiseong Basin of the southern Korean peninsula. The ore mineralization is contained within three stage(I,II and III) quartz and calcite veins. Ore minerals occur as dominant chalcopyrite, galena, sphalerite, tetrahedrite and Pb, Ag, Sb and Bi-bearing sulfosalts. Stage I ore minerals were deposited between $400^{\circ}C$ and $200^{\circ}C$ from the fluid with moderate salinities(7.0 to 4.5 eq. wt. % NaCl). Evidence of boiling suggests pressure of less than 150 bars during stage I mineralization. This pressure corresponds to maximum depths of 650 m and 1700 m, respectively, assuming lithostatic and hydrostatic loads. The data on mineralogy, temperature and salinity, together with information on the solubility of Cu complex, suggest that Cu deposition is a result of boiling coupled with declining temperature from $350^{\circ}$ to $250^{\circ}C$ or declining log $a_{o_2}$(from -29.8 to -35.9 atm.)and increasing in pH. Pb, Ag, Sb and Bi-bearing sulfosalts were deposited by cooling and dilution at temperature of less than $250^{\circ}C$ from the ore fluid with less than -35.9 atm. of log $a_{o_2}$.

  • PDF

Variations in Geochemical characteristics of the Acid Mine Drainages due to Mineral-Water Interactions in Donghae Mine Area in Taebaek, Korea (태백 동해광인일대의 물-광물의 반응에 의한 산성광산배수의 지구화학적 특성 변화)

  • 김정진;김수진
    • Economic and Environmental Geology
    • /
    • v.35 no.1
    • /
    • pp.55-66
    • /
    • 2002
  • There are several abandoned coal mines around Donghae mine area in the Taebaek coal field. Two major creeks, Soro and Sanae, are contaminated with the colored precipitates formed from the coal mine drainages. Bed rocks of the study area consist of limestone, shale, and sandstone. Limestone consisted mainly of calcite and dolomite, and shale of quartz, pyropyllite and chlorite, and sandstone of quatz and illite. Coal coal spoil dumps composed mainly of pyrite and chlorite. The oxidative dissolution of sulfide minerals leads to acid mine drainage and adds the metal ions in the stream water. The ion concentrations of Fe, Ca, Mg, Al, Si, SO$_{4}$in the stream polluted by AMD are generally higher than those in the unpolluted stream water. High concentrations of Ca and Mg, Al and Si can be resulted from dissolution of carbonate minerals such as calcite, dolomite and aluminosilicates such as chlorite, pyrophyllite. Although the Fe, Al, Si, SO$_{4}$ contents are considerbly high in the acid water released from the mine adits, they become decreased downstream due to dilution of unpolluted water and precipitation of oxide/hydroxide and sulfate minerals on the bottom of stream.