Relationship between the Initial Clamping Force and the Proper Position of Supporter in the Wedge Type Rail Clamp (쐐기형 레일클램프에서 초기압착력과 지지대의 적정위치사이의 관계)

  • Han, Dong-Seop;Lee, Seong-Wook;Han, Geun-Jo;Lee, Kwon-Soon
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.1
    • /
    • pp.357-362
    • /
    • 2006
  • The wedge type rail clamp compresses with small clamping force at first, and with large clamping force when the wind speed increases because of the wedge working. At this time in order to display the wedge working, the rail clamp slips along a rail. If the supporter is not installed in the rail clamp when the wind speed increases more and more, the structure will occur overload which leads the structure to fracture. So the supporter has to be installed in the rail clamp. The proper position of this supporter is determined by the initial clamping force and the wege angle. Therefore in this study we adopted 5-kinds of wedge angle as the design parameters, and carried out the finite element analysis, in order to analyze the relationship between the initial clamping force and the proper position of supporter in the wedge type rail clamp.

  • PDF

Relationship between the Initial Clamping Force and the Position of Supporter in the Wedge Type Rail Clamp (쐐기형 레일클램프에서 초기압착력과 지지대의 위치사이의 관계)

  • Lee, Seong-Wook;Han, Geun-Jo;Lee, Kwon-Soon;Han, Dong-Seop
    • Journal of Navigation and Port Research
    • /
    • v.31 no.1 s.117
    • /
    • pp.65-70
    • /
    • 2007
  • The wedge type rail clamp compresses with small clamping force at first, and with large clamping force when the wind speed increases bemuse of the wedge working. At this time in order to display the wedge working, the rail clamp slips along a rail. If the supporter is not installed in the rail clamp when the wind speed increases more and more, the structure will occur overload which leads the structure to fracture. So the supporter has to be installed in the rail clamp. The proper position of this supporter is determined by the initial clamping force and the wege angle. Therefore in this study we adopted 5-kinds of wedge angle as the design parameters, and carried out the finite element analysis, in order to analyze the relationship between the initial clamping force and the position of supporter in the wedge type rail clamp.

A Experimental Analysis on the Relationship between the Angle of a Locker and the Clamping Force of Wedge Type Rail Clamp (Locker의 물림각과 쐐기형 레일클램프의 압착력에 관한 실험적 고찰)

  • Han Dong-Seop;Shim Jae- Joon;Han Geun- Jo;Lee Kwon-Hee
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2005.10a
    • /
    • pp.247-252
    • /
    • 2005
  • The wedge type rail clamp has the operating mechanism: First, the jaw pad clamps a rail with small clamping force Next as the wind speed increases, the clamping force of the jaw pad is increased by the wedge. In order to design the wedge type rail clamp, we need to determine the proper wedge angle to minimize the sliding distance of a roller and the proper clamping angle of a locker to generate the initial clamping force of a jaw pad. The researches for the proper wedge angle have conducted, and in this study we conducted the investigation to determine the proper clamping angle of a locker in the rail clamp with wedge angle of $10^{\circ}$. Because the initial damping force of the jaw pad was determined by the clamping angle of the locker, in order to carry out the clamping force of a jaw pad, we measured the locking force applied to a locker with respect to the clamping angle of a locker, such as $3^{\circ},\;4^{\circ},\;5^{\circ},\;6^{\circ},\;$ using a pressure gauge, and compared the results with the FEA results.

  • PDF

The Effect of the Resistance of Wedge Frame on the Clamping Force of the Rail Clamp (쐐기프레임의 저항력이 레일클램프의 압착력에 미치는 영향)

  • Han Dong-Seop;Shim Jae-Joon;Lee Kwon-Hee;Han Geun-Jo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2006.06b
    • /
    • pp.355-360
    • /
    • 2006
  • The damping force of a jaw pad is determined by the displacements of main part when two lockers are locked, after the damping angle of a locker was set up in the wedge type rail damp for a container crane. In this time, of the resistance of wedge frame generates due to several factors, the damping angle of a locker to display the initial clamping force will be changed because of the reduction of displacement of extension bar. This resistance is determined by the eccentric distance between the roller and the wedge, and by the gap between the wedge frame and outer frame. In this study we measured the tensile force of both extension bar through the performance test of the prototype rail damp in order to evaluate the effect of the resistance of wedge frame on the damping force of the wedge type rail clamp.

  • PDF

Relationship between the Initial Clamping Force and the Sliding Distance of the Rail Clamp according to the Wedge Angle (쐐기각에 따른 레일클램프의 초기 압착력과 밀림거리 사이의 관계)

  • Han D.S.;Lee S.W.;Kwon S.K.;Han G.J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.379-380
    • /
    • 2006
  • In this study we dealt with the relationship between the initial clamping force and the sliding distance in the wedge type rail clamp. The sliding distance is determined by the wedge angle and the initial clamping force. In order to derive the relation formula between the wedge angle and the sliding distance, we ad opt 5-kinds of the wedge angle, such as 2, 4, 6, 8, $10^{\circ}$. And then we analyze the effect of the initial clamping force on the sliding distance.

  • PDF

Creative Design of the Wedge Type Rail Clamp to set the Initial Clamping Force (초기압착력 설정을 위한 쐐기형 레일클램프의 창의적 설계)

  • Han, Dong-Seop;Kim, Yong;Lee, Seong-Wook;Han, Geun-Jo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.6 no.3
    • /
    • pp.58-64
    • /
    • 2007
  • The clamping force of a jaw pad is determined by the displacements of main part when two lockers are locked, after the clamping angle of a locker was set up in the wedge type rail clamp for a container crane. In this time, if the resistance of wedge frame generates due to several factors, the clamping angle of a locker to display the initial clamping force will be changed because of the reduction of displacement of extension bar. This resistance is determined by the eccentric distance between the roller and the wedge, and by the gap between the wedge frame and outer frame. In this study we measured the tensile force of both extension bar through the performance test of the prototype rail clamp in order to evaluate the effect of the resistance of wedge frame on the clamping force of the wedge type rail clamp.

  • PDF

Effects of Preheating Treatment and Chitosan Addition on the Textural Properties of Korean Radish during Salting (무의 염장과정 중 조직감의 변화에 대한 예열처리 및 Chitosan 첨가효과)

  • Rhee, Hee-Seoup;Lee, Gui-Ju
    • Journal of the Korean Society of Food Culture
    • /
    • v.9 no.1
    • /
    • pp.53-59
    • /
    • 1994
  • This study was attempted to investigate the effects of preheating treatment and chitosan addition on the textural properties of Korean radish during salting. For this study, we determined the changes in textural properties by compression, puncture, cutting tests respectively and the changes in pectin fractions were also determined. Sensory parameters such as hardness, crispness and toughness were evaluated by sensory analysis and their results were correlated with those by Instron. The results were as follows. The compression force of nonpreheated Korean radish was increased by chitosan addition, whereas that of preheated one was decreased during salting. The puncture force from all the samples of Korean radish decreased, however, chitosan addition showed higher puncture force. The cutting force of nonpreheated Korean radish increased during salting and those from nonpreheated and preheated ones were increased by chitosan addition. During salting hot water soluble pectin(HWSP) of nonpreheated Korean radish increased and 0.4% Na-hexametaphosphate soluble pectin(HXSP) and 0.05 N-HCl soluble pectin(HCISP) decreased respectively. However, HXSP was decreased by preheating treatment. On the contrary, the results were reversed by chitosan addition. Hardness and crispness of nonpreheated Korean radish decreased and toughness increased respectively during salting. However, toughness was decreased by preheating treatment and hardness was increased by chitosan addition. Compression and puncture forces were highly correlated with sensory parameters such as hardness and crispness, whereas cutting force was more correlated with toughness. From these results, it seems that the textural properties were improved by chitosan addition in both nonpreheated and preheated Korean radish. The preheating treatment was effective in the early stage of salting. However, combination of both treatments showed little effect during salting.

  • PDF

Shape Optimization for a Jaw Using Design Of Experiments (실험계획법을 이용한 조(Jaw)의 형상최적설계)

  • Bang, Il-Kwon;Kang, Dong-Hun;Han, Dong-Seop;Han, Geun-Jo;Lee, Kwon-Hee
    • Journal of Navigation and Port Research
    • /
    • v.30 no.8 s.114
    • /
    • pp.685-690
    • /
    • 2006
  • The rail clamp is the device to prevent that a crane slips along rails due to the wind blast as well as to locate the crane in the set position for loading and unloading containers. The wedge typed rail clamp should be designed to consider the structural stability and the durability because it compresses both rail side with large clamping force by the wedge working as the wind speed increases. In this research, the design of experiments(DOE) and the variation technology(VT) built in ANSYS WORKBENCH are utilized to determine the optimum shape of a jaw. The optimum results obtained by two methods are compared and examined.

Shape Optimization for a Jaw Using DOE (실험계획법을 이용한 조(Jaw)의 형상최적설계)

  • Lee Kwon-Hee;Bang Il-Kwon;Han Dong-Seop;Han Geun-Jo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2006.06b
    • /
    • pp.331-336
    • /
    • 2006
  • The rail clamp is the device to prevent that a crane slips along rails due to the wind blast as well as to locate the crane in the set position for loading and unloading containers. The wedge type rail clamp should be designed to consider the structural instability and the durability because it compresses both rail side with large clamping force by the wedge working as the wind speed increases. In this research, there are two methods which are design of experiment and variation technology in used commercial software and shape optimization was performed. The optimum results obtained by the two methods are compared and examined.