• 제목/요약/키워드: 체적 열발생

검색결과 69건 처리시간 0.026초

정적연소실내의 디젤분무증발과 연소특성에 관한 연구 (A Study on the Diesel Spray Evaporation and Combustion Characteristics in Constant Volume Chamber)

  • 김상호;김석준;이만복;김응서
    • 한국자동차공학회논문집
    • /
    • 제2권6호
    • /
    • pp.102-109
    • /
    • 1994
  • As a fundamental study to apply high pressure injection system to direct injection diesel engine, fuel injection system and constant volume combustion chamber were made and the behaviors of evaporating spray with the variation of injection pressure and the ambient gas temperature were observed by using high speed camera, and the combusion characteristics with the variation of injection pressure and A/F ratio were analyzed. As injection pressure increases, spray tip penetration and spray angle increase and, as a results spray volume increases. This helps an uniform mixing of fuel and air. Spray liquid core length decreases as ambient gas temperature increases, while it decreases as injection pressure increases but the effect of ambient gas temperature is dorminant. As injection pressure increases, ignition delay is shortened and combustion rate being raised, maximum heat release rate increases. It become clear that High injection pressure has high level of potential to improve the performance of DI-diesel engine.

  • PDF

만리포 사빈의 시계열 3차원 지형 변화 분석 (Spatial-temporal Analysis of Topographical Change at the Malipo Beach)

  • 박한산
    • 한국지형학회지
    • /
    • 제20권1호
    • /
    • pp.97-109
    • /
    • 2013
  • 만리포 사빈에 대하여 지상라이다(Terrestrial LIDAR)로 2008년 12월부터 2010년 1월까지 6회 조사된 3차원 정밀 지형을 이용하여 정량적 지형특성과 변화량을 분석하였다. 만리포 사빈은 해발고도 0m에서 1.5m사이에 가장 넓게 분포하고 있으며, 평균고조위인 해발고도 2.25m 이상에서는 사빈의 면적이 급격이 줄어든다. 지형변화 특성으로는 침식과 퇴적이 해안선을 따라 선적으로 나타나고 있으며, 북쪽 지역이 남쪽 지역보다 그 경향이 강하게 나타난다. 계절적 변화 특성으로는 봄에서 가을까지는 전반적인 침식이, 겨울에는 상대적으로 많은 양의 침식과 퇴적이 발생하였으며, 조사 시작과 종료시점의 체적은 큰 차이가 없는 것으로 분석되었다.

CBT를 이용한 고체 추진제의 연소효율 도출 방법과 그레인 형상의 영향 분석 (Combustion Efficiency Estimation Method of Solid Propellants and the Effects of Grain Shape using Closed Bomb Test)

  • 박종근;성홍계;이원민;김은미
    • 한국추진공학회지
    • /
    • 제26권6호
    • /
    • pp.53-61
    • /
    • 2022
  • 본 연구에서는 CBT(Closed Bomb Test)시험을 통하여 고체추진제의 연소효율을 추정하는 방법을 제시하였다. CBT는 수백 기압에서 작동하므로 실기체의 영향을 고려하기 위해 Noble-Abel 상태방정식을 적용하였다. 또한 밀폐용기 벽면으로 발생하는 열손실을 고려하였다. 그레인의 연소로 인한 그레인의 체적 변화율 계산은 형상 함수(Form Function)를 적용하였으며, 총 8개의 다른 형태 그레인의 연소 효율을 도출하였다. 본 연구에서 제시한 이론모델의 적절성을 실험 결과인 압력-시간 선도와 비교하여 나타내었다. 그레인 형상과 추진제의 충진량에 따른 연소효율을 도출하였다.

터널 숏크리트 라이닝의 장기 화학적 열화 손상 평가를 위한 수치 모델링 기법 개발 (Development of a numerical modelling technique for evaluation of a long-term chemical deterioration of tunnel shotcrete lining)

  • 신휴성;김동규
    • 한국터널지하공간학회 논문집
    • /
    • 제9권3호
    • /
    • pp.299-307
    • /
    • 2007
  • 본 논문에서는 터널 숏크리트 라이닝의 장기 화학적 열화에 의한 물리적 손상을 수치적으로 모델링하기 위한 새로운 개념의 해석기법이 제안되었다. 이러한 물리적 손상은 내부균열 발생, 재료 강성과 강도의 저하에 의해 주로 유발되며, 이들은 장기 화학적 열화반응에 의한 체적팽창 및 시멘트질의 침식에 의해 발생된다. 결과적으로, 이러한 숏크리트 라이닝의 손상 메카니즘은 터널내에서 발생할 수 있는 다양한 종류의 열화반응들에서 유사하게 나타난다. 따라서, 본 연구에서는 일련의 화학적 열화 반응에 기인한 물리적 손상 메카니즘을 일반화 하였으며, 열역학에 기반한 수치모델을 수학적으로 유도 하였다. 유도된 수치모델은 3차원 유한요소 프로그램으로 코드화되었으며, 외력과 장기 화학적 열화를 겪고 있는 터널 구조물의 시간의존성 거동 시뮬레이션에 적용된다. 개발된 코드는 몇 개의 예제 수행을 통해 터널설계상에서의 적용성을 검토하였으며, 동일한 열화조건하에서도 주변 지반응력상태에 따라 물리적 손상 속도와 정도가 크게 달라짐을 보였다.

  • PDF

유한요소법과 실험계획법을 이용한 고온 열교환기용 S-관의 형상 최적화 (Shape Optimization of S-tube for Heat Exchanger Used in High Temperature Environment Using FE Analysis and DOE)

  • 정호승;조종래
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권4호
    • /
    • pp.497-503
    • /
    • 2012
  • 본 연구의 목적은 고온, 고압 환경에서 사용되는 열교환기의 전열관에서 발생되는 열팽창에 따른 열응력, 진동과 같은 기계적 특성을 개선시키고, 전열부 체적을 최소화시키는 관점에서 실험계획법을 이용하여 구불구불한 관 형상에 대하여 형상최적화를 수행하였다. S-관 형상에 대하여 부분별 용도를 제시하였고, 형상 최적화를 위해서 형상변수 및 범위를 정한 후, 유한요소해석을 수행하여 형상변수에 따른 구조적 특성을 평가하였고, 요인배치법을 이용하여 형상변수의 주효과를 분석한 후, 반응표면법(Response surface Methodology)을 이용하여 회귀방정식을 구하고, 최적화 툴을 이용하여 최적화를 수행하였다.

삼각형 형상의 풀 내에서 열원에 의한 자연대류 수치해석 (NATURAL CONVECTION IN A TRIANGULAR POOL WITH VOLUMETRIC HEAT GENERATION)

  • 김종태;박래준;김환열;송진호
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.302-310
    • /
    • 2011
  • A fluid in an enclosure can be heated by electric heating, chemical reaction, or fission heat. In order to remove the volumetric heat of the fluid, the walls surrounding the enclosure must be cooled. In this case, a natural convection occurs in the pool of the fluid, and it has a dominant role in heat transfer to the surrounding walls. It can augment the heat transfer rates tens to hundreds times larger than conductive heat transfer. The heat transfer by a natural convection in a regular shape such as a square cavity or semi-circular pool has been studied experimentally and numerically for many years. A pool of an inverted triangular shape with 10 degree inclined bottom walls has a good cooling performance because of enhanced boiling critical heat flux (CHF) compared to horizontal downward surface. The coolability of the pool is determined by comparing the thermal load from the pool and the maximum heat flux removable by cooling mechanism such as radiative or boiling heat transfer on the pool boundaries. In order to evaluate the pool coolability, it is important to correctly expect the thermal load by a natural convection heat transfer of the pool. In this study, turbulence models with modifications for buoyancy effect were validated for unsteady natural convections by volumetric heating. And natural convection in the triangular pool was evaluated by using the models.

  • PDF

열원이 있는 삼각형 풀의 높은 Ra수 자연대류 (HIGH Ra NUMBER NATURAL CONVECTION IN A TRIANGULAR POOL WITH A HEAT GENERATION)

  • 김종태;박래준;김환열;홍성완;송진호;김상백
    • 한국전산유체공학회지
    • /
    • 제16권3호
    • /
    • pp.66-74
    • /
    • 2011
  • A fluid in an enclosure can be heated by electric heating, chemical reaction, or fission heat. In order to remove the volumetric heat of the fluid, the walls surrounding the enclosure must be cooled. In this case, a natural convection occurs in the pool of the fluid, and it has a dominant role in heat transfer to the surrounding walls. It can augment the heat transfer rates tens to hundreds times larger than conductive heat transfer. The heat transfer by a natural convection in a regular shape such as a square cavity or semi-circular pool has been studied experimentally and numerically for many years. A pool of an inverted triangular shape with 10 degree inclined bottom walls has a good cooling performance because of enhanced boiling critical heat flux (CHF) compared to horizontal downward surface. The coolability of the pool is determined by comparing the thermal load from the pool and the maximum heat flux removable by cooling mechanism such as radiative or boiling heat transfer on the pool boundaries. In order to evaluate the pool coolability, it is important to correctly expect the thermal load by a natural convection heat transfer of the pool. In this study, turbulence models with modifications for buoyancy effect were validated for unsteady natural convections by volumetric heating. And natural convection in the triangular pool was evaluated by using the models.

상변화 물질을 이용한 전자 장비 방열 설계의 수치 해석적 연구 (Numerical Analysis for Thermal Design of Electronic Equipment Using Phase Change Material)

  • 이동균;이원희;박성우;강성욱;조지현
    • 대한기계학회논문집B
    • /
    • 제41권4호
    • /
    • pp.285-291
    • /
    • 2017
  • 본 연구에서는 무인 항공 장비에 장착되는 전자 장비에 상변화 물질을 적용한 방열 설계를 수치적으로 진행하였다. 상변화 물질에 대한 열특성 실험을 통해 용융점($T_m$), 용융시 온도 증분(${\Delta}T_m$) 및 체적 팽창을 확인하였으며, 이를 통해 해석 모델 검증을 진행하였다. 용융시 용융점에서 발생하는 온도 정체 현상을 모사하기 위해 등가 비열법으로 계산한 열 물성치를 상변화 물질의 해석 모델 물성치로 입력하였으며, 실험 결과와의 비교를 통해 해석 모델의 신뢰성을 검증하였다. 검증된 해석 모델을 통해 핀과 함께 상변화 물질이 충진된 장비 하우징의 방열 성능을 향상시키고, 이를 통해 장비의 열적 안정성을 확보하였다. 현재 상변화 물질이 충진된 하우징의 방열 성능 극대화를 위해 핀 최적 설계에 대한 추가적인 연구가 진행 중에 있다.

펠티어 소자를 이용한 40[W]급 LED 조명기구의 방열에 관한 연구 (Research on Heat-Sink of 40Watt LED Lighting using Peltier Module)

  • 어익수;양해술;최세일;황보승
    • 한국산학기술학회논문지
    • /
    • 제8권4호
    • /
    • pp.733-737
    • /
    • 2007
  • 본 논문은 MCPCB에 다수의 와트급 LED를 모듈화하여 조명기구로 사용함에 따라 발생하는 열을 해결하기 위한 제안이다. LED가 조명기구로 사용되려면 칩의 용량이 커야하며 이 결과 P-N접합부의 열이 증가하게 됨으로 이를 해결하기 위해 펠티어 소자와 방열판 그리고 Fan을 설치하여 온도변화특성을 측정하였다. 또한 부가적으로 냉각소자와 방열판을 접속하는 열전도판, 단열재, Thermal Grease에 따른 온도변화특성을 실험하였다. 그 결과 방열판의 종류 및 체적에 따른 온도 변화가 가장 중요한 요소로 나타났다. Fan의 on, off에 따른 온도변화는 최대 $18[^{\circ}C]$의 변화폭을 주었으며 부가적 재료들도 $2{\sim}3[^{\circ}C]$의 온도변화에 영향을 주어 무시할 수 없는 요소임을 확인하였다.

  • PDF

BGK 수치기법을 이용한 로켓 노즐 내의 유동장 해석

  • 신동신;이재성
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2000년도 제14회 학술강연논문집
    • /
    • pp.16-16
    • /
    • 2000
  • 충격파를 포함하는 초음속 유동을 해석하는 수치해법 중에서 많이 사용되어진 것은 엄밀 및 근사 리만 해법과 플럭스 분할 기법들로서 이들은 Euler 방정식에 기반을 두고 선형 또는 비선형파의 상호작용을 풍상 차분법으로 기술하는 방법들이다. 이러한 수치기법들은 과거 광범위하게 사용되어 왔으나 최근 여러 가지 단점이 발견되었다. 이와 같은 문제점을 극복하고자 입자의 통계적인 운동을 기술하는 기체 운동론에 근거하여 BGK 수치기법이 제시되었다. 이는 비충돌 볼츠만 방정식으로부터 입자의 수준에서 플럭스 분할 기법 형태의 풍상차분법을 구현하는 것으로 볼츠만 방정식의 충돌항을 BGK 모델로 대치하고 이것의 적분해로부터 수치 플럭스를 구한다. 이 수치기법은 기존의 리만해법에 비하여 수치적으로나 물리적으로 매우 타당한 성질인 강건성, 정확성, 엔트로피 조건, 양수보존성 등을 가지고 있음이 밝혀졌다. 이와 같은 수치기법을 사용하여 로켓 노즐 내의 아음속, 천이음속, 초음속에서의 유동장 해석을 위한 프로그램을 작성하였다. 시간 적분에 대하여는 정상 상태의 계산을 위하여 내재적 시간 적분 방법을 사용하였으며, 공간 이산화 방법으로는 임의의 제어체적에 대하여 적분형 보존 방정식을 적용하는 유한 체적법을 사용하였다. 초음속 입구 유동과 출구에서 초음속과 저음속 유동의 두가지 경우를 고려하여 얻은 결과를 기존의 연구 결과와 비교하여 본 결과 잘 일치하였다. 입구 유동이 저음속이고 출구 유동이 초음속인 경우에 대하여도 해석결과가 실험결과와 잘 일치하였다. 상대적으로 낮은 온도, 압력 조건과 높은 온도, 압력 조건을 가지는 고체 로켓 모터 노즐 내의 유동을 해석하였다. 이들 해석 결과를 전압, 전온도로 표준화시킨 결과 서로 일치하였으며, 파라서 저온, 저압에서 얻은 결과도 표준화시킬 경우, 고온, 고압에서도 사용될 수 있음을 알 수 있었다.의 영향에 초점을 맞추었다.다고 판단되며 배기 가스 자체에 대기 공기중에 함유되어 있던 습기가 얼어붙는(Icing화) 문제가 발생하기 때문에 배기가스의 Icing을 방지하기 위하여 압축기 끝단에서 공기를 추출하여 배기부분에 송출할 필요성이 있는 것으로 판단되었다. 출구가스의 기체 유동속도가 매우 빠르므로 (100-l10m.sec) 이를 완화하기 위한 디퓨저의 설계가 요구된다고 판단된다. 또 연소기 후방에 물을 주입하는 경우 열교환기 및 기타 부분품에 발생할 수 있는 부식 및 열교환 효율 저하도 간과할 수 없는 문제로 파악되었다. 이러한 기술적 문제가 적절히 해결되는 경우 비활성 가스 제너레이터는 민수용으로는 대형 빌딩, 산림, 유조선 등의 화재에 매우 적절히 사용되어 질 수 있을 뿐 아니라 군사적으로도 군사작전 중 및 공군 기지의 화재 그리고 지하벙커에 설치되어 있는 고급 첨단 군사 장비 등의 화재 뿐 아니라 대간첩작전 등에 효과적으로 활용될 수 있을 것으로 판단된다.가 작으며, 본 연소관에 충전된 RDX/AP계 추진제의 경우 추진제의 습기투과에 의한 추진제 물성 변화는 미미한 것으로 나타났다.의 향상으로, 음성개선에 효과적이라고 사료되었으며, 이 방법이 편측 성대마비 환자의 효과적인 음성개선의 치료방법의 하나로 응용될 수 있으리라 생각된다..7%), 혈액투석, 식도부분절제술 및 위루술·위회장문합술을 시행한 경우가 각 1례(2.9%)씩이었다. 13) 심각한 합병증은 9례(26.5%)에서 보였는데 그중 식도협착증이 6례(17.6%), 급성신부전증 1례(2.9%), 종격동기흉과 폐염이 병발한 경우와 폐염이 각 1례(2.9%)였다. 14) 식도경 시행회수는 1회가 17례(54.8%), 2회가 9례(29.0%), 3회 이상이 5례(16.1%)였다.EX>$IC_{50}$/ 값이 210 $\mu\textrm{g}$<

  • PDF