Prediction of Pressurant Mass Requirement for Propellant Tank with Operating Condition Variation (운용조건 변화에 따른 추진제탱크 가압가스 요구량 예측)

  • Kwon, Oh-Sung;Han, Sang-Yeop;Cho, In-Hyun
    • Aerospace Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.54-62
    • /
    • 2011
  • The pressurant mass required for propellant tank pressurization with operating condition variation was estimated by using the numerical model already developed for this purpose. The model was applied to the concept design results of KSLV-II first stage oxygen tank. The supplied pressurant temperature, oxygen volumetric flow rate, and the ratio of length to diameter of the tank were selected as variables. The required pressurant mass and mass flow rate, collapse factor, ullage temperature distribution were predicted, and the results showed that the pressurant temperature had the largest effect on the amount of the required pressurant mass. The pressurizing efficiency of the propellant tank was calculated through analyzing energy distribution in the ullage. It was found that the gas-to-wall heat transfer in the ullage was dominant, and much of the pressurant energy was lost to tank wall heating.

Experimental/ Computational Study on the Passive Control of Supersonic Cavity Flow using a Sub-Cavity (Sub-cavity를 이용한 초음속 cavity 유동의 피동제어에 대한 실험 및 수치해석적 연구)

  • Lim, Chae-Min;Lee, Young-Ki;Kim, Heuy-Dong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.04a
    • /
    • pp.295-298
    • /
    • 2007
  • The effectiveness of passive control techniques for reducing the pressure oscillation generated in a supersonic cavity flow was investigated numerically and experimentally, respectively. The control device includes a sub-cavity installed in the upstream edge of a rectangular cavity. Time-dependent supersonic cavity flow characteristics with turbulent features were examined by using the three-dimensional, mass-averaged Navier-Stokes computation based on a finite volume scheme and large eddy simulation. The results show that the pressure oscillation near the trailing edge dominates overall time-dependent cavity pressure variations. Such an oscillation can be attenuated more significantly in the presence of the sub-cavity compared with the cavity without sub-cavity, and a larger sub-cavity leads to better control performance.

  • PDF

A Deformation Model of a Bag-Finger Skirt and the Motion Response of an ACV in Waves (Bag-Finger형 스커트의 변형모델과 규칙파중 공기부양선의 운동해석)

  • G.J. Lee;K.P. Rhee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.29 no.2
    • /
    • pp.48-59
    • /
    • 1992
  • In this paper, the effects of a skirt deformation on the responses of an Air Cushion Vehicle in waves are investigated. The air in the bag and in the plenum chamber is assumed to be compressible and to have a uniform instantaneous pressure distribution in each volume. The free surface deformation is determined in the framework of linear potential theory by replacing the cushion pressure with the pressure patch moving uniformly with an oscillating strength. And the bag-finger skirt is assumed to be deformed due to the pressure disturbance while its surface area remained constant. The restoring force and moment due to the deformation of bag-finger skirt from the equilibrium shape is included in the equations of hearse and pitch motions. The numerical results of motion responses due to various ratios of the bag and cushion pressure or bag-to-finger depth ratios are shown.

  • PDF

Numerical Simulation of Axisymmetric Supersonic let Impingement on a Flat Plate (수직평판에 충돌하는 축대칭 초음속 제트의 수치 연구)

  • 신완순;이택상;박종호;김윤곤;심우건
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.4 no.3
    • /
    • pp.11-18
    • /
    • 2000
  • When supersonic underexpanded jets are exhausted from the nozzle, complex shock cell configurations such as barrel shock, expansion fan, Mach disc, and exhaust-gas jet boundary are appeared repetitively. The shock cell is smeared by turbulence dissipation and disappeared in long distance from the nozzle. When underexpanded jet is suddenly impinged on a flat plate, it forms very complex flow structure. In this paper, we solve compressible Wavier-Stokes equation adapting finite volume method to obtain jet impingement flow structure and compare calculated data with experimental ones. It is shown that numerical simulation data are in good agreement with experimental one in a short distance between nozzle exit and flat plate and little influence of underexpanded ratio is appeared in jet impingement now distribution.

  • PDF

RELAP5/MOD3 Analysis for Hydraulic Load Calculation of the SEBIM POSRV Discharge Riping System (SEBIM POSRV 방출배관계통의 수력학적 하중계산을 위한 RELAP5 / MOD3 분석)

  • Han, Kee-Soo;Song, Jin-Ho
    • Nuclear Engineering and Technology
    • /
    • v.26 no.2
    • /
    • pp.225-236
    • /
    • 1994
  • The sudden discharge of the loop seal water, which is present upstream of the SEBIM POSRV, creates large momentum and inertia forces on the downstream of the discharge piping system. This study provides the procedures and results of analysis of the thermal-hydraulic transient in the SEBIM POSRV discharge piping during the valve opening. The analysis is peformed by RELAP5/MOD3. The appropriate modeling of the discharge piping system, SEBIM POSRV opening characteristics, and loop seal water discharge for the RELAP5/MOD3 analysis is suggested. Also performed is the sensitivity study for the selection of proper options for the junction and volume control. flags. The analysis results demonstrate the adequacy of the RELAP5/HOD3 for the thermal-hydraulic transient analysis of the loop seal water discharge of the SEBIM POSRV discharge piping system. From the sensitivity analysis results, it is shown that the smooth area change option with reasonable geometric pressure drop distribution, non-equilibrium option, and proper time step should be selected for loop seal water discharge analysis.

  • PDF

A Molecular Dynamics Study on the Liquid-Glass-Crystalline Transition of Lennard-Jones System (한 Lennard-jones 시스템의 액체-유리-결정 전이에 관한 분자동역학 연구)

  • Chang, Hyeon-Gu;Lee, Jong-Gil;Kim, Sun-Gwang
    • Korean Journal of Materials Research
    • /
    • v.8 no.8
    • /
    • pp.678-684
    • /
    • 1998
  • By means of constant- pressure molecular dynamics simulations, we studied the liquid- glass- crystalline transition of a system composed of Lennard- Jones particles with periodic boundary conditions. Atomic volume and enthalpy were calculated as functions of temperature during heating and cooling processes. The Wendt- Abraham ratio derived from radial distribution function and the angular distribution function characterizing short range order were analyzed to distinguish between liquid, glass and crystalline states. A liquid phase resulting from a slow heating of an initial fee crystal amorphized on fast quench, but it crystallized on slow quench. When slowly heated, the amorphous phase from fast quench crystallized into an fee structure. A system with free surface was shown to melt from the surface inward at a lower temperature than bulk system and to have a strong tendency for crystallization even during a fast quench from a liquid state.

  • PDF

Analysis of the Creep Effect on the Dural-sac Occlusion in the Lumbar Spinal Motion Segment (크?현상이 요추 운동분절내의 척추경악 교합에 미치는 영향 해석)

  • 김영은;조성윤
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.6
    • /
    • pp.551-557
    • /
    • 2001
  • Occlusion of the dural-sac in the lumbar spine was quantitatively analysed using a one motion segment finite element mode developed in this study. Occlusion was quantified by calculating the cross sectional area chance of the dural-sac. In static analysis. less than 2 kN of compressive load could Produced no dural-sac occlusion. whereas 6kN load reduced cross sectional area by 4%, and produced 7.4%, 10.5% occlusion for additional 8 Nm. 10 Nm extension moments. respectively. In creep analysis, 10 Nm extension reduced cross sectional area and volume of the dural-sac by 6.9% and 2.4%, respectively. However. flexion moment could not produce any occlusion. The results suggested that occlusions may result mainly from slackening of ligamentum flavum and disc budging.

  • PDF

Numerical Analysis for Thermal Design of Electronic Equipment Using Phase Change Material (상변화 물질을 이용한 전자 장비 방열 설계의 수치 해석적 연구)

  • Lee, Dong Kyun;Lee, Won Hee;Park, Sung Woo;Kang, Sung Wook;Cho, Ji Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.4
    • /
    • pp.285-291
    • /
    • 2017
  • In this study, a case analysis for thermal design of electronic equipment using a phase change material(PCM) was performed numerically using ANSYS Fluent. Experiments were conducted to find the temperature increase(${\Delta}T_m$), melting temperature($T_m$), and volume expansion of the PCM under the melting process. To verify the accuracy of the Fluent solver model, $T_m$, ${\Delta}T_m$, and the melting time were compared with experimental results. To simulate the temperature stagnation phenomenon under the melting process, the equivalent specific heat method was applied to calculate the thermal properties of the PCM in the solver model. To determine the thermal stability of electronic equipment, we paid special attention to finding a thermal design for the PCM using fins. Further, an additional numerical analysis is currently underway to find an optimum design.

Performance analysis of a cold-air forced circulation type showcase (냉기 강제순환형 공랭식 쇼케이스 성능 해석)

  • Kim, Jeong-Sik;Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.3
    • /
    • pp.1003-1010
    • /
    • 2013
  • In this study, a simulation program was developed, which predicts the performance of cold-air forced circulation type air cooled showcase. The showcase has an excellent display effect in addition to preserving the grocery. In the program, the compressor was analyzed using performance data supplied by the manufacturer and the capillary tube pressure drop was analyzed using a homogeneous model. The evaporator and condenser were analyzed by dividing the heat exchangers into small elements, where energy balance and appropriate heat transfer correlations were used. A showcase model with two 3/4 HP compressors, capillary tubes of 1.6 mm inner diameter, a fin-and-tube evaporator and condenser was tested, and the results are compared with the predicted values. It is shown that both evaporation and condensation temperatures are adequately predicted by the program.

A Preliminary Study on Reduction of Shrinkage Stress in Concrete Slabs (콘크리트 슬래브 건조수축 응력 감소에 관한 초기연구)

  • Park, Jeong-Woo;Jeong, Young-Do;Lim, Jin-Sun;Jeong, Jin-Hoon
    • International Journal of Highway Engineering
    • /
    • v.11 no.4
    • /
    • pp.87-94
    • /
    • 2009
  • Volume of concrete slab changes by variations of temperature and moisture after its placement. Shrinkage due to evaporation causes tensile stress in the slab when contraction of the slab is restrained by its self weight, friction with subbase, and etc. Actual tensile stress caused by the shrinkage was less than theoretically predicted stress according to previous studies. It was the stress reduction due to visco-elastic property of the early-age concrete slab partially restrained. In this study, strains of restrained circumferential, unrestrained circumferential, and unrestrained square pillar concrete specimens were measured to investigate stress reduction of the specimens with age of concrete. Elastic modulus of the concrete was measured at the age of 1, 3, 7, 14, 28 days and penetration test was performed. The stress reduction was calculated by input the test results into theoretical equations suggested by previous researchers. The stress reduction of the restrained concrete specimens will be applied to design of concrete pavements based on results of the study.