• Title/Summary/Keyword: 체외 방사선 조사

Search Result 25, Processing Time 0.019 seconds

Evaluation of Biological Characteristics of Neutron Beam Generated from MC50 Cyclotron (MC50 싸이클로트론에서 생성되는 중성자선의 생물학적 특성의 평가)

  • Eom, Keun-Yong;Park, Hye-Jin;Huh, Soon-Nyung;Ye, Sung-Joon;Lee, Dong-Han;Park, Suk-Won;Wu, Hong-Gyun
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.280-284
    • /
    • 2006
  • $\underline{Purpose}$: To evaluate biological characteristics of neutron beam generated by MC50 cyclotron located in the Korea Institute of Radiological and Medical Sciences (KIRAMS). $\underline{Materials\;and\;Methods}$: The neutron beams generated with 15 mm Beryllium target hit by 35 MeV proton beam was used and dosimetry data was measured before in-vitro study. We irradiated 0, 1, 2, 3, 4 and 5 Gy of neutron beam to EMT-6 cell line and surviving fraction (SF) was measured. The SF curve was also examined at the same dose when applying lead shielding to avoid gamma ray component. In the X-ray experiment, SF curve was obtained after irradiation of 0, 2, 5, 10, and 15 Gy. $\underline{Results}$: The neutron beams have 84% of neutron and 16% of gamma component at the depth of 2 cm with the field size of $26{\times}26\;cm^2$, beam current $20\;{\mu}A$, and dose rate of 9.25 cGy/min. The SF curve from X-ray, when fitted to linear-quadratic (LQ) model, had 0.611 as ${\alpha}/{\beta}$ ratio (${\alpha}=0.0204,\;{\beta}=0.0334,\;R^2=0.999$, respectively). The SF curve from neutron beam had shoulders at low dose area and fitted well to LQ model with the value of $R^2$ exceeding 0.99 in all experiments. The mean value of alpha and beta were -0.315 (range, $-0.254{\sim}-0.360$) and 0.247 ($0.220{\sim}0.262$), respectively. The addition of lead shielding resulted in no straightening of SF curve and shoulders in low dose area still existed. The RBE of neutron beam was in range of $2.07{\sim}2.19$ with SF=0.1 and $2.21{\sim}2.35$ with SF=0.01, respectively. $\underline{Conclusion}$: The neutron beam from MC50 cyclotron has significant amount of gamma component and this may have contributed to form the shoulder of survival curve. The RBE of neutron beam generated by MC50 was about 2.2.

Possibility of Cancer Treatment by Cellular Differentiation into Adipocytes (지방세포로의 분화를 통한 악성 종양의 치료 가능성)

  • Byeong-Gyun Jeon;Sung-Ho Lee
    • Journal of Life Science
    • /
    • v.33 no.6
    • /
    • pp.512-522
    • /
    • 2023
  • Cancer with unlimited cell growth is a leading cause of death globally. Various cancer treatments, including surgery, chemotherapy, radiation therapy, immunotherapy, and targeted therapy, can be applied alone or in combination depending on the cancer type and stage. New treatments with fewer side effects than previous cancer treatments are continually under development and in demand. Undifferentiated stem cells with unlimited cell growth are gradually changed via cellular differentiation to arrest cell growth. In this study, we reviewed the possibility of treating cancer by using cellular differentiation into the adipocytes in cancer cells. In previous in vitro studies, oral antidiabetic drugs of the thiazolidinedione (TDZ) class, such as rosiglitazone and pioglitazone, were induced into the adipocytes in various cancer cell lines via increased peroxisome proliferator-activated receptor-γ (PPAR γ) expression and glucose uptake, which is the key regulator of adipogenesis and the energy metabolism pathway. The differentiated adipogenic cancer cells treated with TDZ inhibited cell growth and had a less cellulotoxic effect. This adipogenic differentiation treatment suggests a possible chemotherapy option in cancer cells with high and abnormal glucose metabolism levels. However, the effects of the in vivo adipogenic differentiation treatment need to be thoroughly investigated in different types of stem and normal cells with other side effects.

Usefulness of Pulsatile Flow Aortic Aneurysm Phantoms for Stent-graft Placement (스텐트그라프트 장치술을 위한 대동맥류 혈류 팬텀의 유용성)

  • Kim, Tae-Hyung;Ko, Gi-Young;Song, Ho-Young;Park, In-Kook;Shin, Ji-Hoon;Lim, Jin-Oh;Kim, Jin-Hyoung;Choi, Eu-Gene K.
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.205-212
    • /
    • 2007
  • To evaluate the feasibility and efficacy of a pulsatile aortic aneurysm phantoms for in-vitro study. The phantoms consisted of a pulsating motor part(heart part) and an aortic aneurysm part, which mimicked true physiologic conditions. The heart part was created from a high-pressured water pump and a pulsatile flow solenoid valve for the simulation of aortic flow. The aortic aneurysm part was manufactured from paper clay, which was placed inside a acrylic plastic square box, where liquid silicone was poured. After the silicone was formed, the clay was removed, and a silicone tube was used to connect the heart and aneurysm part. We measured the change in pressure as related to the opening time(pulse rate, Kruskal-Wallis method) and pressure before and after the stent-graft implantation(n = 5, Wilcoxon's signed ranks test). The changes in blood pressures according to pulse rate were all statistically significant(p<0.05). The systolic/diastolic pressures at the proximal aorta, the aortic aneurysm, and the distal aorta of the model were $157.80{\pm}1.92/130.20{\pm}1.92$, $159.40{\pm}1.14/134.00{\pm}2.92$, and $147.20{\pm}1.480/129.60{\pm}2.70\;mmHg$, respectively, when the pulse rate was 0.5 beat/second. The pressures changed to $161.40{\pm}1.34/90.20{\pm}1.64$, $175.00{\pm}1.58/93.00{\pm}1.58$, and $176.80{\pm}1.48/90.80{\pm}1.92\;mmHg$, respectively, when the pulse rate was 1.0 beat/second, and $159.40{\pm}1.82/127.20{\pm}1.48$, $166.60{\pm}1.67/138.00{\pm}1.87$, and $161.00{\pm}1.22/135.40{\pm}1.67\;mmHg$, respectively, when it was 1.5 beat/second. When pulse rate was set at 1.0 beat/second, the pressures were $143.60{\pm}1.67/90.20{\pm}1.64$, $147.20{\pm}1.92/84.60{\pm}1.82$, and $137.40{\pm}1.52/88.80{\pm}1.64\;mmHg$ after stent-graft implantation. The changes of pressure before and after stent-graft implantation were statistically significant(p<0.05) except the diastolic pressures at the proximal(p =1.00) and distal aorta(p=0.157). The aortic aneurysm phantoms seems to be useful for the evaluation of the efficacy of stent-graft before animal or clinical studies because of its easy reproducibility and ability to display a wide range of pressures.

  • PDF

Histologic Change of Extracorporeal Irradiated Autogenous Joint Transplantation in Rabbit's Knee (가토에서 체외 방사선 조사후 재이식한 자가관절의 조직학적 변화)

  • Kim, Jae-Do;Cho, Myung-Rae;Yoo, Kyung-Sik;Kim, Young-Chang
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.5 no.1
    • /
    • pp.9-16
    • /
    • 1999
  • A new method of limb sparing by resection, extracorporeal irradiation and reimplantation has several theoretical advantages. This method preserves the mobility of a joint and avoids the problem of loosening or breakage of tumor prosthesis. This study involved using extracorporeal irradiated autogenous joint transplantation for reconstruction after en bloc resection, and observed the periods of functional union and histological changes in irradiated tissue of the knee joint. This study also aimed to clarify whether the degeneration of articular cartilage is induced in rabbits by a single 50Gy dose of irradiation at the knee joint. Twenty New Zealand rabbits about three kilograms were randomized into two groups of 10 rabbits each. In group 1, as control, we resected the knee joint followed by reimplantation without irradiation. Group 2 received extracorporeal irradiation on the resected knee joint followed by reimplantation. Following are the results of these observations. The osteotomy site showed external callus formation in the roentgenographic finding eight weeks after reimplantation. There was marked degenerative changes in the collagen fiber of the irradiated anterior cruciate ligament and meniscus during the fourth week, but new blood-vessel formation was observed in the vicinity. There was degenerative changes in the collagen fiber of articular cartilage treated extracorporeal irradiation at four and eight weeks in the scanning electron micrographic findings. These findings was in contrast to those of subchondral bone which showed decreased cellularity and empty lacuna at four and eight weeks. Autoradiography demonstrated active [$^3H$]uridine incorporation by irradiated chondrocyte at eight weeks after reimplantation. These results indicate that when destruction of the articular cartilage and soft tissue of the knee joint is not severe, extracorporeal irradiation and reimplantation can be used with several advantage in maintaining movement of the joint while avoiding problems of tumor prosthesis and rejection, and therefore extracorporeal irradiated autogenous joint transplantation can be used as a limb-sparing procedure for temporary biological spacer in the childhood bone tumor around the knee.

  • PDF

Surgical Treatment of Metastatic Tumor in Proximal Femur with Recycling Autograft Prosthetic Composite after Wide Excision (근위 대퇴골 전이성 종양의 수술적 치료로서 광범위 절제술 후 재활용 자가골을 이용한 복합 고관절 성형술)

  • Kim, Jae-Do;Park, Pil-Jae;Kwon, Young-Ho;Jang, Jae-Ho;Lee, Young-Gu
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.11 no.1
    • /
    • pp.71-81
    • /
    • 2005
  • Purpose: Due to local recurrence of tumor, metal failure usually develops in patients who underwent internal fixation or hip joint arthroplasty after curettage in the case of metastatic tumor of proximal femur. The aim of this study is to find out the appropriateness of reconstruction using recycling autograft after wide excision in the case of metastatic bone tumor by performing recycling autograft and hip joint arthroplasty after wide excision, and through presence or absence of local recurrence, functions of lower limbs and occurrence of complications. Materials and Methods: Five patients, in 6 cases, who had undergone reconstruction using recycling autograft prosthetic composite after wide excision in the metastatic tumor from May 2000 to May 2003 were included in this study. The average age of the patients was 60.8 years of age with male to female ratio of 3:2. Average duration of lives following surgery was 23.3 month (7-57 months). Primary lesion included 2 cases of lung cancer, and 1 each of stomach cancer, renal cancer and multiple myeloma. After wide excision, the hip joint was reconstructed with recycling autograft prosthetic composite ; 4 cases of extracorporeal irradiation and 2 cases of pasteurization. Musculoskeletal Tumor Society (MSTS) score(1993) for 6-month period after surgery, as well as presence of complication and local recurrence during the rest of their lives, were studied. Results: Average Musculoskeletal Tumor Society (MSTS) score over the 6-month period after surgery was 63.3% and 1 case of dislocation of hip joint, as a complication following surgery, was discovered. Local recurrence during the lives of the patients was not observed. Conclusion: In the case of metastatic tumor of proximal femur, in which the life span following surgery is expected to be more than 6 months, undergoing reconstruction using recycling autograft after wide excision, in comparison to internal fixation or hip joint arthroplasty after curettage, is deemed to have better results in prevention of local recurrence, and preservation of the functions of all limbs during the life span of the patient.

  • PDF