• Title/Summary/Keyword: 체류 시간

Search Result 985, Processing Time 0.031 seconds

Ammonia Removal by using RBC in Recirculating Aquaculture System (RBC를 이용한 양어장수 암모니아 제거)

  • KIM Byong-Jin;LIM Sung-Il;SUH Kuen-Hack
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.31 no.5
    • /
    • pp.622-630
    • /
    • 1998
  • Rotating Biological Contactor (RBC) was tested for the removal of total ammonia nitrogen (TAN) by using simulated aquaculture system. RBC performance was evaluated by controlling revolution rate of disk and hydraulic residence tile (HRT). The optimum revolution rate of disk was 4 rpm, As HRT of RBC was increased, TAN removal efficiency of RBC and TAN concentration of rearing water were increased. HRT for maintaining lowest TAN concentration of rearing water was 9.5 minutes and at that condition TAN concentration of rearing tank was $1.03 g/m^3$

  • PDF

The Effect of Hydraulic Retention Time on The Power Density in a Horizontal Flow Microbial Fuel Cell (수평 흐름형 미생물 연료전지에서 수리학적 체류시간이 전력수율에 미치는 영향)

  • Lee, Chae-Young;Park, Su-Hee;Woo, Jeong-Hei;Yoo, Kyu-Seon;Jeong, Jea-Woo;Song, Youn-Chae
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.19 no.1
    • /
    • pp.109-114
    • /
    • 2011
  • This study was conducted to investigate the effect of hydraulic retention time(HRT) on the power density in a horizontal flow microbial fuel cell(MFC) reactor. When HRTs were 15min, 30min, 60min and 180min, maximum power densities were $24.7mW/m^2$, $27.3mW/m^2$, $22.8mW/m^2$ and $17.2mW/m^2$, respectively. The highest power density was obtained at HRT of 30min. It was 59% improvement when compared to the power density at an HRT of 180min. When HRT was increased, COD removal rate increased whereas the coulombic efficiency remained constant. The result shows that the optimal performance of the horizontal flow MFC reactor could be achieved at HRT of 30min.

Application of Subsurface Flow Wetland using the Phragmites australis for Water Quality Improvement of the Agricultural Reservoi (농업용 저수지 수질개선을 위한 지하흐름 갈대 인공습지의 적용)

  • Nam, Gui Sook;Pae, Yo Sop;Kim, Hyung Joong;Lee, Sang Joon;Lee, Gwang Sik
    • Journal of Wetlands Research
    • /
    • v.6 no.4
    • /
    • pp.59-69
    • /
    • 2004
  • Constructed wetlands are regarded as an important water treatment system for agricultural water quality improvement and management. The purpose of this study is to evaluate the application of subsurface flow wetland(SFW), using the Pharagmites australis as macrophytes, and to clarify the basic and essential factors to be considered in the construction and management of constructed wetlands. This study was carried out relatively short hydraulic residence time(HRT), 6hr ~ 72hr (3days), using eutrophic reservoir water with relatively low concentrations of influent and large quantity to be treated. The effluent satisfied the criteria of agricultural water quality. Removal efficiencies of Biochemical oxygen demand(BOD), Chemical oxygen demand(COD), Suspended solids(SS) and Chlorophyll a(Chl-a) were high in HRT 24hr, not any more significant increasement of removal efficiencies in HRT 48hr and 72hr. However, removal efficiencies of nitrogen and phosphorus increased as HRT increased, showing the highest efficiency at the 72hr of HRT in nitrogen, and 48hr in phosphorous. The SFW was very effective system for reservoir water quality improvement, and had the advantages of the reduction of purchasing cost to land required, lack of odors, and harmful insects, especially mosquito, the improvement of the scenic beauty and minimal risk of public exposure. Therefore, it was evaluated that the SFW was very available water treatment system for the water quality improvement of agricultural reservoir. However, it was need to consider with application of the SFW in high cost of construction and troublesome of management.

  • PDF

Estimation on Average Residence Time of Particulate Matters in Geoje Bay using Particle Tracking Model (입자추적모델을 이용한 거제만의 입자물질 평균체류시간 산정)

  • Kim, Jin-Ho;Hong, Sok-Jin;Lee, Won-Chan;Kim, Jeong-Bae;Kim, Hyung-Chul;Kim, Dong-Myung
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.1
    • /
    • pp.20-26
    • /
    • 2016
  • The residence time measures the time spent by a water parcel or a pollutant in a given water body. So residence time of water is widely used as an indicator of how a substance will remain in an estuary and it is used to enable comparisons among different water bodies. To estimate residence time of particulate matters from land and aquaculture, EFDC that includes particle tracking model was applied to the Geoje Bay. Modelled average residence time was about 65 days in the inner part. It meant it takes about 2 months for substance from land and aquaculture to be transported to the outside of Geoje Bay. The results indicated that residence time varied spatially throughout Geoje Bay depending on tidal flushing and, in general conditions, tidal flushing exerts the greatest influence to the flushing of Geoje Bay. This reveals relationships between residence times of particulate matters and physical properties of the bay and Geoje Bay is vulnerable to water quality problem.

Effect of Heat Treatment Condition on Tensile Strength of Glass Fibers (유리섬유의 열처리조건이 섬유 인장강도에 미치는 영향)

  • 이재락;오진석;박수진;김영근
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.10a
    • /
    • pp.257-260
    • /
    • 2002
  • 자체적으로 방사된 C-유리섬유와 E-유리섬유의 최적 싸이징제 제거 열처리온도조건을 알아보기 위하여 대류오븐에서 100, 200, 300, 그리고 $400^{\circ}C$에서 2, 4, 8, 16, 32, 64 그리고 128분 동안 체류한 섬유의 인장강도를 측정하였다. 그리고 다른 열처리조건으로 325, 350, 375 그리고 $400^{\circ}C$$25^{\circ}C$씩 증가시켜 처리시간은 1.5, 3, 6, 12, 24, 48 그리고 96시간을 선택하여 섬유의 인장강도 변화를 측정하였다. C-유리섬유의 경우 열처리에 의한 인장강도 감소가 최대 1.8%정도 였다. E-유리섬유의 열처리에 의한 인장강도의 감소률은 최대 약 1%정도였다. C-유리섬유의 경우 열처리 온도가 짧은 시간과 긴체류시간에서 일정한 영향을 미쳤다. 즉 높은 열처리 온도에서 높은 인장강도 감소를 나타내었다. 그 반면 E-유리섬유의 경우 짧은 체류시간에 있어서는 C-유리섬유와 유사한 특성을 나타내었으나 긴체류 시간에 있어서는 열처리 온도조건에 의한 영향이 극히 미미하였다.

  • PDF

Performance Improvement of Fast Handoff Using Mobility Prediction (이동성 예측을 통한 Fast Handoff 성능 개선 방안)

  • 김대선;홍충선
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2003.04d
    • /
    • pp.590-592
    • /
    • 2003
  • 본 논문에서는 대역폭 예약을 통한 무선 단말의 이동성 예측기법, 무선 단말의 이동 패턴을 이용한 이동성 예측기법과 무선 단말의 이동 패턴과 체류시간을 이용한 이동성 예측기법에 대하여 살펴본다. 대역폭 예약을 통한 이동성 예측기법에서의 자원 낭비 해결 방안과 이동 패턴 및 단말의 체류시간을 이용한 이동성 예측기법에서의 무선 단말의 셀에 장기간 체류시 대역폭의 낭비의 해결방안 그리고 이동성 예측 실패시 패킷손실을 없앨 수 있는 방안에 대해서 제안하였다.

  • PDF

Effect of Reverse Screw Elements on the Residence Time Distribution in Twin-Screw Extruder (이륜형 압출기의 체류시간 분포에 대한 역피치 스크류의 효과)

  • Lim, J.K.;Wakamiya, S.;Noguchi, A.;Lee, C.H.
    • Korean Journal of Food Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.208-212
    • /
    • 1985
  • The residence time distributions were measured experimentally to determine the effect of reverse screw elements at various screw configurations in twin screw extruder. A simple model was used to estimate the number of filled C-chamber on the forwarding screw. The inclusion of reverse-screw elements resulted in the increase of median residence time and the broadening of color distribution. True residence time was affected by using the reverse screw elements just before the die. The number of filled C-chamber was decreased with the increase of screw revolution speed at the same screw configuration.

  • PDF

Performance of Rotating Biological Contactor under Various Hydraulic Residence Time on thle Removal of Total Ammonia Nitrogen and COD in a Simnulated Water Recirculating System (모의 순환여과식 실험장치에서 회전원판반응기 (RBC)에 의한 순환수처리)

  • SUH Kuen-Hack;KIM Byong-Jin;LIM Sung-Il;CHO Jin-Koo;KIM Yong-Ha;OH Chang-Sup
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.32 no.2
    • /
    • pp.180-185
    • /
    • 1999
  • Rotating Biological Contactor (RBC) was tested for the treatment of artificial rearing water in n simulated aquaculture system. Performance of RBC on the removal of TAN and COD was evaluated by controlling hydraulic residence time (HRT). As HRT of RBC was increased, TAN removal rate ana removal efficiency of RBC and TAN concentration of rearing water were increased, but COD removal rate was decreased. Total alkalinity consumption rate was increased by increasing HRT of RBC. Ratio between total alkalinity consumption rate and TAN removal rate was 7.73. HRT for maintaining lowest TAN and COD concentration of artificial rearing water was 14,6 minutes and at that condition TAN and COD concentration of the water was 1.28 and $5.59 g/m^3$, respectively.

  • PDF

The Optimum Design of Suspended Growth Systems (부유성 미생물을 이용한 생물처리법의 최적 설계)

  • Lee, Jeoung-Su
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.6
    • /
    • pp.1011-1019
    • /
    • 2000
  • The purpose of this study is to examine the basis of design condition of existing treatment processes, namely, Extended Aeration Process, Conventional Activated Process, High Rate Aeration Process and Modified Aeration Process, by clarifying the correlations of influent wastewater concentration, hydraulic retention time, food-to-microorganism ratio and sedimentation of sludge, as well as to ascertain the feasibility of design, regardless of the existing design condition. In particular, this study made a priority investigation of hydraulic retention time and sludge sedimentation, because sludge sedimentation is the main factor$^{1)}$ which determines the operating conditions of existing treatment processes. Therefore, it is generally known that in case exceeds the sphere of design presented for each treatment, sludge bulking may occur. The results of Lesperance's test$^{1)}$, which formed the basis of design, showed the sphere of loading without security of sludge sedimentation, as in Fig. 1. The reason for sludge bulking in a certain condition, as above, is due to failure in application of optimum loading corresponding to each retention time by employing a few operating condition, which proved to be consecutively workable after years of trials and failures by Lesperance, for test conditions. However, the result of this test showed that in case of proper maintenance of loading. sludge sedimentation can be ensured under 120 SVI. Therefore, this study suggested hydraulic retention time and its corresponding optimum loading, and identified the hydraulic retention time as a determinant of sludge sedimentation. And. on the basis of these findings, this study suggested the feasiblity of UHR(Ultra High Rate), a new operating process, exceeding several times the applicable loading value of High Rate Aeration Process under one hour retention time which has not yet applied to the existing treatment processes.

  • PDF

Study on the Improvement of Nitrate Removal Efficiency in Multi-Step Electro-chemical Process (전기화학적공정에서 질산성질소 제거효율 향상에 관한 연구)

  • Sim, Joo-Hyun;Kang, Se-Han;Seo, Hyung-Joon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.2
    • /
    • pp.155-160
    • /
    • 2008
  • In this study, the nitrate removal efficiency was examined under a variety of operating conditions, such as different doses of the reducing agent, different electrode types, different HRTs(hydraulic retention times), and different current densities, using the multistep electrochemical process. The nitrate removal efficiency increased and the input energy decreased when the reducing agent was used, and almost no difference was found between the electrode types in terms of their nitrate removal efficiency and current efficiency. So that the Zn reducing agent could be recovered, though, the B-type electrode was chosen(step 1: Pt-Zn; step 2: Pt-Zn; step 3: Pt-Zn; step 4: Pt-Zn). HRT experiments were carried out on constant electric current density unrelated HRTs and various electric current density related HRTs: the constant amount of electric current per unit volume. As a result, HRT and the electric current density caused concentration polarization and the lack of an applied current. That is to say,the lower the HRT, the greater the decrease in concentration polarization and in the amount of applied current per unit volume. Therefore, optimal conditions were found through the experiments that were conducted on HRT and electric current density. When a spacer was installed in the process, the nitrate removal efficiency and energy efficiency increased even more because the diffusion likewise increased.