• Title/Summary/Keyword: 체결부

Search Result 380, Processing Time 0.174 seconds

Stress Analysis of the Blade Joint for a Small Wind Turbine (소형풍력터빈 블레이드 체결부의 응력해석)

  • Kim, Deok-Su;Jung, Won-Young;Jung, Jin-Tai
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.1
    • /
    • pp.117-124
    • /
    • 2012
  • In this paper, an analysis of the joint that transmits power from the blades to the generator is performed using the FEM (finite element method). The mode shapes and natural frequencies were extracted using experimental modal analysis in order to establish the FEM model. Then, the model was verified by comparing the mode shapes and natural frequencies to those obtained from the ANSYS modal analysis. Dynamic stress analysis was performed at the rated and limited wind speeds considering the wind load and gravity.

접촉요소(Contact Element)를 적용한 나사체결부(Thread joint)의 구조해석

  • 구송회;이방업;조원만;이환규
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.15-24
    • /
    • 1996
  • 로켓모타의 연소관은 구조적인 편의성 및 경량화를 위하여 도옴-실린더부와 실린더-노즐부에 나사체결방법을 많이 적용하고 있는데, 나사의 골부위에 집중응력이 발생하여 인장강도를 넘는 응력이 발생하는 경우가 있다. 본 연구에서는 나사의 골부위의 응력수준을 좀 더 정확히 예측하기 위하여 나사체결시 작용하는 조립 토오크에 의한 초기하중을 고려한 구조해석을 수행하였으며, 나사부위에 발생하는 응력이 항복강도를 초과하므로 정확한 해석을 위하여 탄소성해석을 수행하였다. 조립 토오크에 의한 초기하중은 나사체결 멈춤부에 음(-)의 접촉 간극을 부여하여 모델링하였으며, 조립 토오크의 크기는 나사체결 근접부에서 변형률을 측정하여 모사하였다. 해석결과 초기하중을 고려하여 구조해석을 수행하면 최대예상 작동압력에서 초기하중의 영향은 거의 나타나지 않았으며, 마찰계수를 감소시키면 최대응력이 감소하여 구조적 안전성이 증가할 것으로 판단된다.

  • PDF

Hygrothermal Effect on the Strength of Carbon/Epoxy Composite Single-Lap Bonded Joints (고온습도 및 저온 환경이 복합재 접착 체결부 강도에 미치는 영향 연구)

  • Song, Min-Gyu;Kweon, Jin-Hwe;Choi, Jin-Ho;Kim, Hyo-Jin;Song, Min-Hwan;Shin, Sang-Joon;Byun, Jai-Hyun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.2
    • /
    • pp.119-128
    • /
    • 2010
  • The hygrothermal effect on the strength of composite single-lap bonded joints were investigated. The specimens were manufactured in four different manufacturing methods and tested in three different environmental conditions. An interesting result is that the strengths of the joints in the elevated temperature and wet (ETW) conditions were found to be 11 ~ 23% higher than those in the room temperature and dry (RTD) environment. In contrast, the strengths of the joints in the cold temperature and dry (CTD) condition decrease by 8 ~ 21% compared to those in the RTD environment except for cobonded joint. The difference in the strength by testing environments is mainly attributed to the change of the material properties of adhesive by temperature and moisture.

A Study on Strength Prediction of Mechanical Joint of Composite under Bending Load (굽힘 하중을 받는 복합재 기계적 체결부의 강도예측에 관한 연구)

  • Baek, Seol;Kang, Kyung-Tak;Lee, Jina;Chun, Heoung-Jae
    • Composites Research
    • /
    • v.27 no.6
    • /
    • pp.213-218
    • /
    • 2014
  • This paper predicted the strength of mechanical joint of composites under bending load by means of the characteristic curve method. The method has been employed only for tensile and compression load conditions, but in this study, this method was extended to the bending load condition. For the finite element analysis (FEA), the nonlinear analysis was conducted considering the contact and friction effects between composite material and pin. The failure strength and mode on characteristic curve were evaluate with Tsai-Wu failure theory. To validate the results of FEA, the experiments were conducted to find out the failure load by applying bending moment on the composite specimens. The results showed reasonable agreements with theoretical results. These results lead to a conclusion that the characteristic curve method can be applied to predict the bending strength of mechanical joint of composites.

Strength of Stainless Steel Pin-reinforced Composite Single-lap Joints (금속 핀으로 보강된 복합재 단일겹침 체결부의 강도 연구)

  • Lee, Byeong-Hee;Park, Yong-Bin;Kweon, Jin-Hwe;Choi, Jin-Ho;Choi, Ik-Hyeon;Chang, Sung-Tae
    • Composites Research
    • /
    • v.25 no.3
    • /
    • pp.65-69
    • /
    • 2012
  • The main objective of this study is to investigate the effect of metal z-pinning on the failure behavior of cocured composite single-lap joints. Three different pin diameters (0.3, 0.5, and 0.7 mm) and three pin areal densities (0.5, 2.0, and 4.0%) were examined. The specimens were fabricated by T700-12K-31E#2510 unidirectional prepreg from Toray. Stainless steel pins were used for z-pinning. Test results showed that except one case with extremely low pin density of 0.5%, all other z-pinned joints exhibited lower initial crack stresses than those of the unpinned joint. However the ultimate strength of the z-pinned joint increased up to 45% at most. Furthermore, even after the complete failure of the joint, the z-pins sustained the carried load to a certain degree experiencing large deformation and provided the stable fracture behavior for the composite joint.

Failure Behavior of Pin-jointed Composites under Hygrothermal Environments (열습환경을 고려한 핀 체결부 복합재 파괴거동)

  • Kim, Changyu;Hwang, Youngeun;Yoon, Sungho
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.2
    • /
    • pp.31-38
    • /
    • 2013
  • This research analyzed the acoustic emission signals collected from the pin loading tests and investigated the effect of hygrothermal exposure on the fracture behavior of the pin-jointed carbon fiber/epoxy composites. The composite specimens include: the Base specimen that has not been exposed to any environments, the RT specimen that has been immersed in room temperature water, and the HT specimen that has been immersed in high temperature water. According to the pin loading test, the RT and the HT specimens showed 2.2% and 13% decreases in the bearing strength compared to the Base specimen, respectively. The analysis of the acoustic emission signals showed different fracture acceleration points for three types of the specimens. Furthermore, for the RT and the HT specimens, the event from the matrix crack signals in the composites decreased. This shows the effect of the hygrothermal conditions on the acoustic emission signals. Additionally, upon investigating the fracture behaviors of the pin-jointed composites, the exposing specimens to hygrothermal environments decreases the interfacial characteristics of the composites.

Progressive Filure Analysis of Composite Double Bolted Joints using Gradual Degradation Model (점진적 강성 저하 모델을 이용한 복합재 이중 볼트 체결부의 점진적 파손 해석 연구)

  • Kim, Pyunghwa;Kim, Sungmin;Doh, Sungchul;Yoon, Donghyun;Park, Jungsun
    • Journal of Aerospace System Engineering
    • /
    • v.13 no.6
    • /
    • pp.26-35
    • /
    • 2019
  • In this paper, progressive failure analysis is performed on composite joints widely used in various industries such as the aerospace industry. The analysis was conducted on single bolted joints to confirm its reliability and in succession on double-bolted composite joints as well to study the characteristics of progressive failure. Hashin failure criteria and EGDM (energy based gradual degradation model) were used for the analysis. Failure variables are defined by four failure modes, respectively. According to the variables, stiffness degradation has been calculated. As a result of comparing the test and analysis results of single-bolted joints, the error was below 5% and it showed that the analytical results are rather credible. Also, the parametric analysis consequences were obtained conducting the process-progressive failure analysis on the double-bolted composite joints considering edge-distance ratio (e/d ratio) and bolt spacing.

A Study on the Change of Load Carrying Capacity of High-tension Bolt Joints by Critical Sections (단면결손에 따른 고장력볼트 체결부의 내하력 변화에 관한 연구)

  • Park, Jeong-Ung;Yang, Seung-Hyun;Jang, Seok-In
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.9
    • /
    • pp.2402-2408
    • /
    • 2009
  • This study conducted a static tensile test in order to prevent the lowering of load carrying capacity caused by critical sections made by over bolt holes in the base plate and the cover plate of steel member joints using high-tension bolts. The change of the load carrying capacity of joints was examined by comparison of the maximum load on joint fracture obtained from the tensile test with critical section rate and design strength. According to the results, the rate of decrease in strength was higher when the critical section rate was high, and in particular, decrease in strength was affected much more by critical sections in the base plate than by those in the cover plate. In high-tension bolt joints using over bolt holes for the base plate and the cover plate, load carrying performance was somewhat lower than that in joints using standard bolt holes, but the maximum tensile strength on facture was over 15% higher than design fracture strength. According to the results of this study, the use of over bolt holes in high-tension bolt joints had an insignificant effect on the lowering of load carrying capacity, so the allowance of over bolt holes in the joints of steel members is expected to enhance to the economy and efficiency of the works.

A New Method to Determine the Characteristic Lengths for the Failure Analysis of Composite Joint (복합재 체결부의 파손해석을 위한 새로운 특성길이 결정 방법)

  • 안현수;권진희;최진호
    • Composites Research
    • /
    • v.16 no.4
    • /
    • pp.10-21
    • /
    • 2003
  • Proposed is a new method to determine the characteristic lengths for the failure analysis of composite joint without experiments. New method uses the result that the stress distribution in the characteristic length specimens is linearly proportional to the applied load. The compressive characteristic lengths calculated by the present method are exactly same as the lengths obtained by the conventional method based on experiment. The new tensile characteristic length is defined using the strength of the notched laminate, while previous methods use the strength of the sound laminate. That change allows calculating the tensile characteristic length numerically without experiment like the compressive characteristic length. Finite element analyses are conducted by MSC/NASTRAN. The interface between the fastener and laminate is modeled by the contact surface element. The finite element results based on the new characteristic lengths show the excellent agreement with experimental results for the Graphite/Epoxy composite .joints.

Strength Analysis of Composite Double-lap Bolted Joints by Progressive Failure Theory Based on Damage Variables (손상변수기반 점진적 파손이론을 이용한 복합재 이중 겹침 볼트 체결부의 강도 해석)

  • Kim, Sang-Kuk;Kweon, Jin-Hwe
    • Composites Research
    • /
    • v.26 no.2
    • /
    • pp.91-98
    • /
    • 2013
  • A three-dimensional finite analysis method was proposed to predict the failure of composite double-lap bolted joints, which is based on the stiffness degradation method using damage variables and Hashin's three-dimensional failure criteria. Ladeveze's theory using damage variables to consider the matrix/shear damage was combined with stiffness degradation in fiber direction. Four different failure modes were considered including matrix compression/shear, matrix tension/shear, fiber compression, and tension failures. The friction between bolt and composite and the clamping force were considered using a commercial finite element software ABAQUS. The damage model was incorporated using the user-defined subroutine of the software. The predicted result was verified with the existing test result for bearing tension double shear and showed the deviation ranging 7~16% from test results.