Humidity Change Rate Analysis for Various Waterproofing Method in Underground Structures During Winter Season (지하 구조물 동절기 온도조건에서의 방수공법별 습도 변화량 분석)

  • An, Ki-Won;Lee, Yeon-Sil;Lee, Jung-Hoon;Song, Je-Young;Oh, Sang-Keun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.1
    • /
    • pp.118-125
    • /
    • 2016
  • This paper proposes the appropriate waterproofing methods for underground structures after applying different types of waterproofing materials on the concrete test specimens and selecting the best results out of humidity testing in winter conditions. Results of the testing showed that the underground structures absolutely require relevant waterproofing application based on the environmental conditions; when applied with interior waterproofing, the results showed that the concrete maintained high level of humidity and reinforcing steel within the concrete layer corroded. However, when applied with exterior waterproofing, it was shown that the waterproofing layer prevent direct contact with water and concrete, thereby protecting the concrete structure and improving overall durability. It follows that during underground structure construction, exterior waterproofing methods are have shown by an effective method for improving the durability as well as providing a comfortable interior environment for users.

Effect of steel fibers on surface electric resistivity of steel fiber reinforced concrete for shield segment (강섬유보강 콘크리트 세그먼트의 강섬유가 표면전기저항에 미치는 영향)

  • Moon, Do-Young;Lee, Gyu-Phil;Chang, Soo-Ho;Bae, Gyu-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.13 no.6
    • /
    • pp.557-569
    • /
    • 2011
  • Steel Fiber Reinforced Concrete (SFRC) is widely used for tunnel structures such as shotcrete and segments. Corrosion of steel fibers and steel reinforcements may affect on the long-term durability of the concrete structures with steel fibers and reinforcement. Therefore, a study on the feasible method to evaluate corrosion possibility and permeability of the concrete structures is required. This experimental study examines the effect of steel fibers and internal reinforcement on the surface resistivity. Steel fiber mix ratio and corrosion of internal reinforcement were considered as variables. In the results, steel fibers significantly reduce the surface resistivity due to those conductive characteristic. In the case of 3% mix ratio, it was difficult to evaluate rate and permeability of corrosion due to the great reduction of resistivity by mixing of steel fibers.

Probabilistic Estimation of Service Life of Box Culvert for Power Transmission Considering Carbonation and Crack Effect (탄산화와 균열을 고려한 전력구 콘크리트 구조물의 확률론적 수명 예측)

  • Woo, Sang-Kyun;Lee, Yun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.6
    • /
    • pp.30-40
    • /
    • 2014
  • The demand of underground structure such as box culvert for electric power transmission is increasing more and more, and the service life extension of these structures is very important. Recent observations in field and experimental evidences show that even steel in concrete can be corroded by carbonation reaction of cover concrete. Carbonation-induced corrosion in concrete may often occur in a high carbon dioxide environment. In this study, the risk of carbonation of box culverts in our nation was evaluated by measuring the carbonation rate and concrete cover depth in field. Then, the service life due to carbonation at the cover depth was calculated by in situ information and the Monte Carlo simulation in a probabilistic way. Additionally, the accelerated carbonation test for the cracked beam specimen was executed and the crack effect owing to the carbonation process on the service life of box culvert was numerically investigated via Monte Carlo simulation based on the experimental results.

An Introduction to the Shrinkage Strip for the Crack Control in the Underground Parking Structure (지하주차장의 수축대 시공사례)

  • 김록배;김욱중;이도범;이운세
    • Magazine of the Korea Concrete Institute
    • /
    • v.14 no.2
    • /
    • pp.77-82
    • /
    • 2002
  • 일반적으로 공동주택 지하주차장과 같이 구조물이 대형화되거나 복잡할 경우 구조물의 응력취약 부위에서 균열, 누수 등의 문제가 발생할 확률이 크다. 이에 대한 대책으로 설계자들은 신축줄눈을 선호하고 있으나 신축줄눈은 시공상의 어려움과 사용 중 잦은 하자 발생이라는 문제점을 안고 있다. 이 때문에 근래에 들어 대형 건물을 한 단위로 처리하고 철근으로 보강하려는 경향이 있으나 구속도 차이에 따라 균열, 누수 등의 문제가 여전히 발생하고 있다. 이를 해결하기 위하여 수축대를 설치하여 일정 요구량의 초기 수축량을 수축대에서 흡수하고 이후 수축대 부위에 콘크리트를 메워 일체화시킴으로써 초기 수축에 의한 균열을 상당부분 방지할 수 있다.(중략)

Flexural Test on Composite Deck Slab Produced with Extruded ECC Panel (압출성형 ECC 패널을 이용하여 제작된 복합바닥슬래브의 휨 거동)

  • Cho, Chang-Geun;Han, Byung-Chan;Lee, Jong-Han;Kim, Yun-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.5
    • /
    • pp.695-702
    • /
    • 2010
  • This paper presents a reinforced concrete composite deck slab system newly developed using a high ductile ECC extrusion panel. In the construction practice, the cracking of reinforced concrete slab often becomes a problem especially in parking garages, underground structures, and buildings. The ECC panel manufactured by extrusion process as a precast product has not only a high-quality in control of cracking but also a merit in applying the construction of concrete slab because the use of ECC panel can realize a formless or half-precast construction with cast-in-place concrete. In the newly developed deck slab system, the ECC extrusion panel is located in the bottom of slab with the thickness of 10 mm, reinforcements are assembled and located on the ECC panel, and finally the topping concrete is placed in the field. In order to evaluate the newly developed slab system, experimental works by four point bending test are conducted to compare with the conventional reinforced concrete slab system. From experiment, the developed deck slab system using a ECC panel gives many improved performances both in control of bending cracking and in load-carrying capacities of slabs.

An Experimental Study on Flexural Behavior in Framed Structure of P.S.T Method (P.S.T 공법 라멘 구조물의 휨 거동 특성에 관한 실험적 연구)

  • Cui, Jie;Yoon, Jong Nam;Eum, Ki Young;Hong, Sung Nam;Park, Sun Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.2
    • /
    • pp.144-152
    • /
    • 2011
  • The existing underground trenchless methods use reinforcing rod in steel tube to obtain structural stiffness. However, there are some problems such as inconvenience of work and expensive material fee which are resulted from limited working space and reinforcing work. To resolve these problems, a new trenchless method, namely P.S.T method (Prestressed Segment Tunnel Method), is developed which uses joint to connect the steel segment and form erection structure in underground construction. Further, installing strands for prestressing. In order to evaluate the flexural capacity of the P.S.T method structure, experiment was conducted. The parameters considered in the experiment are the span-to-depth ratio, diameter of steel tube at corner, prestressing force and welding of joint. Altogether examining the flexural behavior, the effect of deflection in structure according to different parameters has also been analysised.

Numerical Study of Structural Behavior of Underground Silo Structures for Low-and-Intermediate-level Radioactive Waste Disposal Facility (중저준위 방폐물 처분 사일로 구조물의 구조거동 수치해석 연구)

  • Kim, Sun-Hoon;Kim, Kwang-Jin
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.35 no.3
    • /
    • pp.183-190
    • /
    • 2022
  • The construction of an underground silo structure was the first stage of erecting the Gyeongju low-and-intermediate-level radioactive waste disposal facility. The facility, completed in 2014, has a scale of 100 000 drums and is currently in operation. The underground silo structure, 25 and 50 m in diameter and height, respectively, consists of cylindrical (for storing waste packages) and dome parts. The dome is divided into lower (connected to the operation tunnel) and upper parts. The wall of the underground silo structure is an approximately 1-m-thick reinforced concrete liner. In this study, finite element analysis was performed for each phase of the construction sequence and operation of the underground silo structure. Two-dimensional axial symmetric finite element analysis was implemented using the SMAP-3D program. Three-dimensional finite element analysis was also performed to examine the reliability of the two-dimensional axial symmetric finite element model. The structural behavior of the underground silo structure was predicted, and its structural safety was examined.

The Study of detailng for concrete reinforcement and Seismic Analysis Method for Underground Reinforced Concrete Box Structures (지하 철근 콘크리트 박스 구조물의 내진해석방법 및 철근 배근 상세에 관한 연구)

  • Lee, Myoung-Soo;Han, Sang-Chel
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.1215-1222
    • /
    • 2005
  • The object of this thesis is an study on detailing for concrete reinforcement and analytical study for seismic behavior of underground reinforced concrete box structures using the established seismic analytical method. Using the established seismic analytical method that has been presented in various documents seismic behavior of buried reinforce concrete box structures is compared. From the comparsion, it is shown that feasibility and detailing detailng for concrete reinforcement and seismic method for seismic analysis of buried reinforced concrete box structures.

  • PDF

Analysis of Underground RC Structures considering Elastoplastic Interface Element (탄소성 경계면 요소를 고려한 철근콘크리트 지하 구조물의 해석)

  • 남상혁;송하원;변근주
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.471-476
    • /
    • 2001
  • Even though structural performance evaluation techniques for reinforced concrete structures have been improved, there are still many problems in the evaluation of structural performance for underground structures which interacts with surrounding soils. Since experimental evaluation of underground RC structures considering the interaction with the surrounding soil medium is quite difficult to be simulated, the evaluation for underground RC structures using an analytical method can be applied very usefully, For underground structures interacted with surrounding soils, it is important to consider path-dependent RC constitutive model, soil constitutive model, and interface model between structure and soil, simultaneously. In this paper, an elastoplastic interface model which consider thickness was proposed and importance of interface model is discussed. The effects of stiffness of structures to entire underground RC system are investigated through numerical experiment for underground RC structure for different reinforcement ratios and thickness of interfaces.

  • PDF

Seismic Analysis of Underground RC Structures considering Interface between Structure and Soil (경계면 요소를 고려한 지하 철근콘크리트 구조물의 지진해석)

  • 남상혁;변근주;송하원;박성민
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.87-92
    • /
    • 2000
  • The real situation of an underground reinforced concrete(RC) structure with the surrounding soil medium subjected to seismic load is quite difficult to be simulated through an expensive work and, even if it is possible to arrange such an experiment, it will be too expensive. So development of analytical method can be applied usefully to seismic design and seismic retrofit through an analysis of seismic behavior and seismic performance evaluation. A path-dependent constitutive model for soil that can estimate the response of soil layer is indispensible for dealing with kinematic interaction of RC/soil entire system under seismic loads. And interface model which deals with the dynamic interaction of RC/soil entire system is also necessary. In this study, finite element analysis program that can consider path-dependent behavior of RC and soil, and interfacial behavior between RC and soil is developed for rational seismic analysis of RC/soil entire system. Using this program, nonlinear behavior of interface between RC and soil is analyzed, and the effect of interfacial behavior to entire system is investigated.

  • PDF