• Title/Summary/Keyword: 철근간격

Search Result 196, Processing Time 0.02 seconds

Flexural Strength of Reinforced Concrete Beams Containing Recycled Coarse Aggregate (순환굵은골재를 사용한 철근콘크리트 보의 휨강도)

  • Yang, In-Hwan;An, Seul-Ki;Hwang, Chul-Sung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.1
    • /
    • pp.30-39
    • /
    • 2017
  • This paper concerns flexural strength of reinforced concrete beams containing recycled coarse aggregate (RCA) with compressive strength ranging from 31 to 38 MPa. The experimental parameters were replacement ratio of RCA and rebar ratio. Replacement ratio of RCA was 0, 30, 50 and 100%, and rebar ratio was 0.50, 0.79 and 1.14%. The RCA concrete beams were tested by using four-point bending test, and experimental results were discussed regarding crack and failure patterns, load-deflection relationship. Crack pattern of concrete beams with RCA was similar to that of concrete beams with natural coarse aggregate (NCA) but overall crack spacing of concrete beams with RCA was smaller than that of concrete beams with NCA. The crack width of RCA and NCA concrete beams was similar to each other. In addition, the test results of flexural strength were compared to the design code predictions. The design code predictions for flexural strength underestimated the experimental results. Therefore, the design code predictions for flexural strength of RCA concrete beams would offer conservative design.

Structure Behavior Evaluation of Beams composited with Steel and Reinforced Concrete (철근콘크리트와 강을 합성한 복합 단면보의 구조거동평가)

  • Kim, In Seok;Kim, Hak Soo
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.5
    • /
    • pp.665-673
    • /
    • 2008
  • The composite structures of steel and reinforced concrete, which have been widely used in large-scale concrete structures, werestudied to investigate the cause of unexpected cracks and to verify the composite actions between the two materials. Vertical stiffeners between flanges, studs and dowel bars, stirrups, and concrete strength were chosen as experimental variables in afour-point loading test. The results showed that the vertical stiffener prevented not only the local web buckling, but also bond failures between steel and concrete. It increased the flexural resistance (fracture loads) due to the composite action of two materials, compared withthose of any experimental variable. However, the composite behavior of steel reinforced concrete beam was not affected seriously by additional studs, dowel bars, stirrups, and concrete strength.

A Study on the Improvement of Durability Design of Underground RC Structures (RC 지하구조물의 내구성설계 개선에 관한 연구)

  • Im, Jung-Soon;Bahng, Yun-Suk
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.7 no.4
    • /
    • pp.13-18
    • /
    • 2007
  • The research was performed to review the design factors which affect the durability of structures. For the study, domestic and foreign literature review were performed on various design criteria. Based on Korean standard specifications, the results showed that the durability of structure as the diameter of reinforcing steel bar becomes smaller and the distance between reinforcing bar is closer than the normal gap. The results were also presented that the minimum required bar cover is 6.6cm to obtain the durability index value. In addition, the maximum limited bar cover was 12cm considering the durability index and the change of increasing value of durability index. In case that there is no specified regulation for the bar cover thickness change, the durability life by neutralization is proportional to the thickness of bar cover.

Seismic Performance of RC Columns Confined by Outside Lateral Reinforcement (외측 횡보강재로 구속된 철근콘크리트 기둥의 내진성능)

  • Lee, Do Hyung;Oh, Jangkyun;Yu, Wan Dong;Choi, Eunsoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.3A
    • /
    • pp.189-196
    • /
    • 2012
  • In this paper, reinforced concrete columns test has been conducted under repeated lateral load reversals. The test columns have been reinforced with outside lateral confinement members in addition to transverse reinforcements. For this purpose, a strainless steel and a GFRP have been employed for the lateral confinement members. Primary parameters are types, thickness and spacing of the lateral confinement members. Experimental results reveal that columns reinforced with lateral confinement members exhibit improved ductility and energy dissipation capacity in comparison with those unreinforced. It is thus concluded that the present approach can be of a useful scheme for the seismic retrofitting of reinforced concrete columns.

A Theoretical and Experimental Investigation on the Flexural Behavior of Reinforced Concrete Members Containing Steel Fibers (강섬유를 혼입한 철근콘크리트부재의 휨거동에 관한 이론 및 실험연구)

  • 오병한
    • Magazine of the Korea Concrete Institute
    • /
    • v.3 no.3
    • /
    • pp.129-139
    • /
    • 1991
  • The mechanical hehavior of relIlforced concrete beams with steel fibers is investigated 111 the present study. An expenmental program was set up and several series of rem forced concrete beams have been tested, including two senes of singly-reinforced concrete beams and one senes of doubly-reinforced concrete beams. It was found from th, :se measurements that the crack widths lIlcrease almost llIlearly With the lIlcrease of steel stress and that the crack Widths at the same loadlJ1g stages are greatly reduced as the contents of steel fibers increase. The present study also IJ1chcates that the ductiiIty and the ultJmate resistance are remarkably enhanced due to the addition of steel fibers. A theoretical mex1e1 for the flexural analysis of fiber-reinforced concrete beam which takes into account the effects of fibers JS also proposed.

Electromagnetic Modeling of Shielding Effectiveness of Reinforced Concrete Walls (철근 콘크리트에 의한 전자기파 차폐 효과 모델링)

  • Hyun, Se-Young;Lee, Kyung-Won;Kim, Min-Suk;Yook, Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.3
    • /
    • pp.384-391
    • /
    • 2012
  • In this paper, reinforced concrete structures are modeled and analyzed. Reinforced concrete has been an essential element in the construction and one that is provided for shielding effectiveness at particular frequencies by rebar placed as a set up in the form of a grid. Using commercial 3-dimensional electromagnetic(3D EM) tool to analyze the reinforced concrete structure, the procedure of analysis for reinforced concrete is computed by dividing concrete, rebar and entire reinforced concrete. The spacing of rebar is bigger, transmission coefficient is higher and the diameter of rebar is bigger, transmission coefficient is lower. Also, in case of two layers is analyzed by gap of layers. Using single layer rebar that thickness of rebar given by 10, 20 and 30 mm have transmission coefficient of -1.89, -2.73 and -4.76 dB/10 cm at 500 MHz. Also, two layers rebar obtain -1.89, -2.73 and -4.76 dB/10 cm for same conditions.

Behavior of Reinforced Concrete Slabs Connected with Hinge Joints of Remodelling Buildings (리모델링 건물의 활절점에 의하여 연결된 철근콘크리트 바닥판의 거동 평가)

  • Sim Kyu-Kwan;Kim Sang-Sik;Lee Jung-Yoon;Choi kwang-Ho;Im Juhyeuk
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.5 s.89
    • /
    • pp.761-768
    • /
    • 2005
  • Lately outmoded and functionally obsolete buildings constructed in 1960s and 1970s are often remodelled and restored. Even though there are not serious structural defects in the existing buildings, many old buildings have been reconstructed to improve residence quality or to extend residence area of the buildings. The experimental or theoretical research on plane expansion of RC apartments is quite scare. In this research, 12 specimens and 19 RC slabs connected by hinged joints were tested. The new slab was connected to the existing slab by hinge joints injecting dowel bars between two slabs. Main parameters of the slabs are types of the dowel bars (D13 and D19), spacing of the dowel bars (150mm, 300mm, and 450mm), and the locations of the steel bars in the existing slabs. The test results indicated that the shear strength of the RC test slabs having various types of dowel bars was about twice that calculated by the ACI 318-02 code. All slabs failed in concrete spatting and the dowel steel bars did not reach their yield strengths.

Evaluation of Ductility in Reinforced Concrete Members Using Material Models in Eurocode2 (유로코드 2 재료모형을 사용한 철근콘크리트 부재의 연성도 평가)

  • Choi, Seung Won
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.2
    • /
    • pp.287-297
    • /
    • 2015
  • In concrete structural design provisons, there is a minimum allowable strain of steel to ensure a ductility of RC members and a c/d is limited for the same purpose in EC2. In general, a ductility capacity of RC members is evaluated by a displacement ductility which is a ratio of ultimate displacement to yield displacement, and it is necessary to calculate accurately a yield displacement and an ultimate displacement to evaluate a displacement ductility. But a displacement in members is affected by various member characteristics, so it is hard to calculate a displacement exactly. In this study, a displacement ductility is calculated by calculating a yield displacement and an ultimate displacement through a moment-curvature relationship. The main variables examined are concrete strength, yield strength, steel ratio, spacing of confinement, axial force ratio and concrete ultimate strain. As results, as a concrete strength is increased, a ductility displacement is increased. But as yield strength, steel ratio, spacing of confinement and axial force ratio are increased, a displacement ductility is decreased. And a displacement ductility is necessary to calculate a response modification factor (R) of columns for seismic design, so it is appeared that it is important to calculate a displacement ductility more accurately.

Structural Behavior of RC Beams Strengthened with Steel Plates (강판 휨보강된 철근콘크리트보의 구조적 거동)

  • 오병환;조재열;강동옥
    • Magazine of the Korea Concrete Institute
    • /
    • v.9 no.5
    • /
    • pp.233-244
    • /
    • 1997
  • 구조적으로 손상을 입은 구조물들에 대한 보강방법으로 강판, 카본쉬트, 아라미드섬유쉬트 등을 이용한 접착공법이 최근 들어 많이 사용되고 있으며 그 중 가장 널리 Tm이는 방법은 강판접착공법이다. 강판접착공법에 대해서는 많은 연구가 진행되어 오고 있으나, 보의 구조적 거동에 영향을 미치는 다양한 인자들의 영향이나 강성, 파괴양상등에 미치는 영향들에 대해서는 체계적인 평가가 이루어지지 않은 실정이며 특히 강판접착공법에서 파괴에 큰 영향을 미치는 박리하중에 대한 연구는 미흡한 실정이다. 따라서 본 연구에서는 일련의 철근콘크리트보부재를 대상으로 하여 주요실험변수로 선행하중의 크기, 강판의길이, 강판의 두께, 앵커볼트의 간격과 유무, 강판의 층수, 측면보강높이를 실험변수로 하여, 휨인장에 대해 강판잡착공법을 적용하여 포괄적인 실험을 수행하였다. 3등분점하중법의 실험결과를 이용하여 처짐, 인장 및 압축 철근의 변형도, 콘크리트와 강판의 변형도를 분석하였고, 이를 토대로 파괴양상과 파괴하중을 분석하였다.

An Experimental study on Shear Resisting Effect of Reinforced Concrete Beams Filling-up Carbon Fiber Rod Plastic (CFRP-Rod로 전단 보강된 철근콘크리트 보의 전단거동에 관한 실험적 연구)

  • Kim, Young-Sik;Park, Sung-Moo
    • Proceeding of KASS Symposium
    • /
    • 2005.05a
    • /
    • pp.183-190
    • /
    • 2005
  • The purpose of this study is to investigate experimentally the shear resisting behavior of the reinforced concrete beams strengthened with reinforcement materials(CFRP). Five specimens were manufactured and tested under, static monotonic loading. The main variables In the test were a space and volume of reinforcement. The test result indicated that the method of CFRP increase significantly the shear strength of a reinforced concrete beam

  • PDF