• 제목/요약/키워드: 철골모멘트 골조

검색결과 116건 처리시간 0.027초

내진 보강된 철골모멘트골조의 취약성 등고선을 통한 성능평가 (Performance Evaluation of Steel Moment Resisting Frames with Seismic Retrofit Using Fragility Contour Method)

  • 김수동;이기학;정성훈;김도현
    • 한국지진공학회논문집
    • /
    • 제17권1호
    • /
    • pp.33-41
    • /
    • 2013
  • Due to a high level of system ductility, steel moment resisting frames have been widely used for lateral force resisting structural systems in high seismic zones. Earthquake field investigations after Northridge earthquake in 1994 and Kobe earthquake in 1995 have reported that many steel moment resisting frames designed before 1990's had suffered significant damages and structural collapse. In this research, seismic performance assessment of steel moment resisting frames designed in accordance with the previous seismic provisions before 1990's was performed. Buckling-restrained braces and shear walls are considered for seismic retrofit of the reference buildings. Increasing stiffness and strength of the buildings using buckling-restrained braces and shear walls are considered as options to rehabilitate the damaged buildings. Probabilistic seismic performance assessment using fragility analysis results is used for the criteria for determining an appropriate seismic retrofit strategy. The fragility contour method can be used to provide an intial guideline to structural engineers when various structural retrofit options for the damaged buildings are available.

세장한 가새가 사용된 철골모멘트골조 공장시설물의 내진 성능평가 (Seismic Performance Evaluation of Steel Moment Frame Factory Building with Slender Braces)

  • 김동연;조재철;황선우;김태진;김종호
    • 한국지진공학회논문집
    • /
    • 제22권1호
    • /
    • pp.33-43
    • /
    • 2018
  • 'Seismic Performance Evaluation Method for Existing Buildings (2013)' developed in accordance with the overseas guidelines ASCE 41 - 06 is the most widely used procedure among domestic seismic performance evaluation guidelines in Korea. However, unlike ASCE 41 - 06, it stipulates that the final performance should be derived as the gravity load distribution ratio of the lateral force resistance system in the guideline. Therefore, in the case of a dual steel structure system with slender braces, where the internal moment frame is mostly responsible for the gravity load, the evaluation of slender braces based on gravity load distribution ratio is difficult to be achieved. In this research, we propose an objective evaluation process for such system by evaluating seismic performance for large-scale factory facilities as an example.

접합부 회전성능에 따른 중간 철골 모멘트 골조의 내진 성능 평가 - II 원인 평가 및 대안 (Seismic Performance Evaluation According to Rotation Capacity of Connections for Intermediate Steel Moment Frames - II. Cause Evaluation and Alternative)

  • 문기훈;한상환;하성진
    • 한국지진공학회논문집
    • /
    • 제18권2호
    • /
    • pp.105-115
    • /
    • 2014
  • This paper is the sequel of a companion paper (I. Performance Evaluation) evaluating the relation between the seismic performance of steel intermediate moment frames (IMFs) and the rotation capacity of connections. The evaluation revealed that the seismic performance of IMFs having the required minimum rotation capacity suggested in the current standards did not meet the seismic performance criteria presented in FEMA 695. Therefore, thepresent study evaluates the causes of the vulnerable seismic performance for steel IMFs and proposes alternatives to satisfy the seismic performance suggested in FEMA 695. To that goal, the results of nonlinear analysis, which are the pushover analysis and the incremental dynamic analysis, are examined and evaluated. As a result, high-rise IMF systems are seen to have the lower collapse margin ratio after connection fracture than row-rise IMF systems and, the actual response isfound to compared tothedesign drift ratio acting on design load design. Finally, the minimum design load values are proposed to meet the seismic performance suggested in FEMA 695 for IMF systems having vulnerable seismic performance.

접합부 회전성능에 따른 중간 철골 모멘트 골조의 내진 성능 평가 - I 성능평가 (Seismic Performance Evaluation According to Rotation Capacity of Connections for Intermediate Steel Moment Frames - I. Performance Evaluation)

  • 문기훈;한상환;하성진
    • 한국지진공학회논문집
    • /
    • 제18권2호
    • /
    • pp.95-103
    • /
    • 2014
  • The current AISC341-10 standard specifiesa value of 0.02 radian for the minimum rotation capacity of connections for the intermediate steel moment frame system. However, despite of the advances realized in the domains of performance evaluation method and analysis method, research onthe minimum rotation capacity of the intermediate steel moment frame systemsatisfying the seismic performance has not been conducted in detail. In this study, the intermediate moment frame systemisdesigned with respect to current standards and the seismic performance in accordance with the rotational capacity of connections is evaluated using the seismic performance evaluation method presented in FEMA-P695. The minimum rotation capacity of intermediate steel moment frames required to satisfy seismic performance as well as the major design values affecting the seismic performance of moment frame areestimated. To that goal, the design parameters are selected and various target frames are designed. The analysis models of the main nonlinear elements are also developed for evaluating seismic performance. The resultsshow that the 20-story structure doesnot meet the seismic performance even if it satisfies the rotation capacity of 0.02 radian.

철골 보통모멘트골조의 내진성능 향상을 위한 강도기반 설계 절차 제안 (Proposal of Strength-Based Design Procedure for Improving the Seismic Performance of Steel Ordinary Moment Frames)

  • 김태오;한상환
    • 한국지진공학회논문집
    • /
    • 제28권1호
    • /
    • pp.11-20
    • /
    • 2024
  • The ductility of the system based on the capacity of each structural member constituting the seismic force-resisting system is a significant factor determining the structure's seismic performance. This study aims to provide a procedure to supplement the current seismic design criteria to secure the system's ductility and improve the seismic performance of the steel ordinary moment frames. For the study, a nonlinear analysis was performed on the 9- and 15-story model buildings, and the formation of collapse mechanisms and damage distribution for dynamic loads were analyzed. As a result of analyzing the nonlinear response and damage distribution of the steel ordinary moment frame, local collapse due to the concentration of structural damage was observed in the case where the influence of the higher mode was dominant. In this study, a procedure to improve the seismic performance and avoid inferior dynamic response was proposed by limiting the strength ratio of the column. The proposed procedure effectively improved the seismic performance of steel ordinary moment frames by reducing the probability of local collapse.

비선형정적해석 절차를 이용한 선형정적 연쇄붕괴 대체경로 해석방법 개발 (Development of Linear Static Alternate Path Progressive Collapse Analysis Procedure Using a Nonlinear Static Analysis Procedure)

  • 김진구;박새로미;서영일
    • 한국전산구조공학회논문집
    • /
    • 제24권5호
    • /
    • pp.569-576
    • /
    • 2011
  • 본 논문에서는 비선형정적해석 방법을 이용하여 기존의 연쇄붕괴 선형정적해석 절차에 수반되는 반복과정을 자동으로 수행하면서도 선형해석 결과와 동일한 결과를 나타내는 새로운 연쇄붕괴 해석절차를 제안하였다. 제안된 해석절차는 GSA 기준에 규정된 기존 선형정적해석법의 단점인 반복적 해석작업 및 그 과정에서 발생할 수 있는 시간과 오류의 가능성을 최소화하여 해석결과의 신뢰성을 확보가 있는 선형정적해석 절차이다. 제안된 해석절차를 검증하기 위하여 철근콘크리트 모멘트골조 및 철골 가새골조의 최하층 기둥부재를 제거한 후 기존 해석법과 제안 해석법을 적용하고 그 결과를 비교 분석하였다. 해석결과에 따르면 제안된 해석절차는 구조물의 붕괴여부의 판정 및 힌지 분포에 있어서 기존의 선형정적해석과 동일한 결과를 나타내었으며, 반복해석 과정이 불필요하므로 기존 해석법에 비하여 매우 짧은 시간에 해석을 수행할 수 있는 것으로 나타났다.

헥사그리드 고층건물구조의 예비설계를 위한 단순모델 (Simple Model for Preliminary Design of Hexagrid Tall Building Structure)

  • 이한울;김영찬
    • 한국산학기술학회논문지
    • /
    • 제18권6호
    • /
    • pp.13-20
    • /
    • 2017
  • 시대적 흐름에 따라 고층 건물은 정형적인 형태에서 벗어나 비정형적인 형태로 변화하고 있고 최근에는 외주골조에 기하학적 그리드 패턴으로 부재를 배치하고 있다. 본 연구에서는 헥사그리드구조의 부재선정을 위한 소요단면2차모멘트 산정식을 제안하였다. 헥사그리드 고층건물의 외주골조에 동일한 단면을 사용한 기존연구와는 다르게 수평 대각 부재와 모듈의 위치에 따라 부재사이즈를 변경하였다. 헥사그리드 유닛사이즈가 구조성능에 미치는 영향을 검토하기 위해 모듈의 높이를 1개층, 2개층, 4개층 높이로 한 60층 건물을 설계하여 해석하였다. 15개 건물에 대한 최대 횡변위, 철골량, 중력하중과 횡하중에 대한 외주골조의 횡력 분담비율, 부재의 조합 강도비를 비교하였다. 헥사그리드 구조의 횡력분담 능력이 다이아그리드 구조에 비해 작아서 헥사그리드 구조에서는 코어골조에 적절한 횡강성을 배분해야 한다. 휨변형 대 전단변형의 비는 4가 가장 적합하였고 부재간 접합에 따른 시공비용 및 구조적 효율성으로 판단할 때 헥사그리드 유닛이 큰 것이 유리하다고 판단된다. 건물의 최대 횡변위가 제한치의 84%~108%로 나와 헥사그리드 건물의 예비설계에 적용 가능한 것으로 보인다.

강성도 기준에 따른 IsoTruss® 그리드 고층건물의 부재선정 방법 (Member Sizing Method in IsoTruss® Grid High-rise Building Structures Based on Stiffness Criteria)

  • 김태헌;김영찬
    • 한국산학기술학회논문지
    • /
    • 제18권12호
    • /
    • pp.50-56
    • /
    • 2017
  • 고층건물에서 횡력 저항의 주된 역할을 하는 외주골조는 기둥과 보를 직교시켜 구성하는 것이 일반적이었으나 최근 다양한 그리드형태의 부재배치가 이루어지고 있다. 선행연구에서는 아이소트러스 그리드를 고층건물의 외주골조로 적용한 구조적 적합성이 검토되었다. 본 연구에서는 $IsoTruss^{(R)}$ 그리드(ITG) 구조의 예비단계 설계시 외주골조 부재의 소요단면적 산정방법을 제안하였다. 모듈의 변형과 하중과의 평형조건, 허용 횡변위, 그리고 건물의 휨변형 대 전단변형의 비를 변수로 하여 소요단면적을 유도하였다. ITG 구조에서 외주골조의 부재는 횡하중에 직각인 평면(PPR), 평행한 평면(PPL), 경사진 평면(POQ)에 배치되는데 POQ에 배치된 부재는 PPR 또는 PPL에 투영시켜 부재의 강성을 반영하였다. 소요단면적은 모듈에 작용하는 전단력과 모멘트에 의해 영향을 받는데 부재사이즈 조닝을 달리하여 3가지 모델을 비교하였다. 본 연구의 효용성을 검증하기 위해 64층 건물을 설계하여 해석하였다. 최대 횡변위, 철골량, 기둥의 축력강도비를 비교분석하여 부재사이즈 조닝의 효과를 알아보았다. 제안식을 이용한 횡변위가 제한치의 약 97.3%로 나와 제안식을 설계 초기단계에서 부재사이즈의 선정에 유용하게 적용할 수 있다.

비탄성변위비를 이용한 능력 스펙트럼법 (Capacity Spectrum Method Based on Inelastic Displacement Ratio)

  • 한상환;배문수
    • 한국지진공학회논문집
    • /
    • 제12권2호
    • /
    • pp.69-80
    • /
    • 2008
  • 본 연구에서는 중고층 건물과 같이 고차모드의 영향이 커지는 구조물의 지진에 대한 성능점을 간략하고 정확하게 구할 수 있는 개선된 능력스펙트럼법을 제안한다. 능력스펙트럼법은 주어진 지진의 응답스펙트럼과 다자유도 구조물을 변환한 등가 단자유도 시스템을 이용하여 지진으로 인하여 발생하는 지붕층의 최대 비탄성변위를 간략하게 구하는 방법이다. 제안된 방법에서는 구조물의 탄성 및 비탄성 동적해석을 수행하지 않고, 기존의 능력스펙트럼법에서 요구되는 정적푸쉬오버해석과 탄성변위를 이용하여 비탄성변위를 예측하는데, 기존 연구에서 개발한 $C_R$을 이용한다. 본 연구는 제안한 방법의 정확도를 평가하기 위해 LA 지역의 3, 9, 20층 철골모멘트저항골조를 선택한다. 이 건물들의 지진에 대한 각 층별 최대 층간변위비를 개발한 CSM으로 구하고, 이를 비선형 응답이력해석(NL-RHA)으로 구한 결과와 비교하였다. 사용한 지진은 재현주기 475년과 2475년의 위험수준에 대한 각각 20개의 지진집단들이다. 또한 본 연구에서는 ATC-40에 제시된 CSM 방법과 N2 방법으로 구한 각 건물의 최대 층간변위비도 비교한다. 개발된 CSM은 기존에 개발된 방법에 비하여 보다 정확한 최대 층간변위비를 예측하는 것으로 나타났다.

FEMA P695를 이용한 국내 저층 철골 중간모멘트골조의 반응수정계수 제안 (Proposition of Response Modification Factor of Low-rise Steel Intermediate Moment Frame in Korea using FEMA P695)

  • 한아름;김태완;유은종
    • 한국지진공학회논문집
    • /
    • 제18권1호
    • /
    • pp.37-43
    • /
    • 2014
  • In current seismic design code, steel moment frames are classified into ordinary, intermediate, and special moment frames. In the case of special moment frames which have large R-factor, economic design is possible by reducing the design lateral force. However, there is difficulty for practical application due to constraints such as strong column-weak beam requirement. This study evaluated if steel intermediate moment frame could maintain enough seismic capacity when the R-factor is increased from 4.5 to 6. As for the analytical models, steel moment frames of 3 and 5 stories were categorized into four performance groups according to seismic design category. Seismic performances of the frames were evaluated through the procedure based on FEMA P695. FEMA P695 utilizes nonlinear static analysis(pushover analysis) and nonlinear dynamic analysis(incremental dynamic analysis, IDA). In order to reflect the characteristics of Korean steel moment frames on the analytical model, the beam-column connection was modeled as weak panel zone where the collapse of panel zone was indirectly considered by checking its ultimate rotational angle after an analysis is done. The analysis result showed that the performance criteria required by FEMA P695 was satisfied when R-factor increased in all the soil conditions except $S_E$.