• Title/Summary/Keyword: 천공온도

Search Result 44, Processing Time 0.027 seconds

Calculation of Night Sky Temperature According to Cloudiness in Daegu (운량에 따른 대구지방의 야간 천공온도 산정)

  • Na, Wook-Ho;Lee, Jong-Won;Diop, Souleymane;Lee, Hyun-Woo
    • Current Research on Agriculture and Life Sciences
    • /
    • v.31 no.1
    • /
    • pp.38-44
    • /
    • 2013
  • To estimate the radiative heat loss from greenhouses, a new equation for calculating the sky temperature is presented. The sky temperature in the Daegu region was measured using a pyrgeometer and calculated using different equations according to the cloudiness. The calculated and measured results were then compared to identify the best equation for calculating the sky temperature. The difference value between the air and sky temperature was dissimilar and increased as the cloud amount decreased. On clear days the difference value was 10~20 times greater than that on cloudy and rainy days. When analyzing the correlationship between the calculated and measured sky temperatures on clear days, Bliss's and Clark & Allen's equations were found to be superior to the other equations. However, on cloudy days, the best correlationship between the calculated and measured sky temperatures was exhibited by Fuentes's equation. Therefore, a new equation is proposed for calculating the sky temperature on a cloudy day.

  • PDF

An Experimental Study on the Reduction Effects of Shading Devices on Sky Radiant Cooling in Winter (차양장치의 겨울철 천공복사 냉각 저감 효과에 관한 실험적 연구)

  • Kim, Jin-Hee;Kim, Young-Tag;Lee, Soo-Yeol;Choi, Won-Ki
    • Land and Housing Review
    • /
    • v.12 no.1
    • /
    • pp.129-137
    • /
    • 2021
  • External shading devices are well known solar control devices that can help reduce the cooling load of commercial buildings. For this study, experiments were conducted to examine the feasibility of shading devices in reducing both the cooling and heating loads. The influence of sky radiant cooling during winter was verified for the external shading device, internal roller blind, and window. Results can be summarized as follows. The temperature difference between the inner and outer surfaces of the window with the external shading device was 11.8℃ compared to 14.6℃ for one without the external shading device. This 2.8℃ difference was due to heat exchange by sky radiation when the surface temperature of the shading device was lower than the ambient outdoor air temperature. The roller blind resulted in a lower temperature of 0.8℃ compared to the average temperature of the window's air cavity. This was due to heat exchange by sky radiation of the roller blind surfaces. Without shading devices, the outside surface temperature of the window is about 3℃ higher. The study also found that when external shading devices were installed on both the southwest and southeast sides, the outside surface temperature of the windows were lower on the southwest side than the southeast side.

Effect of Drying method on the Fruit and Powder color of Red Pepper (건조방법이 고추 및 고춧가루의 색도에 미치는 영향)

  • Yoon, Wha-Mo;Lee, Jeong-Yeop
    • The Journal of Natural Sciences
    • /
    • v.15 no.1
    • /
    • pp.97-109
    • /
    • 2005
  • This experiment was established to find out the effect of drying methods on the fruit and powder color of red pepper. Hunter's L, a, and b values of the dried fruit were also higher with the cut fruit in comparison with the whole or punched fruit. The Hunter's a value of the pepper powder after drying and grinding was slightly higher for the whole fruit with sun drying, but it was higher for the cut fruit in case of heat drying. The ASTA value was higher when pepper fruits were sun dried. For the heat drying, the value was higher with the drying temperature $60^{\circ}C$.

  • PDF

A Study on the Characteristics of Fires Depending on the Existence of Boring on the Ceiling (천정 천공 유무에 따른 화재 특성 연구)

  • Rie, Dong-Ho;Choi, Back-Yeol;SeoMon, Su-Cheol;Yoo, Myung-Yeol
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.16-20
    • /
    • 2010
  • 본 연구는 지하 냉동 창고 화재발생시 천공이 화재진압의 방법으로써 화재성상에 미치는 영향 등 천공의 효과를 검증하고 화재진압 기술에 대한 기초연구로서 천공의 위치, 천공 개방 시간, 천공 개방에 따른 근접 건축물로의 화재 전파양상을 FDS를 통하여 시뮬레이션 하여 분석하였다. 천공의 개방은 내부 화재의 요인을 빨리 소모시켜 온도 및 발열량을 빠르게 낮춘다. 이와 같이 천공의 유무에 따라 화재에 양상이 바뀌기 때문에 화재 진행 사항 및 화재 장소 가연물에 형태 등 각 화재 형태에 따라 적절한 천공의 위치 및 개방시간등이 마련되어야 할 것이다.

  • PDF

Study on Reaction Rate of the Non-Explosive Demolition Agent (비폭성 파쇄재의 반응률 특성에 관한 연구)

  • ;Huipeng Ba
    • Tunnel and Underground Space
    • /
    • v.4 no.2
    • /
    • pp.87-91
    • /
    • 1994
  • 팽창재와 같은 비촉성 파쇄재는 화약발파와 비교하여 볼 때 진동을 유발하지 않는다는 면에서 인접한 구조물에 영향을 주지 않고 암반을 파괴할 수 있는 장점을 갖고 있다. 비폭성 파괴방법으로 유압식 암석분할기도 팽창재와 유사한 적용성을 갖고 있으나 힘을 작용시킬수 있는 천공깊이에 제약을 갖고 있으며 규모가 큰 암반의 파괴 방법으로는 적용한계가 있다. 반면에 팽창재는 천공깊이에 큰 제약을 받지 않으며 천공수에 제한을 받지 않는다는 장점이 있다. 그러나 팽창재의 현장적용시 가장 큰 단점의 하나로 지적되고 있는 것은 파괴력을 나타내기까지의 시간이 오래 걸림으로 작업능률에 문제가 있다는 것이다. 반응시간은 물과 팽창재와의 반응률과 밀접한 관계를 갖고 있으며 본 논문에서는 팽창재의 적용성을 높이기 위하여 실시한 여러 조건하에서 팽창재 반응률 특성에 관한 연구내용을 기술한다. 연구결과를 요약하면 다음과 같다. 1)팽창재의 반응은 주위온도에 큰 영향을 받는다. 2) 팽창재의 성능을 충분히 발휘하기 위하여는 주위 온도 조건에 따라 천공직경을 적절히 조절하는 것이 필요하다. 3) 낮은 주위 온도 조건에서 팽창재의 반응은 압력이 증가하는 시간이 느리고 따라서 최대 팽창압이 높은 온도 조건에 비해서 낮게 나타난다. 4)팽창압이 증가하는 시간은 팽창재와 물과의 반응률에 좌우된다.

  • PDF

Prediction of the Apparent Temperature of an Object under the Infrared Waveband (적외선 파장대에서의 물체의 겉보기온도 예측)

  • Jung, Jinsoo;Kauh, S. Ken;Yoo, Hoseon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.3
    • /
    • pp.352-363
    • /
    • 1999
  • Target detection by the infrared imager depends on the apparent temperature difference between the target and the background, so it is essential to predict apparent temperature variations for this purpose. In this study, thermal analysis program Including conduction, convection and radiation is developed and applied to a representative geometry adequate for examining the apparent temperature characteristics. The results show that the longwave emissivity in association with the background temperature affects the apparent temperature strongly but does not affect the physical temperature. It is revealed that the background temperature plays a role of tuning the apparent temperature. As the longwave emissivity decreases, the apparent temperature decreases when the target is hotter than the background, whereas it increases in the reversed situation. These findings imply that an effective surface treatment, such as painting of a less emissive material, may provide a less detection probability and contribute to preventing the target from being detected at night.

Measurement and Comparison of Overall Heat Transfer Coefficients for Greenhouse Covering Materials with Thermal Screens (온실용 피복재 및 보온재의 관류열전달계수 측정 및 비교)

  • Diop, Souleymane;Lee, Jong Won;Lee, Hyun Woo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.56 no.4
    • /
    • pp.41-51
    • /
    • 2014
  • 천공복사를 구현할 수 있는 관류열전달계수 측정용 실내실험장치를 제작하고 국내에서 사용되고 있는 온실 피복재 및 보온재의 관류열전달계수를 측정하여 실외실험에서 측정된 결과와 비교하여 타당성을 평가하였다. 외부피복은 0.1 mm 두께의 폴리에틸렌 필름을 사용하여 일중 및 이중피복으로 처리하였다. 이중외부피복조건의 경우 4가지 종류의 보온재를 처리하여 총 6가지 피복처리에 대하여 실험을 실시하였다. 모든 피복처리조건에 대하여 야간복사 유무에 따른 관류열전달계수 측정실험이 수행되었다. 천공복사의 유무에 따라 온실피복재의 관류열전달계수의 변화 경향이 크게 차이가 있었기 때문에 실내실험을 통해 관류열전달계수를 측정하기 위해서는 반드시 실제의 천공복사를 구현할 수 있는 실험장치가 필요할 것으로 판단된다. 실내 실험결과와 실외 실험결과가 비교적 잘 일치하였으며 실내실험장치를 이용하여 관류열전달계수를 측정하는 것이 타당성이 있음을 확인할 수 있었다. 천공복사 유무에 따른 관류열전달계수의 차이는 핫박스 내외부의 온도차이가 증가함에 따라 감소하는 것으로 나타났다.

Effects of Storage Temperature and Packaging Treatment on the Quality of Leaf Lettuce (상추 저장에 미치는 온도, 포장재료 및 유공 필름 영향)

  • Lee Jung-Soo;Chung Dae-Sung;Choi Ji-Weon;Jo Mi-Ae;Lee Youn-Suk;Chun Chang-Hoo
    • Food Science and Preservation
    • /
    • v.13 no.1
    • /
    • pp.8-12
    • /
    • 2006
  • The effects of packaging treatments with either low density polyethylene (LDPE) or polypropylene (PP) films on the quality of leaf lettuce were evaluated. It was also stored within a plastic bag (LDPE and PP films) with 4 pelf orated holes (6mm diameter). Changes in weight loss, color difference, anthocyanin, chlorophyll, water content, and general appearance (shape of lettuce) ware investigated Total weight of leaf lettuce packaged within non-pelf orated films decreased slowly over the storage periods at 5 and $20^{\circ}C$. The weight loss of leaf lettuce showed no significant difference between non-pelf orated and perforated films at $20^{\circ}C$. General appearance in leaf lettuce stored at $20^{\circ}C$ was not significantly affected by packaging treatments with LDPE and PP films. The shelf life of non-packaged leaf lettuce at $5^{\circ}C$ was 8 days, whereas packaging treatments with LDPE and PP films showed freshness in leaf lettuce for 30 days of storage. Total chlorophyll and water contents of leaf lettuce packaged within pelf orated and non-pelf orated films decreased gradually during storage. However, no remarkable changes in color difference, levels of chlorophyll and anthocyanin, and water contents were observed in leaf lettuce packaged within perforated and non-pelf orated films. In this experiment, leaf lettuce packaged within LDPE or PP films without any punching holes at $5^{\circ}C$ was the most desirable for extending the quality. These results suggest that non-pelf orated packaging treatment in combination with low storage temperature could be effective in prolonging the shelf life of leaf lettuce

Overall Heat Transfer Coefficient Measurement of Covering Materials with Thermal Screens for Greenhouse using the Hot Box Method (핫박스를 이용한 온실 피복재 및 보온재의 조합에 따른 관류열전달계수 측정)

  • Diop, Souleymane;Lee, Jong-Won;Na, Wook-Ho;Lee, Hyun-Woo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.5
    • /
    • pp.1-7
    • /
    • 2012
  • 본 연구의 목적은 국내에서 상용되고 있는 온실 피복재 및 보온재의 조합에 따른 관류열전달계수를 핫박스를 이용하여 평가하는 것이다. 온실용 일중 및 이중 피복재와 이중 보온재의 조합에 대하여 야간천공복사 차단여부에 따른 관류열전달계수를 핫박스를 이용하여 실외에서 측정하였다. 처리조건은 일중피복, 이중피복, 이중피복과 이중 마트보온재 및 이중피복과 이중 다겹보온재의 조합조건과 천공복사 유무에 따른 조건이며 총 8가지이다. 제작된 핫박스는 상시 변화하는 외부의 기상조건하에서도 내부온도를 설정된 온도로 일정하게 잘 유지할 수 있었다. 온실 피복재 및 보온재의 관류열전달계수를 측정하는 실내용 측정장치는 반드시 야간천공복사를 모의할 수 있는 측정장치가 되어야 할 것이다. 야간복사를 차단함으로서 온실의 열 손실을 줄여 보온효과를 얻을 수 있을 것으로 분석되었다. 모든 피복방식에 대해 야간복사 차단장치 유무에 관계없이 높은 풍속에서의 관류열전달계수가 낮은 풍속에서보다 더 큰 것으로 나타났다. 본 연구에서 사용된 측정기법을 사용하면 국내에서 생산되는 피복재 및 보온재의 관류열전달 특성을 정량적으로 비교할 수 있을 것으로 기대된다.

A Study on Optimum of Performance Objectives of Passive House with Load Reduction elements (천공상태에 따른 박막 BIPV 창호의 온도 및 발전특성 실측연구)

  • Kim, Bit-Na;Yoon, Jong-Ho;Shin, U-Cheu
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.171-176
    • /
    • 2012
  • This research on building Integrated Photovoltaic System replacing windows and doors with amorphous silicon thin film PV windows and doors installing same exact mount on Mock-up. The windows and doors should be installed in different angle and bearing so that we can analyse the amount of electricity from them. The objective of the research is to evaluate and investigate the relationship between factors(intensity of solar radiation, PV window surface temporature, incidence angle, and sky conditions) that affects performance of PV window and performance. The range and method of this research is to establish mornitoring system and analysis the date from the mornitoring system to evaluate the performance of PV windows that has thin film of solar battery. We should evaluate the insolation according to the position of PV window, output, and surface temperature according to months and seasons so that we can figure out the relationship between these. And we should investigate the relationship between performance and efficiency according to incidence angle and sky condition so that we can figure out the correlation between factors and performance.

  • PDF