• Title/Summary/Keyword: 척추 기구

Search Result 32, Processing Time 0.026 seconds

Evaluation of Set-up Accuracy for Frame-based and Frameless Lung Stereotactic Body Radiation Therapy (폐암 정위체부방사선치료 시 고정기구(frame) 사용 유무에 따른 셋업 정확성 평가)

  • Ji, Yunseo;Chang, Kyung Hwan;Cho, Byungchul;Kwak, Jungwon;Song, Si Yeol;Choi, Eun Kyung;Lee, Sang-wook
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.286-293
    • /
    • 2015
  • The purpose of this study was to evaluate the set up accuracy using stereotactic body frame and frameless immobilizer for lung stereotactic body radiation therapy (SBRT). For total 40 lung cancer patients treated by SBRT, 20 patients using stereotactic body frame and other 20 patients using frameless immobilizer were separately enrolled in each group. The setup errors of each group depending on the immobilization methods were compared and analyzed. All patients received the dose of 48~60 Gy for 4 or 5 fractions. Before each treatment, a patient was first localized to the treatment isocenter using room lasers, and further aligned with a series of image guidance procedures; orthogonal kV radiographs, cone-beam CT, orthogonal fluoroscopy. The couch shifts during these procedures were recorded and analyzed for systematic and random errors of each group. Student t-test was performed to evaluate significant difference depending on the immobilization methods. The setup reproducibility was further analyzed using F-test with the random errors excluding the systematic setup errors. In addition, the ITV-PTV margin for each group was calculated. The setup errors for SBF were $0.05{\pm}0.25cm$ in vertical direction, $0.20{\pm}0.38cm$ in longitudinal direction, and $0.02{\pm}0.30cm$ in lateral direction, respectively. However the setup errors for frameless immobilizer showed a significant increase of $-0.24{\pm}0.25cm$ in vertical direction while similar results of $0.06{\pm}0.34cm$, $-0.02{\pm}0.25cm$ in longitudinal and lateral directions. ITV-PTV margins for SBF were 0.67 cm (vertical), 0.99 cm (longitudinal), and 0.83 cm (lateral), respectively. On the other hand, ITV-PTV margins for Frameless immobilizer were 0.75 cm (vertical), 0.96 cm (longitudinal), and 0.72 cm (lateral), indicating less than 1 mm difference for all directions. In conclusion, stereotactic body frame improves reproducibility of patient setup, resulted in 0.1~0.2 cm in both vertical and longitudinal directions. However the improvements are not substantial in clinic considering the effort and time consumption required for SBF setup.

Analysis of Compression Behavior on Intervertebral Disc L4-5 in Pedicle Screw System Instrumented Lumbar Spine under Follower Load (척추경 나사못을 이용한 척추 유합술에서 고정범위에 따른 인접 추간판의 압축 거동 분석)

  • Ahn, Myun-Whan;Ahn, Jong-Chul;Lee, Su-Ho;Chung, Il-Sub;Lee, Choon-Yeol;Lee, Jang-Woo
    • Journal of Yeungnam Medical Science
    • /
    • v.20 no.2
    • /
    • pp.160-168
    • /
    • 2003
  • Background: Confirm the stability of intervertebral disc sustaining each fused lumbar spine cases, comparing vertical compression, A-P shear force and rotational moment on intervertebral disc of instrumented lumbar spine with simple vertical compression load and follower load using finite element analysis. Materials and Methods: We analyze the stability of intervertebral disc L4-5 supporting fused lumbar spine segments. After performing finite element modelling about L1-L5 lumbar vertebral column and L1-L4 each fusion level pedicle screw system for fused lumbar spine fine element model. Intervertebral discs with complex structure and mechanical properties was modeled using spring element that compensate stiffness and tube-to-tube contact element was employed to give follower load. Performing geometrical non-linear analysis. Results: The differences of intervertebral disc L4-5 behavior under the follower compression load in comparision with vertical compression load are as follows. Conclusion: As a result of finite element interpretation of instrumented lumbar spine, the stability of L4-5 sustaining fused lumbar segment, the long level fused lumbar spine observed hing stability under follower load. This research method can be the basis tool of effects prediction for instrumentation, a invention of a more precious finite element interpretation model which consider the role of muscle around the spine is loaded.

  • PDF

Anterolateral Surgical Decompression and Instrumentation in Thoracolumbar Bursting Fracture (외상성 흉요추접합부 파열골절의 전측방경유법에 의한 신경감압 및 기구고정술)

  • Bae, Jang-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.13 no.2
    • /
    • pp.234-242
    • /
    • 1996
  • Ten patients with a thoracolumbar spine fractures were treated with Kaneda internal fixation device through anterolateral approach during last 1 year. In all cases, spinal decompression, internal instrument fixation and hone fusion with rib were performed. No patient showed neurological deterioration after surgery and 6(60%) patients improved postoperatively with entering the next Frankel subgroup. Follwo-up patient evaluation showed the correction of the fracture deformity with good bony fusion, but 3 patient arc remained back pain. According to above results we concluded that anterolateral internal fixation combined with hone fusion using rib was good mechanical stability and decompression of protruding ventral bone fragments above conus medullaris level.

  • PDF

Biomechanical Analysis of Lumbar Interspinous Process Fixators and Design of Miniaturization and Advanced Flexibility (요추부 극돌기간 고정기구의 생체역학적 해석과 소형화 및 유연성 향상 설계)

  • Park, Jung-Hong;Heo, Soon;Lee, Sung-Jae;Son, Kwon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.12 s.255
    • /
    • pp.1509-1517
    • /
    • 2006
  • The intervertebral fusion was reported to increase the degeneration of the neighboring region. Recently, a new technique of inserting an interspinous process fixator has been introduced to minimize the degenerative change in the lumbar spine. This study analyzed biomechanical effects of the fixator in the lumbar spine, and designed a new prototype to improve flexibility of the fixator with a reduced size. The evaluation was based on the displacement, stiffness and von-Mises stress obtained from the mechanical test and finite element analysis. A finite element lumbar model of L1 to L5 was constructed. The finite element model was used to analyze intervertebral fusion, insertion of a commercial fixator and a new prototype. The range of motion of intervertebral segments and pressures at vertebral discs were calculated from FEA. The results showed that the stiffness of the prototype was reduced by 32.9% than that of the commercial one.

Design and Implementation of Open GIS OLE DB Component Using RDBMS (RDBMS를 이용한 개방형 GIS OLE DB 제공자 컴포넌트의 설계 및 구현)

  • Kim, Min-Soo;Lee, Ki-Won;Lee, Jong-Hun
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2000.10a
    • /
    • pp.67-70
    • /
    • 2000
  • 최근 네트워크 서비스 및 분산 컴퓨팅 환경의 급격한 발전과 더불어 인터넷 기반 지리정보 시스템과 이 기종 시스템간에 상호 운용성을 지원하는 분산 지리정보시스템의 기술이 혁신적으로 발전하게 되었다. 현재 이러한 상호 운용성과 더불어 기 구축된 시스템의 재 사용성을 극대화하기 위하여 개방형 컴포넌트 소프트웨어 기술이 발표[1]되었으며, 최근 발표되는 지리정보시스템들도 이러한 개방화와 컴포넌트화 기술을 채택하여 개발되고 있다. 이러한 개방형 컴포넌트 소프트웨어 기술은 컴퓨터 소프트웨어 산업 전반에 커다란 파급 효과를 끼치고 있다. 지리정보시스템 분야에서는 OpenGIS Consortium(OGC)을 주축으로 하여 개방형 컴포넌트 지리정보시스템을 위한 표준 구현 사양을 발표하고 있으며, 이러한 표준 사양을 수용한 제품들이 개발되고 있는 실정이다. 본 논문에서는 분산 환경에서 다양한 관계형 데이터베이스시스템을 이용하여 OGC가 제시한 OLE/COM 기반의 데이터 제공자 컴포넌트의 설계 및 구현에 중점을 두고 있다. 본 시스템의 데이터 제공자 컴포넌트는 순수한 관계형 데이터베이스시스템 기반 위에서 구성되므로, 우선 OGC에서 요구하는 GIS 관련 핵심 기능들을 제공하기 위해서 우선 관계형 데이터베이스와 ODBC를 이용하여 공간엔진을 구성하고 있다. 본 공간 엔진은 OGC 사양을 충족하기 위해서 이용되는 최소한의 기능-공간데이터 관리 기능, 공간 연산 처리, 공간 색인 기능 그리고 클라이언트와 통신하기 위한 기능-들을 포함하고 있다. 그러므로 본 논문에서는 이러한 공간 엔진의 기반 위에서 OGC OLE DB 제공자 컴포넌트의 설계 및 구현 방법에 대해서 자세히 살펴보고 실제 SQL Server 7.0 환경에서 구축된 공간 엔진 및 OLE DB 제공자 컴포넌트의 구현 예에 대하여 살펴볼 것이다. 혈액내방사선 조사량이 안전용량 범위(200rad)에 속하며 48시간 후 체내잔류량은 서양인과 큰 차이가 없었다.비출현의 소견을 보이는 악성종양 환자의 골 신티그람 53개중 44개 (83.0%)에서 척추 및 늑골에 미만성, 또는 다발성 침습이 관찰되었다. 또 골전이 부위를 두개골, 척추, 견대부, 늑골, 골반, 사지의 근위부 장골의 6개 부위로 나누어 분석할 경우 49개(92.5%)에서 3부위 이상에 전이가 발견되었고, 35개(66.0%)에서 4부위 이상에 전이가 발견되었으며, 5부위 이상, 6개 부위에 모두 전이가 발견된 것은 각각 20개 (37 7%), 11개(20.8%)이었다. 이상의 성적으로 보아 악성종양 환자의 골 신피그라피에서 신장 영상의 비출현은 종양의 광범위한 골전이를 간접적으로 시사하는 소견으로 생각된다. 여러 악성종양중 전립선암에서 신장 영상 비출현의 빈도가 가장 높았으며, 특히 위암에서 골전이 및 신장 영상 비출현의 빈도가 높음은 주목할 만한 것이라 하겠다.출한 결과 인,규소 증가와 자가영양성 미소플랑크톤(ANP)증가에 미치는 요인이 해안과 외해에서 동일하게 가장 큰 설명력을 보였다. N:P 비도 해안에서 36.4, 외해에서 32.6을 보이고 있어 인이 상당히 부족한 것으로 나타났다. 따라서 조사해역은 인이 식물플랑크톤 성장에 중요한 제한요인으로 작용하고 있다고 판단된다.의 회전. 전위력의 강도, 적용시점, 그리고 키, 체중등의 신체적 요인 등이 있으나 능숙한 기계사용과 정확한 슬관절 위치에서 검사할 때 전방 십자 인대 파열에 대한 진단에 유용한 기구이다.태라고 하였다. 본 연구에서는 이러한 근거를 바탕으로 개방형 문제의 유형을 다양한 답이 존재하는 문제, 다양한 해결 전략이 가능한 문제, 답이 없는 문제, 문제 만들기, 일반화가 가능한 문제 등으로 보고, 수학적 창의성 중

  • PDF

Development of Multi-Body Dynamics Simulator for Bio-Mimetic Motion in Lizard Robot Design (도마뱀 로봇 설계를 위한 생체운동 모사 다물체 동역학 시뮬레이터 개발)

  • Park, Yong-Ik;Seo, Bong Cheol;Kim, Sung-Soo;Shin, Hocheol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.6
    • /
    • pp.585-592
    • /
    • 2014
  • In this study, a multibody simulator was developed to analyze the bio-mimetic motion of a lizard robot design. A RecurDyn multibody dynamics model of a lizard was created using a micro-computerized tomography scan and motion capture data. The bio-mimetic motion simulator consisted of a trajectory generator, an inverse kinematics module, and an inverse dynamics module, which were used for various walking motion analyses of the developed lizard model. The trajectory generation module produces spinal movements and gait trajectories based on the lizard's speed. Using the joint angle history from an inverse kinematic analysis, an inverse dynamic analysis can be carried out, and the required joint torques can be obtained for the lizard robot design. In order to investigate the effectiveness of the developed simulator, the required joint torques of the model were calculated using the simulator.

Long Term Clinical and Radiological Follow-up Study in Spondylolisthesis, Grade I : Decompression with or without Instrument (GradeⅠ요추부 척추 전방 전위증의 치료 : 감압성 후궁절제술과 고정기구 삽입술의 비교)

  • Chung, Seung Young;Kim, Gook Ki;Lim, Young Jin;Kim, Tae Sung;Leem, Won;Rhee, Bong Arm
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup2
    • /
    • pp.235-241
    • /
    • 2001
  • Objective : Controversy exists which surgical treatment better in lumbar grade I spondylolisthesis, decompressive laminectomy with or without lumbar instrumentation. Methods : Out of Sixty-four patients with lumbar spondylolisthesis underwent surgery, 18 patients operated with decompressive laminectomy alone and 44 patients with decompession and lumbar instrument, during recent 5-years between January, 1994 and December, 1998. The author studied a long term follow-up in the above two groups to analyzing the overall clinical outcomes in each group and to determining the incidence of pos-toperative radiologic instability. Results : 1) Overall postoperative symptoms improvement were not so different in both groups. 2) Postoperative progressive subluxation is more common after decompressive laminectomy without instrumentation than with instrumentation group. 3) Overall clinical outcomes were slightly better in decompressive laminectomy without instrumentation than with instrumentation group but there was no significant difference. 4) Postoperative radiologic changes did not seem to influence the patient-reported clinical outcomes. 5) Postoperative complications is more common in decompressive laminectomy with instrumentation group than without instrumentation group. Conclusion : In the surgical management of grade I spondylolisthesis, the efficiency and superiority of surgical treatments requires the cost effectiveness and risk/benefit analysis of decompressive laminectomy with or without instrumentation. Therefore, Further detailed studies of long term follow up in a large number of patients in each group are needed for choice of best treatment.

  • PDF

Mechanical Stability of TiN and DLC Coated Instrument of Pedicle Screw System (TiN 및 DLC 코팅된 척추경나사못시스템 수술기구의 기계적 안정성 분석)

  • Kang, Kwan-Su;Jung, Tae-Gon;Yang, Jae-Woong;Woo, Su-Heon;Park, Tea-Hyun;Jeong, Yong-Hoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.52 no.3
    • /
    • pp.163-170
    • /
    • 2019
  • Durability of instrument is one of the most important factor to ensure accurate treatment and decrease failure for the orthopedic surgical operation. Normally, a set-screw driver tip has been processed with hard coating for their higher durability and wear resistance. And several surface modification methods were obtained such as titanium nitride (TiN) coating, diamond like carbon coating, other nitriding, and etc. In this study, we have surface modified on set-screw driver tip with TiN and DLC, investigated whether the TiN and DLC coatings affect the mechanical properties and durability of the set-screw driver tip in the pedicle screw system. The surface morphologies were observed with scanning-electron microscopy (SEM), and the static/dynamic torsional properties were investigated with universal testing machine based on ASTM F543. Coating thickness of each coatings were commonly around $1^{\circ}C$. Static torsional stiffness, and ultimate torque values for DLC and TiN coated samples were significantly higher than those of non-coated sample by the pared T-test. Surface morphology of after the dynamic torsional test was more clean with less scratch or friction traces from DLC coating than that of TiN coating and non-coated sample.

Prevalence of Osteoporosis among Male Adults with Apparently Radiolucent Lumbar Vertebral Bodies on the Plain Radiographs (단순 영상에서 요추체의 음영이 감소된 성인 남성에서의 골다공증 유병률)

  • Kim, Kook Jong;Lim, Sung Joon;Kim, Yong Min;Lee, Hyung Ki;Kim, Geon Jung
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.6
    • /
    • pp.491-497
    • /
    • 2021
  • Purpose: To investigate the prevalence of osteoporosis or osteopenia via dual-energy X-ray absorptiometry bone mineral density (DEXA BMD) in adult males who showed radiolucent lumbar vertebra on the plain radiographs. Materials and Methods: The DEXA BMD values of 98 adult males, who showed radiolucent vertebrae on plain X-rays, were compared with those of the control group (n=168) and osteoporosis-related fracture group (n=113) by statistical analysis. The World Health Organization (WHO) method (lower value between the mean lumbar and femur neck) and the Hansen's method (lowest lumbar vertebra) were used to determine osteoporosis. Results: The mean and standard deviation of the BMD value of each group was -1.4 (±1.2) in the suspicious group, -0.8 (±1.1) in the control group, and -2.4 (±1.0) in the fracture group, respectively; the difference was statistically significant. Using the WHO method, the prevalence ratio of osteoporosis was 17.3% in the suspicious group, 8.3% in the control group, and 45.1% in the fracture group, respectively. Osteopenia was observed in 40.8% of the suspicious group. Hansen's method (lowest lumbar vertebra) revealed the prevalence of osteoporosis in 30.6% of the suspicious group, 17.9% of the control group, and 62.0% of the fracture group. Conclusion: Approximately 17.3% of the suspicious group was diagnosed with osteoporosis, and 40.8% were osteopenic by a confirmative BMD study (WHO criteria) among the adult males showing apparent radiolucency on plain X-rays. The control group also showed an 8% prevalence of osteoporosis. These results suggest that males also are vulnerable to osteoporosis. Therefore, a BMD study should also be used for males, especially for the people showing lumbar vertebrae with radiolucent features.

Biomechanical Analysis of a Combined Interspinous Spacer with a Posterior Lumbar Fusion with Pedicle Screws (척추경나사못을 이용한 유합술과 동반 시술된 극돌기간 삽입기구의 생체역학적 연구)

  • Kim, Y.H.;Park, E.Y.;Lee, S.J.
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.6
    • /
    • pp.276-282
    • /
    • 2015
  • Recently, during the multi-level fusion with pedicle screws, interspinous spacer are sometimes substituted for the most superior level of the fusion in an attempt to reduce the number of fusion level and likelihood of degeneration process at the adjacent level. In this study, a finite element (FE) study was performed to assess biomechanical efficacies of the interspinous spacer combined with posterior lumbar fusion with a previously-validated 3-dimensional FE model of the intact lumbar spine (L1-S1). The post-operative models were made by modifying the intact model to simulate the implantation of interspinous spacer and pedicle screws at the L3-4 and L4-5. Four different configurations of the post-op model were considered: (1) a normal spinal model; (2) Type 1, one-level fusion using posterior pedicle screws at the L4-5; (3) Type 2, two-level (L3-5) fusion; (4) Type 3, Type 1 plus Coflex$^{TM}$ at the L3-4. hybrid protocol (intact: 10 Nm) with a compressive follower load of 400N were used to flex, extend, axially rotate and laterally bend the FE model. As compared to the intact model, Type 2 showed the greatest increase in Range of motion (ROM) at the adjacent level (L2-3), followed Type 3, and Type 1 depending on the loading type. At L3-4, ROM of Type 2 was reduced by 34~56% regardless of loading mode, as compared to decrease of 55% in Type 3 only in extension. In case of normal bone strength model (Type 3_Normal), PVMS at the process and the pedicle remained less than 20% of their yield strengths regardless of loading, except in extension (about 35%). However, for the osteoporotic model (Type 3_Osteoporotic), it reached up to 56% in extension indicating increased susceptibility to fracture. This study suggested that substitution of the superior level fusion with the interspinous spacer in multi-level fusion may be able to offer similar biomechanical outcome and stability while reducing likelihood of adjacent level degeneration.