• Title/Summary/Keyword: 처리

Search Result 102,442, Processing Time 0.108 seconds

Development and Evaluation of Model-based Predictive Control Algorithm for Effluent $NH_4-N$ in $A^2/O$ Process ($A^2/O$ 공정의 유출수 $NH_4-N$에 대한 모델기반 예측 제어 알고리즘 개발 및 평가)

  • Woo, Dae-Joon;Kim, Hyo-Soo;Kim, Ye-Jin;Cha, Jae-Hwan;Choi, Soo-Jung;Kim, Min-Soo;Kim, Chang-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.1
    • /
    • pp.25-31
    • /
    • 2011
  • In this study, model-based $NH_4-N$ predictive control algorithm by using influent pattern was developed and evaluated for effective control application in $A^2/O$ process. A pilot-scale $A^2/O$process at S wastewater treatment plant in B city was selected. The behaviors of organic, nitrogen and phosphorous in the biological reactors were described by using the modified ASM3+Bio-P model. A one-dimensional double exponential function model was selected for modeling of the secondary settlers. The effluent $NH_4-N$ concentration on the next day was predicted according to model-based simulation by using influent pattern. After the objective effluent quality and simulation result were compared, the optimal operational condition which able to meet the objective effluent quality was deduced through repetitive simulation. Next the effluent $NH_4-N$ control schedule was generated by using the optimal operational condition and this control schedule on the next day was applied in pilot-scale $A^2/O$ process. DO concentration in aerobic reactor in predictive control algorithm was selected as the manipulated variable. Without control case and with control case were compared to confirm the control applicability and the study of the applied $NH_4-N$control schedule in summer and winter was performed to confirm the seasonal effect. In this result, the effluent $NH_4-N$concentration without control case was exceeded the objective effluent quality. However the effluent $NH_4-N$ concentration with control case was not exceeded the objective effluent quality both summer and winter season. As compared in case of without predictive control algorithm, in case of application of predictive control algorithm, the RPM of air blower was increased about 9.1%, however the effluent $NH_4-N$ concentration was decreased about 45.2%. Therefore it was concluded that the developed predictive control algorithm to the effluent $NH_4-N$ in this study was properly applied in a full-scale wastewater treatment process and was more efficient in aspect to stable effluent.

Application of Enhanced Coagulation for Nakdong River Water Using Aluminium and Ferric Salt Coagulants (낙동강 원수를 대상으로 Al염계 및 Fe염계 응집제를 이용한 고도응집의 적용)

  • Moon, Sin-Deok;Son, Hee-Jong;Yeom, Hoon-Sik;Choi, Jin-Taek;Jung, Chul-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.9
    • /
    • pp.590-596
    • /
    • 2012
  • Enhanced coagulation is best available technologies to treat NOM in water to produce clean drinking water. In this research, the comparison experiments between conventional coagulation (CC) and enhanced coagulation (EC) using 4 type coagulants i.e., ferric chloride, aluminium sulphate (alum), poly aluminium sulphate organic magnesium (PSOM) and poly aluminium chloride (PACl) were performed in terms of surrogate parameters such as dissolved organic carbon (DOC), trihalomethane formation potential (THMFP), haloacetic acid formation potential (HAAFP) and zeta potential variation in order to find out the most effective coagulant and conditions to fit Nakdong River water. When applied to EC process, the turbidity removal efficiency did not increased gradually compared to the CC process when adding coagulants. Furthermore, the removal efficiency of turbidity became decreased much more as coagulants were added increasingly whereas the removal efficiency of DOC, THMFP and HAAFP became increased by 13~18%, 9~18% and 9~18% respectively compared to the CC process. The characteristics of turbidity removal showed relatively high removal efficiency considering the pH variation in entire pH range when using $FeCl_3$ and PACl. Additionally, in case of alum and PSOM steady removal efficiency was shown between pH 5 and pH 8. In terms of DOC surrogate the coagulants including 4 type coagulants indicated high removal efficiency between pH 5 and pH 7. The removal efficiency of dissolved organic matter (DOM) in EC between less than 1 kDa and more than 10 kDa augmented by 11~21% and 16% respectively compared to the CC process. The removal efficiency of hydrophobic and hydrophilic organic matter proved to be increased by 27~38% and 11~15% respectively. In conclusion, the most effective coagulant relating to EC for Nakdong River water was proved to be $FeCl_3$ followed by PSOM, PAC and alum in order.

Application of Reused Powdered Waste Containing Aluminum Oxide on the Treatment of Cr(VI) (6가 크롬 처리를 위한 알루미늄 산화물을 함유한 재생 분말 폐기물의 적용)

  • Lim, Jae-Woo;Kim, Tae-Hwan;Kang, Hyung-Sik;Kim, Do-Son;Kim, Han-Seon;Cho, Seok-Hee;Yang, Jae-Kyu;Chang, Yoon-Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.3
    • /
    • pp.179-185
    • /
    • 2009
  • In this research, the removal capacity of Cr(VI) by the reused powdered wastes (RPW) containing aluminium oxides was studied. As a pre-treatment process for the preparation of calcined wastes, calcination was conducted at $550^{\circ}C$ to remove organic fraction in the raw wastes. In order to study the adsorption trend of Cr(VI) ions from aqueous solutions, the pH-edge adsorption, adsorption kinetic and adsorption isotherm were investigated using a batch reactor in the presence of four different background electrolytes($NO_3\;^-,\;CO_3\;^{2-},\;SO_4\;^{2-},\;PO_4\;^{3-}$). Cr(VI) adsorption was greatly reduced in the presence of $SO_4\;^{2-}$ and $PO_4\;^{3-}$ over the entire pH range. Meanwhile the inhibition effect by $NO_3\;^-$ and $CO_3\;^{2-}$ was relatively lower than that by $SO_4\;^{2-}$ and $PO_4\;^{3-}$. Cr(VI) adsorption was maximum around pH 4.5 in the presence of $NO_3\;^-$ and $CO_3\;^{2-}$. As the concentration of background electrolytes increased, Cr(VI) adsorption decreased. This result mightly suggests that adsorption between the surface of RPW and Cr(VI) occurs through outer-sphere complex. Cr(VI) adsorption onto the RPW was well described by second-order kinetics. From the Langmuir isotherm at initial pH 3, the maximum adsorbed amount of Cr(VI) onto the RPW was 11.1, 10, 3.3, 5 mg/g in the presence of $NO_3\;^-,\;CO_3\;^{2-},\;SO_4\;^{2-}$, and $PO_4\;^{3-}$, respectively.

Computing the Dosage and Analysing the Effect of Optimal Rechlorination for Adequate Residual Chlorine in Water Distribution System (배.급수관망의 잔류염소 확보를 위한 적정 재염소 주입량 산정 및 효과분석)

  • Kim, Do-Hwan;Lee, Doo-Jin;Kim, Kyoung-Pil;Bae, Chul-Ho;Joo, Hye-Eun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.10
    • /
    • pp.916-927
    • /
    • 2010
  • In general water treatment process, the disinfection process by chlorine is used to prevent water borne disease and microbial regrowth in water distribution system. Because chlorines were reacted with organic matter, carcinogens such as disinfection by-products (DBPs) were produced in drinking water. Therefore, a suitable injection of chlorine is need to decrease DBPs. Rechlorination in water pipelines or reservoirs are recently increased to secure the residual chlorine in the end of water pipelines. EPANET 2.0 developed by the U.S. Environmental Protection Agency (EPA) is used to compute the optimal chlorine injection in water treatment plant and to predict the dosage of rechlorination into water distribution system. The bulk decay constant ($k_{bulk}$) was drawn by bottle test and the wall decay constant ($k_{wall}$) was derived from using systermatic analysis method for water quality modeling in target region. In order to predict water quality based on hydraulic analysis model, residual chlorine concentration was forecasted in water distribution system. The formation of DBPs such as trihalomethanes (THMs) was verified with chlorine dosage in lab-scale test. The bulk decay constant ($k_{bulk}$) was rapidly decreased with increasing temperature in the early time. In the case of 25 degrees celsius, the bulk decay constant ($k_{bulk}$) decreased over half after 25 hours later. In this study, there were able to calculate about optimal rechlorine dosage and select on profitable sites in the network map.

Evaluation of the Removal Characteristics of Pollutants in Storm Runoff Depending on the Media Properties (여재 특성에 따른 강우 유출수 내 오염물질 제거특성 평가)

  • Kim, Tae-Gyun;Cho, Kang-Woo;Song, Kyung-Guen;Yoon, Min-Hyuk;Ahn, Kyu-Hong;Hong, Sung-Kwan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.7
    • /
    • pp.483-490
    • /
    • 2009
  • The aims of this study were to evaluate the removal efficiency for various pollutants in urban storm runoff by a filtration device, and to determine design parameters depending on filter media properties. Appropriate selection of filter media will affect the size and life time of the filtration device. Sets of column tests were performed in order to evaluate the removal efficiency by perlite and a synthetic resin. An investigation of surface properties including CEC (cation exchange capacity) and zeta-potential suggested that the perlite had a superior adsorption capability for cationic pollutants. TCODcr and turbidity were analyzed to investigate the removal characteristic of particulate pollutant. In both columns, the particles in the collected storm runoff was almost completely capture with a small EBCT (empty bed contact time) of 2.5 minutes. Complete clogging at the EBCT of 2.5 minutes occurred after 630 minutes in the perlite column and 810 minutes in the resin column. The removal efficiency of TCODcr and turbidity at the EBCT of 2.5 minutes decreased to below 70% due to an wall effect. The removal efficiency for dissolved pollutant (SCODcr) was negligible due to the insufficient contact time for adsorption. The removal of heavy metals (Cu, Zn, Pb) was mostly ascribed to the filtration of particles containing metals, since the relationship between CEC and the removal efficiency was not apparent. The result of this study would be valuable for the application of filtration device to control of urban storm runoff.

Study on Synthesis of Pyrochlore in Gd-Ti-O and Gd-Zr-O Systems (Gd-Ti-O계 및 Gd-Zr-O 계에서의 파이로클로어 합성연구)

  • ;;;S.V. Yudintsev
    • Economic and Environmental Geology
    • /
    • v.37 no.3
    • /
    • pp.303-309
    • /
    • 2004
  • Pyrochlores were known as promising materials for the immobilization of radioactive actinide. Accordingly, we synthesized pyrochlores with Gd$_2$Ti$_2$$O_7$ and Gd$_2$Zr$_2$$O_7$compositions by sintering method, and studied its properties and phase relations in Gd-Ti-O and Gd-Zr-O system. The mixed powders were pressed into pellets under 200-400 kgf/cm$^2$ at room temperature. and then sintered at 1000-1$600^{\circ}C$ for 0.5-40 hours. The synthesized samples were analyzed and were identified with XRD and SEM/EDS analyses. The optimal synthetic conditions of pyrochlores with Gd$_2$Ti$_2$$O_7$composition were at 140$0^{\circ}C$/0.5hrs, 130$0^{\circ}C$/3hrs and 120$0^{\circ}C$/20hrs. Its chemical composition was $Gd_{2.0-2.1}$$Ti_{1.9-2.0}$$O_7$ and similar to the stoichiometric composition without any relationship in temperature and atmosphere. The optimal synthetic conditions of pyrochlores with $Gd_{2}$$Zr_{2}$$O_7$composition were at 155$0^{\circ}C$/40hrs and 1$600^{\circ}C$/30hrs. The compositions of pyrochlore synthesized from these optimal conditions were irregular with $Gd_{1.5-2.4}$$Zr_{1.7-2.4}$$O_7$. Such heterogeneity indicates that the reaction rate of pyrochlore with Gd$_2$Zr$_2$$O_7$composition is very low, and then its equilibrium state could not be attained even for 40 hours which was the longest sintering time in this research.

S-wave Velocity Derivation Near the BSR Depth of the Gas-hydrate Prospect Area Using Marine Multi-component Seismic Data (해양 다성분 탄성파 자료를 이용한 가스하이드레이트 유망지역의 BSR 상하부 S파 속도 도출)

  • Kim, Byoung-Yeop;Byun, Joong-Moo
    • Economic and Environmental Geology
    • /
    • v.44 no.3
    • /
    • pp.229-238
    • /
    • 2011
  • S-wave, which provides lithology and pore fluid information, plays a key role in estimating gas-hydrate saturation. In general, P- and S-wave velocities increase in the presence of gas-hydrate and the P-wave velocity decreases in the presence of free gas under the gas-hydrate layer. Whereas there are very small changes, even slightly increases, in the S-wave velocity in the free gas layer because S-wave is not affected by the pore fluid when propagating in the free gas layer. To verify those velocity properties of the BSR (bottom-simulating reflector) depth in the gas-hydrate prospect area in the Ulleung Basin, P- and S-wave velocity profiles were derived from multi-component ocean-bottom seismic data which were acquired by Korea Institute of Geoscience and Mineral Resources (KIGAM) in May 2009. OBS (ocean-bottom seismometer) hydrophone component data were modeled and inverted first through the traveltime inversion method to derive P-wave velocity and depth model of survey area. 2-D multichannel stacked data were incorporated as an initial model. Two horizontal geophone component data, then, were polarization filtered and rotated to make radial component section. Traveltimes of main S-wave events were picked and used for forward modeling incorporating Poisson's ratio. This modeling provides S-wave profiles and Poisson's ratio profiles at every OBS site. The results shows that P-wave velocities in most OBS sites decrease beneath the BSR, whereas S-wave velocities slightly increase. Consequently, Poisson's ratio decreased strongly beneath the BSR indicating the presence of a free gas layer under the BSR.

Examination for Efficiency of Groundwater Artificial Recharge in Alluvial Aquifer Near Nakdong River of Changweon Area, Korea (창원지역 낙동강 하천수와 주변 충적층을 이용한 지하수 인공함양의 효율성 평가)

  • Moon, Sang-Ho;Ha, Kyoochul;Kim, Yongcheol;Koh, Dong-Chan;Yoon, Heesung
    • Economic and Environmental Geology
    • /
    • v.47 no.6
    • /
    • pp.611-623
    • /
    • 2014
  • The alluvial aquifer, widely developed near the four major rivers such as Nakdong River, can be used effectively for groundwater artificial recharge and is expected to be the future water resources in Korea. This study is aimed at examining the impact of repeatedly injected river water into the riverside alluvial aquifer on injection rate or efficiency in its system at Changweon area. For this, injection tests were performed two times, first on June 19 and second on September 25 through October 9, 2013, and the mixing ratios of river water to groundwater were used as the tool to compare the efficiency of injection. The mixing ratios were evaluated by using electrical conductivities of injected river water (average $EC=303{\mu}S/cm$) and groundwater ($EC{\fallingdotseq}6,000{\mu}S/cm$) measured at 20 m depth of four observation wells installed 10 m apart from each injection well. The result shows the remarkable differences on two respects. First, in some observation well, detection time for incipient injection effect during $2^{nd}$ injection test was shown to be much slower than that of $1^{st}$ injection test. Second, the hourly increasing rate of mixing ratios in $2^{nd}$ test was revealed to be reduced much more than that of $1^{st}$ test. This means that the efficiency of injection was badly deteriorated by only 1,210 minute injection work. Therefore, injection water needs to be adequately treated beforehand and repeated pumping work and/or resting phase is needed afterwards. To a certain extent, the improvement of water quality in saline aquifer was verified in this system by injection tests.

Quantitative Descriptive Analysis and Principal Component Analysis for Sensory Attributes of Commercial Milk Preserved at Different Temperature (보존온도를 달리한 상업적 우유제품의 묘사적 관능분석 및 PCA 분석)

  • Chung, Seo-Jin;Noh, Bong-Soo;Ju, Jong-Cheol;Lee, Min-Hyang;Park, Seung-Yong
    • Journal of Dairy Science and Biotechnology
    • /
    • v.29 no.2
    • /
    • pp.25-35
    • /
    • 2011
  • The objectives of this study were to evaluate the sensory characteristic quality of commercial milk brands selling in the market under the preservation at the temperature of $7^{\circ}C$ and $10^{\circ}C$ stored during the period of shelf-life. Quantitative descriptive analysis after developing of descriptive terms and cluster characterization by PCA analysis over a total of 128 LTLT, HTST, UHT and UHT-ESL milks, were conducted by 8 trained panelists. A total of fourteen attributes; three aroma attributes (grassy, milky, cultured milk aroma) and seven flavor/taste attributes (sweet, salty, sour, milk, cooked, cheesy, paper board) and one aftertaste attributes (rancid flavor) and one texture attributes (viscous), were developed as descriptive terms. Significant differences (P<0.01) in the sensory attributes; sweet, milky, cheesy etc. in UHT milk and sour, cheesy, paper board, rancid etc. in UHT-ESL milk were also found between the two different temperatures within the shelf life, but both type of pasteurized milk samples (LTLT and HTST) showed significant differences (P<0.01) in the attributes, such as cultured milk aroma, salty, sour, cheesy, rancid in LTLT milk and grassy, milky, salty in HTST milk and difference (P<0.05) in cultured milk aroma for HTST milk. Therefore, from the viewpoint of not only hygienic quality but also sensory characteristics, it is required for the better acceptance of milk consumers to amendment on the regulation in relation to the preservation standard of pasteurized milk as well as UHT milk to lower than $7^{\circ}C$.

  • PDF

Manufacture of Cutting-Gouda Cheese using Lactobacillus rhamnosus_p1 and the Physicochemical Properties of Gouda Cheese during Ripening Periods (Lactobacillus rhamnosus_p1을 이용한 절단형 고다치즈 제조방법 및 숙성 중 품질특성)

  • Park, Jong-Hyuk;Jung, Hoo-Kil;Moon, Hye-Jung;Oh, Jeon-Hui;Lee, Joo-Hee;Kim, Myung-Kon;Na, Sang-Eon;Kim, Youn-Jeong;Hwang, Young-Tae
    • Journal of Dairy Science and Biotechnology
    • /
    • v.32 no.2
    • /
    • pp.131-139
    • /
    • 2014
  • The aim of this study was to manufacture Cutting-Gouda cheese and to investigate the change in physicochemical properties of Cutting-Gouda cheese made with Lactobacillus rhamnosus_p1. Lactic acid bacteria were isolated from Gouda cheese ripened for more than 1 year. They were identified as 2 strains of L. rhamnosus, Lactobacillus casei, Lactobacillus curvatus, and Staphylococcus saprophyticus by 16S rDNA sequencing and named L. rhamnosus_p1, L. casei_p2, L. curvatus_p3, L. rhamnosus_p4 and S. saprophyticus_p5. The proteolytic activities of isolated strains against casein were measured using prepared skim milk agar plates. L. rhamnosus_p1 showed the highest proteolytic activity. Cutting-Gouda cheese was made with L. rhamnosus_p1, and its physicochemical properties (moisture, protein, fat, ash and free amino acid content) were measured during ripening periods. Because of the modified atmosphere packaging ($N_2{^-}$), there was no change in moisture, protein, fat, and ash in the experimental group. The total amount of free amino acids in the control and experimental group gradually increased during ripening periods. The sensory evaluation showed that the experimental group was preferable to the control group. This result suggests that L. rhamnosus_p1 has potential to be developed as a new starter for Gouda cheese.

  • PDF