• Title/Summary/Keyword: 채널관

Search Result 158, Processing Time 0.027 seconds

A Study on the YouTube Videos Content Characteristics of the National Archives of Korea (국가기록원 유튜브 동영상 콘텐츠 특성에 대한 연구)

  • Ok nam, Park
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.56 no.4
    • /
    • pp.515-536
    • /
    • 2022
  • The purpose of this study is to understand the content characteristics in YouTube videos of the National Archives of Korea. For this purpose, keywords, video data, and viewer responses were collected for 324 videos posted by the National Archives of Korea for five years since April, 2017. Social network analysis, topic modeling, and content analysis were performed. Based on this, the main keywords leading the YouTube videos of the National Archives of Korea, 7 major topics and 20 sub-topics were identified. The characteristics of the YouTube videos and keywords network were studies. In addition, video characteristics were analyzed as external characteristics, video editing and delivery methods, and content characters. The study found that the YouTube channel of the National Archives of Korea has been posting the videos related to various topics such as places, history, and events as well as the basic functions of the archives to induce viewers' interest in the archives. The study also identified the areas that needed to be improved such as low response from viewers, lack of content that could interest viewers, and lack of channel operation to interact or communicate with viewers. Finally, the study was concluded with a proposal to spread the videos of the National Archives of Korea to more users.

Adsorption Characteristics of Hydrogen in Regular Single-Walled Carbon Nanotube Arrays at Low Temperature (저온에서 규칙적인 단일벽 탄소나노튜브 배열의 수소 흡착 특성)

  • Yang Gon Seo
    • Clean Technology
    • /
    • v.29 no.3
    • /
    • pp.217-226
    • /
    • 2023
  • The amount of hydrogen adsorbed in arrays of single walled carbon nanotubes (SWNTs) was studied as a function of nanotube diameter and distance between the nearest-neighbor nanotubes on square arrangements using a grand canonical Monte Carlo simulation. The influence of the geometry of a triangle array with the same diameters and distances was also studied. Hydrogen-carbon and hydrogen-hydrogen interactions were modeled with Lennard-Jones potentials for short range interactions and electrostatic interactions were added for hydrogen-hydrogen pairs to consider quantum contributions at low temperatures. At 194.5 K, Type I isotherms for large-diameter SWNTs and Type IV isotherms without hysteresis between adsorption and desorption processes for wider tube separations were observed. At 200 bars, the gravimetric hydrogen storage capacity of the SWNTs was reached or exceeded the US Department of Energy (DOE) target, but the volumetric capacity was about 70% of the DOE target. At 77 K, a two-step adsorption was observed, corresponding to a monolayer formation step followed by a condensation step. Hydrogen was adsorbed first to the inner surface of the nanotubes, then to the outer surface, intratubular space and the interstitial channels between the nanotube bundles. The simulation indicated that SWNTs of various diameters and distances in a wide range of configurations exceeded the DOE gravimetric and volumetric targets at under 1 bar.

Doses of Coronary Study in 64 Channel Multi-Detector Computed Tomography : Reduced Radiation Dose According to Varity of Examnination Protocols (64 채널 Multi-Detector Computed Tomography를 이용한 관상동맥검사의 선량 : 검사 프로토콜 다변화에 따른 환자선량 감소)

  • Kim, Moon-Chan
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.299-306
    • /
    • 2009
  • Purpose : To compare radiation dose for coronary CT angiography (CTA) obtained with 6 examination protocols such as a retrospectively ECG gated helical scan, a prospectively ECG gated sequential scan, low kVp technique, and cardiac dose modulation technique. Materials and Methods : Coronary CTA was performed by using 6 current clinical protocols to evaluate effective dose and organ dose in primary beam area with anthropomorphic female phantom and glass dosimetric system in 64 channel multi-detector CT. After acquiring topograms of frontal and lateral projection with 80 kVp and 10 mA, main coronary scan was done with 0.35 sec tube rotation time, 40 mm collimation ($0.625\;mm{\times}64\;ea$), small scan field of view (32 cm diameter), 105 mm scan length. Heart beat rate of phantom was maintained 60 bpm in ECG gating. In constant mAs technique 120 kVp, 600 mA was used, and 100 kVp for low kVp technique. In a retrospectively ECG gated helical CT technique 0.22 pitch was used, peak mA (600 mA) was adopted in range of $40{\sim}80%$ of R-R interval and 120mA(80% reduction) in others with cardiac dose modulation. And 210 mAs was used without cardiac dose modulation. In a prospectively ECG gated sequential CT technique data were acquired at 75% R-R interval (middle diastolic phase in cardiac cycle), and 120 msec additional padding of the tube-on time was used. For effective dose calculation region specific conversion factor of dose length product in thorax was used, which was recommended by EUR 16262. Results : The mean effective dose for conventional coronary CTA without cardiac dose modulation in a retrospectively ECG gated helical scan was 17.8 mSv, and mean organ dose of heart was 103.8 mGy. With low kVp and cardiac dose modulation the mean effective dose showed 54.5% reduction, and heart dose showed 52.3% reduction, compared with that of conventional coronary CTA. And at the sequential scan(SnapShot pulse mode) under prospective ECG gating the mean effective dose was 4.9 mSv, this represents an 72.5% reduction compared with that of conventional coronary CTA. And heart dose was 33.8 mGy, this represents 67.4% reduction. In the sequential scan technique under prospective ECG gating with low kVp the mean effective dose was 3.0 mSv, this represents an 83.2% reduction compared with that of conventional coronary CTA. And heart dose was 17.7 mGy, this represents an 82.9% reduction. Conclusion : In coronary CTA at retrospectively ECG gated helical scan, cardiac dose modulation technique using low kVp reduced dose to 50% above compared with the conventional helical scan. And the prospectively ECG gated sequential scan offers substantially reduced dose compared with the traditional retrospectively ECG gated helical scan.

  • PDF

Radio location algorithm in microcellular wide-band CDMA environment (마이크로 셀룰라 Wide-band CDMA 환경에서의 위치 추정 알고리즘)

  • Chang, Jin-Weon;Han, Il;Sung, Dan-Keun;Shin, Bung-Chul;Hong, Een-Kee
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.8
    • /
    • pp.2052-2063
    • /
    • 1998
  • Various full-scale radio location systems have been developed since ground-based radio navigation systems appeared during World War II, and more recently global positioning systems (GPS) have been widely used as a representative location system. In addition, radio location systems based on cellular systems are intensively being studied as cellular services become more and more popular. However, these studies have been focused mainly on macrocellular systems of which based stations are mutually synchronized. There has been no study about systems of which based stations are asynchronous. In this paper, we proposed two radio location algorithms in microcellular CDMA systems of which base stations are asychronous. The one is to estimate the position of a personal station at the center of rectangular shaped area which approximates the realistic common area. The other, as a method based on road map, is to first find candidate positions, the centers of roads pseudo-range-distant from the base station which the personal station belongs to and then is to estimate the position by monitoring the pilot signal strengths of neighboring base stations. We compare these two algorithms with three wide-spread algorithms through computer simulations and investigate interference effect on measuring pseudo ranges. The proposed algorithms require no recursive calculations and yield smaller position error than the existing algorithms because of less affection of non-line-of-signt propagation in microcellular environments.

  • PDF

Added Value of 3D Cardiac SPECT/CTA Fusion Imaging in Patients with Reversible Perfusion Defect on Myocardial Perfusion SPECT (심근관류 SPECT에서 가역적인 병변을 보인 환자의 3차원 심장 SPECT/CTA 퓨전영상의 유용성)

  • Kong, Eun-Jung;Cho, Ihn-Ho;Kang, Won-Jun;Kim, Seong-Min;Won, Kyoung-Sook;Lim, Seok-Tae;Hwang, Kyung-Hoon;Lee, Byeong-Il;Bom, Hee-Seung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.6
    • /
    • pp.513-518
    • /
    • 2009
  • Purpose: Integration of the functional information of myocardial perfusion SPECT (MPS) and the morphoanatomical information of coronary CT angiography (CTA) may provide useful additional diagnostic information of the spatial relationship between perfusion defects and coronary stenosis. We studied to know the added value of three dimensional cardiac SPECT/CTA fusion imaging (fusion image) by comparing between fusion image and MPS. Materials and Methods: Forty-eight patients (M:F=26:22, Age: $63.3{\pm}10.4$ years) with a reversible perfusion defect on MPS (adenosine stress/rest SPECT with Tc-99m sestamibi or tetrofosmin) and CTA were included. Fusion images were molded and compared with the findings from the MPS. Invasive coronary angiography served as a reference standard for fusion image and MPS. Results: Total 144 coronary arteries in 48 patients were analyzed; Fusion image yielded the sensitivity, specificity, negative and positive predictive value for the detection of hemodynamically significant stenosis per coronary artery 82.5%, 79.3%, 76.7% and 84.6%, respectively. Respective values for the MPS were 68.8%, 70.7%, 62.1% and 76.4%. And fusion image also could detect more multi-vessel disease. Conclusion: Fused three dimensional volume-rendered SPECT/CTA imaging provides intuitive convincing information about hemodynamic relevant lesion and could improved diagnostic accuracy.

Mammalian Reproduction and Pheromones (포유동물의 생식과 페로몬)

  • Lee, Sung-Ho
    • Development and Reproduction
    • /
    • v.10 no.3
    • /
    • pp.159-168
    • /
    • 2006
  • Rodents and many other mammals have two chemosensory systems that mediate responses to pheromones, the main and accessory olfactory system, MOS and AOS, respectively. The chemosensory neurons associated with the MOS are located in the main olfactory epithelium, while those associated with the AOS are located in the vomeronasal organ(VNO). Pheromonal odorants access the lumen of the VNO via canals in the roof of the mouth, and are largely thought to be nonvolatile. The main pheromone receptor proteins consist of two superfamilies, V1Rs and V2Rs, that are structurally distinct and unrelated to the olfactory receptors expressed in the main olfactory epithelium. These two type of receptors are seven transmembrane domain G-protein coupled proteins(V1R with $G_{{\alpha}i2}$, V2R with $G_{0\;{\alpha}}$). V2Rs are co-expressed with nonclassical MHC Ib genes(M10 and other 8 M1 family proteins). Other important molecular component of VNO neuron is a TrpC2, a cation channel protein of transient receptor potential(TRP) family and thought to have a crucial role in signal transduction. There are four types of pheromones in mammalian chemical communication - primers, signalers, modulators and releasers. Responses to these chemosignals can vary substantially within and between individuals. This variability can stem from the modulating effects of steroid hormones and/or non-steroid factors such as neurotransmitters on olfactory processing. Such modulation frequently augments or facilitates the effects that prevailing social and environmental conditions have on the reproductive axis. The best example is the pregnancy block effect(Bruce effect), caused by testosterone-dependent major urinary proteins(MUPs) in male mouse urine. Intriguingly, mouse GnRH neurons receive pheromone signals from both odor and pheromone relays in the brain and may also receive common odor signals. Though it is quite controversial, recent studies reveal a complex interplay between reproduction and other functions in which GnRH neurons appear to integrate information from multiple sources and modulate a variety of brain functions.

  • PDF

Fermented Jeju Soybean Extract Promotes Hair Growth in Human Hair Follicle Organ Culture and Clinical Trial (모낭기관배양과 임상에서 제주푸른콩발효추출물의 육모 효능에 미치는 영향)

  • Lee, Yonghee;Shin, Seung Hyun;Kim, Sehyun;Jeong, Gyusang;Hong, Min Jung;Park, Hyeokgon;Kim, Seung Hun;Kim, Eun Joo;Kang, Young-Gyu;Park, Byung Cheol;Park, Won Seok;Kim, Su Na;Kim, Hyoung-June
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.47 no.3
    • /
    • pp.255-263
    • /
    • 2021
  • Soybean extract is known to play an important role in preventing and treating diseases associated with aging, cancer, obesity, and cardiovascular disease. A recent has revealed that soybean extract has a potent effect on hair growth in in vitro, in vivo, and clinical studies. Recently, it has been reported that their fermented extracts exhibit numerous and high efficacy, as compared to general extracts. However, the underlying mechanisms that induce hair growth after using fermented soybean extract are not well understood. The present study aimed to determine the effects of fermented Jeju soybean (FJS) extract on hair growth, with a focus on the underlying mechanisms similar to those of minoxidil. We conducted in vitro and ex vivo investigations and clinical studies. FJS extract enhanced dermal papilla cell proliferation, VEGF levels, and potassium channel opening. Moreover, it promoted human hair follicle elongation. These effects were comprehensively demonstrated in the clinical results, in which FJS extract-containing shampoo improved hair density after 24 weeks of utilization. Collectively, the results of this study demonstrate that FJS extract promotes hair growth and inhibits hair loss through a mechanism similar to that of minoxidil in hair follicles.

An Exploratory Study on Consumer Behavior of Digital Banking Deposits: Focusing on Bank Loyal Customers (디지털 뱅킹 정기예금의 소비자 행동 실태에 관한 탐색적 연구 -은행 충성고객을 중심으로-)

  • Inkwan Cho;Soo Kyung Park;Bong Gyou Lee
    • Journal of Service Research and Studies
    • /
    • v.13 no.2
    • /
    • pp.130-145
    • /
    • 2023
  • The digital transformation of finance is accelerating, and digital banking has already become a major banking channel. Banks have traditionally placed importance on CRM(Customer Relationship Management) and have tried to retain their loyal customers, who contribute significantly to the bank, such as long-term transactions, holding accounts with a certain balance or more, and holding loans. In this situation, this study exploratorily analyzed the consumer behavior of digital banking deposits in a major bank of Korea(1,145 samples). Statistical analysis was performed using SPSS. The main findings of the study are summarized as follows. It was found that there were differences of consumer behavior in digital banking deposits by generation, and the MZ generation used digital banking more on holidays than other generations. As a result of analyzing the behavior of existing loyal customers and regular customers of digital banking deposit, there was a significant difference in both the amount and period of the deposit. It was confirmed that the existing loyal customers of the bank also engage in consumer behavior that contributes to the bank in digital banking. In addition, the interaction between the customer type and the date of sign up for the deposit period, which is the goal setting of financial consumers, it was found that there was a significant effect. This study empirically analyzed the consumer behavior of digital banking in a situation where decrease of bank branches and encounters with digital banking. The major concepts of the consumer behavior theory are Loyal Customer, Goal Pursuit, and Habit, which were confirmed in an example of digital banking. The results of this study can suggest practical implications for existing banks and Internet-only banks, including the importance of customer management in digital banking.