• Title/Summary/Keyword: 채광방식

Search Result 37, Processing Time 0.029 seconds

Development of Solar Daylighting System Using Parabolic Mirrors (포물면 집광거울 방식의 태양광 집광채광시스템 개발)

  • Sung, Tae-Kyung;Lee, Chung-Sik;Kim, Jong-Min;Joung, Che-Bong;Kim, Byung-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.5
    • /
    • pp.240-245
    • /
    • 2013
  • We developed a parabolic reflector based daylighting system which can be used as an alternative indoor daytime lighting device such as for fluorescent lamps. The system comprises three main components : a daylight concentrator made of 4 pairs of parabolic reflectors and mirrors, a silica optical fiber bundle based light transmitter, and 4 light diffusers for the final indoor delivery of the collected daylight. We analyzed the performance of the system and revealed the system efficiency and daylighting factor. All test methods follow the rule, NR PV601 : 2007-daylighting system, governed by Korea Energy Management Corporation.

Un-Cooled High Efficient Solar Lighting System and its Application (비냉각형 고효율 태양광 채광시스템 및 응용에 관한 연구)

  • Lee, Hoe-Youl;Kim, Myoung-Jin;Shin, Seo-Yong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.11B
    • /
    • pp.1394-1402
    • /
    • 2011
  • This paper describes solar light collecting system which employs parabolic reflector and Fresnel lens and its industrial application. We have introduced second-stage optical system so that it makes optical fiber overcome its numerical aperture limitation and also it makes focused light become collimated, which results in decreased light energy density. As result of these, light collecting efficiency become maximized and the system does not require separate cooling apparatus any more. The developed solar lighting system together with artificial light source like LED has been applied to plant factory as a hybrid lighting source. This makes us save electric energy for artificial lighting during day time. The intensity of LED light in the hybrid lighting system is controlled automatically according to ambient-light-sensor installed in the system so that the light intensity for a plant always keeps the same level no matter how the sun light changes. For a plant factory whose size is 330 square meters, when solar lighting system is applied, 28,080KWh electric energy can be saved per month.2 times.

A Study on the Distributional Characteristics of Unminable Manganese Nodule Area from the Investigation of Seafloor Photographs (해저면 영상 관찰을 통한 망간단괴 채광 장애지역 분포 특성 연구)

  • Kim, Hyun-Sub;Jung, Mee-Sook;Park, Cheong-Kee;Ko, Young-Tak
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.3
    • /
    • pp.173-182
    • /
    • 2007
  • It is well known that manganese nodules enriched with valuable metals are abundantly distributed in the abyssal plain area in the Clarion-Clipperton (C-C) fracture zone of the northeast Pacific. Previous studies using deep-sea camera (DSC) system reported different observations about the relation of seafloor topographic change and nodule abundance, and they were sometimes contradictory. Moreover, proper foundation on the estimation of DSC underwater position, was not introduced clearly. The variability of the mining condition of manganese nodule according to seafloor topography was examined in the Korea Deep Ocean Study (KODOS) area, located in the C-C zone. In this paper, it is suggested that the utilization of deep towing system such as DSC is very useful approach to whom are interested in analysing the distributional characteristics of manganese nodule filed and in selecting promising minable area. To this purpose, nodule abundance and detailed bathymetry were acquired using deep-sea camera system and multi-beam echo sounder, respectively on the seamount free abyssal hill area of southern part ($132^{\circ}10'W$, $9^{\circ}45'N$) in KODOS regime. Some reasonable assumptions were introduced to enhance the accuracy of estimated DSC sampling position. The accuracy in the result of estimated underwater position was verified indirectly through the comparison of measured abundances on the crossing point of neighboring DSC tracks. From the recorded seafloor images, not only nodules and sediments but cracks and cliffs could be also found frequently. The positions of these probable unminable area were calculated by use of the recorded time being encountered with them from the seafloor images of DSC. The results suggest that the unminable areas are mostly distributed on the slope sides and hill tops, where nodule collector can not travel over.

A Study on the Computer Simulation Estimate of Light Shelf Using Lightscape (Lightscape를 이용한 광선반의 시뮬레이션 평가 연구)

  • Cho, Yil-Sik;Kim, Ki-Se;Yoon, Jong-Ho;Lee, Jin-Sook
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.3
    • /
    • pp.93-102
    • /
    • 2003
  • One of the promising optical daylighting systems is light shelf type daylighting system, Two types of lighting performance analysis methods are 1) Ray-Tracing method and 2) Radiosity method. The purpose of this paper is to compare two methods in terms of advantages and disadvantages by further looking at the detail algorithm. Also. model verification with Lightscape simulations has been conducted. Effectiveness of light penetration factor in terms of daylighting factor has been investigated and quantified. In summer time. the performance of the light shelf was twice better than the case without it.

A Study on the Supply obligations allotment rate of New Renewable Energy in Indoor Gymnasiums with the Application of a Daylighting System (집광채광시스템을 적용한 실내체육관의 신재생에너지 공급의무 분담률에 관한 연구)

  • Park, Yun-Ha;Lee, Yong-Ho;Cho, Young-Hum;Hwang, Jung-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.3
    • /
    • pp.27-39
    • /
    • 2015
  • Under the goal of analyzing the compulsory supply share of new renewable energy according to the application of a daylighting system to indoor gymnasiums, this study conducted analysis of energy consumption and operation schedule at three indoor gymnasiums in the nation through a survey. The investigator did an Energy Plus simulation on Building A based on the analysis results and analyzed the supply share of new renewable energy in the saving effects of lighting energy according to the application of a daylighting system. As a result, When 92 prism daylighting system were installed in the upper ceiling of a stadium, they were able to meet the criteria for the minimum illumination for official games(Min : 600㏓) and optimum illumination for general games and recreations, thus saving lighting energy during the daytime(09:00~17:00). The resulting saving effects of lighting energy amounted to 44.4% for official games, 57.6% for general games, and 66.7% for recreations. In addition, the daylighting systems had a compulsory supply share of new renewable energy at 2.04% for official games, 2.75% for general games, and 2.62% for recreations, recording an average compulsory supply share of 2.5%.

A Study on Visual Comfort for Compound Lighting Control Method of Applied Daylighting (자연채광의 응용에 의한 합성조명방식의 시각적 쾌적성에 관한 연구)

  • Han, Sang-Pil;Jeon, Yong-Han;Han, Sang-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.spc3
    • /
    • pp.199-206
    • /
    • 2012
  • The purpose of this study is to understand the change of impression by comparing the uniformity lighting with the compound lighting. In previous study, we proposed a light controlling method to harmonize daylight from a window and artificial lights from a ceiling and obtained the results to support our method. We referred this method as the Adjusted Compound-Lighting Model (AC Model). The experiment is carried out with the scaled-models and mock-up spaces that were supposed to be an office space. One is lit by the uniform lighting and the other by the compound lighting in each experimental space. In order to present varying illuminance distributions, the two variables were used in this study. Subjects were asked to evaluate the point of difference by semantic differential rating on their overall impression after comparing with two rooms. The results showed that the impressions of compound lighting were more positive score than that of uniformity lighting on the items of 'dim-bright', 'dislike-like', 'artificial-natural' and 'closed-open', and that there was no significant difference in impressions between two spaces on other items.

Measures to Reduce Mine Hazards Caused by Open- cut Mining of Limestone Mines (석회석광산에서 노천채굴에 따른 광해 발생을 감소시키기 위한 대책)

  • Won, Yeon-Ho;Ah, Jin-Man
    • Explosives and Blasting
    • /
    • v.24 no.2
    • /
    • pp.75-82
    • /
    • 2006
  • Most of limestone mines in Korea have been developed by a open-cut mining method in consideration of a deposited condition of ore, ore recovery, safety, economic efficiency, etc.. But it has produced environmental problems such as dust flying, blasting noise & vibration, and spoil of farmlands due to slope failure of waste rock mass caused by access road construction, fragmentation & crush of rocks, blasting, transportation, and mineral processing. In this study, it has been suggested for measures to reduce mine hazards caused by open- cut mining of limestone nines.

The Issue of Modern Dwelling in Sinhaksinseol(新學新說: New Knowledge New Theory) by Ji, Syok-young (지석영의 "신학신설" (1891)에서 근대적 주거 문제)

  • Kim, Myung-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.3
    • /
    • pp.765-770
    • /
    • 2008
  • Ji, Syok-young wrote a book named Sinhaksinseol(新學新說) in 1891, one of the first hygiene books in Korea. There were the conditions of modern housing like lighting, ventilation and dry and fresh air of a housing site in the contents of the book. Because the book was written when the modern hygiene theory had just been accepted, traditional concept of 'Yangseng(養生),' but it dealt the main environmental conditions of hygienic housing at first, which makes it the leader of modern housing discourses through the newspapers, magazines, academic journals or textbooks from 1890s mid to 1910.

A Case study on Storytelling Experiential Exhibition at the National Lighthouse Museum (국립등대박물관 스토리텔링 체험전시 연출 사례연구 -<등대와 과학> 상설전시를 중심으로-)

  • Song-Yi Kim
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2023.11a
    • /
    • pp.162-165
    • /
    • 2023
  • This paper examines the approaches to science operational exhibitions and storytelling to enhancing visitors of the National Lighthouse Museum of Korea. Through this case, our museum aims to share its directions of the scientific exhibition and development direction of the Aids to Navigation Heritage Museum. The exhibition content was storytelling to naturally guide the flow along the story, and the exhibition coordinating was designed as an experiential exhibition so that visitors could interestingly experience the scientific principles applied to navigation signs.

  • PDF

A study on drainage system of the room-and-pillar underground structure considering groundwater conditions (지하수 유출수 조건을 고려한 주방식 지하구조의 배수시스템 연구)

  • Lee, Chulho;Hyun, Younghwan;Hwang, Jedon;Chang, Soo-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.6
    • /
    • pp.675-683
    • /
    • 2015
  • The room-and-pillar construction method for underground space is adopted from the room-and-pillar mining method which is one of the most popular underground mining method in the world. Drainage system in the room-and-pillar underground construction method can be similar with the concept of single shell in tunnel because additional reinforcement except the TSL (thin spray-on liner) is not applied in the room-and-pillar construction method. That is, to decrease groundwater level and maintain safety in tunnel, the drainage pin hole inside lining (shotcrete) can be used. However, if total amount of outflow in the underground structure is relatively small or groundwater is not detected, such drainage system will not be useful and cause additional construction cost. In this study, outflow of conventional tunnels in South Korea was investigated and the criteria to determine whether the drainage pin hole is effective was suggested. And the guided drainage system was suggested when drainage pin hole was not applied in the room-and-pillar construction method.