• Title/Summary/Keyword: 참조온도

Search Result 52, Processing Time 0.023 seconds

Effects of Plant Growth Regulators for Hard Wood and Cutting Time for Soft Wood on Rooting of Korean Native Spiraea spp. (숙지의 생장조절제 처리 및 녹지의 삽목시기가 한국 자생 조팝나무류의 발근에 미치는 영향)

  • Lee, Jeong Ho;Song, Cheon Young;Woo, Hyo Jin;Kwon, Oh Woung
    • FLOWER RESEARCH JOURNAL
    • /
    • v.19 no.2
    • /
    • pp.103-109
    • /
    • 2011
  • This study was conducted to develop mass production method by proper cutting time, and the concentrations of plant growth regulators of Spiraea spp. Plants of hard wood was cut on March 3th, the rooting rate in S. salicifolia and S. cantoniensis was 11.3% comparatively higher than that about 5% in S. trichocarpa, S. miyabei, S. japonica, S. thunbergii and S. fritschiana. The rooting of control was 6.0%, however the $125{\sim}1,000mg{\cdot}L^{-1}$ IBA or NAA for 3 hour soaking was above 15.0% in the S. salicifolia. Therefore soaking in $125mg{\cdot}L^{-1}$ of IBA or NAA solution was recommended before cutting. The proper cutting time for soft wood from May 7 to September 17 in S. trichocarpa, S. cantoniensis, S. prunifolia, and S. thunbergii was September 17 when the soft stem was changed hard and the temperate was proper for rooting, high and low, $25{\pm}3^{\circ}C$ and $18{\pm}3^{\circ}C$. The rooting of September 17 was above 70% in S. salicifolia and S. fritschiana. However, the rooting from middle of May to early August was low below 20% in all the genus of Spiraea.

A Study on the Dynamic Charateristics for Control of Gas-Fueled industrial Gas Boiler(I) (산業용 GAS 보일러의 動特性에 관한 硏究 (I))

  • 임종한;이종원
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.5
    • /
    • pp.965-973
    • /
    • 1992
  • Boilers, which are considered to be one of the basic equipment in industry, consume large potion of nation's petroleum and their demand is growing everyday. In recent, the technology improvement in production of high efficiency boilers and their effective utilization is needed for design of boiler which steam condition is the large capacity of high temperature and high pressure. It is necessary that boiler control system be studied for high efficiency, high reliability and smooth operation. The control of drum pressure and water level particularly becomes an important task for greater accuracy with the avail ability of boiler operation. To achieve this aim, dynamic analysis of a boiler is accomplished by choosing a boiler as a model. Transfer function thus obtained is made a comparison of measurement with reckoning to technical design data. The results of comparison makes it possible to verify thermodynamical analysis on the dynamic behavior of the overall system.

Time Resolution Improvement of MRI Temperature Monitoring Using Keyhole Method (Keyhole 방법을 이용한 MR 온도감시영상의 시간해상도 향상기법)

  • Han, Yong-Hee;Kim, Tae-Hyung;Chun, Song-I;Kim, Dong-Hyeuk;Lee, Kwang-Sig;Eun, Choong-Ki;Jun, Jae-Ryang;Mun, Chi-Woong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.31-39
    • /
    • 2009
  • Purpose : This study proposes the keyhole method in order to improve the time resolution of the proton resonance frequency(PRF) MR temperature monitoring technique. The values of Root Mean Square (RMS) error of measured temperature value and Signal-to-Noise Ratio(SNR) obtained from the keyhole and full phase encoded temperature images were compared. Materials and Methods : The PRF method combined with GRE sequence was used to get MR temperature images using a clinical 1.5T MR scanner. It was conducted on the tissue-mimic 2% agarose gel phantom and swine's hock tissue. A MR compatible coaxial slot antenna driven by microwave power generator at 2.45GHz was used to heat the object in the magnetic bore for 5 minutes followed by a sequential acquisition of MR raw data during 10 minutes of cooling period. The acquired raw data were transferred to PC after then the keyhole images were reconstructed by taking the central part of K-space data with 128, 64, 32 and 16 phase encoding lines while the remaining peripheral parts were taken from the 1st reference raw data. The RMS errors were compared with the 256 full encoded self-reference temperature image while the SNR values were compared with the zero filling images. Results : As phase encoding number at the center part on the keyhole temperature images decreased to 128, 64, 32 and 16, the RMS errors of the measured temperature increased to 0.538, 0.712, 0.768 and 0.845$^{\circ}C$, meanwhile SNR values were maintained as the phase encoding number of keyhole part is reduced. Conclusion : This study shows that the keyhole technique is successfully applied to temperature monitoring procedure to increases the temporal resolution by standardizing the matrix size, thus maintained the SNR values. In future, it is expected to implement the MR real time thermal imaging using keyhole method which is able to reduce the scan time with minimal thermal variations.

  • PDF

Study on Operating Limits of 5.56mm Rifle Overheat - Focusing on Human Engineering (5.56mm 소총 과열에 의한 운용한계 분석 - 인간공학 중심으로)

  • Lee, Ho-Jun;Choi, Si-Young;Shin, Tae-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.9
    • /
    • pp.49-56
    • /
    • 2020
  • High temperature heat generated during rifle firing not only degrades the performance of the weapon, but also limits the user's operation. In this study, temperature change of handguard according to firing was measured with reference to Human Engineering criteria and the operability according to material was examined. Accordingly, for the firing test, three types of Korean rifle and one overseas model were selected for each material of handguard, and firing test was conducted using a contact type temperature meter. The test result shows that using a plastic handguard with low thermal conductivity and aluminum handguard with high thermal conductivity enabled the rifles to be operated with bare hands even when firing at more than 100 rounds at low atmospheric temperature. However, when firing more than 60 rounds at over 20℃ atmospheric temperature, aluminum handguard use is limited. When firing quickly over 100 rounds, handguard use is restricted regardless of its fabrication material. To eliminate operational limitations by overheating, it is necessary to eliminate direct contact with skin using gloves, vertical grips, etc. This study examined the operability of rifles in terms of thermal risk, and the resulting study results are expected to be used as basic data for Human Engineering of other rifles and munitions.

Magnetic Properties of Electroless Co-Mn-P Alloy Deposits (무전해 Co-Mn-P 합금 도금층의 자기적 특성)

  • Yun, Seong-Ryeol;Han, Seung-Hui;Kim, Chang-Uk
    • Korean Journal of Materials Research
    • /
    • v.9 no.3
    • /
    • pp.274-281
    • /
    • 1999
  • Usually sputtering and electroless plating methods were used for manufacturing metal-alloy thin film magnetic memory devices. Since electroless plating method has many merits in mass production and product variety com­pared to sputtering method, many researches about electroless plating have been performed in the United State of America and Japan. However, electroless plating method has not been studied frequently in Korea. In these respects the purpose of this research is manufacturing Co-Mn-P alloy thin film on the corning glass 2948 by electroless plating method using sodium hypophosphite as a reductant, and analyzing deposition rate, alloy composition, microstructure, and magnetic characteristics at various pH's and temperatures. For Co-P alloy thin film, the reductive deposition reaction 0$\alpha$urred only in basic condition, not in acidic condition. The deposition rate increased as the pH and temperature increased, and the optimum condition was found at the pH of 10 and the temperature of $80^{\circ}C$. Also magnetic charac­teristics was found to be most excellent at the pH of 9 and the temperature of $70^{\circ}C$, resulting in the coercive force of 8700e and the squareness of 0.78. At this condition, the contents of P was 2.54% and the thickness of the film was $0.216\mu\textrm{m}$. For crystal orientation, we could not observe fcc for $\beta$-Co. On the other hand,(1010), (0002), (1011) orientation of hcp for a-Co was observed. We could confirm the formation of longitudinal magnetization from dominant (1010) and (1011) orientation of Co-P alloy. For Co-Mn-P alloy deposition, coercive force was about 1000e more than that of Co P alloy, but squareness had no difference. For crystal orientation, (l01O) and (lOll) orientation of $\alpha$-Co was dominant as same as that of Co- P alloy. Likewise we could confirm the formation of longitudinal magnetization.

  • PDF

Fixed Pattern Noise Reduction in Infrared Videos Based on Joint Correction of Gain and Offset (적외선 비디오에서 Gain과 Offset 결합 보정을 통한 고정패턴잡음 제거기법)

  • Kim, Seong-Min;Bae, Yoon-Sung;Jang, Jae-Ho;Ra, Jong-Beom
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.49 no.2
    • /
    • pp.35-44
    • /
    • 2012
  • Most recent infrared (IR) sensors have a focal-plane array (FPA) structure. Spatial non-uniformity of a FPA structure, however, introduces unwanted fixed pattern noise (FPN) to images. This non-uniformity correction (NUC) of a FPA can be categorized into target-based and scene-based approaches. In a target-based approach, FPN can be separated by using a uniform target such as a black body. Since the detector response randomly drifts along the time axis, however, several scene-based algorithms on the basis of a video sequence have been proposed. Among those algorithms, the state-of-the-art one based on Kalman filter uses one-directional warping for motion compensation and only compensates for offset non-uniformity of IR camera detectors. The system model using one-directional warping cannot correct the boundary region where a new scene is being introduced in the next video frame. Furthermore, offset-only correction approaches may not completely remove the FPN in images if it is considerably affected by gain non-uniformity. Therefore, for FPN reduction in IR videos, we propose a joint correction algorithm of gain and offset based on bi-directional warping. Experiment results using simulated and real IR videos show that the proposed scheme can provide better performance compared with the state-of-the art in FPN reduction.

Development of Multi-Touch/Context-Aware Convergence Digital Signage System based on Android OS Platform (안드로이드 플랫폼 기반 멀티 터치/상황인지형 융복합 디지털 사이니지 시스템 개발)

  • Nahm, Eui-Seok
    • Journal of Digital Convergence
    • /
    • v.13 no.8
    • /
    • pp.245-251
    • /
    • 2015
  • If a digital signage system is operated in PC mounted in the Window OS then the implementing price is very high. For resolving this problem, we used the Smartphone mounted in ARM Cortex family of multi-core processor-based mobile platform. We developed a low-power low-cost digital signage system and a remote convergence content management program based on web server. This convergence system manages advertising content to a remote control device anywhere using remote control technology. This system is one integrated system with display and is a low-power consumed and is developed in very efficient hardware interface. And condition sensors(intensity of illumination, temperature, weather, GPS etc) is equipped in the developed system. Automatic contents builder and Context-aware SMIL module is also implemented in the convergence system. We achieved over 50% power savings comparing with conventional Window OS system and 16 points multi-touch in our system.

Effect of Heat Transfer and Phase Change of Coolant on the Performance of Mixed-gas Ejection System (냉각제의 분사조건 및 상변화가 혼합가스 사출시스템의 성능에 미치는 영향)

  • Kim, Hyun Muk;Kim, Jeong Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.6
    • /
    • pp.84-93
    • /
    • 2018
  • Three-dimensional (3D) numerical simulations have been carried out to study how coolant injection conditions influence the cooling efficiency and projectile ejection performance in a mixture-gas ejection system (or gas-steam launch system). The 3D single-phase computational model was verified using a 1D model constructed with reference to the previous research and then a two-phase flow computation simulating coolant injection on to hot gas was performed using a DPM (Discrete Phase Model). As a result of varying the coolant flow rate and number of injection holes, cooling efficiency was improved when the number of injection holes were increased. In addition, the change of the coalescence frequency and spatial distribution of coolant droplets caused by the injection condition variation resulted in a change of the droplet diameter, affecting the evaporation rate of coolant. The evaporation was found to be a critical factor in the design optimization of the ejection system by suppressing the pressure drop while the temperature decreases inside the breech.

Examinations of Morphology and Residual Water Quality Parameters on Saemangeum Basin under Gate Operations with SCHISM-CoSiNE (배수갑문 운영에 따른 새만금 호내의 지형 및 잔존 수질인자변화 검토: SCHISM-CoSiNE 모형 적용)

  • Yoo, Hyung Ju;Kim, Dong Hyun;Bang, Young Jun;Lee, Seung Oh
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.84-84
    • /
    • 2020
  • 새만금은 농업용지 확보 등 다양한 용도의 토지이용을 목적으로 방조제 공사를 수행하였으며, 새만금 종합개발계획(Master Plan, OPC, 2011)에 의하여 호내의 준설을 계획하고 있다. 그러나 방조제 준공 후 새만금 호내의 수질오염 문제가 지속적으로 발생되어 왔다. 수질오염의 문제를 해결하기위해서 강변저류지 설치, 하수종말 처리장 등 다양한 구조적 대책이 수립되고 시행되었지만, 수질개선 효과는 상대적으로 미비하였다(Kim et al, 2016; KRCC, 2016). 본 연구에서는 새만금 호내의 수질개선을 위하여, 다양한 배수갑문 운영에 따른 수질인자의 잔존률 및 하상의 변화를 SCHISM-CoSiNE(Semi-implicit Cross-scale Hydroscience Integrated System Model and Carbon, Silicate, Nitrogen Ecosystem model) 모형을 통하여 검토하고자 한다. 수치모형의 하상변동 및 수질변화에 대한 정확한 수치계산 여부를 판단하기 위하여 van Rijn(1987) 실험 및 새만금호내의 수질 관측자료(DO, T-N, T-P, 온도, 염도, 새만금유역 통합환경관리시스템)를 이용하여 수치모형 검증을 수행하였고 10% 이내의 오차를 나타내었다. 배수갑문 운영기록(Jeong et al., 2018)을 참조하여 배수갑문 운영을 재현하였으며, 지형은 기 수립된 MP 내 새만금 종합개발계획이 완료된 시점인 2030년을 기준으로 하였다. 수치모의를 통하여, 배수갑문 운영 및 계절의 변화에 따른 최심 하상변동고 변화 및 하상변동량을 확인하여 침식 퇴적 구간을 구분하였고, 호내의 잔존하는 수질인자의 농도를 통하여 수질개선 효과를 평가하여 수질측면에서 최적의 배수갑문 운영방안을 제시하였다. 본 연구는 배수갑문 운영이 새만금 호내의 수질 및 지형에 미치는 영향에 대한 기초적인 연구이지만 향후에는 다양한 수질인자 및 시나리오를 고려한다면 보다 근본적인 수질오염 해결방안으로 활용이 가능할 것으로 판단된다.

  • PDF

Repeatability and Reproducibility in Effective Porosity Measurements of Rock Samples (암석시험편 유효공극률 측정의 반복성과 재현성)

  • Lee, Tae Jong;Lee, Sang Kyu
    • Geophysics and Geophysical Exploration
    • /
    • v.15 no.4
    • /
    • pp.209-218
    • /
    • 2012
  • Repeatability and reproducibility in solid weight and effective porosity measurements have been discussed using 8 core samples with different diameters, lengths, rock types, and effective porosities. Further, the effect of temperature on the effective porosity measurement has been discussed as well. Effective porosity of each sample has been measured 7 times with vacuum saturation method with vacuum pressure of 1 torr and vacuum time of 80 minutes. Firstly, effective porosity of each sample is measured one by one, so that it can provide a reference value. Then for reproducibility check, effective porosity measurements with vacuum saturation of 2, 4, and 8 samples simultaneously have been performed. And finally, repeated measurements for 3 times for each sample are made for repeatability check. Average deviation from the reference set in solid weight showed 0.00 $g/cm^3$, which means perfect repeatability and reproducibility. For effective porosity, average deviations are less than 0.07% and 0.05% in repeatability and reproducibility test sets, respectively, which are in good agreement too. Most of porosities measured in reproducibility test lies within the deviation range in repeatability test sets. Thus, simultaneous vacuum saturation of several samples has little impact on the effective porosity measurement when high vacuum pressure of 1 torr is used. Air temperature can cause errors on submerged weight read and even effective porosity, because it is closely related to the temperature, density, and buoyancy of water. Consequently, for accurate measurement of effective porosity in a laboratory, efforts for maintaining air or water temperature constant during the experiment, or a temperature correction from other information are needed.