• Title/Summary/Keyword: 참고 기준치

Search Result 19, Processing Time 0.029 seconds

Reference Levels for Radiation Dose in Angiography and Interventional Radiology : In the Cerebrum (혈관 조영 검사 및 중재적 방사선 시술시 방사선량에 대한 참고 기준치 : 대뇌 중심으로)

  • Han, Jae-Bok
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.3
    • /
    • pp.302-308
    • /
    • 2011
  • The aim of this study is to compare reference levels for radiation dose in angiography and interventional radiology. Proposed reference levels for various procedures and classification of diseases are provided by fluoroscopy time and kerma area product(KAP) rate normalizing the body habitus focusing the cerebrum. Subarachnoid hemorrhage(SAH) represents the highest KAP-rates and aneurysm represents the lowest KAP-rates. According to these types of procedures, internal carotid artery(ICA), common carotid artery(CCA), and vertebral artery(VA) show the highest KAP-rates and guglielmi detachable coil shows the lowest KAP-rates. Therefore, the present study can suggested reference levels for patient radiation dose and is expected to be further useful in the field of radiation dose education and management of angiography and interventional radiology.

Analysis of RF Specification in the ITU-R Recommendations (ITU-R RF 성능 권고(안) 분석)

  • Park, J.A.;Park, S.G.
    • Electronics and Telecommunications Trends
    • /
    • v.23 no.5
    • /
    • pp.131-142
    • /
    • 2008
  • 최근 ITU-R에서는 전파혼신과 밀접한 관계가 있는 무선기기의 RF 항목(주파수허용편차, 점유주파수대역폭, 불요발사 등)에 대한 권고안 SM.1045, SM.328, SM.853, SM.329, SM.1539 등을 제정하거나 개정하였다. 이와 관련하여 본 논문에서는 국내 무선설비규칙의 전파 질 허용치 및 측정방법과 연계하여 ITU-R RF 성능 권고(안)의 핵심내용에 대한 분석결과를 제시하였다. 본 논문의 내용은 무선기기의 인증 및 무선국 검사에 적용되는 국내 무선설비 기술기준치를 이해하는 데 참고자료로 활용될 것으로 기대된다.

Correlation Analysis of between Patient and Equipment Factors and Radiation Dose in Chest Low Dose and Abdominal Non-contrast CT (흉부 저선량 및 복부 비조영 CT 검사에서 환자 및 장비 인자와 선량과의 상관관계 분석)

  • Shim, Jina;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.117-123
    • /
    • 2021
  • This paper is to establish a basis for a dose reduction strategy by confirming correlations with the factors that may affect the radiation dose based on the dose records in low-dose chest CT and abdominal non-contrast CT. In order to find out the causes of unnecessary exposure, the correlation between seven factors (age, gender, height, weight, BMI, patient status [inpatient and outpatient], and use of dose modulation) and CT dose were identified. Logistic regression was used as the statistical analysis for correlation verification. In the low dose chest CT, as the higher values of height and BMI and dose modulation off were associated with lowering the risk exceeding Diagnostic Reference Levels(DRL) (odds ration<1, p<0.05). However, as woman compared to man and the higher values of weight were associated with highering the risk exceeding DRL (odds ration>1, p<0.05). In the abdomen CT, as dose modulation off were associated with lowering the risk exceeding DRL (odds ration<1, p<0.05). Therefore It is necessary to conduct research on the relationship between various factors affecting radiation exposure and patient radiation dose for reducing the dose.

Studies on Circumstances of Agricultural Water Quality (농업용수(農業用水)의 수질환경(水質環境) 조사분석(調査分析))

  • Suh, Seung Duk;Kim, Tae Han;Yoon, Kyung Duk
    • Current Research on Agriculture and Life Sciences
    • /
    • v.1
    • /
    • pp.85-93
    • /
    • 1983
  • Total annual water requirements for agricultural use are exceedingly large. In many areas of the country, particularly in the arid regions, irrigation water requirements comprise the bulk of the total developed water supply. On the other hand, we are, at present, poorly prepared to evaluate the hazards of many substances in the water phase of the agricultural environments. This study is to survey the water quality phase of agricultural conditions and to give some ideas to prevent disasters from the environmental hazards such as PH, Electric Conductivity, BOD, DO, Cu, Pb, and Cd. In the analysed results, mean PH was 6.5 to 7.8, maximum EC was $200{\mu}{\Omega}/cm$ at $25^{\circ}C$, the maximum BOD was less than 10 ppm (standard value), the DO was 4.2 to 12.0 mg/L (standard value is more than 2.0 mg/L) and the Cu, Pb, Cd were estimated in scope of safety value respectively. Especially BOD is gradually closed with the hazardous point in the few places. At present, the hazardous environmental conditions originated from the municipal sewage, industrial waste, and human and domestic animals excrements etc. have to strongly be improved much better than before.

  • PDF

Establishment of Reference Value of Insulin Using the Statistical Analysis (통계적 분석을 통한 Insulin의 정상 참고치 설정)

  • Kim, Whe-Jung;Yoon, Pil-Young;Shin, Young-Goon;Yoo, Seon-Hee;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.143-146
    • /
    • 2010
  • Purpose: Insulin is involved in carbohydrate metabolism and also it's very important because it increases storage of glycogen, synthesis of fatty acids, absorption of amino acid, synthesis of protein. Insulin is clinically useful when we evaluate fasting patients in hypoglycemia, classify and predict diabetes, assess the activity of ${\beta}$-cell, research insulin resistance. We are going to increase usability of insulin assay by establishing normal reference value according to statistical analysis. Material & Method: We selected 6,648 patients who visited asan health medical center from May to August in 2008. We set exclusion criteria as family of diabetes, diabetes medication, the past history of blood glucose rise, more than 100 mg/dL in normal fasting blood glucose, outside the scope of BMI 18.5~22.9 $kg/m^2$, and more than HbA1c 6.5%. We determine whether the subgroup is portioned as sex and age or not and establish normal reference value by conducting statistical analysis as Bayesian's method and Hoffman's method. Result: Portioning of subgroup as sex and age is not needed. By statistical analysis of Bayesian method, results 1.5-11.0 uIU/mL. By statistical analysis of Hoffman method, results 1.8~12.8 uIU/mL. Conclusion: We established 1.8~12.8 uIU/mL as Insulin normal reference value by Hoffman method. This is a similar value with reporting reference value 1.7~11.8 uIU/mL in kit. This will enhance the usability of insulin assay by establishing normal reference value.

  • PDF

Trace element concentrations profiles in the hair of normal children living in the northern area of Seoul (서울 북부지역에 거주하는 정상 아동의 모발 미네랄 함량)

  • Kwon, Ji Won;Kim, Byung Eui;Park, Mi Jung;Kim, Sang Woo
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.1
    • /
    • pp.18-23
    • /
    • 2006
  • Purpose : The reliability of hair mineral analyses regarding nutritional status, environmental exposure or diseases is controversial. The aim of this study was to determine the normal reference range of hair mineral concentration of Korean children. Methods : We examined hair mineral concentrations of 223 children(3-12 yrs old, 110 boys, 113 girls, mean age $8.8{\pm}2.2$ yrs old) living in the northern area of Seoul. The trace elements including six toxic elements(Al, As, Cd, Ba, Hg, Pb) and 11 nutritional elements(Na, Mg, P, K, Ca, Cr, Mn, Fe, Cu, Zn, Se) were analyzed by inductive coupled plasma mass spectrometry(ICP-MS). Results : The mean concentrations of Ca and Mg were higher in girls than in boys. The mean concentrations of Cd, Pb and Cr were higher in boys than girls. The Zn, Ca, Mg, Cu and Hg levels in hair samples were positively correlated with increasing age. The Zn levels of the Korean children's hair samples appear to be lower than that of other countries' reference values. Conclusion : There are considerable differences in hair mineral concentrations by age, sex and race. Additional research is needed to establish Korean reference values, and to evaluate the usefulness of hair mineral analyses as a screening tool for nutrition- and environment-related childhood diseases.

Normative blood pressure references for Korean children and adolescents (한국 소아 청소년 정상 혈압 참고치)

  • Lee, Chong Guk;Moon, Jin Soo;Choi, Joong-Myung;Nam, Chung Mo;Lee, Soon Young;Oh, Kyungwon;Kim, Young Taek
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.1
    • /
    • pp.33-41
    • /
    • 2008
  • Purpose : It is now understood that blood pressure (BP) measurement in the routine pediatric examination is very important because of the relevance of childhood BP to pediatric health care and the development of adult essential hypertension. There hasn't been a reference table of BP for Korean children and adolescents up to now. This study was to make normative BP references and to provide criteria of hypertension for Korean children and adolescents. Methods : BP measurements were done on 57,433 Koean children and adolescents (male: 29,443, female: 27,990), aged 7 to 20 years, in 2005. Heights and weights were measured simultaneously. Oscillometric devices, Dinamap Procare 200 (GE Inc., Milwaukee, Wi, USA), were used for the measurements. BPs were measured 2 times and mean levels were gathered for the analysis. Outliers of 2,373 subjects with overweight per height, over +3SD, were excluded for the analysis. For the BP centiles adjusted by sex, age and height, fixed modified LMS method which was adopted from the mixed effect model of 2004 Task Force in NHLBI (USA) was used. Results : Normative BP tables for Korean children and adolescents adjusted for height percentiles (5th, 10th, 25th, 50th, 75th, 90th, 95th), gender (male, female) and age(7 to 18 years) were completed. Height centiles of Korean children and adolescents are available from Korean Center for Disease Control and Prevention homepage, http://www.cdc.go.kr/webcdc/. Criteria of hypertension (95th, 99th percentile) and normal range of BP (50th, 90th) adjusted for height percentiles, age and gender were made. Conclusion : This is the first study to make normative BP tables and define hypertension for the Korean children and adolescents. Reliability and accuracy of Dinamap Procare 200 oscillometer for BP measurements remains debatable.

Usefulness of Serum Thymidine Kinase 1 as a Biomarker for Aggressive Clinical Behavior in B-cell Lymphoma (B세포림프종의 임상적 악성도 표지자로서 혈청 Thymidine Kinase 1의 유용성)

  • Kim, Heyjin;Kang, Hye Jin;Lee, Jin Kyung;Hong, Young Jun;Hong, Seok-Il;Chang, Yoon Hwan
    • Laboratory Medicine Online
    • /
    • v.6 no.1
    • /
    • pp.25-30
    • /
    • 2016
  • Background: The cell cycle-dependent enzyme thymidine kinase 1 (TK1) is known to increase during cancer cell proliferation and has been reported as a prognostic marker for various hematologic malignancies and solid tumors. This study aimed to determine the reference interval in Korean healthy controls and to evaluate the usefulness of TK1 as a biomarker for aggressive clinical behavior in B-cell lymphoma patients. Methods: We enrolled 72 previously untreated patients with B-cell lymphoma and 143 healthy controls. Serum TK1 levels were measured by chemiluminescence immunoassay ($Liaison^{(R)}$, DiaSorin, USA). We established the reference intervals in healthy controls. The diagnostic performance of serum TK1 was studied using receiver operating characteristic (ROC) analysis, and the correlation between the cutoff level for serum TK1 and clinical characteristics of B-cell lymphoma was evaluated. Results: The reference range (95th percentile) of serum TK1 in healthy controls was 5.4-21.8 U/L. There was a clear difference in TK1 levels between patients with B-cell lymphoma and healthy controls ($40.6{\pm}68.5$ vs. $11.8{\pm}4.4U/L$, P <0.001). The area under the curve of serum TK1 for the diagnosis of B-cell lymphoma was 0.73 (cutoff, 15.2 U/L; sensitivity, 59.7%; specificity, 83.2%). An increased TK1 level (${\geq}15.2U/L$) correlated with the advanced clinical stage (P <0.001), bone marrow involvement (P =0.013), international prognostic index score (P =0.001), lactate dehydrogenase level (P =0.001), low Hb level (<12 g/dL) (P =0.028), and lymphocyte count (P =0.023). Conclusions: The serum TK1 level could serve as a useful biomarker for aggressive clinical behavior in B-cell lymphoma patients.

Quantitative Analysis of Glottal Cycles According to Frequency and Intensity Variations in Normal Speakers (발성의 강도와 주파수 변화에 따른 성대 움직임의 정량적 분석)

  • Young-Ik Son;Kyungah Lee;Jun-Sun Ryu;Chung-Hwan Baek
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.8 no.1
    • /
    • pp.5-11
    • /
    • 1997
  • To set up an objective basis for the evaluation of the stroboscopic findings, video-strobolaryngoscopic images of vocal fold vibration in 5 female and 5 male normal speakers were analyzed using an image analysis computer program called KSIP(Kay Storoboscopy Image Processing, Kay Elemetrics Corp., NJ, USA). Four consecutive vibratory cycles were compared in comfortable, louder, high-pitched /ee/ phonation for every subject. findings mostly replicated earlier studies including glottal chinks which were observed in most female speakers throughout the cycles and clear distinction between female and male speakers in their vibratory patterns as well as intensity and frequency-re-lated differences. However, there were some findings incompatible with those from previous studies which may be attributable to technical problems. This study may provide an objective basis of the stroboscopic findings such as image shape, amplitude, area, and their changes according to frequency and intensity variations. We anticipate that funker study with larger samples ran provide an objective criteria for normal vibratory characteristics of the laryngostro-boscopic findings.

  • PDF

Derivation of Intervention levels for Protection of the Public in a Radiological Emergency in Korea (주민보호조치를 위한 국내 방사선비상 개입준위 산출)

  • Lee, Jong-Tai;Lee, Goan-Yup;Khang, Byung-Oui;Oh, Ki-Hoon;Kim, Chang-Kyu
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.4
    • /
    • pp.357-365
    • /
    • 2001
  • Intervention levels for protection of the public in a radiological emergency are theoretically derived by the cost-benefit approach with the concept of justification and optimization. Intervention levels on the sheltering, evacuation, temporary relocation and permanent resettlement for protection of the public are estimated with the cost to protective countermeasures and the value from dose averted which are the site specific parameters. As a result, it is confirmed that IAEA guidelines for intervention levels are applicable to the radiological emergency in Korea. Optimum ranges of 5 - 10 mSv/2days for sheltering, 25 - 130 mSv/week for evacuation, 15 - 90 mSv/month lot temporary relocation and 600 - 3,500 mSv/lifetime for permanent resettlement for intervention levels are also provided. The result can be applied as useful data to update intervention levels under the theoretical background in Korea.

  • PDF