• Title/Summary/Keyword: 착용 실험

Search Result 398, Processing Time 0.023 seconds

Development of the Pushing Type Cutting Device to Dismantle Concrete Structure for Decommissioning of Nuclear Power Plant (원전해체 시 콘크리트 구조물 절단을 위한 밀기형 절단장치 개발)

  • Lee, Bong-Jae;Kwon, Yong-Kyu;Hong, Chang-Dong;Lee, Dong-Won;Min, Kyong-Nam
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.1
    • /
    • pp.103-111
    • /
    • 2020
  • Pulling-type cutting devices, which use a diamond wire saw, have been used generally for cutting concrete structures. In this study, a pushing-type cutting device with a collection cover was developed by overcoming the disadvantages of pulling-type devices. In this device, dry or liquid methods can be selected to cool frictional heat. Operation and leakage tests of the dust generated during the dismantling of a concrete structure were carried out, confirming the suitable operation of the fabricated cutting device; the leakage rate was approximately 1.7%. For a conservative evaluation, the internal dose of workers was estimated in dismantling the core center part of biological shield concrete with a specific activity of 99.5 Bq·g-1. The committed effective dose per worker was 0.25 mSv. The developed cutting device contributed to reducing radioactive concrete waste and minimizing worker exposure due to its easy installation. Therefore, it can be utilized as a cutting apparatus for dismantling not only reinforced concrete structures but also radioactive biological shield concrete in nuclear power plant decommissioning efforts.

Three-Dimensional Image Display System using Stereogram and Holographic Optical Memory Techniques (스테레오그램과 홀로그래픽 광 메모리 기술을 이용한 3차원 영상 표현 시스템)

  • 김철수;김수중
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.6B
    • /
    • pp.638-644
    • /
    • 2002
  • In this paper, we implemented a three dimensional image display system using stereogram and holographic optical memory techniques which can store many images and reconstruct them automatically. In this system, to store and reconstruct stereo images, incident angle of reference beam must be controlled in real time, so we used BPH(binary phase hologram) and LCD(liquid crystal display) for controlling reference beam. The reference beams are acquired by Fourier transform of BPHs which designed with SA(simulated annealing)algorithm, and the BPHs are represented on the LCD with the 0.05 seconds time interval using application software for reconstructing the stereo images. And input images are represented on the LCD without polarizer/analyzer for maintaining uniform beam intensities regardless of the brightness of input images. The input images and BPHs are edited using application software(Photoshop) with having the same recording scheduled time interval in storing. The reconstructed stereo images are acquired by capturing the output images with CCD camera at the behind of the analyzer which transforms phase information into brightness information of images. In output plane, we used a LCD shutter that is synchronized to a monitor that display alternate left and right eye images for depth perception. We demonstrated optical experiment which store and reconstruct four stereo images in BaTiO$_3$ repeatedly using the proposed holographic optical memory techniques.

The Usefulness of a Wearable Smart Insole for Gait and Balance Analyses After Surgery for Adult Degenerative Scoliosis: Immediate and Delayed Effects (척추측만증 환자의 수술 효과 평가 수단으로서 웨어러블 스마트 깔창을 이용한 보행분석의 유용성)

  • Seo, Min Seok;Shin, Myung Jun;Kwon, Ae Ran;Park, Tae Sung;Nam, Kyoung Hyup
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.2
    • /
    • pp.184-192
    • /
    • 2020
  • This study presents a gait analysis method (including time series analysis) using a smart insole as an objective and quantitative evaluating method after lumbar scoliosis surgery. The participant is a degenerative lumbar scoliosis patient. She took 3-min-gait-test four times(before and 8, 16, and 204-days after surgery) and 6-min-gait-test once(204-days after surgery) with smart-insoles in her shoes. Each insole has 8-pressure sensors, an accelerometer, and a gyroscope. The measured values were used to compare the characteristics of gait before and after surgery. The analysis showed that all of the patient's gait parameters improved after surgery. And after 6 months, the gait was more stable. However, after long walk, the swing duration of one leg was slightly shorter than that of the other again. It was a preclinical problem that could not be found in the visual examination by the practitioner. With this analysis method we could evaluate the improvement of patient quantitatively and objectively. And we could find a preclinical problem. This analysis method will lead to the studies that define and distinguish gait patterns of certain diseases, helping to determine appropriate treatments.

Relationship between Thermal Insulation and the Combinations of Korean Women's Clothing by Season - Using a Thermal Manikin - (한국 성인 여성의 계절별 의복조합과 보온력과의 관련성 - 써멀마네킨 실험에 의한 -)

  • Choi, Jeong-Wha;Ko, Eun-Sook
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.6 s.165
    • /
    • pp.966-973
    • /
    • 2007
  • The purpose of this study was to examine the correlation between the combination of women's clothing by season and thermal insulation using a thermal manikin. A total of 34 kinds of clothing ensembles were selected based on previous studies(8 types for spring/fall, 7 types for summer, and 19 types for winter). The results were as follows: The thermal insulation of clothing ensembles($I_{cle-total}$) ranged from $0.34{\sim}0.60clo$ for spring/fall, $0.16{\sim}0.37clo$ for summer, and $0.89{\sim}1.35clo$ for winter. The correlation coefficient between the thermal insulation of clothing ensembles and thermal insulation accumulated by the individual garments composing of the clothing ensembles($I_{cle-summed}$) was 0.982(p<0.001). The correlation coefficient between the thermal insulation of clothing ensembles and total clothing layers for the upper body part was 0.750 (p<0.001), for the total clothing weight was 0.978(p<0.001), and for the covering area was 0.776(p<0.001). In conclusion, $I_{cle-total}$ showed higher relationships to the $I_{cle-summed}$ and total clothing weight than to the total clothing layers or surface area covered by clothing.

Development of Bioelectric Signal Sensor System using Band Type ECG (밴드형 심전도 생체신호 전극시스템의 구현)

  • Kang Sung-Chul;Kim Gi-Ryon;Kim Kwang-Nyeon;Jung Dong-Keun;Kim Min-Sung;Jeong Do-Wun;Jeon Gye-Rok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.1023-1026
    • /
    • 2006
  • There are some cases in trouble with monitoring emergency patient by existing electrode sensor in measuring instrument in home and hospital etc. And there are problem to measure because of coming down electrode in emergency car or vessel of shaking and fat, humidity of patient. In this study, it has designed band-type for patient to put on the breast easily and go around anywhere freely putting band electrode on his body. Gold has used as electrode material in this electrocardiogram because of its excellent electronic resistance peculiarity and no trouble with skin. And it is able to monitor multi-body-signal by additional design of periphery temperature. There are good results of body signal transmission in the breast or the rib, and get a little body signal in abdomen. We get a result it is better case of gold than usual electrode on signal detection, and know usual electrode was disposable, but we have more correct result from gold electrode sensor, being semi-permanent ana. great contact ability even if movement.

  • PDF

The Change of the Phoria in Accordance with the Color and Concentration of the Color Lens (착색렌즈의 색상과 농도에 따른 원거리 사위도의 변화)

  • Choi, Hyun-Soo;Park, Sung-Jong;Lee, Seok-Ju;Jin, Moon-Seok;Jun, Jin;Ryu, Geun-Chang
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.339-343
    • /
    • 2011
  • Purpose: In this study, we investigated changes of phoria based on varying the color and concentration of the color in lenses. Methods: We measured distance phoria for 39 students who aged 20 to 40 with different concentrated lenes - red, gray, brown and green lenses in concentration 20%, 50% and 80%, respectively. Results: Subjects were divided into three groups which were orthophoria, esophoria and exophoria. Orthophoria in all the color and concentration, there were a few of the esophoria. Esophoria of average 2.07${\Delta}$,B.O showed that a slight increase in all colors and concentration, especially in brown lenses showed the greatest increase. Exophoria of average 3.82${\Delta}$,B.I showed that a slight decrease in all colors and concentration, especially in green lenses showed to 2.95${\Delta}$,B.I to the greatest decrease. Different concentration in same color had no specific tendency regarding phoria. Conclusions: The phoria must be considered when selecting color of the lens because of phoria is changeable by color of the lens. It is expected to study the criteria that minimize the asthenopia.

Development of Rashguard Swimwear Size System and Pattern for Middle-aged Women in Breast Cancer Patients

  • Han, Hyun-Sook;Sohn, Boo-Hyun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.6
    • /
    • pp.155-164
    • /
    • 2020
  • In this paper, we proposed the dimensional system and pattern of middle-aged women's rashguard swimwear for breast cancer patients. First, a survey of 37 breast cancer patients was conducted to determine the preferred swimsuit design for breast cancer patients. According to a survey of breast cancer patients, a rashguard swimwear with a low-exposure chest was designed. It has a pocket shape in which the cap is easy to insert and the cap is fixed. Second, we developed a dimensional system for swimsuits for breast cancer patients. Using direct measurement data from Size Korea for 1,625 women aged 30 to 69, 17-sizes for breast cancer patient's swimsuits were set through cross-analysis of major dimensions, with a coverage rate of 74.3%. It also extracted a standard size of bust circ. 90cm, hip circ. 95cm, and trunk circ. 150cm. Third, we developed a pattern for the central size of the swimsuit for breast cancer patients. For this purpose, we first produced the first central size pattern, and then completed the pattern after modifying it through the second and third wearing experiments. Experimental suits were produced at each pattern-making stage to evaluate wearing fit and motion suitability. Finally, the reduction rate of each dimension item for optimal pattern production was obtained, and the lashguard swimwear pattern for breast cancer patients was developed.

Fall detection based on acceleration sensor attached to wrist using feature data in frequency space (주파수 공간상의 특징 데이터를 활용한 손목에 부착된 가속도 센서 기반의 낙상 감지)

  • Roh, Jeong Hyun;Kim, Jin Heon
    • Smart Media Journal
    • /
    • v.10 no.3
    • /
    • pp.31-38
    • /
    • 2021
  • It is hard to predict when and where a fall accident will happen. Also, if rapid follow-up measures on it are not performed, a fall accident leads to a threat of life, so studies that can automatically detect a fall accident have become necessary. Among automatic fall-accident detection techniques, a fall detection scheme using an IMU (inertial measurement unit) sensor attached to a wrist is difficult to detect a fall accident due to its movement, but it is recognized as a technique that is easy to wear and has excellent accessibility. To overcome the difficulty in obtaining fall data, this study proposes an algorithm that efficiently learns less data through machine learning such as KNN (k-nearest neighbors) and SVM (support vector machine). In addition, to improve the performance of these mathematical classifiers, this study utilized feature data aquired in the frequency space. The proposed algorithm analyzed the effect by diversifying the parameters of the model and the parameters of the frequency feature extractor through experiments using standard datasets. The proposed algorithm could adequately cope with a realistic problem that fall data are difficult to obtain. Because it is lighter than other classifiers, this algorithm was also easy to implement in small embedded systems where SIMD (single instruction multiple data) processing devices were difficult to mount.

Convergence study of blue light transmittance comparison between tips for light curing machine and commercially available blue light blocking lenses and yellow tinted lenses (광중합기용 팁과 시판용 청광 차단 렌즈 및 노란색 착색 렌즈의 청광 투과율 비교 융합 연구)

  • Lee, Sook-Jeong
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.7
    • /
    • pp.125-131
    • /
    • 2021
  • Blue light with strong energy is required for light-curing resin treatment, which is being used more frequently in dentistry. To reduce the risk of exposure to scattered light, we tried to use colored lenses. The tips for light curing machine and a commercially available yellow-type blue-light blocking lens and a yellow lens colored with yellow dye, which are expected to be effective in blocking blue light, were placed in a UV-Vis spectrometer device, and transmission and blocking of blue light were tested respectively. As a result, the average blue light blocking rate of the light curing machine tips was 99.49%, and the C lens with the highest color density among commercially available lenses showed a high blue light blocking rate of 99.54%. In the case of lenses tinted with yellow, the yellow tinted C lens with the highest tint concentration showed 87.57% of blue light blocking rate. It is judged that the side effects related to the eyes caused by blue light can be reduced if a yellow-type commercially available or colored lens is worn along with a light curing machine tip during resin treatment.

Effects of Gaussian Magnetic Therapy on Body Temperature in Elderly Women with Delayed Onset Muscle Soreness (노년기 지연성 근육통증에 대한 가우스 자기장 치료가 신체 체열 변화에 미치는 영향)

  • Shin, Won
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.7
    • /
    • pp.538-545
    • /
    • 2019
  • The purpose of this study was to analyze the change of body temperature and pain by application of Gaussian magnetic for the elderly delayed muscle pain. For the purpose, we selected 15 elderly women(age;$69.47{\pm}1.60$) and conducted repeated experiments. The Gaussian magnetic field area was divided into three areas (1000G, 1500G, 2000G). The applying arbitrarily manufactured magnetic field wristbands changes of body heat and pain before and after wearing Gaussian magnetic were measured and collected data were analyzed using SPSS 19.0. To examine the pre-and post-treatment differences by treatment areas, we conducted paired t-test. Group differences and interaction effects were analyzed using two-way ANOVA and Duncan post hoc tests. The significance level was set to ${\alpha}=.05$. The results are as follows. The change of body heat by the Gaussian magnetic field area showed significant differences in all three groups(P<.05). There were also significant differences in the results of group interactions and in the delayed muscle pain scale between groups(P<.05). The area with the largest difference appeared in the area of 1500G field. The 1000G-1500G Gauss field is considered to be the most ideal magnetic field for body heat and muscle pain changes. In conclusion, the Gaussian magnetic field of 1000G-1500G may affect body temperature and muscle pain in the elderly, and may have a significant impact on the quality of life in old age.