• Title/Summary/Keyword: 착용효과

Search Result 374, Processing Time 0.023 seconds

Development of an Intelligent Legged Walking Rehabilitation Robot (지능적 족형 보행 재활 보조 로봇의 개발)

  • Kim, Hyun;Kim, Jung-Yup
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.9
    • /
    • pp.825-837
    • /
    • 2017
  • This paper describes a novel type of a walking rehabilitation robot that applies robot technologies to crutches used by patients with walking difficulties in the lower body. The primary features of the developed robot are divided into three parts. First, the developed robot is worn on the patient's chest, as opposed to the conventional elbow crutch that is attached to the forearm; hence, it can effectively disperse the patient's weight throughout the width of the chest, and eliminate the concentrated load at the elbow. Furthermore, it allows free arm motion during walking. Second, the developed robot can recognize the walking intention of the patient from the magnitude and direction of the ground reactive forces. This is done using three-axis force sensors attached to the feet of the robot. Third, the robot can perform a stair walking function, which can change vertical movement trajectories in order to step up and down a single stair according to the floor height. Consequently, we experimentally showed that the developed robot can effectively perform walking rehabilitation assistance by perceiving the walking intention of the patient. Moreover we quantitatively verified muscle power assistance by measuring the electromyography (EMG) signals of the muscles of the lower limb.

Refractive Power Changes after Removal of Contact Lenses (콘택트렌즈를 임시 제거한 상태에서의 착용 조건에 따른 굴절력 변화)

  • Cho, Yun-Kyung;Kim, Soo-Woon;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.279-289
    • /
    • 2013
  • Purpose: To evaluate the changes of refractive power when worn soft contact lenses were temporarily removed. Methods: 91 soft contact lens wearers (15 males and 76 females; total 182 eyes) from 17 to 39 years of age (average: $24{\pm}4.8$ years) were participated. Objective and subjective refraction, and corneal radius were measured at 0, 30, 60 and 90 min after lens removal. The changes in refractive power were evaluated between measurements over time. The other parameters such as types of lenses, fitting and wearing conditions were also assessed. Results: Objective refraction, subjective refraction and corneal radius were significantly changed according to measured time (p<0.0001). A moderate myopic shifts was observed at the beginning (30 min after lens removal) and a slight myopic shift at the late of measurement (60 min to 90 min after lens removal). There are no significant differences between lens types, fitting states, wearing time, wearing days and sleeping time in the previous day. However, there was significant interaction in changes for corneal radius between measuring time and lens type (p=0.017), fitting state (p=0.019), and sleeping time prior to the test (p=0.010). Conclusions: Time to reach refractive and corneal radius stability after contact lens removal revealed at least more than 60 min, regardless of types of lenses, fitting and wearing conditions. Therefore, refraction for correction should be performed after waiting for more than that time as possible.

중년남성 수트디자인에 따른 연상디자인 시각효과에 관한 연구

  • 박순천
    • Proceedings of the Korea Society of Costume Conference
    • /
    • 2003.05a
    • /
    • pp.46-46
    • /
    • 2003
  • 본 연구에서는 20∼50대의 남녀를 대상으로 중년 남성의 의복디자인에 따른 시각효과를 연상디자인적인 면에서 고찰하여 중년남성의 체형에 가장 적합한 의복디자인을 규명하는 것에 그 목적을 두었다. 중년남성의 체형을 균형화 시키는 연상디자인 시각효과를 유발시킬 수 있는 신사복 정장의 형태를 파악하기 위해 일반적으로 중년남성이 외출복으로 착용하는 정장스타일의 수트를 선정하여 의복디자인의 형태구성요인이 다르게 조합된 연상디자인 시각효과를 분석한다. 그리하여 체형결점을 보완할 수 있는 의복의 형태구성요인을 파악하여 사회적 상황에서 중년남성들이 표출하고 싶은 시각적 느낌을 효과적으로 드러낼 수 있는 체형에 대해서 적절하며 또한 효과적인 의복디자인을 제시하고자한다. 또한, 이와 관련된 소재에 따른 시각적 평가가 다르게 이루어질 것으로 판단되어 소재별 시각효과, 여밈 및 단추 수의 변화, 체형에 따른 시각효과의 차이에 관해서 알아보고자 하였다.

  • PDF

승객석 Restraiant System의 구속 효과와 인체상해 연구 -어린이(6세)탑승자 중심으로-

  • 이창민
    • Proceedings of the ESK Conference
    • /
    • 1997.10a
    • /
    • pp.398-405
    • /
    • 1997
  • 과거 8년간의(1985-1992) 통계에 의하면 정면과 측면 충돌시 구속 시스텡의 하나인 Airbag장착 차량의 사망자 및 중상자 수가 현저히 감소하고 있는 것으로 나타나고있다. 그 러나 최근 소비자로 부터의 Airbag에 관한 불만을 보고 받고 있다. 즉 구속효과를 발휘함에 있어 부수적으로 인체 부상을 유발하고 있다는 것이다. 사망내지는 심각한 부상은 방지하고 있으나 경미한 부상은 오히려 증가하고 또한 신체가 적은 여성 운전자나 6세 이하의 어린이 에게는 심각한 부상의 우려가 있다는 것이다. 본 연구에서는 구속시스템의 총아인 Airbag 시스템의 심각한 부수적인 부상 보고를 입증하기 위하여 우리나라 어린이 6세 신체를 기준 으로하여 구속시스템을 착용하지 않았을 경우(실제로 많은 경우), seat belt만 착용시, Airbag만 작용시, 그리고 seat belt와 Airbag을 동시에 사용할 때를 컴퓨터 Simulation Package 이용 신체 dynamic을 모의실험 하였다. 실험결과, 기존에 알려진바와 같이 구속시스템을 사용하지 않았을 경우에 부상은 매우 컸다. 신체 사이즈가 작은 어린이 혹은 여성 운전자의 경우 Seat belt만을 사용한 경우는 Airbag만을 사용한 경우보다는 부상정도가 약간 경미하였으나 두 경우 모두 인체가 구속시스템의 구속 범위를 이탈하여 구속 시스템으로써의 역할을 충분히 하지 못하고 있었다. 특히 Seat belt와 Airbag을 동시에 사용하였을시에도 Airbag이 충분히 개선된 이후라도 신체 사이즈가 작은 경우에는 흉부부위에 의한 충격 흡수가 먼저 이루어지지 못하고, 머리에 먼저 Airbag이 접촉이 되어 충격 흡수 역할보다는 반동효과가 더 커서 머리 및 몸체가 뒤로 Rebound 하는 효과로 머리, 혹은 목의 신체 부상한계를 넘고 있어 큰 부상 내지는 사망에 이르고 있음을 알 수 있었다. 사료된다.의 결과는 자전거 에르고노미터의 결과가 트레드밀의 결과에 87.60%정도 나타났다.음을 관찰하였다. 특히 vitamin C와 E의 병용투여는 상승적으로 적용하여 간세포손상을 더욱 억제시킴을 알 수 있었다.mance and on TFP(Total Factor Productivity) growth which is a pure measure of firm performance. To utilize the advantage of panel data, FEM(Fixed Effect Model) and REM(Random Effect Model) were used. The empirical result shows that the entropy index as a measurement of inter-business relatedness is not significant but technological relatedness index is significant. OLS estimates on pooled data were considerably different from FEM or REM estimates on panel data. By introducing interaction effect among the three variables for business portfolio properties, we obtained three findings. First, only VI (Vertical integration) has a significant positive correlation with ROS. Second, when using TFP growth as an dependent variable, both TR(Technological Relatedness) and f[ are significant and positively rel

  • PDF

The Effects of a Thyroid Shield Made of a Tissue-Equivalent Material on the Reduction of the Thyroid Exposure Dose in Panoramic Radiography (파노라마촬영 시 조직등가물질을 이용한 갑상선보호대의 갑상선피폭선량 감소효과)

  • Lee, Hye-Lim;Kim, Hyun-Yung;Choi, Hyung-Wook;Lee, Hye-Mi;Lim, Chang-Seon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.5
    • /
    • pp.2278-2284
    • /
    • 2012
  • Exposure-dose reducing effect was measured by using bolus, a tissue-equivalent material as a shield to obtain useful diagnostic images while minimizing the radiation exposure of thyroid which is highly sensitive to radiation during panoramic radiography. The experiment was performed within the period of 1 June 2001 through 30 June 2011 by measuring entrance surface dose and deep dose at the thyroid-corresponding site of a head and neck phantom. As a result, the entrance surface dose in the thyroid for using no shield was 43.84 ${\mu}Gy$ on the average, and the thyroid shield of bolus 10 mm in thickness reduced the dose by 15.45 ${\mu}Gy$(35.24%) to 28.39 ${\mu}Gy$ on the average. The use of a 20 mm thyroid shield resulted in the dose of 25.38 ${\mu}Gy$ on the average, a 18.46 ${\mu}Gy$(42.10%) drop from 43.84 ${\mu}Gy$ for using no shield. On the site 20 mm below the surface, a thyroid shield 10 mm in thickness had no dose-reducing effect, while a 20 mm thyroid shield reduced the dose by 0.06 mSv(20%).

The Effect of Gesture Based Interface on Presence Perception and Performance in the Virtual Reality Learning Environment (가상현실 학습환경에서 동작기반 인터페이스가 실재감 지각 및 수행에 미치는 효과)

  • Ryu, Jeeheon;YU, SEUNGBEOM
    • (The)Korea Educational Review
    • /
    • v.23 no.1
    • /
    • pp.35-56
    • /
    • 2017
  • This study is to examine the effects of gesture based interface and display methods to make an effective virtual learning environment. The gesture based interface can provide interactive interface to make objects in the virtual learning environment by generating natural movement of users' gesture. This natural functionality leads users to apply natural movements as they do in real actions. Because of the natural user interface, the gesture based interface is expected to maximize learning outcomes. This study examined how the gesture based interface can be used when a head mounted display is applied for a virtual reality learning environment. For this study 44 colleagues students were participated. Two display methods (head mounted display vs. monitor) and two interface (gesture based interface vs. joystick) were tested to identify which might be more effective. The study was applied to different learning tasks which require different levels of spatial perception. The dependent variables are three constructs of virtual presence (spatial perception, immersiveness, and realness) and task completion time and recall tests. This study discussed potential disadvantages of gesture based interface while it showed positive usages of gesture based interface.

Study of Masking Effect of Soft Contact Lenses on Cornea after Refractive Surgery (각막굴절교정 수술 안에 대한 소프트콘택트렌즈 착용 시 Masking 효과)

  • Moon, Ye-Rim;Park, Hyung-Min;Chu, Byoung-Sun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.2
    • /
    • pp.91-98
    • /
    • 2016
  • Purpose: This study investigated the masking effect of the hydrogel lens and silicone hydrogel lens on the cornea with refractive surgery and without surgery. Methods: 24 university students (means age: $23.48{\pm}2.89years$) without refractive surgery (12, control group) and with refractive surgery (LASIK: 8, LASEK: 4, experimental group) participated in the study. Mean refractive errors of right eyes were -2.73 D for control group and -0.24 D for experimental group. The differences in the refractive power and corneal topography map between pre- and post-wearing the -3.00 D lenses were compared, and 2 kinds of hydrogel contact lenses (0.89 Mpa, 0.49 Mpa) and 2 kinds of silicone hydrogel lenses (1.5 Mpa, 0.8 Mpa) were used for -3.00 D lenses. NVision-K5001 (Shin nippon, Japan) was used to measure the refractive power and Keratograph 5M (Oculus, Germany) to measure the corneal topography map change. Results: Variations in the refractive power increased to the plus direction in the experimental group after wearing soft contact lenses. The corneal topography map showed significant changes on the both groups after wearing soft contact lenses (p<0.05). However there were no significant differences in the refractive power and corneal topography map variations by lens materials. Conclusions: Wearing soft contact lenses showed corneal topography map changes. Especially wearing soft contact lenses on the flat cornea after corneal refractive surgery showed greater corneal power changes. Therefore, it should pay attention to refractive change in case of prescribing soft contact lenses to patients with corneal refractive surgery.

A Comparison of the Effects between Eye-Mask and Light-Off Conditions on Psychiatric Patient Sleep (야간 조명 하 안대와 소등의 수면에 대한 효과 비교)

  • Shin, Juyong;Lim, Kyoung-Ok;Cho, Seongnam;Jang, Soyeong;Cha, Seung-Min;Han, Songyi;Kim, Moojin
    • Sleep Medicine and Psychophysiology
    • /
    • v.28 no.1
    • /
    • pp.27-33
    • /
    • 2021
  • Objectives: The purpose of this study is to investigate the difference in the effects of eye-mask and light-off on sleep status according to a commercial fitness tracker and a sleep diary of psychiatric in-patients in correctional facilities where nocturnal light is compulsory. Methods: This study was conducted over 3 consecutive nights. In-patients of the National Forensic Psychiatric Hospital (n = 29) were assigned random subject numbers and slept as usual in the light-on condition on the first night. The subjects slept with eye-masks in the light-on condition on another night and without an eye-mask in the light-off condition on the other night. Subjects were asked to sleep wearing a commercial fitness tracker and to keep a sleep diary. The order of these changes in bedroom lighting condition on the second and third nights was assigned randomly to participants. Results: In comparison of the sleep variables between the light-on condition and the eye-mask condition, the Wakefullness After Sleep Onset (WASO) was shorter and sleep satisfaction was higher in the latter.(respectively, Z = 3.66, p < 0.017 ; Z = 2.69, p < 0.017) In comparison of the sleep variables between the light-on and light-off conditions, the WASO was shorter and sleep efficiency and sleep satisfaction were higher in the latter (respectively, Z = 2.40, p < 0.017 ; Z = 3.02, p < 0.017 ; Z = 3.88, p < 0.017). However, there were no differences in the sleep variables between the eye-mask condition and the light-off condition. Conclusion: Subjective improvements in sleep variables were noted in sleep diaries of institutionalized psychiatric patients under either the 'eye-mask' or 'light-off' condition. However, there were no significant differences between the 'eye-mask' and 'light-off' conditions. Therefore, we suggest that psychiatric patients in correctional facilities use eye-masks when sleeping.

The Study on Improvement of Reading Ability for Dyslexia Wearing Color filter lens (ChromaGenTM Lens) (칼라필터 렌즈(ChromaGenTM)를 이용한 읽기능력 향상에 대한 임상연구)

  • Lee, Seok-Ju;Park, Ji-Hoon;Lee, So-Hee;Whang, Kwang-Ha;Ryu, Guen-Chang
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.65-74
    • /
    • 2011
  • Purpose: In this study we investigated improvement degree of reading ability of the student who was in a condition of dyslexia symptoms by wearing $ChromaGen^{TM}$ lenses. Methods: After wearing the $ChromaGen^{TM}$ lens for 3 months, the dyslexia symptoms corrective lens, 52 students who had suspected symptom of dyslexia were asked questions, and we measured the improvement degree of reading ability of the student. Results: The $ChromaGen^{TM}$ wearer read 110.26${\pm}$22.07 words in 1 minute, and naked yeses or glass wearing students read 106.42${\pm}$22.70 words. Reading ability of the student having suspected symptom of dyslexia were measured after wearing $ChromaGen^{TM}$ for 3 months. The results showed improvement reading ability of 3.70${\pm}$0.29 (p=0.01, t=2.26), 4.50%${\pm}$0.10 (p=0.01, t=2.78) for $ChromaGen^{TM}$ wearer with statistical difference. A survey on the satisfaction of reading improvement with wearing $ChromaGen^{TM}$ showed that 88.4% of questioned person answered wearing $ChromaGen^{TM}$ had improved their dyslexia symptoms. Conclusions: With statisical significance (p<0.05). this study suggests that $ChromaGen^{TM}$ lens has an effect on improving reading speed of dyslexia patient. We know from these results that the $ChromaGen^{TM}$ lens which is used to dyslexia had an effect to improvement of reading speed for dyslexia. And the results of this study is statistically different (p<0.05).

The Impact of Traffic Safety Measures on Reducing Traffic Accidents (교통안전정책 강화의 교통사고 감소효과 분석)

  • Myeong, Myo-Hui;Kim, Gwang-Sik
    • Journal of Korean Society of Transportation
    • /
    • v.24 no.3 s.89
    • /
    • pp.113-123
    • /
    • 2006
  • This article evaluates the effects of eight traffic safety policies such as traffic accident reduction campaign, the seat belt law, three strike out driving while intoxicated, rewarding for reporting traffic offenders on the number of accidents and fatalities. Intervention analysis of time series is used to compare the monthly accident and fatalities with the before and after reinforcement. The results indicate that no significant impact of the traffic enforcement measures on reducing the number of accidents and fatalities.