A study on Manufacture of EMI Composite Powder by the Electroless Ni Plating Method (무전해 니켈도금방법을 이용한 EMI 복합분말제조에 관한 연구)

  • Joung, I.;Yoon, S.R.;Han, S.N.;Na, J.H.;Kim, C.W.
    • Korean Journal of Materials Research
    • /
    • v.8 no.5
    • /
    • pp.444-449
    • /
    • 1998
  • There are various shielding materials that have been considered; the use of a metallic plate or the layering of a conductive material on a plastic surface and the insertion of filler in plastics. All of these methods have shown their merits and weakness. Therefore, many studies have concentrated on developing materials that effectively cut down EMI without increase in weights of housing materials. In these respects, this study has focused on investigations of the shielding effect of materials that have electroless nickel plating on the lamella structured micro particles surface with low specific gravity. When a film of electroless nickel were plated on a micro particle surfaces and then mixed with paint, the electromagnetic shielding effects were measured as 63dB. Although these effects were less than that 90dB of the copper plate, trials in a series of 6 times increased the shielding effect by IOdB and is applicable to wide range of EMI shielding.

  • PDF

A Study on the Apron Shielding Ratio According to Electromagnetic Radiation Energy (감마선 에너지에 따른 납치마의 차폐효과 분석)

  • Jang, Dong-Gun;Lee, Sang-Ho;Choi, Hyung-Seok;Son, Joo-Chul;Yoon, Chang-Yong;Ji, Yung-Sik;Cho, Yong-In;Lee, Hong Je;Yang, Seoung-Oh
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.247-252
    • /
    • 2014
  • The medical institution has been used electromagnetic radiation of various energy. But researchers are divided on whether using apron for radiation shielding will be effective or not. The purpose of present study was to analyze electromagnetic radiation shielding effect of apron by using Monte carlo simulation. 1 MBq electromagnetic radiation was emitted from 10-500 keV at 10 keV increments in Monte carlo simulation. Then shielded radiation dose difference was confirmed, when 0.25 mmPb shield use for shielding. As a results, shielding ratio was markedly decreased in high energy electromagnetic radiation. The radiation dose was inversely increased with 0.25 mmPb shielding.

Evaluation of the Usefulness of Tungsten Nanoparticles as an Alternative to Lead Shielding Materials in Electron Beam Therapy (전자선 치료시 납 차폐체 대체물질로서의 텅스텐 나노입자의 유용성 평가)

  • Kim, Ji-Hyang;Kim, Na-Kyoung;Lee, Gyu-Yeong;Jung, Da-Bin;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.949-956
    • /
    • 2021
  • The purpose of this paper is to evaluate whether tungsten nanoparticles have a shielding effect on scattered light generated at high doses as an alternative material to lead used to shield scattered light in electron beam therapy. A plate was manufactured to set the position of the dosimeter and the size of the radiation field to be constant. The glass dosimeter was placed at 12 points, which were 1, 2, and 4 cm apart from the center of the field of 10 × 10 cm2 in the cross direction. A total of 12 types of tungsten nanoparticle shields were developed with a thickness of 0.75 mm to 4.00 mm and a size of 10 × 10 cm2 using 0.4, 0.75, and 1 mm materials. Using a linear accelerator, measurements were made four times at 6 MeV and four times at 12 MeV, and the dose intensity was investigated at 100 MU. The 4 mm shielding plate showed the highest shielding effect at 1 cm from the irradiation field. The 1 mm shielding plate at 2 cm from the irradiation field had the lowest shielding effect. As the thickness of the tungsten shielding plate increased, the electron beam's shielding effect increased sharply. It was confirmed that tungsten nanoparticles can reduce the amount of scattered light generated by electron beam therapy. Therefore, this study will provide basic data when follow-up studies are conducted on the shielding ability of tungsten nanoparticles.

Measurement of Screening Effect by Metal Pipe on Induced Voltage to Communication Cable from Electric Railway (전기철도에서의 통신선 유도전압에 대한 금속관 차폐효과 측정)

  • Seol, Il-Hwan;Choi, Kyu-Hyoung;Lee, Sang-Mu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.4
    • /
    • pp.2355-2362
    • /
    • 2014
  • Electric railway induces interference voltage on wayside communication cable which brings about communication errors, malfunction of devices, and safety problem. The magnitude of the induced voltage depends on the electromagnetic field coupling which is affected by metallic installations such as rail and track structures. This paper provides an experimental analysis of the screening effect of metallic pipe on the inductive voltage caused on communication cable. The measurements at a high-speed rail site show that the screening effect of metallic pipe is about 20% when the separation distance between the pipe and communication cable is 1~2 m. The screening effects is less than 1% and can be neglected when the separation distance is more than 4 m. These results are useful to evaluate the screening effects of the metallic installations such as water pipe, gas pipe, and reinforcing bar.

메탈파우더/섬유강화 복합재료의 전자파 차폐효과

  • 한길영;안동규;이상훈;김민수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.55-55
    • /
    • 2004
  • 최근 전기 전자 장치의 사용이 급속하게 증가하고 있다. AC모터, 프린터, 디지털 컴퓨터, 계산기, 핸드폰 등과 같은 장비들은 많은 전자파를 방출하고 있다. 이러한 전자파에 노출로 암과 같은 질병이 발생할 수도 있다는 논란이 전 세계적으로 관심이 집중되고 있으며, 전자파에너지를 차패할 수 있는 재료 개발의 필요성이 절실히 요구되고 있는 실정이다. 일반적으로 금속과 합금이 전자파 차폐목적으로 사용되었다 그러나 이러한 재료들은 중량이 무겁고 가요성이 떨어지는 단점이 있다.(중략)

  • PDF

Shielding Analysis of the Material and Thickness of Syringe Shield on the Radionuclide (방사성 핵종별 주사기 차폐기구의 재질 및 두께에 대한 차폐분석)

  • Cho, Yong-In;Kim, Chang-Soo;Kang, Se-Sik;Kim, Jung-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.7
    • /
    • pp.282-288
    • /
    • 2015
  • A monte carlo simulation about shielding material and thickness of the syringe shield for radiation shield was performed. As a result of analysis, high atomic number materials such as tungsten, lead and bismuth have the highest shielding effect. However, $^{18}F$, $^{67}Ga$ and $^{111}In$ show high energy distribution in the region with thin shielding thickness. As the thickness of shielding materials increased, the energy distribution decreased due to reduction of ${\gamma}$-ray. In the case of low atomic number materials, they, showed energy distribution from highest to lowest, were barium sulfate, steel, stainless, iron and copper. Aluminum, plastic, concrete and water showed diverse aspect. they showed relatively high energy distribution because of increased ${\gamma}$-ray that penetrate the shield.

Study on the Development of an Outdoor Radiographic Test Shield Using 3D Printer Filament Materials (3D 프린터 필라멘트 재료를 이용한 야외 방사선투과검사용 차폐체 개발을 위한 연구)

  • Mun, Ik-Gi;Shin, Sang-Hwa
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.565-572
    • /
    • 2019
  • In this study, shielding analysis of material and thickness of 3D printer filaments was performed for the manufacture of custom shielding by radiation workers during outdoor radiographic test. The shielding was attached to the ICRU Slab Phantom after selecting the voxel source $^{192}Ir$ and $^{75}Se$ through simulation using MCNPX, and the distance between the source and the slab Phantom was set at 100 cm. The 12 shielding materials were divided into 5 mm units up to 200 mm from the absence of shielding materials to evaluate the energy absorbed per unit mass of each shielding material. The results showed that the shielding effect was high in the order of ABS + Tungsten, ABS + Bismuth, PLA + Copper, PLA + Iron from all sources of radiographic test. However, compared to lead, the shielding effect was somewhat lower. Based on this study in the future, further study of the atomic number and the high density filament material is necessary.

Assessment of Radiation Shielding Ability of Printing Materials Using 3D Printing Technology: FDM 3D Printing Technology (3D 프린팅 기술을 이용한 원료에 대한 방사선 차폐능 평가: FDM 방식의 3D 프린팅 기술을 중심으로)

  • Lee, Hongyeon;Kim, Donghyun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.909-917
    • /
    • 2018
  • 3D printing technology is expected to be an innovative technology of the manufacturing industry during the 4th industrial revolution, and it is being used in various fields including biotechnology and medical field. In this study, we verified the printing materials through Monte Carlo simulation to evaluate the radiation shielding ability of the raw material using this 3D printing technology. In this paper, the printing materials were selected from the raw materials available in a general-purpose FDM-based 3D printer. Simulation of the ICRU phantom and the shielding system was carried out to evaluate the shielding effect by evaluating the particle fluence according to the type and energy of radiation. As a result, the shielding effect tended to decrease gradually with increasing energy in the case of photon beam, and the shielding effect of TPU, PLA, PVA, Nylon and ABS gradually decreased in order of materials. In the case of the neutron beam, the neutron intensity increases at a low thickness of 5 ~ 10 mm. However, the effective shielding effect is shown above a certain thickness. The shielding effect of printing material is gradually increased in the order of Nylon, PVA, ABS, PLA and TPU Respectively.

The Consolidation and Comparison Processes in Visual Working Memory Tested under Pattern-Backward Masking (역행 차폐를 통해 본 시각작업기억의 공고화 및 비교처리 과정)

  • Han, Ji-Eun;Hyun, Joo-Seok
    • Korean Journal of Cognitive Science
    • /
    • v.22 no.4
    • /
    • pp.365-384
    • /
    • 2011
  • A recent study of visual working memory(VWM) under a change detection paradigm proposed an idea that the comparison process of VWM representations against incoming perceptual inputs can be performed more rapidly than the process of forming durable memory representations into VWM. To test this hypothesis, we compared the size of interference effect caused by pattern-backward masks following after either the sample(sample-mask condition) or test items (test-mask condition). In Experiment 1, subjects performed a color change detection task for four colored-boxes, and pattern masks with mask-onset asynchronies(MSOA) of either 64ms or 150ms followed each item location either after the sample or after the test items. The change detection accuracy was both comparable in the sample-mask condition regardless of the MSOAs, whereas the accuracy in the trials with a MSOA of 150ms was substantially higher than the MSOA of 65ms in the test-masking condition. In Experiment 2, we manipulated setsizes to 1, 2, 3, 4 items and also MSOAs to 117ms, 234ms, 350ms, 484ms and compared the pattern of interference across a variety of setsize and MSOA conditions. The sample-mask condition yielded a pattern of masking interference which became more evident as the setsize increases and as the MSOA was shorter. However, this pattern of interference was less apparent in the test-mask condition. These results indicate that the comparison process between remembered items in VWM and perceptual inputs is less vulnerable to interference from pattern-backward masking than VWM consolidation is, and thus support for the recent idea that the comparison process in VWM can be performed very fast and accurately.

  • PDF

Evaluation of Electromagnetic Shielding Performance of SiC and Graphite Mixed Mortar (SiC 및 흑연 혼입 모르타르의 전자파 차폐 성능 평가)

  • Park, Oh-Seong;Cho, Hyeong-Kyu
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.5
    • /
    • pp.459-468
    • /
    • 2021
  • Blocking electromagnetic waves on the exterior walls of buildings effectively reduces the intensity of electromagnetic fields in buildings, which leads to attenuation of electromagnetic disturbances, so there is a great interest in developing technologies. In this study, SiC by-products and graphite generated in the semiconductor field were selected and mixed into mortar after pretreatment such as pulverization to evaluate their physical properties and electromagnetic wave shielding performance. Considering the economic efficiency of each shielding material, only 10% volume of the outermost side of the experiment was mixed with each shielding material to evaluate the shielding performance. The shielding performance was predicted when the experiment was manufactured by mixing the shielding material with the entire volume of the experiment using the shielding effect evaluation formula. The results of the experiment showed that the shielding performance was up to 20 dB when SiC grains were mixed with shielding materials, the shielding performance was up to 18 dB when graphite powder was mixed with shielding materials, and the shielding performance was up to 28 dB when SiC powder was mixed with shielding materials, and the shielding performance was close to 30 dB, which is known to have a shielding rate of 99.9%.