• Title/Summary/Keyword: 차폐복

Search Result 38, Processing Time 0.033 seconds

Magnetic field Reduction characteristics of shielding wear for a worker by using AC Arc welder. (교류 아크용접기를 사용하는 작업자의 차폐복 자계저감 특성검토)

  • Park, Jun-Hyeong;Min, Suk-Won
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1343-1344
    • /
    • 2008
  • This paper analyses current densities induced inside a worker using AC arc welder when he wears a protective cloth. Applying the boundary element method, we calculate current densities induced in organs inside a worker in case he was located at 1[cm], 15[cm], 20[cm] far from a power cable of AC arc welder. As results of study, we find a maximum current density induced in all organs may be lower than 10[$mA/cm^2$] if he wears a protective cloth. We also know high permeability materials can lower current density more than high conductivity materials.

  • PDF

Magnetic Field Reduction Characteristics of Shielding Wear Materials for Workers Using AC Arc Welder (교류 아크용접기를 사용하는 작업자의 차폐복 재질에 따른 자계저감 특성검토)

  • Park, Jun-Hyeong;Min, Suk-Won;Lee, Seung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.7
    • /
    • pp.1265-1271
    • /
    • 2010
  • Power cable of an AC arc welder can surround a body of worker at the moment of welding. Applying the boundary element method, we calculated current densities induced in organs inside a worker to study the magnetic field reduction characteristics of shielding wear materials. We knew shielding wear with high permeability materials lowers current density more than high conductivity materials. We also found current density was lowest when high permeability materials were inside high conductivity materials in double layer shielding wear.

Characterization of FeCo Magnetic Metal Hollow Fiber/EPDM Composites for Electromagnetic Interference Shielding (FeCo 자성 금속 중공형 섬유 고분자 복합재의 전자파 차폐 특성 연구)

  • Choi, Jae Ryung;Jung, Byung Mun;Choi, U Hyeok;Cho, Seung Chan;Park, Ka Hyun;Kim, Won-jung;Lee, Sang-Kwan;Lee, Sang Bok
    • Composites Research
    • /
    • v.28 no.6
    • /
    • pp.333-339
    • /
    • 2015
  • Electromagnetic interference shielding composite with low density ($1.18g/cm^3$) was fabricated using electroless plated FeCo magnetic metal hollow fibers and ethylene propylene diene monomer (EPDM) polymer. Aspect ratio of the fibers were controlled and their hollow structure was obtained by heat treatment process. The FeCo hollow fibers were then mixed with EPDM to manufacture the composite. The higher aspect ratio of the magnetic metal hollow fibers resulted in high electromagnetic interference shielding effectiveness (30 dB) of the composite due to its low sheet resistance (30 ohm/sq). The enhanced electromagnetic interference shielding effectiveness was mainly attributed to the formation of conducting network over the percolation threshold by high aspect ratio of fibers as well as an increase of the reflection loss by impedance mismatch owing to low sheet resistance, absorption loss, and multiple internal reflections loss.

Design and Frequency Characteristic Analysis of Shielded Isolation Transformer for the Power Line Noise Reduction (전원노이즈 억제용 차폐절연변압기의 설계 및 주파수특성 해석)

  • 이재복;허창수;이태호
    • Journal of the Korean Magnetics Society
    • /
    • v.9 no.1
    • /
    • pp.55-63
    • /
    • 1999
  • It is necessary to eliminate the broad band noise whose frequency is in the range of several kHz to tens MHz generated from the AC power line to supply the power to electrical and electronic equipments. Because this kind of noise could damage or malfunction such equipments. To suppress those noises, some conventional devices such as a filter or surge suppressor have been used. However, they can not be isolated from the common-mode noise widely spreaded in all power line, which results in poor common-mode rejection performance. In this paper, we proposed a design method of shielded isolation transformer and a jumped circuit analysis model for shielded isolation transformer applicable to filtering common-mode noise as well as normal-mode noise. The analysis model has been verified as a suitable one for shielded isolation transformer through comparison of the simulation with experiment. In addition, it has been shown that the reduction performance for conducted noise of prototype 3 kVA shielded isolation transformer is superior to a unshielded isolation transformer.

  • PDF

A Conductive-grid based EMI Shielding Composite Film with a High Heat Dissipation Characteristic (전도성 그리드를 활용한 전자파 흡수차폐/방열 복합소재 필름)

  • Park, Byeongjin;Ryu, Seung Han;Kwon, Suk Jin;Kim, Suryeon;Lee, Sang Bok
    • Composites Research
    • /
    • v.35 no.3
    • /
    • pp.175-181
    • /
    • 2022
  • Due to the increasing number of wireless communication devices in mmWave frequency bands, there is a high demand for electromagnetic interference (EMI) shielding and heat dissipating materials to avoid device malfunctions. This paper proposes an EMI shielding composite film with a high heat dissipation characteristic. To achieve this, a conductive grid is integrated with a polymer-based composite layer including magnetic and heat dissipating filler materials. A high shielding effectiveness (>40 dB), low reflection shielding effectiveness (<3 dB), high thermal conductivity (>10 W/m·K), thin thickness (<500 ㎛) are simultaneously achieved with a tailored design of composite layer compositions and grid geometries in 5G communication band of 26.5 GHz.

Mitigation Effect on the Magnetic Field of Transmission Lines (Passive Loop에 의한 송전선로 자계 저감 효과 분석)

  • Myung, Sung-Ho;Yang, Kwang-Ho;Lee, Jae-Bok;Ju, Mun-No
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1142-1144
    • /
    • 1999
  • 본 논문에서는 최근 선진국에서 활발히 연구중인 EMF 차폐 대책의 일환인 수동 루프에 대한 이론적 분석 방법을 기술하고, 송전선로 자계 저감 효과를 실제 우리나라 345kV, 765kV를 대상으로 정량적 효과를 분석하였다. 그 결과 수동 루프를 적용한 경우, 약 30% 정도의 자계 저감 효과를 나타내어 전력설비의 유효한 대책임을 확인하였다.

  • PDF

Invivo Dosimetry for Mammography with and without Lead Apron Using the Glass Dosimeters (유방촬영술에서 유리선량계를 이용한 납치마의 선량차폐 효과 측정)

  • Yu, Su-Jeong;Lim, Sangwook;Ma, Sun Young;Seo, Sun-Youl;Kim, Young-Jae;Kang, Young-Nam;Keum, Ki Chang;Cho, Samju
    • Progress in Medical Physics
    • /
    • v.26 no.2
    • /
    • pp.93-98
    • /
    • 2015
  • The purpose of this study is to see the usefulness of lead apron for critical organs near the breast under examining. For clinical experiment, 30 female volunteers who agreed to their participation in the experiments, were chosen and divided into two groups, 15 in group A and 15 in group B respectively. group A is to see whether each side of breast under mammography affects to other side glandular on the critical organs is same, because it is not allowed to scan the both breast for same person or to scan repeatedly. Group B is to see the effectiveness of lead apron during the mammography of right breast. Glass dosimeters were placed on the thyroid, the contralateral breast, and lower abdomen where near the breast during examining. The average glandular doses on the surface in mammography of the thyroid gland, the contralateral breast, the lower abdomen were 0.0692 mGy, 0.6790 mGy, and 0.0122 mGy, respectively, which was an extremely low level of glandular dose. In group B, as to the thyroid gland, average dose was decreased from 0.0922 mGy to 0.0158 mGy. The average dose of contralateral breast was decreased from 0.8575 mGy to 0.0286 mGy. The average doses of lower abdomen was decrease 0.0150 mGy to 0.0173 mGy. As to the lower abdomen, dose decreased from 0.0150 mGy before the use of an apron down to 0.0173 mGy after the use. As p-value was under 0.05, statistically significant difference was observed between the two groups. Wearing an apron can have the protective effects on the thyroid gland up to 20 times lower than not wearing one. Besides, it is also necessary to protect the other breast during the examination by wearing one.

Reliability Verification of FLUKA Transport Code for Double Layered X-ray Protective Sheet Design (이중 구조의 X선 차폐시트 설계를 위한 FLUKA 수송코드의 신뢰성 검증)

  • Kang, Sang Sik;Heo, Seung Wook;Choi, Il Hong;Jun, Jae Hoon;Yang, Sung Woo;Kim, Kyo Tae;Heo, Ye Ji;Park, Ji Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.547-553
    • /
    • 2017
  • In the current medical field, lead is widely used as a radiation shield. However, the lead weight is very heavy, so wearing protective clothing such as apron is difficult to wear for long periods of time and there is a problem with the danger of lethal toxicity in humans. Recently, many studies have been conducted to develop substitute materials of lead to resolve these problems. As a substitute materials for lead, barium(Ba) and iodine(I) have excellent shielding ability. But, It has characteristics emitting characteristic X-rays from the energy area near 30 keV. For patients or radiation workers, shielding materials is often made into contact with the human body. Therefore, the characteristic X-rays generated by the shielding material are directly exposured in the human body, which increases the risk of increasing radiation absorbed dose. In this study, we have developed the FLUKA transport code, one of the most suitable elements of radiation transport codes, to remove the characteristic X-rays generated by barium or iodine. We have verified the reliability of the shielding fraction of the structure of the structure shielding by comparing with the MCPDX simulations conducted as a prior study. Using the MCNPX and FLUKA, the double layer shielding structures with the various thickness combination consisting of barium sulphate ($BaSO_4$) and bismuth oxide($Bi_2O_3$) are designed. The accuracy of the type shown in IEC 61331-1 was geometrically identical to the simulation. In addition, the transmission spectrum and absorbed dose of the shielding material for the successive x-rays of 120 kVp spectra were compared with lead. In results, $0.3mm-BaSO_4/0.3mm-Bi_2O_3$ and $0.1mm-BaSO_4/0.5mm-Bi_2O_3$ structures have been absorbed in both 33 keV and 37 keV characteristic X-rays. In addition, for high-energy X-rays greater than 90 keV, the shielding efficiency was shown close to lead. Also, the transport code of the FLUKA's photon transport code was showed cut-off on low-energy X-rays(below 33keV) and is limited to computerized X-rays of the low-energy X-rays. But, In high-energy areas above 40 keV, the relative error with MCNPX was found to be highly reliable within 6 %.

High Fidelity Calculation of Thermal Load in a Satellite Orbit (고정확도의 인공위성 궤도 열하중 계산 기법)

  • Kim, Min-Ki
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.10
    • /
    • pp.898-906
    • /
    • 2017
  • This paper discusses the efficient high fidelity calculation of external thermal loads of a spacecraft on its orbit. Thermal loads to a spacecraft consist of three major components, direct solar radiation, earth reflection of solar rays, and earth irradiation. With the assumption that both earth reflection and earth emission are diffuse, thermal loads from earth surface divided into pieces of segments to satellite surfaces are individually calculated and summed over. By using analytical integration of both reflected and emitted heat load by earth, high rate of numerical convergence is achieved and the results are even exactly calculated in special cases. Moreover, KD tree ray tracing is employed in the calculation of thermal load to determine whether the radiated ray is obstructed or not by satellite structure.

A Design Approach for High Homogeneity Superconducting Magnet with Superconducting Active Shield (고균일 자계발생용 초전도 능동차폐 마그네트의 설계에 관한 연구)

  • Lee, K.H.;Kim, S.D.;Cho, Y.H.;Lee, J.B.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.151-153
    • /
    • 1996
  • An optimal design approach is presented for high homogeneity superconducting magnet with superconducting active shield especially for use in magnetic resonance imaging system. This paper is investigated phenomena for the stray magnetic field to get a basic reduction techniques of the unwanted stray magnetic field from the magnet. The present method obtains optimal coil configuration considering constraints for magnetic field homogeneity and leakage field.

  • PDF