• Title/Summary/Keyword: 차폐기구

Search Result 60, Processing Time 0.032 seconds

Fabrication and Characteristics of Shielding Effects for the Complex Conductive Filler (복합 전도성 필러의 제작과 전자파 차폐 특성)

  • Park, Ju-Tae;Park, Jae-Sung;Do, Young-Soo
    • 전자공학회논문지 IE
    • /
    • v.43 no.4
    • /
    • pp.122-127
    • /
    • 2006
  • A series of conductive filler were prepared with electroless plating method. Base conductive materials of the filler were nickel and copper. The cores were prepared with Nylon 6 and rayon in different aspect ratio. Also, various complexes were made with ABS resin and conductive filler with different filler feed ratio. The conductivity of the filler was measured with conductivity analyzer and the size distributions of fillers was measured with laser particle size analyzer. Electromagnetic wave shielding efficiency of each complex film was measured with flange circular coaxial transmission line sample holder within the 1MHz$\sim$1GHz bandwidth range. From this study, the conductivity of filers surpass that of other carbon films. It is available that the filler made of fibrous materials can be applied in plastic molding industry of electric appliances as a EMI filler.

Performance comparison of wireless MAC protocols for wireless LANs in the radio channel with rayleigh fading, shadowing and near-far effects (Rayleigh 페이딩, 차폐현상 및 Near-far현상을 고려한 무선 채널에서의 무선 LAN용 매체접근제어 프로토콜 성능비교)

  • 김재현;신형철;이정규
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.9
    • /
    • pp.1843-1853
    • /
    • 1997
  • The channel throughput and packet delay of wireless media control (MAC) protocols with Rayleigh fading, log-normal shoadowing and near-far effects are analyzed. We consider CSMA/CA protocols as the wireless MAC protocols, since CSMA/CA protocols are based on the standard for wireless Local Area Networks (LANs) IEEE 802. 11. We have found that the performance of CSMA/CA in radion channel model is reduced above 50% than those of error free channel model in low traffic load. We also found that 4-Way Handshake CSMA/CA protocol is supterior to the other CSMA/CA protocols in high traffic load.

  • PDF

Evaluation of the Apron Effectiveness during Handling Radiopharmaceuticals in PET/CT Work Environment (PET/CT 업무 환경에서 선원 취급 시 Apron의 실효성 평가)

  • Cho, Yong-In;Ye, Soo-Young;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.237-244
    • /
    • 2015
  • Health professionals in nuclear medicine were known that they get high radiation exposure. To reduce radiation exposure, using shielding materials is needed. In this study, we analyzed the shielding effect about apron during 18F-FDG treatment by using simulation based on Monte Carlo techniques and actual measurement. As a result, absorbed dose distribution of organ varies with handling position of the source. Dose reduction ratio by lead thickness of apron tended to decease, when handling position of the source come close to organ and away from radiation source for simulation. In the case of actual measurement with the dosimetry device, It showed that mean spatial dose distribution was different due to characteristics of dosimetry device. However, spatial dose rate was exponentially reduced according to distance with increasing lead content.

Evaluation of the Usefulness of 3D Printed Shielding Materials Using Monte Carlo Simulation during Mammography (유방 X선 검사 시 몬테카를로 시뮬레이션을 이용한 3D 프린팅 차폐재료의 효용성 평가)

  • Cho, Yong In
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.295-301
    • /
    • 2020
  • Radiation exposure exposed during mammography, which is performed for early examination of breast cancer, has also been suggested as a cause of carcinogenesis in the past, and scattered rays generated during examination may cause unnecessary radiation exposure to surrounding organs. In this study, the Monte Carlo simulation was used to evaluate the human organ doses exposed during conventional mammography, and to estimate the dose reduction effect for each organ when using 3D printing materials for radiation protection by scattered rays. As a result of organ dose evaluation, the breast on the opposite side of the examination was about 22.0% of the breast on the test side and about 58.6% on the eye, which was highly influenced by the scattering-ray. When using the 3D printing shield to protect it, the breast on the opposite side of the test showed an effective dose reduction effect at a thickness of 1 mm.

A Study on Improving the Position Accuracy of the Magnetic North used in Surveillance Imaging Equipments (통합형 구조의 감시정찰 영상장비에서 자북의 위치 정확도 개선에 관한 연구)

  • Shin, Young-Don;Lee, Jae-Chon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.4
    • /
    • pp.219-228
    • /
    • 2013
  • The surveillance imaging equipments are functioning to observe the shape of the target in real time or to measure its location precisely. The roles of such equipments are becoming more important in today's weapon systems.The aforementioned imaging equipments can be classified based on the modes of operations such as fixed, installed on cars, or composite of those. Also, according to different concepts of sensor operation, a separate type uses independent housing for each sensor whereas in a composite type a set of multiple sensors are housed into a unit altogether. The sensors in general have magnetism, thereby introducing the possible negative effects, particularly in the composite types, in locating the reference position, which is carried out by the digital compass. The use of shielding material/housing could be an option but results in increased weight and reduced portability, restricting its use in composite type equipments. As such, the objective of this paper is to study on how to reduce such magnetic effects on the position location. To do so, in the absence of magnetic shielding, a variety of sensor positions were first modeled. By combing the result with the fact that the functions of PAN & Tilt are used in the equipments, a new position location algorithm is proposed. The use of the new algorithm can automate the position location process as compared to the manual process of the existing approach. In the algorithm developed, twelve locations are measured in connection with both the azimuth and elevation angles in comparison to the six locations alone around the azimuth angle. As a result, it turns out that the measurement range has been widened but the measurement time reduced. Also, note that the effect of errors the operators may make during measurement could be reduced.

A Study on the Development of Up-Converter for CATV Head/End Application (CATV Head/End용 Up-Converter의 개발)

  • 임경택
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 2002.06a
    • /
    • pp.62-68
    • /
    • 2002
  • In this paper, we have developed the Up-Convertor for CATV Head/End using 54∼750 MHz. We have individually designed and fabricated the main circuit of Up-converter such as Amplifier, frequency mixer, Voltage Controlled Oscillator(OSC), and we have realized the implementation for System Module in each circuit, so we have achieved a small size, light weight. and we have focused to have a shielding technique in high frequency bandwidth.

  • PDF

전자파 잔향실 및 야외시험장의 복사 방출 측정결과의 상관성 추출

  • 이중근
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.1
    • /
    • pp.31-37
    • /
    • 2002
  • 전자파 잔향실(Reverberating Shielded Enclosure)의 개념은 전자파 차폐실(Shielded Enclosure)에서 얻어진 측정결과를 개선하기 위하여 1968년도에 제안되었다. 이후 Reverberating 또는 Mode-Stirred Chamber는 EM Immunity 측정뿐만 아니라 EMI측정에서도 많이 적용되어 왔지만, 국제 표준 방식으로 적용되어 오지 못하다가 최근 EMI 복사 전력 측정 및 EM Immunity 측정시설로 유용하게 사용될 수 있다는 점이 부각되어 국제 표준 방식으로 적용하자는 분위기가 무르익어 이에 대한 활발한 논의가 계속되어 오고 있다. 이러한 전자파 잔향실을 이용하여 EMI 및 EMS 시험을 실시할 수 있는 방법을 규격화시키자는 제안이 '96년 프랑스 Mandelieu 국제 전자파 장해 특별위원회(CISPR:International Special Committee on Radio Interference)회의에서 검토된 후 '97년 일본 Yokosuka CISPR 회의에서 정식의제로 채택되었다. 이 안건에 대하여 대부분의 국가들이 제안 취지에 찬성하여 NWIP(New Work Item Proposal) 문서가 각국에서 회람되었다. 초기 전자파 잔향실은 전자파 장해 및 복사 내성 측정을 위한 대용시험 시설로서 1968년 미국 Mendes에 의해 전자파 차폐실 구조에 Stirrer를 이용하여 필드의 균일도를 확보할 수 있다는 전자파 잔향실 개념이 처음으로 제안되었다. 이후 이 분야의 연구는 미국 표준 기술 연구소(NIST: National Institute of Standard and Technology)등에서 연구가 활발히 진행되고 있으며, 국제 표준화 기구인 CISPR에서 전자파 장해 및 내성 시험을 위한 대용시험 시설로서 활용하기 위하여 규격 작업이 진행중에 있다. 또한 최근 전자파 장해 방지를 위한 규제 주파수가 1∼18㎓ 까지 확장됨에 따라 이 주파수 대역에서 시험장으로 활용할 수 있는 전자파 잔향실이 새롭게 부각되고 있다. 전자파 잔향실은 기본적으로 공진 모드를 활용하기 때문에 일정한 크기의 잔향실 내부에서 전자파 균일성을 확보할 수 있는 모드 수에 의해 하한 주파수가 결정되며 충분한 모드 분포상태에서 Stirrer를 사용하여 필드 경계를 이동시킴으로서 확률적으로 균일한 필드분포를 확보하게 된다. 주파수가 증가함에 따라 모드수는 증가하기 때문에 하한 주파수 이상의 대역에 대한 시험시설로 활용할 수 있으며, 특히 ㎓ 대역에서 사용하기에 적합한 대용시험시설이라고 볼 수 있다.

Study of External Radiation Expose Dose on Hands of Nuclear Medicine Workers (핵의학 종사자에서 손 부위의 외부 피폭선량 연구)

  • Park, Jun-Chul;Pyo, Sung-Jae
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.141-149
    • /
    • 2012
  • The aims of this study are to assess external radiation exposed doses of body and hands of nuclear medicine workers who handle radiation sources, and to measure radiation exposed doses of the hands induced by a whole body bone scan with high frequency and handling a radioactive sources like $^{99m}Tc$-HDP and $^{18}F$-FDG in the PET/CT examination. Skillful workers, who directly dispense and inject from radiation sources, were asked to wear a TLD on the chest and ring finger. Then, radiation exposed dose and duration exposed from daily radiation sources for each section were measured by using a pocket dosimeter for the accumulated external doses and the absorbed dose to the hands. In the survey of four medical institutions in Incheon Metropolitan City, only one of four institutions has a radiation dosimeter for local area like hands. Most of institutions uses radiation shielding devices for the purpose of protecting the body trunk, not local area. Even some institutions were revealed not to use such a shielding device. The exposed doses on the hands of nuclear medicine workers who directly handles radioactive sources were approximately twice as much as those on the body. The radiation exposure level for each section of the whole body bone scan with high frequency and that of the PET/CT examination showed that radiation doses were revealed in decreasing order of synthesis of radioactive medicine and installation to a dispensing container, dispensing, administering and transferring. Furthermore, there were statistically significant differences of radiation exposure doses of the hands before and after wearing a syringe shielder in administration of a radioactive sources. In this study, although it did not reach the permissible effective dose for nuclear medicine, the occupational workers were exposed by relatively higher dose level than the non-occupational workers. Therefore, the workers, who closely exposed to radioactive sources should be in compliance with safety management regulations, and take actions to maximally reduce locally exposed dose to hands monitoring with ring TLD.

A study of Brachytherapy for Intraocular Tumor (안구내 악성종양에 대한 저준위 방사선요법에 관한 연구)

  • Ji, Gwang-Su;Yu, Dae-Heon;Lee, Seong-Gu;Kim, Jae-Hyu;Ji, Yeong-Hun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.8 no.1
    • /
    • pp.19-27
    • /
    • 1996
  • I. Project Title A Study of Brachytherapy for intraocular tumor II. Objective and Importance of the project The eye enucleation or external-beam radiation therapy that has been commonly used for the treatment of intraocular tumor have demerits of visual loss and in deficiency of effective tumor dose. Recently, brachytherapy using the plaques containing radioisotope-now treatment method that decrease the demerits of the above mentioned treatment methods and increase the treatment effect-is introduced and performed in the countries, Our purpose of this research is to design suitable shape of plaque for the ophthalmic brachytherapy, and to measure absorbed doses of Ir-192 ophthalmic plaque and thereby calculate the exact radiation dose of tumor and it's adjacent normal tissue. III. Scope and Contents of the project In order to brachytherapy for intraocular tumor, 1. to determine the eye model and selected suitable radioisotope 2. to design the suitable shape of plaque 3. to measure transmission factor and dose distribution for custom made plaques 4. to compare with the these data and results of computer dose calculation models IV. Results and Proposal for Applications The result were as followed. 1. Eye model was determined as a 25mm diameter sphere, Ir-192 was considered the most appropriate as radioisotope for brachytherapy, because of the size, half, energy and availability. 2. Considering the biological response with human tissue and protection of exposed dose, we made the plaques with gold, of which size were 15mm, 17mm and 20mm in diameter, and 1.5mm in thickness. 3. Transmission factor of plaques are all 0.71 with TLD and film dosimetry at the surface of plaques and 0.45, 0.49 at 1.5mm distance of surface, respectively. 4. As compared the measured data for the plaque with Ir-192 seeds to results of computer dose calculation model by Gary Luxton et al. and CAP-PLAN (Radiation Treatment Planning System), absorbed doses are within ${\pm}10\%$ and distance deviations are within 0.4mm Maximum error is $-11.3\%$ and 0.8mm, respectively. As a result of it, we can treat the intraocular tumor more effectively by using custom made gold plaque and Ir-192 seeds.

  • PDF

Shielding for Critical Organs and Radiation Exposure Dose Distribution in Patients with High Energy Radiotherapy (고 에너지 방사선치료에서 환자의 피폭선량 분포와 생식선의 차폐)

  • Chu, Sung-Sil;Suh, Chang-Ok;Kim, Gwi-Eon
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 2002
  • High energy photon beams from medical linear accelerators produce large scattered radiation by various components of the treatment head, collimator and walls or objects in the treatment room including the patient. These scattered radiation do not provide therapeutic dose and are considered a hazard from the radiation safety perspective. Scattered dose of therapeutic high energy radiation beams are contributed significant unwanted dose to the patient. ICRP take the position that a dose of 500mGy may cause abortion at any stage of pregnancy and that radiation detriment to the fetus includes risk of mental retardation with a possible threshold in the dose response relationship around 100 mGy for the gestational period. The ICRP principle of as low as reasonably achievable (ALARA) was recommended for protection of occupation upon the linear no-threshold dose response hypothesis for cancer induction. We suggest this ALARA principle be applied to the fetus and testicle in therapeutic treatment. Radiation dose outside a photon treatment filed is mostly due to scattered photons. This scattered dose is a function of the distance from the beam edge, treatment geometry, primary photon energy, and depth in the patient. The need for effective shielding of the fetus and testicle is reinforced when young patients ate treated with external beam radiation therapy and then shielding designed to reduce the scattered photon dose to normal organs have to considered. Irradiation was performed in phantom using high energy photon beams produced by a Varian 2100C/D medical linear accelerator (Varian Oncology Systems, Palo Alto, CA) located at the Yonsei Cancer Center. The composite phantom used was comprised of a commercially available anthropomorphic Rando phantom (Phantom Laboratory Inc., Salem, YN) and a rectangular solid polystyrene phantom of dimensions $30cm{\times}30cm{\times}20cm$. the anthropomorphic Rando phantom represents an average man made from tissue equivalent materials that is transected into transverse 36 slices of 2.5cm thickness. Photon dose was measured using a Capintec PR-06C ionization chamber with Capintec 192 electrometer (Capintec Inc., Ramsey, NJ), TLD( VICTOREEN 5000. LiF) and film dosimetry V-Omat, Kodak). In case of fetus, the dosimeter was placed at a depth of loom in this phantom at 100cm source to axis distance and located centrally 15cm from the inferior edge of the $30cm{\times}30cm^2$ x-ray beam irradiating the Rando phantom chest wall. A acryl bridge of size $40cm{\times}40cm^2$ and a clear space of about 20 cm was fabricated and placed on top of the rectangular polystyrene phantom representing the abdomen of the patient. The leaf pot for testicle shielding was made as various shape, sizes, thickness and supporting stand. The scattered photon with and without shielding were measured at the representative position of the fetus and testicle. Measurement of radiation scattered dose outside fields and critical organs, like fetus position and testicle region, from chest or pelvic irradiation by large fie]d of high energy radiation beam was performed using an ionization chamber and film dosimetry. The scattered doses outside field were measured 5 - 10% of maximum doses in fields and exponentially decrease from field margins. The scattered photon dose received the fetus and testicle from thorax field irradiation was measured about 1 mGy/Gy of photon treatment dose. Shielding construction to reduce this scattered dose was investigated using lead sheet and blocks. Lead pot shield for testicle reduced the scatter dose under 10 mGy when photon beam of 60 Gy was irradiated in abdomen region. The scattered photon dose is reduced when the lead shield was used while the no significant reduction of scattered photon dose was observed and 2-3 mm lead sheets refuted the skin dose under 80% and almost electron contamination. The results indicate that it was possible to improve shielding to reduce scattered photon for fetus and testicle when a young patients were treated with a high energy photon beam.