• Title/Summary/Keyword: 차량 열관리 시스템

Search Result 14, Processing Time 0.023 seconds

A Study on Condition Assessment of the General National Road Bridge Deck (일반국도상 교량 바닥판의 상태 현황분석 연구)

  • Oh, Kwang Chin;Lee, Jun Gu;Shin, Ju Yeoul;Chang, Buhm Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.6
    • /
    • pp.93-101
    • /
    • 2012
  • Bridge deck has a role in a comfortable and safe passage of vehicles. At the same time, it preserves upper structure against the abrasion and shearing due to impact of traffic loads in bridges or has a role to protect the plate from off adverse effect of climatic process as rain, chemicals. Currently, the total number of inspected bridges is 6,248 in the general national road and to maintain effectively, Introduction of GPR system mounted in the vehicle has been considered. In this research, the comparison and analysis of bridge deck condition on general national road has been performed with major variations of superstructure type, span lengths, located region and ages by using 'the current status of road bridge and tunnel' that is provided by MLTM(Ministry of Land, Transport and Maritime Affairs). As a result, Condition assessment grade, superstructure type, age and length were derived as a major factor to determine priority for the condition assessment.

Development of Battery Management System for Electric Vehicle Applications of Ni/MH Battery

  • Jung Do Yang;Lee Baek Haeng;Kim Sun Wook
    • Journal of the Korean Electrochemical Society
    • /
    • v.4 no.4
    • /
    • pp.152-159
    • /
    • 2001
  • Electric vehicle performance is very dependent on traction batteries. For developing the electric vehicles with high performance and good reliability, the traction batteries have to be managed to get maximum performance under various operating conditions. The enhancement of the battery performance can be accomplished by implementing battery management system (BMS) that plays important roles of optimizing the control mechanism of charge and discharge of the batteries as well as monitoring battery status. In this study the battery management system has been developed for maximizing the use of Ni/MH batteries in electric vehicle. This system provides several tasks: the control of charging and discharging, overcharge and over-discharge protection, the calculation and display of state of charge, safety and thermal management. The BMS was installed in and tested using the DEV5-5 electric vehicle developed by Daewoo Motor Co. and Institute for Advanced Engineering in Korea. The 18 modules of Panasonic Ni/MH battery, 12 V-95 Ah, were used in the DEV5-5. The high accuracy within the range of $3\%$ and the good reliability were shown in the test results. The BMS can also improve the performance and cycle life of Ni/MH battery pack as well as the reliability and safety of the electric vehicles (EV).

Development of the Calorimeter to Measure Heat Rate Generated from Battery for EV & HEV (전기자동차용 축전지의 발열량 측정을 위한 열용량계 개발)

  • Yang Cheol-Nam;Park Seong-Yong
    • Journal of the Korean Electrochemical Society
    • /
    • v.2 no.4
    • /
    • pp.218-220
    • /
    • 1999
  • The performance of the Electric Vehicle and Hybrid Electric Vehicle depends on that of the battery pack composed of series connected batteries. And thermal property is one of the main factors which decide the performance of the battery pack. So heat generation rate from the battery under the various driving mode must be measured as precise as possible because thermal characteristics of the battery affect the driving performance and battery pack's life cycle. Besides, to design and develop the battery thermal management system for the EV and HEV, the measurements of the thermal properties of the batteries are needed. However, the established calorimeter is not adequate to test an EV's battery because its cavity is too small to accommodate the EV's battery. Therefore we developed the calorimeter to test the thermal property of the EV's battery. Its cavity size is 120mm long, 75mm wide and 200mm high. The calorimeter is calibrated by the dummy cell which generates the heat rate from zero to 200W. The measuring accuracy of the calorimeter is within $2\%$ and its voltage stability is 2.5mV in the constant temperature bath.

Correlation analysis of pollutants using IoT technology in LID facilities (LID 시설 내 IoT 기술을 활용한 오염물질 상관성 분석)

  • Jeon, Minsu;Choi, Hyeseon;kevin, Geronimo Franz;Reyes, N.J.DG.;Kim, Leehyung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.453-453
    • /
    • 2021
  • 도시지역 비점오염원관리, 물순환 회복, 침투 및 증발산량 증가, 열섬현상 저감을 위한 주요한 방안으로 저영향개발(low impact development, LID)과 그린인프라 기법의 적용되고 있다. LID 시설은 소규모 분산형 시설로써 넓은 지역에 많고 다양한 시설들이 적용되어 시설의 개수가 많으며, 수질 및 토양 내 기성제품에 대한 센서들의 가격은 고가로 형성되어 있어 기기의 경제성 및 유지관리 등 적용하는데 제한적이다. 따라서 과거 모니터링 자료를 기반으로 오염물질들과의 상관성 분석을 통하여 계측이 어려운 항목들을 계측가능한 항목들로부터 예측 가능하며, 선정된 항목들에 대한 비용효율적인 센서를 개발하여 실시간 LID 모니터링이 가능한 비용효율적 모니터링을 개발하였다. 공주대학교 천안캠퍼스의 LID 시설들은 2013년에 조성되어 현재까지 시설이 운영되고 있으며, 5년이상의 과거 강우시 모니터링 자료들을 이용하여 오염물질 상관성 분석을 수행가능 하기에 대상지로 선정하였다. 오염물질 상관성 분석은 2013년부터 2017년도에 침투도랑에서 수행된 강우시 모니터링 자료를 활용하여 각 오염물질들의 상관성을 분석을 수행하였다. 침투도랑 내 유입되는 평균 유입수는 TSS 286.1±318.3 mg/L, BOD 22.6±39.5 mg/L, TN 8.96±5.85 mg/L, TP 1.01±1.11 mg/L로 나타났다. 겨울철에 비해 여름철에서의 오염물질의 유입농도가 높은 것으로 분석되었다. 이는 여름철 고온건조로 인한 노면 내 차량의 주행으로 인한 중금속, 폐타이어 등과 장마철 강우 시 유출된 토사로 인하여 유입수의 농도가 높은 것으로 분석되었다. 오염물질 부하량은 TSS와 COD 0.66으로 유의성이 높은 것으로 나왔으며, COD와 TSS, TP, TN 등 유의성이 높은 것으로 분석되었다. Arduino와 Raspberry PI를 활용하여 저비용 센서와 LTE 모뎀통신과 데이터 베이스 연결하여 개발된 프로그램을 통해서 무선으로 LID 시설에 대한 모니터링을 침투화분2와 식생체류지에 조성하였다. 전력공급이 어려운 식생체류지의 경우 태양열(Solar system) 시스템과 보조 전력 배터리를 조성하여 장마철이나 장기적인 악천후로 인한 전력을 생산하지 못할 경우 보조전력배터리에서 전력을 제공하여 지속적인 모니터링이 이루어지도록 설계하였다. 토양함수량, 토양온도와 Conductivity 등 3종류의 센서를 적용하였으며, 프로그램은 현재 2단계를 통한 2차수정을 통하여 프로그램을 구축하였다. 오차, 오작동, 계측값에 대한 검·보정 작업이 필요하다. 또한 대기자료의 구축을 통해 보다 토양과 LID 시설에 대한 영향분석이 필요한 것으로 사료된다.

  • PDF