• Title/Summary/Keyword: 차단성능

Search Result 891, Processing Time 0.023 seconds

A COVID-19 Diagnosis Model based on Various Transformations of Cough Sounds (기침 소리의 다양한 변환을 통한 코로나19 진단 모델)

  • Minkyung Kim;Gunwoo Kim;Keunho Choi
    • Journal of Intelligence and Information Systems
    • /
    • v.29 no.3
    • /
    • pp.57-78
    • /
    • 2023
  • COVID-19, which started in Wuhan, China in November 2019, spread beyond China in 2020 and spread worldwide in March 2020. It is important to prevent a highly contagious virus like COVID-19 in advance and to actively treat it when confirmed, but it is more important to identify the confirmed fact quickly and prevent its spread since it is a virus that spreads quickly. However, PCR test to check for infection is costly and time consuming, and self-kit test is also easy to access, but the cost of the kit is not easy to receive every time. Therefore, if it is possible to determine whether or not a person is positive for COVID-19 based on the sound of a cough so that anyone can use it easily, anyone can easily check whether or not they are confirmed at anytime, anywhere, and it can have great economic advantages. In this study, an experiment was conducted on a method to identify whether or not COVID-19 was confirmed based on a cough sound. Cough sound features were extracted through MFCC, Mel-Spectrogram, and spectral contrast. For the quality of cough sound, noisy data was deleted through SNR, and only the cough sound was extracted from the voice file through chunk. Since the objective is COVID-19 positive and negative classification, learning was performed through XGBoost, LightGBM, and FCNN algorithms, which are often used for classification, and the results were compared. Additionally, we conducted a comparative experiment on the performance of the model using multidimensional vectors obtained by converting cough sounds into both images and vectors. The experimental results showed that the LightGBM model utilizing features obtained by converting basic information about health status and cough sounds into multidimensional vectors through MFCC, Mel-Spectogram, Spectral contrast, and Spectrogram achieved the highest accuracy of 0.74.

Study on Nozzle Type and Proper Discharge Pressure of Sprayer for Vehicle Disinfecting System (차량소독장치용 노즐형태와 분무기의 적정토출압력에 관한 연구)

  • Lim, Young-Il;Chang, Dong-Il;Kim, Jeong-Chul;Park, Dong-Suk;Lee, Seung-Joo;Kang, Beom-Sun;Kim, Suk;Gutierrez, Winson M.;Lee, Tae-Hoon;Choi, Chung-Heon;Chang, Hong-Hee
    • Journal of agriculture & life science
    • /
    • v.50 no.3
    • /
    • pp.119-127
    • /
    • 2016
  • The current disinfection method of vehicles being applied in South Korea has various shortcomings. So, the epidemic has generated continuously at livestock farms. It is very important to develop an effective disinfection system for reduction of the epidemic. And various basic data is required for this development. Therefore, this study was performed to identify the nozzle type and proper discharge pressure of sprayers. The experiment was conducted from January 10, 2012 until February 28, 2012. All the performance measurement experiments were repeated five times. The subjects of experiment were the A, B and C company's products. The sprayed capacity, angle of spray and the covering area ratio were measured for each product. As a result, the sprayed capacity, angle of spray and the covering area ratio were increased as the discharge pressure of the sprayer was increased. In conclusion, the conical shaped of the nozzle is considered more appropriate than V-shaped, and the proper discharge pressure is expected to be at least 20kg/㎠.

Animal Infectious Diseases Prevention through Big Data and Deep Learning (빅데이터와 딥러닝을 활용한 동물 감염병 확산 차단)

  • Kim, Sung Hyun;Choi, Joon Ki;Kim, Jae Seok;Jang, Ah Reum;Lee, Jae Ho;Cha, Kyung Jin;Lee, Sang Won
    • Journal of Intelligence and Information Systems
    • /
    • v.24 no.4
    • /
    • pp.137-154
    • /
    • 2018
  • Animal infectious diseases, such as avian influenza and foot and mouth disease, occur almost every year and cause huge economic and social damage to the country. In order to prevent this, the anti-quarantine authorities have tried various human and material endeavors, but the infectious diseases have continued to occur. Avian influenza is known to be developed in 1878 and it rose as a national issue due to its high lethality. Food and mouth disease is considered as most critical animal infectious disease internationally. In a nation where this disease has not been spread, food and mouth disease is recognized as economic disease or political disease because it restricts international trade by making it complex to import processed and non-processed live stock, and also quarantine is costly. In a society where whole nation is connected by zone of life, there is no way to prevent the spread of infectious disease fully. Hence, there is a need to be aware of occurrence of the disease and to take action before it is distributed. Epidemiological investigation on definite diagnosis target is implemented and measures are taken to prevent the spread of disease according to the investigation results, simultaneously with the confirmation of both human infectious disease and animal infectious disease. The foundation of epidemiological investigation is figuring out to where one has been, and whom he or she has met. In a data perspective, this can be defined as an action taken to predict the cause of disease outbreak, outbreak location, and future infection, by collecting and analyzing geographic data and relation data. Recently, an attempt has been made to develop a prediction model of infectious disease by using Big Data and deep learning technology, but there is no active research on model building studies and case reports. KT and the Ministry of Science and ICT have been carrying out big data projects since 2014 as part of national R &D projects to analyze and predict the route of livestock related vehicles. To prevent animal infectious diseases, the researchers first developed a prediction model based on a regression analysis using vehicle movement data. After that, more accurate prediction model was constructed using machine learning algorithms such as Logistic Regression, Lasso, Support Vector Machine and Random Forest. In particular, the prediction model for 2017 added the risk of diffusion to the facilities, and the performance of the model was improved by considering the hyper-parameters of the modeling in various ways. Confusion Matrix and ROC Curve show that the model constructed in 2017 is superior to the machine learning model. The difference between the2016 model and the 2017 model is that visiting information on facilities such as feed factory and slaughter house, and information on bird livestock, which was limited to chicken and duck but now expanded to goose and quail, has been used for analysis in the later model. In addition, an explanation of the results was added to help the authorities in making decisions and to establish a basis for persuading stakeholders in 2017. This study reports an animal infectious disease prevention system which is constructed on the basis of hazardous vehicle movement, farm and environment Big Data. The significance of this study is that it describes the evolution process of the prediction model using Big Data which is used in the field and the model is expected to be more complete if the form of viruses is put into consideration. This will contribute to data utilization and analysis model development in related field. In addition, we expect that the system constructed in this study will provide more preventive and effective prevention.

Efficacy of a Protective Grass Shield in Reduction of Radiation Exposure Dose During Interventional Radiology (방사선학적 중재적 시술시 납유리의 방사선 방어효과에 관한 연구)

  • Jang, Young-Ill;Song, Jong-Nam;Kim, Young-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.303-308
    • /
    • 2011
  • Background/Aims : The increasing use of diagnostic and therapeutic interventional radiology calls for greater consideration of radiation exposure risk to radiologist and radiological technician, and emphasizes the proper system of radiation protection. This study was designed to assess the effect of a protective grass shield. Methods : A protective grass was following data depth, 0.8 cm; width, 100 cm; length, 100 cm, lead equivalent, 1.6 mmPb. The protective shield was located between the patient and the radiologist. Thirty patients (13 male and 17 female) undergoing interventional radiology between September 2010 and December 2010 were selected for this study. The dose of radiation exposure was recorded with or without the protective grass shield at the level of the head, chest, and pelvis. The measurement was made at 50 cm and 150 cm from the radiation source. Results : The mean patient age was 69 years. The mean patient height and weight was $159.7{\pm}6.7$ cm and $60.3{\pm}5.9$ kg, respectively. The mean body mass index (BMI) was $20.5{\pm}3.0$ kg/m2. radiologists received $1530.2{\pm}550.0$ mR/hr without the protective lead shield. At the same distance, radiation exposure was significantly reduced to $50.3{\pm}85.2$ mR/hr with the protective lead shield (p-value<0.0001). The radiation exposure to radiologist and radiological technician was significantly reduced by the use of a protective lead shield (p value <0.0001). The amount of radiation exposure during interventional radiology was related to the patient' BMI (r=0.749, p=0.001). Conclusions : This protective shield grass is effective in protecting radiologist and radiological technician from radiation exposure.

SVC Based Multi-channel Transmission of High Definition Multimedia and Its Improved Service Efficiency (SVC 적용에 의한 다매체 멀티미디어 지원 서비스 효율 향상 기법)

  • Kim, Dong-Hwan;Cho, Min-Kyu;Moon, Seong-Pil;Lee, Jae-Yeal;Jun, Jun-Gil;Chang, Tae-Gyu
    • Journal of IKEEE
    • /
    • v.15 no.2
    • /
    • pp.179-189
    • /
    • 2011
  • This paper presents an SVC based multi-channel transmission technique. Transmission of high definition multimedia and its service efficiency can be significantly improved by the proposed method. In this method, the HD stream is divided into the two layer streams, i.e., a base layer stream and an enhancement layer stream. The divided streams are transmitted through a primary channel and an auxiliary channel, respectively. The proposed technique provides a noble mode switching technique which enables a seamless service of HD multimedia even under the conditions of abrupt and intermittent deterioration of the auxiliary channel. When the enhancement layer stream is disrupted by the channel monitoring in the mode switching algorithm, the algorithm works further to maintain the spatial and time resolution of the HD multimedia by upsampling and interpolating the base layer stream, consequently serving for the non disrupted play of the media. Moreover, the adoption of an adaptive switching algorithm significantly reduces the frequency of channel disruption avoiding the unnecessary switching for the short period variations of the channel. The feasibility of the proposed technique is verified through the simulation study with an example application to the simultaneous utilization of both Ku and Ka bands for HD multimedia broadcasting service. The rainfall modeling and the analysis of the satellite channel attenuation characteristics are performed to simulate the quality of service performance of the proposed HD broadcasting method. The simulation results obtained under a relatively poor channel (weather) situations show that the average lasting period of enhancement layer service is extended from 9.48[min] to 23.12[min] and the average switching frequency is reduced from 3.84[times/hour] to 1.68[times/hour]. It is verified in the satellite example that the proposed SVC based transmission technique best utilizes the Ka band channel for the service of HD broadcasting, although it is characterized by its inherent weather related poor reliability causing severe limitations in its independent application.

Nano-mechanical Properties of Nanocrystal of HfO2 Thin Films for Various Oxygen Gas Flows and Annealing Temperatures (RF Sputtering의 증착 조건에 따른 HfO2 박막의 Nanocrystal에 의한 Nano-Mechanics 특성 연구)

  • Kim, Joo-Young;Kim, Soo-In;Lee, Kyu-Young;Kwon, Ku-Eun;Kim, Min-Suk;Eum, Seoung-Hyun;Jung, Hyun-Jean;Jo, Yong-Seok;Park, Seung-Ho;Lee, Chang-Woo
    • Journal of the Korean Vacuum Society
    • /
    • v.21 no.5
    • /
    • pp.273-278
    • /
    • 2012
  • Over the last decade, the hafnium-based gate dielectric materials have been studied for many application fields. Because these materials had excellent behaviors for suppressing the quantum-mechanical tunneling through the thinner dielectric layer with higher dielectric constant (high-K) than $SiO_2$ gate oxides. Although high-K materials compensated the deterioration of electrical properties for decreasing the thickness of dielectric layer in MOSFET structure, their nano-mechanical properties of $HfO_2$ thin film features were hardly known. Thus, we examined nano-mechanical properties of the Hafnium oxide ($HfO_2$) thin film in order to optimize the gate dielectric layer. The $HfO_2$ thin films were deposited by rf magnetron sputter using hafnium (99.99%) target according to various oxygen gas flows. After deposition, the $HfO_2$ thin films were annealed after annealing at $400^{\circ}C$, $600^{\circ}C$ and $800^{\circ}C$ for 20 min in nitrogen ambient. From the results, the current density of $HfO_2$ thin film for 8 sccm oxygen gas flow became better performance with increasing annealing temperature. The nano-indenter and Weibull distribution were measured by a quantitative calculation of the thin film stress. The $HfO_2$ thin film after annealing at $400^{\circ}C$ had tensile stress. However, the $HfO_2$ thin film with increasing the annealing temperature up to $800^{\circ}C$ had changed compressive stress. This could be due to the nanocrystal of the $HfO_2$ thin film. In particular, the $HfO_2$ thin film after annealing at $400^{\circ}C$ had lower tensile stress, such as 5.35 GPa for the oxygen gas flow of 4 sccm and 5.54 GPa for the oxygen gas flow of 8 sccm. While the $HfO_2$ thin film after annealing at $800^{\circ}C$ had increased the stress value, such as 9.09 GPa for the oxygen gas flow of 4 sccm and 8.17 GPa for the oxygen gas flow of 8 sccm. From these results, the temperature dependence of stress state of $HfO_2$ thin films were understood.

The Acceptance Testing of 5 Mega Pixels Primary Electronic Display Devices and the Study of Quality Control Guideline Suitable for Domestic Circumstance (5 Mega 화소 진단용 전자표시장치 인수검사 및 국내 실정에 적합한 정도관리 가이드라인 연구)

  • Jung, Hai-Jo;Kim, Hee-Joung;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.98-106
    • /
    • 2007
  • In June 2005, Yonsei University Medical Center, Severance Hospital upgraded a full-PACS system by adding twenty (5 mega pixels) Totoku ME511L flat panel LCD display devices for diagnostic interpretation purposes. Here we report upon the quantitative (or visual) acceptance testing of the twenty Totoku ME511L display devices for reflection, luminance response, luminance spatial dependency, resolution, noise, veiling glare, and display chromaticity based on AAPM TG 18 report. The tools used in the tests included a telescopic photometer, which was used as a colorimeter, illuminance meter, light sources for reflection assessment, light-blocking devices, and digital TG18 test patterns. For selected 8 flat panel displays, mean diffuse reflection coefficient ($R_d$) was $0.019{\pm}0.02sr^{-1}$. In the luminance response test, luminance ratio (LR), maximum luminance difference ($L_{max}$), and deviation of contrast response were $550{\pm}100,\;2.0{\pm}1.9%\;and\;5.8{\pm}1.8%$, respectively. In the luminance uniformity test, maximum luminance deviation was $14.3{\pm}5.5%$ for the 10% luminance of the TG18-UNL10 test pattern. In the resolution test with luminance measurement method, percent luminance (${\Dalta}L$) at the center was $0.94{\pm}0.64%$. In all cases of noise testing, rectangular target In every square in the three quadrants was visible and all 15 targets except the smallest one in the every corner pattern and the center pattern. The glare ratio (GR) was $12,346{\pm}1,995$. The color uniformity, (u',v'), was $0.0025{\pm}0.0008$. Also, the research results of qualify control guideline of primary disply devices suitable for domestic circumstance are presented All test results are in-line with the criteria recommended by AAPM TG18 report and are thus fully acceptable for diagnostic image interpretation. As a result, the acceptance testing schedule described provides not only an acceptance standard but also guidelines for quality control, optimized viewing conditions, and a means for determining the upgrading time of LCD display devices for diagnostic interpretation.

  • PDF

A Study on the Nutrition Contents and Blood Glucose Response Effect of Diabetic-Oriented Convenience Food prepared Medicinal Plants and Chicken (생약재와 닭고기를 이용하여 개발된 편의 당뇨식사의 영양성분 및 혈당반응)

  • 한종현;박성혜
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.12 no.2
    • /
    • pp.91-99
    • /
    • 2002
  • This study was carried out to develop a diabetic-oriented convenience flood using 7 medicinal plants (Schisandra chinensis, Coix lachryma-jobi, Dioscorea batatas, Ophipogon japonicus, Lyicium chinense, Houttuynia cordata, Polygonatum sibiricum) and chicken. Portion size was 310g, total calorie was 551.6 kcal and carbohydrate, lipid and protein were consisted of 53.0%, 20.9% and 26.1%, respectively. Calcium, zinc and iron content were 268.9mg, 5.4mg and 6.1mg, respectively. Crude fiber content was 22.9g. In sensory evaluation, the scores of taste, color, texture and overall acceptability were higher than normal diabetic meal. Hypoglycemic effect of the device meal for diabetic persons was excellent compared to that of normal diabetic meal. The above results indicate that the 7 medicinal plants can be used as functional ingredients fur diabetic-oriented convenience flood industry. Also, device meal can be used as ready-prepared food for weight control.

  • PDF

Investigation of Viscoelastic Properties of EPDM/PP Thermoplastic Vulcanizates for Reducing Innerbelt Weatherstrip Squeak Noise of Electric Vehicles (전기차 인너벨트 웨더스트립용 EPDM/PP Thermoplastic Vulcanizates 재료설계인자에 따른 점탄성과 글라스 마찰 소음 상관관계 연구)

  • Cho, Seunghyun;Yoon, Bumyong;Lee, Sanghyun;Hong, Kyoung Min;Lee, Sang Hyun;Suhr, Jonghwan
    • Composites Research
    • /
    • v.34 no.3
    • /
    • pp.192-198
    • /
    • 2021
  • Due to enormous market growing of electric vehicles without combustion engine, reducing unwanted BSR (buzz, squeak, and rattle) noise is highly demanded for vehicle quality and performance. Particularly, innerbelt weatherstrips which not only block wind noise, rain, and dust from outside, but also reduce noise and vibration of door glass and vehicle are required to exhibit high damping properties for improved BSR performance of the vehicle. Thermoplastic elastomers (TPEs), which can be recycled and have lighter weight than thermoset elastomers, are receiving much attention for weatherstrip material, but TPEs exhibit low material damping and compression set causing frictional noise and vibration between the door glass and the weatherstrip. In this study, high damping EPDM (ethylene-propylene-diene monomer)/PP (polypropylene) thermoplastic vulcanizates (TPV) were investigated by varying EPDM/PP ratio and ENB (ethylidene norbornene) fraction in EPDM. Viscoelastic properties of TPV materials were characterized by assuming that the material damping is directly related to the viscoelasticity. The optimum material damping factor (tanδ peak 0.611) was achieved with low PP ratio (14 wt%) and high ENB fraction (8.9 wt%), which was increased by 140% compared to the reference (tanδ 0.254). The improved damping is believed due to high fraction of flexible EPDM chains and higher interfacial slippage area of EPDM particles generated by increasing ENB fraction in EPDM. The stick-slip test was conducted to characterize frictional noise and vibration of the TPV weatherstrip. With improved TPV material damping, the acceleration peak of frictional vibration decreased by about 57.9%. This finding can not only improve BSR performance of electric vehicles by designing material damping of weatherstrips but also contribute to various structural applications such as urban air mobility or aircrafts, which require lightweight and high damping properties.

Development of Korean Version of Heparin-Coated Shunt (헤파린 표면처리된 국산화 혈관우회도관의 개발)

  • Sun, Kyung;Park, Ki-Dong;Baik, Kwang-Je;Lee, Hye-Won;Choi, Jong-Won;Kim, Seung-Chol;Kim, Taik-Jin;Lee, Seung-Yeol;Kim, Kwang-Taek;Kim, Hyoung-Mook;Lee, In-Sung
    • Journal of Chest Surgery
    • /
    • v.32 no.2
    • /
    • pp.97-107
    • /
    • 1999
  • Background: This study was designed to develop a Korean version of the heparin-coated vascular bypass shunt by using a physical dispersing technique. The safety and effectiveness of the thrombo-resistant shunt were tested in experimental animals. Material and Method: A bypass shunt model was constructed on the descending thoracic aorta of 21 adult mongrel dogs(17.5-25 kg). The animals were divided into groups of no-treatment(CONTROL group; n=3), no-treatment with systemic heparinization(HEPARIN group; n=6), Gott heparin shunt (GOTT group; n=6), or Korean heparin shunt(KIST group; n=6). Parameters observed were complete blood cell counts, coagulation profiles, kidney and liver function(BUN/Cr and AST/ ALT), and surface scanning electron microscope(SSEM) findings. Blood was sampled from the aortic blood distal to the shunt and was compared before the bypass and at 2 hours after the bypass. Result: There were no differences between the groups before the bypass. At bypass 2 hours, platelet level increased in the HEPARIN and GOTT groups(p<0.05), but there were no differences between the groups. Changes in other blood cell counts were insignificant between the groups. Activated clotting time, activated partial thromboplastin time, and thrombin time were prolonged in the HEPARIN group(p<0.05) and differences between the groups were significant(p<0.005). Prothrombin time increased in the GOTT group(p<0.05) without having any differences between the groups. Changes in fibrinogen level were insignificant between the groups. Antithrombin III levels were increased in the HEPARIN and KIST groups(p<0.05), and the inter-group differences were also significant(p<0.05). Protein C level decreased in the HEPARIN group(p<0.05) without having any differences between the groups. BUN levels increased in all groups, especially in the HEPARIN and KIST groups(p<0.05), but there were no differences between the groups. Changes of Cr, AST, and ALT levels were insignificant between the groups. SSEM findings revealed severe aggregation of platelets and other cellular elements in the CONTROL group, and the HEPARIN group showed more adherence of the cellular elements than the GOTT or KIST group. Conclusion: Above results show that the heparin-coated bypass shunts(either GOTT or KIST) can suppress thrombus formation on the surface without inducing bleeding tendencies, while systemic heparinization(HEPARIN) may not be able to block activation of the coagulation system on the surface in contact with foreign materials but increases the bleeding tendencies. We also conclude that the thrombo-resistant effects of the Korean version of heparin shunt(KIST) are similar to those of the commercialized heparin shunt(GOTT).

  • PDF