• Title/Summary/Keyword: 차단성능

Search Result 891, Processing Time 0.024 seconds

An Ultra-thin IR Cut-off Filter Based on Nanostructures (나노구조 기반 초박형 적외선 차단 필터)

  • Hyundo Yang;Jong-Kwon Lee
    • Korean Journal of Optics and Photonics
    • /
    • v.35 no.1
    • /
    • pp.24-29
    • /
    • 2024
  • We propose a hyperbolic metastructure based on a nanopatterned metal (Ag)-dielectric (PDMS) multilayer and report on its performance in an infrared (IR) cut-off filter for imaging devices. By optimizing the size of the square-shaped Ag nanopattern and the thickness of PDMS surrounding the Ag nanopattern, the proposed IR cut-off filter blocks 99% of light in the 0.70-1.01 ㎛ wavelength band while maintaining a high transmittance of over 94% in the visible region. Here, the cut-off wavelength band starts at a region above the epsilon-near-zero wavelength of the hyperbolic metastructure and ends at the point where plasmonic absorption appears strongly. It is observed that transmittance in the wavelength region longer than the IR cut-off band increases again due to plasmonic coupling among horizontally adjacent Ag nanopatterns. This metastructure can improve the performance of IR-blocking filters as well as allow it to be manufactured ultra-thin, which is applicable to various planar optical elements and integrated optical components.

Arc Modeling and Magnetic Field Analysis of Vacuum Interrupter (진공차단부 아크 모델링 및 자계해석)

  • Choi, M.J.;Kim, J.S.;Song, T.H.;Seok, B.Y.;Park, I.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.629-631
    • /
    • 2001
  • 중저압 분야에서 가장 많이 사용되는 차단기는 진공차단기이다. 진공차단기는 $SF_6$에 비하여 간단하며, 아크소호 능력 또한 뛰어나다. 이런 진공차단기에서 차단성능에 가장 중요한 부분이 진공차단부이다. 본 논문에서는 constricted arc와 diffuse arc에 관하여 서술하였으며, contrate type 진공차단부의 다양한 형상변경에 따른 직교자계와 축자계에 대한 3차원 전자계 해석을 수행하였다. 3차원 전자계해석으로 얻어진 결과는 새로운 진공차단부 개발에 커다란 도움이 될 것으로 사료된다.

  • PDF

Development of Current Limiting COS Fuse Link with Improved Overcurrent and Protection Coordination performance (과전류 차단과 보호협조 성능이 향상된 한류형 COS 퓨즈링크 개발)

  • Kim, Youn-Hyun;Kim, Young-Ju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.129-136
    • /
    • 2020
  • A Cut Out Switch (COS) is used for line protection and pole transformer protection in power systems. The COS used to protect the pole transformer is installed on the power side of the pole transformer to protect the electric equipment from fault currents. The COS is composed largely of a body and a fuse holder, and when the fault current is energized, the element of the fuse link in the fuse holder is melted to block the fault current. The arc generated when the COS fuse link is blown causes fire and noise, causing discomfort to residents in the surrounding area, and the arc flame can cause secondary damage to the peripheral device. In this study, a current-limiting COS fuse with improved overcurrent blocking performance rather than explosion type was developed to solve the arc and noise problems during COS operation. The overcurrent breaking performance of the current-limiting COS improves the reliability by developing a striker and COS fuse bracket. In addition, this study aimed to verify the performance of the developed current-limiting COS fuse through a test at an authorized institution.

Development for Penetrative Performance Improving Agent to In Prevent Deterioration of Concrete Structures (콘크리트 구조물의 내구성능 저하를 방지하는 침투형 성능개선제 개발)

  • Ryu Gum-Sung;Koh Kyoung-Taek;Kim Sung-Wook;Kim Do-Gyeum
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.4 s.88
    • /
    • pp.489-498
    • /
    • 2005
  • Recently, the deterioration of concrete structures have been increased by the damage from salt, carbonization, freezing & thawing and the others. Therefore, the measures for the deterioration of concretes have been taken. Among them, it has been often used that surface treatment which cut off the deterioration factors of durability by protecting the surface of concrete. The water proof and repair materials for concrete mainly use organic materials such as epoxy, these materials excel in intial bonding force and resistance to chemical agents. But they cause difference in the modulus of elasticity and the rate of shrinkage and expansion of concrete, and thus result in such problems as scaling and spatting in the progress of time. Therefore in this study it develop the performance Improving agent of concrete surface that can block a deterioration cause such as $CO_2$ gas, chloride ion and water from the outside and enhance waterproofing ability by reinforcing the concrete surface when applying it to concrete structures.

Analysis on Effects of The Firewall on Networks (네트워크 상에서의 침입차단시스템 영향력 분석)

  • 정선이;박정은;유수연;장성은;채기준;노병규
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.10 no.4
    • /
    • pp.95-105
    • /
    • 2000
  • The Firewall is needed in order to protect communication networks from ill effects of informatization such as information leakage, destruction, forgery and virus. To take an advantage of the firewall, the security manager must understand the effects that it can have on the network. There airs, however, no tools available to evaluate the performance of the firewall. In this paper, we study the effect of the firewall by putting various kinds of traffic into the actual network. Also, using COMNET- III, we model two networks with and without the firewall. And we analyze the effects under the various network envion-ments.

Long-Term Performance of Geotextile and Geomembranes by Installation Damage (시공 시 손상에 의한 지오텍스타일 및 지오멤브레인의 장기성능)

  • 전한용;목문성;류원석;이준석;홍상진
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2003.04a
    • /
    • pp.235-238
    • /
    • 2003
  • 폐기물 매립시스템은 크게 폐기물의 토양으로의 유출에 의한 오염방지를 위한 lining system과 폐기물에서 발생하는 가스의 방출차단과 빗물의 매립시스템으로의 침투방지를 위한 covering system으로 나뉘어진다. Lining system은 폐기물 하부에 차수층, 침출수 배수층, 침출수 차단층과 차수재 보호층 순으로 구성되며, covering system은 폐기물 상부에 집수관을 설치한 후 중간 복토층을 둔 후, 가스 차단층, 봉합층, 배수장치와 보호층 순으로 구성되어진다. (중략)

  • PDF

향상된 DC Breaker에 관한 연구

  • Kim, Geon
    • Proceeding of EDISON Challenge
    • /
    • 2017.03a
    • /
    • pp.473-476
    • /
    • 2017
  • 본 논문은 직류송전에서 송전선에 문제가 발생했을 때 생기는 고장전류를 제거하는 회로인 DC Breaker의 성능을 향상시킨 회로에 대한 것이다. 기존의 DC Breaker는 차단효율이 좋지 않고, 차단시간 또한 길다는 단점들이 문제가 되었는데, 이를 중앙 인덕터를 통해, 고장전류의 크기를 감소시키고, 커패시터 스위칭을 통해 차단시간을 줄이는 등의 방법을 이용하여, 효율을 개선하였다. 그리고 이 개선된 DC Breaker가 DC 고전압 전력수송에 꼭 필요하다는 것을 실험을 통해 그 실용성을 검증하였다.

  • PDF

Development of Pre-breakdown Partial Discharge Detection Method for Explanation of the Cause of EHV XLPE Cable Joint Breakdown (절연파괴 원인규명을 위한 Pre-breakdown PD 검출기술 개발)

  • Kim, Choong-Sik;Kim, Young-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2008.10a
    • /
    • pp.85-86
    • /
    • 2008
  • 케이블의 원가절감을 위해 절연체의 절연두께를 줄이거나 초초고압화가 되어 갈수록 절연성능의 신뢰성 향상이 한층 요구되고 있다. 이를 위해 케이블 및 접속함의 절연체 내에 각종의 결함이 어느 정도 절연성능을 떨어뜨리는지 정량적으로 파악하여 개선할 필요가 있다. 또한 완제품 내 잔족하고 있는 이물의 종류 및 위치를 알 수 있으면 생산공정 내에서 이물 유입 경로를 파악하여 이물이 유입되는 것을 차단할 수 있다. AC내전압 파괴시험을 수행할 때 설계치 보다 저전계에서 파괴될 경우 파괴공을 조사하여 원인을 규명하고자 하지만 국부적인 결함으로 인한 파괴는 결함부를 소실시키기 때문에 파괴공 및 주위의 절연체를 현미경으로 관찰하여도 찾기가 어렵다. 따라서, 전원을 고속으로 차단하여 결함부가 완전히 소손되는 것을 막고 PD발생 위치를 추정하여 결함을 확인하는 방법이 요구 되어진다. 이러한 시험 방법을 전구차단법 이라고 하며, 고도의 PD측정기술과 판정기술이 필요한 종합적인 기술이다. 본 논문에서는 PPD 기술의 핵심인 노이즈 제거 기술과 판별기술을 서술하고 실제 접속함(PMJ)에 적용하여 PPD 기술의 유효함을 증명하였다.

  • PDF

A Study on the Methods of Vulnerability Analysis for SMTP Server Using Virtual Penetration Testing (가상침투를 이용한 SMTP 서버 취약성 분석 방법 연구)

  • Jang, Jung-Sik;Kim, Jeom-Goo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2000.10a
    • /
    • pp.829-832
    • /
    • 2000
  • 스팸 전자우편과 전자우편 폭탄을 차단하기 위한 제품들은 많이 나와 있지만, 이러한 차단 제품들의 성능에 대한 신뢰성 있는 검증 자료는 많지 않으며. 검증 결과도 벤더(vendor)들의 주관이 개입될 수 있기 때문에 객관성과 공정성 면에서 부족하다고 하겠다. 이것은 차단 제품들의 성능과 잠재된 취약성을 분석하는 분석 방식의 부족과 기존의 분석 방식들의 한계성에 기인한다고 하겠다. 본 논문에서는 기존의 분석 방식들이 가지고 있는 한계점을 개선하고, 제품의 취약성 분석 과정을 자동화하여 소요되는 시간과 인력 낭비를 줄이고, 반복적으로 분석이 용이하며, 분석 결과와 관련된 취약성 정보를 제공하여 비전문가라도 취약성 분석이 용이한 SMTP 서버 보호를 위한 취약성 분석 자동화 도구를 제안한다.

  • PDF

Water Resistance Evaluation of the Oils Coating for Conservation of Wooden Cultural Heritage (목조문화재 보존을 위한 유지류 코팅제의 방수 성능 평가)

  • Na, Won Ju;Cho, So Yeong;Kim, Do Rae;Chung, Woo Yang
    • Journal of Conservation Science
    • /
    • v.31 no.1
    • /
    • pp.13-20
    • /
    • 2015
  • Surface of the wooden cultural heritage has been protected from moisture by natural oils (such as perilla oil and tung oil), which accelerated degradation. But we can find seldom the research on the processes and performances of oil coatings. In this study, the water resistant performances by wood direction were compared to 3 types of natural oil and 2 types of oil stain, and the effect of additional indoor conditioning and temperature of oil were appraised in longitudinal direction. The natural oils block moisture about 79.2% comparing to the control in longitudinal direction. Especially the tung oil showed the outstanding water resistance about 90.5%. The water resistant performances decreased about 8.8% by additional indoor conditioning for 2 years. Heated oil improved the water resistance about average 5.0%.(Max. 9.6% with linseed oil).