• Title/Summary/Keyword: 집전성능

Search Result 68, Processing Time 0.025 seconds

Characteristic analysis of inductive contactless power transformer used for the road/railway to improve the performance. (도로/궤도 매립형 무접촉 집전장치의 전력전달 성능 개선을 위한 특성해석)

  • Han K.H.;Baek S.H.;Lee B.S.;Bae C.H.;Byun Y.S.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1304-1306
    • /
    • 2004
  • Recently, the study for development of system having affinity for environment is on investigation. This issue is also applicable to transportation system. This paper suggested the inductive power transformer used for the road/railway applied to contactless power transfer system. The two secondary windings, large gaped magnetic structure and horizontal alignment between primary and secondary coil for that transformer approach a process for improvement of contactless power transfer system performance.

  • PDF

Test and Evaluation of the Pantograph for Korean High Speed Train (한국형 고속전철 집전장치의 성능 계측 및 평가)

  • 서승일;박춘수;조용현;최강윤;목진용
    • Journal of the Korean Society for Railway
    • /
    • v.6 no.2
    • /
    • pp.94-99
    • /
    • 2003
  • The pantograph for Korean High Speed Train was developed by home-grown technology. In this study, test and evaluation of the current collection performance of the pantograph is conducted. For this purpose, a measuring system is developed and installed on the prototype high speed train. Measurement is conducted while the train runs on the test track. The measuring system is composed of video monitoring system and telemetry & data processing system. It monitors the hazard behavior of the pantograph and measures acceleration and vertical force of the pan head. By applying the measuring system, accurate evaluation of the performance of the pantograph and safety assessment of the interface system of pantograph and catenary is facilitated.

A simulation study on predicting current collection performance with respect to the contact wire tension in 400km/h test run of the next high speed train HEMU-400X (차세대 고속철도 최고속도 시험에서 전차선 장력 증가 단계별 집전 성능 예측 시뮬레이션)

  • Kwon, Sam-Young;Park, Chun-Soo;An, Seung-Hwa
    • Proceedings of the KSR Conference
    • /
    • 2009.05b
    • /
    • pp.201-206
    • /
    • 2009
  • In the testing stage of HEMU-400X(next Korean high speed train) developing project, maximum speed(400km/h) tests will be conducted. On present and near future conditions of the overhead contact lines, 400km/h is over the design speed criteria. The predictions of current collection performance including the percentage loss of contact(arcs level) parameter through dynamic interaction simulation of HEMU-400X maximum speed test run are described in this paper. Various simulations are conducted at the condition of two different contact wire tensions to draw the proper contact wire increasing values in the 400km/h test line under the available contact wire tension supporting condition of that line.

  • PDF

Study on the Aerodynamic Advancements of the Nose and Pantograph of a High-Speed Train (고속열차 전두부 및 팬터그래프 공력성능 향상기술 연구)

  • Rho, Joo-Hyun;Ku, Yo-Cheon;Yun, Su-Hwan;Kwak, Min-Ho;Park, Hoon-Il;Kim, Kyu-Hong;Lee, Dong-Ho
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.416-421
    • /
    • 2008
  • Recent high-speed trains around the world have achieved remarkable improvement in speed. In Korea, the new high-speed train with maximum speed of 400km/h has been developing through the 'Future High-Speed Rail System Project'. The improvement in train speed brings numerous aerodynamic problems such as strong aerodynamic resistance, noise, drastic pressure variation due to the crosswind or passing by, micro-pressure wave at tunnel exit, and so on. Especially, the nose shape of high-speed train is closely related to the most of the aerodynamic problems. Also the pantograph has to be considered for noise prevention and detachment problems. In this paper, the project, 'Research on the Aerodynamic Technology Advancement of the High-Speed EMU' is introduced briefly, which is one of the efforts for the speed improvement of the 'HEMU400x'. Finally, two main results of train nose and pantograph will be shown. First, the optimization of the cross-sectional area distribution of the high-speed train nose to reduce tunnel micro-pressure wave, and second, robust design optimization of the panhead shape of a pantograph.

  • PDF

A Study on the Evaluation of Dynamic Characteristics of the Pantograph for the Korean High-Speed Train through 350km/h Trial Running Test (350km/h 본선 주행시험을 통한 한국형 고속열차 판토그라프의 접촉력 특성 평가 연구)

  • Lee Hi-Sung;Mok Jin-Yong
    • Journal of the Korean Society for Railway
    • /
    • v.8 no.4
    • /
    • pp.342-347
    • /
    • 2005
  • The Korean High-Speed Train(HSR 350x) had been developed by through 'G7-R&D project' in 1996-2002, and has been testing and evaluating it's reliability on the high-speed line until now. A number of core equipments designed and developed by using domestic technologies were boarded on the HSR 350x. In order to verify the performance of HSR 350x and core equipments such as traction system, brake system and pantograph, sophisticated testing and evaluating procedures should be considered and applied. In this paper, the tested and analysed results about the dynamic characteristics of HSR 350x pantograph are introduced in a view point of the mean contact force and it's variation trend, criterion of current collection, and up-lifting of contact wire when the MSR 350x running up to 350 km/h. Through the test and evaluation, we verified that HSR 350x pantograph had an excellent current collection performance and good dynamic characteristics as it had been designed.

A Study on the Performance Analysis and Design of Cathode in Fuel Cells (연료전지 전극(Cathode)의 성능해석 및 설계에 관한 연구)

  • Kim, H.G.;Kang, S.S.;Song, H.Y.;Kang, Y.W.;Kwac, L.K.
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.1
    • /
    • pp.75-79
    • /
    • 2007
  • The cathode design is one of the most important parts in order to enhance the performance of fuel cells. A 3-D model of the porous oxygen reducing cathode with perforated current collectors is analysed for the enhanced design in fuel cells. Simulation is performed using equations of electric potential balance, momentum balance, and mass balance. The gas concentrations are quite large and are significantly affected by the reactions that take place. The weight fraction of oxygen, velocity field for the gas phase, and local overvoltage are illustrated in the porous reactive cathode layer. The current density is also analysed and the result shows the distribution and variation are stated in a wide range. It is found that the rate of reaction and the current production is higher beneath the orifice, and decreases as the distance to the gas inlet increases. The significance of the results is discussed in the viewpoint of the mass transportation phenomena, which is inferred that the mass transport of reactants dictates the efficiency of the electrode in this design and at these conditions.

A case study on the increasing load capacity of AT Feeder system with speed-up train (고속열차 투입에 따른 AT급전계통의 부하용량증가에 관한 사례연구)

  • Na, Youn-Il;Han, Seong-Ho
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.694-698
    • /
    • 2005
  • The operation speed improvement of the train in electric railway must pursue continuously and need the investigation of whole railway system whole. The high-speed of the train is related to not only vehicle technique but also the infrastructure, signal system, operation technique, the trolley line and catenary, economical efficiency. Specially, in case of electric railway, we have to consider a technical investigation which is current collection efficiency improvement, voltage drop countermeasure, equipment capacity, track force, signal system. In this paper, we presents the technical investigation of AT feeder system in order to achieve high speed train in exist real railroad. We proved this approach which will use the whole domestic lines in the future.

  • PDF

Adhesive Strength and Electrochemical Properties of Li(Ni0.5Co0.2Mn0.3)O2Electrodes with Lean Binder Composition (바인더 함량에 따른 Li(Ni0.5Co0.2Mn0.3)O2 전극의 접착력 및 전기화학 성능에 관한 연구)

  • Roh, Youngjoon;Byun, Seoungwoo;Ryou, Myung-Hyun;Lee, Yong Min
    • Journal of the Korean Electrochemical Society
    • /
    • v.21 no.3
    • /
    • pp.47-54
    • /
    • 2018
  • To maximize the areal capacity($mAh\;cm^{-2}$) of $LiNi_{0.5}Co_{0.2}Mn_{0.3}O_2$(NCM523) electrode with the same loading level of $15mg\;cm^{-2}$, three NCM523 electrodes with 4, 2, and 1 wt% poly(vinylidene fluoride)(PVdF) binder content are fabricated. Due to the delamination issue of electrode composite at the edge during punching process, the 1 wt% electrode is excluded for further evaluation. When the PVdF binder content decreases from 4 to 2 wt%, both adhesion strength and shear stress decrease from 0.4846 to $0.2627kN\;m^{-1}$ by -46% and from 3.847 to 2.013 MPa by -48%, respectively. Regardless of these substantial decline of mechanical properties, their initial electrochemical properties such as initial coulombic efficiency and voltage profile are almost the same. However, owing to high loading level, the 2 wt% electrode not only exhibits worse cycle performance than the 4 wt% electrode, but also cannot maintain its mechanical integrity only after 80 cycles. Therefore, if the binder content is reduced to increase the area capacity, the mechanical properties as well as the cycle performance must be carefully evaluated.

Prediction of Optimal Catenary Tension by Dynamic Characteristic Measurement and Dynamic Analysis of Pantograph in High-Speed Train (고속열차 팬터그래프 동특성 측정 및 동역학 해석을 통한 최적 전차선 장력 예측)

  • Oh, Hyuck Keun;Yoo, Geun-Jun;Park, Tae-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.350-356
    • /
    • 2018
  • The contact force, which is the dynamic interaction between the pantograph and the catenary, is an important indicator for evaluating the current collecting quality, which is a stable power supply characteristic to the vehicle. In this study, dynamic contact force characteristics of pantograph of HEMU-430X vehicle, which is a power-distributed high-speed train test vehicle, were analyzed according to the catenary tension and compared with the analytical results using the pantograph-catenary interaction model. As a result of comparing the test results with the analytical results, it was confirmed that the average contact force and the standard deviation of the contact force, which are the main dynamic contact force characteristics, coincide relatively well. Using the analytical model, the relationship between the catenary tension and the contact force is presented according to the vehicle speed, and the optimal catenary tension for each operation speed is presented and compared with the international standard. As a result, it was found that the results obtained from the analysis are comparable to those recommended by international standards.

Development of Quality Analysis Method and System for SOFC (SOFC용 셀의 품질관리 기법개발)

  • Lee, InSung;Park, YoungMin;Kim, DoHyeong;Jun, JoongHwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.81.1-81.1
    • /
    • 2010
  • SOFC 발전시스템의 상용화를 위해 선행되어야 할 것은 스택의 안정적 출력 및 신뢰성 확보이다. 이를 이루기 위해서는 스택을 구성하는 구성요소의 신뢰성 있는 규격 및 검수가 필요하다. 즉, 셀, 밀봉재, 분리판 및 집전체로 대변되는 구성요소들이 스택에 장착되었을 때 그 기능을 최대한 발휘하면서도 점진적 또는 급격한 품질저하가 발생되지 말아야 한다. 특히, 셀의 경우 스택의 성능에 직접적인 영향을 미치는 구성요소로서 품질에 대한 명확한 검수기준이 필요하다. SOFC용 셀은 다공성 anode, 치밀한 전해질, 그리고 다공성 cathode로 구성된 세라믹 소결체이다. 이 때 치밀한 전해질에 결함이 내재되어 있거나 물리적 힘에 의해 신규로 발생할 경우, 연료로 사용되는 수소와 공기가 만나는 cross-over가 발생하게 된다. Cross-over는 연료가 소모되는 문제도 있지만 발열로 인한 Hot spot을 형성시켜서 주변과의 온도구배를 유발하고, 이로 인해 고체 전해질의 균열전파를 일으킬 수 있고 나아가 급격한 셀의 파괴를 야기할 수 있다. 본 연구에서는 SOFC에 사용되는 셀의 형상측정, 물리적 강도 및 결함 검출을 위한 검수기법을 개발하여 스택의 신뢰성 향상과 향후 규격표준화를 위한 기반을 제공하고자, 평판형 셀의 3차원 형상을 정밀하게 측정하는 장치와 일정 면압을 인가하여 특정 형상을 갖고 있는 셀의 물리적 파괴여부를 판단할 수 있는 장치, 그리고 셀의 전해질에 내재된 결함을 검출할 수 있는 장치를 제작하였다. 본 장치들은 $1,000cm^2$급 평판형 셀까지 검수할 수 있도록 고안하여 양산시스템에 접목시킬 수 있도록 고안된 것이다. 본 장치들을 이용한 검수결과, 현재 $700cm^2$급 평판형 셀의 경우 최대 camber가 4mm 이하, 전해질의 He leak rate는 $5{\times}10^{-5}mbar.l/s.cm^2$ 이하라는 검수규격을 본 연구소에서 운전하는 스택에 1차적으로 적용하였으며 현재 검수규격의 신뢰성 및 강화를 위한 연구를 수행 중에 있다.

  • PDF