• Title/Summary/Keyword: 집열기 효율

Search Result 68, Processing Time 0.022 seconds

An Experimental Study on the Solar Collector Efficiency for Apartment Building (공동주택의 태양열 집열기 효율에 대한 실험적 연구)

  • Choi, Byungdo;Kim, Miyeon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.130.2-130.2
    • /
    • 2011
  • The application of solar energy in residential building is general and natural in today. And application methods of solar thermal energy is divided in two kind of form, single evacuated tube and flat-plate form. Then in this study, the efficiency of single evacuated tube and flat-plate system is compared by total and effective area considering the time receiving the solar radiation between 24 hours and the specific time(10:00~15:00). As a result of the experiment, single evacuated tube and flat-plate collector's efficiency is varied by the quantity of solar radiation. And especially, the flat-plate system is more affected by outdoor temperature. Therefore the application of solar thermal system should be considered the solar radiation and outdoor temperature.

  • PDF

An Experimental And Theoretical Study on the Corrugated Water-Trickle Collector (파형단면을 가진 유하식 집열기의 이론 및 실험 연구)

  • Lee, Jong-Ho;Chung, Mo;Park, Won-Hoon
    • Solar Energy
    • /
    • v.7 no.1
    • /
    • pp.42-52
    • /
    • 1987
  • 파형 단면을 가진 유하식 집열기의 이론 및 실험 결과로서 유량, 각도등 집열성능에 미치는 영향등이 고려되었다. 입구 온도와 출구온도 차이가 적을 경우에는 이론과 실험치가 잘 맞으나 온도차이가 많을 경우 혹은 입구온도가 높을 때에는 투과체안에 생기는 결로 및 수증기의 영향으로 편차가 커진다. 개방회로와 폐쇄회로의 경우를 구분하여 실험되었는데 개방회로의 경우 효율은 약간 저하되지만 전반적인 성능은 폐쇄회로와 같은 경향을 나타내었다. 개방회로는 과열을 막는 방편으로 이용될 수 있다.

  • PDF

A Theoretical Study for the Design of Solar Air Heaters Using Porous Material (다공성 물질을 이용한 공기용 태양열 집열기의 설계를 위한 이론적 연구)

  • Hwang, Yong-Ha;Park, Seung-Ho;Kim, Jong-Eok
    • Solar Energy
    • /
    • v.13 no.2_3
    • /
    • pp.79-90
    • /
    • 1993
  • A theoretical study is conducted for the design of solar air heaters using porous material. Radiative characteristics of glazing and porous absorbing media are found through spectral transmittances measured by the Visible spectrometer and the FT-IR. Using those characteristics the efficiencies of collectors are calculated one-dimensionally with the use of the Two-Flux radiation model. The efficiencies increase, as the air flow rates or albedos in the visible range increase, and as albedos in the IR range decrease. The optimum thickness of the porous medium of 15-mesh stainless steel wire screens is 0.001m, which represents the opacity of one.

  • PDF

Drying of Rough Rice by Solar Collectors (태양(太陽) 열(熱 )집열기(集熱機)를 이용(利用)한 벼의 건조(乾燥)에 관(關)한 연구(硏究))

  • Chang, Kyu-Seob;Kim, Man-Soo;Kim, Dong-Man
    • Korean Journal of Food Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.264-272
    • /
    • 1979
  • The flat-plate and tubular soar collectors were designed and constructed for drying the rough rice, and the performance of the collectors and drying effect were investigated when rough rice was packed in grain bin connected to collectors. Average-monthly radiation on a horizontal surface based on bright sunshine in Daejeon area during 1978 was the highest as $16,814\;KJ/m^2{\cdot}day$ in May and the lowest as $4,254\;KJ/m^2{\cdot}day$ in December, and significane was not recognized between the calculated and recorded values. The thermal effciency of collectors were increased as radiation increased during drying period and the average thermal effciency of flat-plate and tubular collectors in 11 to 12 o'clock a.m were 28.12 and 16.75%, respectively. The average inlet temperature of grain bin at 12 o'clock was shown as 20.02 at control 40.5 at grain bin connected to tubular collector and $55.1^{\circ}C$ at grain bin connected to flat-plate collector. In 25 cm rough rice depth in grain bin, tim taken for drying from initial moisture content at 27.4 to decrease upto 17.0% (14.5 % on wet basis) were 32 in control, 18 in grain bin connected to tubular collector and 11 hrs to flat-plate collector, and grain depth influenced drying rate remarkably. In the view point of drying characteristics, drying pattern showed initially falling-rate to constant-rate period finally.

  • PDF

An Experimental Study on the Heat Transfer Characteristics for a Flat Plate Solar Collector with a Heat Pipe (열파이프가 부착된 평판형 태양열 집열기의 열전달 특성에 대한 실험적 고찰)

  • 김철주;임광빈
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.5
    • /
    • pp.1237-1245
    • /
    • 1993
  • In this study, a model of a flat plate solar collector using a heat pipe was manufactured and tested to investigate such operational characteristics of the present system of solar collector as start-up process, temperature distribution on the absorber plate and operation of the heat pipe. Moreover, collector efficiency was measured for 20-30 minutes of operation at various conditions of weather and the result was compared with that tested by Hill et. a. for a flat plate solar collector using direct circulation of coolant. Some results obtained in this study could be summarized as follows. (1) The required time for the initial start-up process was about 5-6 minutes, but the heat pipe began to operate as soon as the absorber plate was exposed to solar radiation. (2) On the absorber plate, the temperature distributions in axial direction maintained nearly constant, while temperature distributions in transversal direction showed smooth decrease with $3-5^{\cird}C$ along with solar radiation. (3) Thermal inertia of the collector system had a favorable effect to damp the turbulent variation of solar radiation. (4) The collector efficiency of the present system showed nearly the same tendency but a decrease of about 10% compared with that using direct circulation of coolant.

The Fundamental Researches to Evaluate PVT Module Performance (PVT 모듈 성능 평가를 위한 기초 연구)

  • Kim, Pilkyu
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.4
    • /
    • pp.1-9
    • /
    • 2018
  • PVT modules commonly can be defined as a combination of PV modules and thermal collectors. After absorbing sun light, electricity and hot water can be actually provided to users simultaneously, which dual outputs (electricity and hot water) have drawn academic interest and industrial activities. Additionally, heat exchange between solar cell and flowing water can enhance solar cell efficiency. Because of PVT modules effectiveness, new international markets and commercial products have made. Especially European, facilities and measurement methods are established to evaluate PVT module performance. However, there are no currently appropriate internationally and domestic standards and facilities to test PVT module performance Herein, to test PVT module performance, indoor thermal simulators and fundamental standard study are considered.

태양열 구동 흡수식 냉방 시스템 실증

  • Gwak, Hui-Yeol
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.11a
    • /
    • pp.353-362
    • /
    • 2005
  • 태양열시스템은 하절기에 급탕과 난방 부하가 적거나, 거의 없어 시스템의 과열 문제가 야기 될 수 있다. 이를 해결하는 방안 중에 하나로 흡수식 냉방시스템을 이용하여 하절기 잉여열원을 활용하여 냉방하는 방법이 대두되고 있다. 태양열 냉방시스템은 전기에너지를 대체하는 효과 뿐 아니라 태양열 연간 이용 효율 극대화에도 크게 기여 할 수 있다. 본 고에서는 국내 기술로 최초로 개발 실용화된 중온용 단일 진공관형 태양열 집열기와 1중 효용 흡수식 냉방기를 이용하여 실증연구를 계획하였다. 태양열 냉방 실증을 위하여 단일 진공관형 태양열 집열기 집열면적 200m2, 축열조(태양열, 급탕, 냉수), 10RT급 냉방기, 냉각탑, 보조 보일러, 원격 제어 및 모니터링 등이 계획 되었다. 실증시험 중간 결과 태양열 냉방시스템은 하절기 맑은 날 하루 동안 약 5 - 6시간 안정적으로 가동 되었으며, 앞으로 온수급탕, 난방 시험을 거쳐 시스템 성능 및 경제성 평가를 통하여 유용성, 안정성 및 신뢰성이 검증 될 계획이다.

  • PDF

Study on Performance Evaluation and Efficiency Comparison for Solar Collector with Thermosyphon Tube-type (태양열집열기의 성능평가 및 열사이폰관형 집열기의 효율 비교 연구)

  • Sim, Han-Sub;Yang, Young-Joon
    • Journal of Energy Engineering
    • /
    • v.23 no.2
    • /
    • pp.175-182
    • /
    • 2014
  • The use of solar energy among renewable energy tends to increase because of infinity and cleanness of resources. Even though the consumption rate of solar energy in our country is still low, however, in recent years, the research for solar energy have been widely conducted due to policy support of government. This study was performed to make the system of performance test for solar collector and to investigate thermal efficiency for solar collector with thermosyphon tube-type. As a result, in case of indoors measurement using halogen lamp, thermal efficiency for solar collector with thermosyphon tube-type was increased about 15~22% after 120 minutes compared with that of solar collector with double evacuated tube-type. In addition, in case of outdoors measurement, thermal efficiency of thermosyphon tube-type was showed maximum about 46% higher than double evacuated tube-type.

A Study on the Effective Installation to the Apartment Through Solar Collector Performance Test (태양열 집열기 성능실험을 통한 공동주택 효율적 설치방안 연구)

  • Kim, Mi-Yeon;Choi, Byung-Do;Kim, Hyung-Geun;Park, Jin-Chul
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.480-487
    • /
    • 2012
  • The application of solar energy in residential building is general and natural in today. And application methods of solar thermal energy is divided in two kind of form, single evacuated tube and flat-plate form. Then in this study, the efficiency of single evacuated tube and flat-plate system is compared by total and effective area considering the time receiving the solar radiation between 24 hours and the specific time(10:00~15:00). As a result of the experiment, single evacuated tube and flat-plate collector's efficiency is varied by the quantity of solar radiation. And especially, the flat-plate system is more affected by outdoor temperature. Therefore the application of solar thermal system should be considered the solar radiation and outdoor temperature.

  • PDF