집열기(集熱器) 열용량(熱容量)을 고려(考慮)한 평판형집열기(平板型集熱器) 성능(性能)에 관(關)한 연구(硏究) (A Study on the Flat-Plate Solar Collector Performance taking into account of the Collector Thermal Capacitance)

  • 이영수;용호택;서정일
    • 태양에너지
    • /
    • 제2권1호
    • /
    • pp.17-23
    • /
    • 1982
  • This paper presents the performance of a Flat-Plate Solar Collector in case of taking into account of the thermal capacitance. The relationships among energy absorption, overall heat loss coefficient and temperature distribution are studied theoretically. And the thermal capacitance of the collector is considered. Also, the results obtained are compared with those of model in which the thermal capacitance is neglected. As the results of this study, the efficiency of the collector having double glazing is higher than the other cases. It is shown that the fluid temperature in the tubes are rising close to linearly. The variations of the outlet temperature of tubes in the model neglecting the effect of thermal capacitance are tend to represent lower slope than that of considering the effect of thermal capacitance.

  • PDF

집광식 태양열 집열기의 태양추적장치를 위한 태양위치계산 (Computation of Sun Position for the Sun Tracking Control System of Solar Concentrator)

  • 박영칠;강용혁
    • 태양에너지
    • /
    • 제18권4호
    • /
    • pp.87-94
    • /
    • 1998
  • This work presents a method to compute the sun position(azimuth and elevation), sunrise and sunset times. Accurate computation of sun position is very important to the precise tracking of the sun for the solar concentrator, which enables the maximum collection of solar energy. Methods to compute the sun position are available in the literature already. However most of them do not have accuracy verification, thus makes hard in selecting the most accurate sun position computation method. We first select the most accurate sun position computation method among the methods presented in the literature by comparing the computed sun position with Korean Almanac of Korea Astronomy Observatory. Then a procedure to compute the sunrise and sunset times is presented. Computed sun position shows $0.02^{\circ},\;0.6^{\circ}$ and one minute differences in azimuth, elevation and sunrise/sunset times respectively compared with Korean Almanac.

  • PDF

태양열집속집열기의 설계 방법에 관한 연구 (A New Approach to Design Method of the Solar Compound Parabolic Concentrator with Tubular Absorber)

  • 김석종;임상훈
    • KIEAE Journal
    • /
    • 제2권3호
    • /
    • pp.33-38
    • /
    • 2002
  • The intermediate range of temperatures($100{\sim}300^{\circ}C$) which can be achieved with CPCs(Compound Parabolic Concentrators) without tracking device provides both economic and thermal advantages for solar collector design. The present paper summarizes critical design considerations for CPC with cylindrical absorber and its optical performance using ray tracing program. Concentration ratios vary as acceptance half angle, ratio of reflector height to aperture width and ratio of reflector area to aperture area. This effects showed that the concentration ratio was increased as acceptance angle but optimum ratio of reflector height to aperture width existed at critical value. As a result of ray tracing, solar ray losses was maximized at acceptance half angle and this problem was solved by increasing absorber tube diameter. The concentrating flux distribution on the absorber surface was uniform but peak flux existed.

교육시설에 적용 가능한 태양열 흡수식 냉각 시스템 (Solar Absorption Cooling System applicable to Educational Facilities)

  • 윤성민;백인수;한영태;남효갑
    • 교육시설 논문지
    • /
    • 제18권3호
    • /
    • pp.35-41
    • /
    • 2011
  • Performance of a small-capacity solar absorption cooling system was investigated experimentally. Ten sets of evacuative-tube solar-heat collectors and a 5 kW single-stage absorption cooler were combined to produce a hybrid cooling system. The performance of the cooling system was measured using a tim-coil unit installed in a small plastic storage. It was found from the test on a sunny day of May that when the temperature of the hot water supplied from the solar collectors to the generator of the absorption cooler reached $60^{\circ}C$, the absorption cooler started cooling and the cold water temperature measured from the fan-coil unit reached $18^{\circ}C$. The COP, which is defined as the ratio of the cooling power to the total electrical power input was higher than 1.0.

  • PDF

진공관형 태양열 집열기를 이용한 건조장치의 열교환기 해석 (Analysis of heat exchanger in the drying system using solar collector with evacuated tubes)

  • 강형석;한영민;이귀현;이성주;윤세창
    • 신재생에너지
    • /
    • 제2권1호
    • /
    • pp.46-55
    • /
    • 2006
  • The performance enhancement of heat exchanger in the drying system using solar collector with evacuated tubes is analyzed. First, for this analysis, the heat loss from a reversed trapezoidal fin attached at the pipe is calculated as a function of convection characteristic number ratio, fin base length and fin tip length. Also, the optimum heat loss and fin tip length of the fin under certain conditions are presented. The overall surface effectiveness of the cylinder with reversed trapezoidal fins in the heat exchanger are shown as a function of half fin base height, fin lateral slope and fin tip length.

  • PDF

진공관형 태양열 집열기의 흡수관 형상 변화에 따른 성능 비교 (Performance comparisons of the glass evacuated tube solar collectors of different absorber tubes)

  • 김용;서태범;윤성은;김영민
    • 신재생에너지
    • /
    • 제2권1호
    • /
    • pp.56-65
    • /
    • 2006
  • The thermal performance of glass evacuated tube solar collectors are numerically and experimentally investigated. Four different shapes of solar collectors are considered and the performances of these solar collectors are compared. Dealing with a single collector tube, the effects of not only the shapes of the absorber tube but also the incidence angle of solar irradiation (beam irradiation) on thermal performance of the collector are studied. However, the solar irradiation consists of the beam irradiation as well as the diffuse irradiation. Also, the interference of solar irradiation and heat transfer interaction between the tubes exist in an actual solar collector, These effects are considered in this study experimentally and numerically. The accuracy of the numerical model is verified by the experimental results. The result shows that the thermal performance of the absorber used a plate fin and U-tube is the best.

  • PDF

집열기 성능향상에 관한 연구현황 (State of Arts on the Performance of Collector)

  • 이종호;이진국
    • 태양에너지
    • /
    • 제7권1호
    • /
    • pp.75-86
    • /
    • 1987
  • In this research, we have analyzed the researches and productions of solar collectors in Korea and U.S.A. In the U.S., collectors are produced by hundreds of manufacturers. The amounts are 23 million sq.ft for the liquid system, 358 thousand sq.ft of the air system and 266 thousand sq.ft for the vacuum tube and focus collectors. In Korea, a very small quantity is produced by several manufacturers. So they have to be largely dependent upon the imports in Korea. In the U.S., research topics include the materials development, design and applications. In Korea, however materials research has been rare and there have been only a few papers on selective coating. Researches have been limited to the system design and collector testing.

  • PDF

공동주택용 태양열원 급탕시스템의 운전성능 연구 (A Study on the Operating Performance of Solar Assisted Hot Water System for Apartment Houses)

  • 이윤규;황인주
    • 설비공학논문집
    • /
    • 제15권11호
    • /
    • pp.928-936
    • /
    • 2003
  • In the present study, feasibility investigation on the solar assisted hot water supply system for apartment houses was carried out by the review of service facility and heat load pattern. Also analysis and experiment of the small sized system model were performed. This hybrid system are consists of solar collector, heat storage tank, controller, and gas boiler using LPG as a secondary heat source. The analytical results showed a good agreement with experimental data. We found that this hybrid system could reduce the energy cost by 30% for hot water compared to typical boiler system in the apartment houses. Also we showed that this model could be used for the energy and economic analysis of the hybrid system.

지역 및 에너지소비패턴에 따른 태양열 집열기의 최적설치각 해석 (Optimum Installation Angle of Solar Collectors according to Region and Energy Consumption Patterns)

  • 전용준;박경순
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권4호
    • /
    • pp.61-67
    • /
    • 2018
  • Solar energy depends on the altitude and azimuth of the sun, and the amount of energy collected on the slope depends on the latitude of the area being installed. However, since most solar heating systems are fixed to the ground, it is necessary to analyze the optimal installation angle from the early design stage. However, problems arise when energy consumption is not considered together because heating systems are not used in the summer In this study, the optimum installation angles of the solar collectors according to the latitude of the installation area are not simply determined by the amount of energy collected, but because the system is overheated due to climate change or energy usage patterns, And the amount of additional energy input.

진공복사관식 집열기의 성능실측 및 최적화 연구 (Study on the Optical Performance of Evacuated Solar Collectors)

  • 천원기;강상훈;김기홍;이용국;장래웅
    • 한국태양에너지학회 논문집
    • /
    • 제21권4호
    • /
    • pp.63-71
    • /
    • 2001
  • This work has been carried out to find the ideal operating conditions for solar vacuum tube collectors which are widely used at present. Various types of solar collectors including a flat plate one were experimentally tested and examined to determine their thermal efficiencies and operating characteristics. Generally, solar vacuum tubes can be classified into two groups according to their design features. Of these, one is characterized by the insertion of a metallic device(such as a finned heat pipe) in an evacuated glass tube for the collection and transportation of solar energy. The other utilizes double glass tubes where the smaller one is contained inside the bigger one and soldered to each other after the small gap between them is evacuated. Both of these solar collectors are designed to minimize convection heat losses by removing the air which is in direct contact with the absorber surface. The performance of the former type can be readily analyzed by applying the relevant correlations developed for flat plate solar collectors. This has been demonstrated in the present study for the case of a solar collector where a heat pipe is inserted in an evacuated tube.