• Title/Summary/Keyword: 질산성 질소 제거

Search Result 199, Processing Time 0.031 seconds

Effect of Factors of Nitrification Process in Wastewater Treatment (폐수처리에 있어 질산화 공정 인자의 영향)

  • Jeong, Gwi-Taek;Park, Seok-Hwan;Park, Jae-Hee;Lim, Eun-Tae;Bang, Sung-Hun;Park, Don-Hee
    • KSBB Journal
    • /
    • v.24 no.3
    • /
    • pp.296-302
    • /
    • 2009
  • This paper was investigated the research regarding the effects of several factors such as initial ammonium nitrogen concentration, aeration rate. biomass amount and C/N ratio on nitrification process using synthetic wastewater and activated sludge obtained from wastewater treatment facility. As a result, in high ammonium nitrogen concentration above 100 mg/L, the pH of wastewater was dropped to pH 6.8. The increases of initial ammonium nitrogen concentration, aeration rate and initial biomass amount were linearly enhanced the removal rate of ammonium nitrogen. In the condition of C/N ratio of 0 to 3, high ammonium nitrogen removal rate was obtained.

Simultaneous Removal of Nitrate and Trichloroethylene by Zero Valent Iron and Peat (영가철과 피트를 이용한 질산성질소와 트리클로로에틸렌의 제거)

  • Min, Jee-Eun;Kim, Mee-Jeong;Park, Jae-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.10
    • /
    • pp.1074-1081
    • /
    • 2006
  • As common pollutants in surface and groundwater, nitrate nitrogen($NO_3-N$) and trichloroethylene(TCE) can be chemically and biologically reduced by zero valent iron(ZVI) and peat soil. In batch microcosm experiments, chemical reduction of TCE and nitrate was supported by hydrogen from ZVI. For biological degradation of TCE and denitrification peat soil was introduced. ZVI reduced TCE, while peat provided TCE sorption site and microbes performing biological degradation. Nitrate reduction was also achieved by hydrogen from ZVI. In addition, indirect evidence of denitrification was observed. More reduction of TCE and nitrate was achieved by ZVI+peat treatment however nitrated reduction was hindered in the presence of TCE in the system due to the competition for hydrogen. TCE reduction mechanism was more dependent on ZVI, while nitrate was peat-dependent. Hydrogen and methane concentration showed that peat had various anaerobic denitryfing and halorespiring bacteria.

Comparison of efficiency in Mainstream ANAMMOX process for ratio of ammonium to nitrite (암모니아성 질소 대비 아질산성 질소 비율에 따른 Mainstream A NAMMOX 공정 효율 비교)

  • Gil, Kyung Ik;Lee, Da Won;Lee, Ji Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.421-421
    • /
    • 2021
  • 도시화, 산업화로 인해 하수처리장 유입하수 내 질소 농도가 증가하면서 그에 따른 부영양화 발생, 수생태계에 독성을 미치는 등의 악영향 또한 증가하게 되었다. 하수 내 고농도 질소를 처리하기 위해 1990년 초 연구가 시작되어 현재 보편적으로 사용되고 있는 생물학적 질소 제거 공정은 산소공급과 외부탄소원 보충 과정에서 상당한 비용이 소요된다. 이와 같은 문제점이 대두됨에 따라 고도의 질소 제거 공정이 요구되면서, 경제적으로 개선이 이루어져 기존의 질산화·탈질 공정보다 효율적인 혐기성 암모늄 산화 공정(ANaerobic AMMonium OXidation, ANAMMOX)이 제안되었다. ANAMMOX 공정은 혐기성 조건 아래 전자공여체와 전자수용체로써 암모니아성 질소와 아질산성 질소를 이용해 질소가스 형태로 질소를 제거하는 공정이다. 질산화·탈질 공정과 비교했을 때, 폭기과정에서의 산소요구량 감소, 외부탄소원 불필요, 질소 제거 과정 단축 등의 장점을 가진다. 본 연구는 수처리공정에서의 ANAMMOX 공정의 적용 가능성을 확인하고, 암모니아성 질소대비 아질산성 질소 비율에 따른 Mainstream ANAMMOX 공정의 효율 비교를 통해 공정의 안정성과 높은 제거효율을 확보할 수 있는 NH4+ 대비 NO2- 비율을 도출하는데 목적이 있다. 실험실 규모의 Mainstream ANAMMOX 반응조에 적용한 비율은 선행연구를 비롯한 화학양론식에서 제시된 비율을 바탕으로 산정하였다. 1.00부터 1.30의 전체적인 비율을 Initial과 Advanced 2개의 구간으로 나누어 운전한 결과, 각 구간의 NH4+ 제거효율은 각각 58~86%, 94~99%였다. NH4+ 대비 NO2- 비율이 증가함에 따라 공정의 안정성이 확보되고, NH4+ 및 총질소(TN) 제거효율이 증가하는 경향이 나타났다. 본 연구의 결과는 수처리공정에서의 안정적인 ANAMMOX 공정 적용을 유도하고, ANAMMOX 공정의 성능개선을 도모하는 연구의 기초로 활용될 수 있다.

  • PDF

Removal of Nitrate in Column Reactors Using Surfactant Modified Zeolite (SMZ를 이용한 컬럼반응조 내 질산성 질소의 제거)

  • 박규홍;이동호
    • Journal of Soil and Groundwater Environment
    • /
    • v.8 no.2
    • /
    • pp.55-61
    • /
    • 2003
  • The objective of this study was to investigate the characteristics of nitrate removal by conducting the column test in order to see the performance of surfactant modified zeolite (SMZ) as a permeable reactive barrier material. The prediction of nitrate removal was tested using the one-dimensional advective-dispersive model fitted to the experimental breakthrough curve. A methodology for scaling up to in-situ permeable reactive barrier was also proposed. The breakthrough of nitrate in the column packed with SMZ was well predicted using linear equilibrium adsorption model. The breakthrough time and half-life obtained by breakthrough experiment with variation of flowrates were decreased with the increase of flowrates. When 10㎥/day of groundwater containing the 50 mg/l of nitrate is to be treated to satisfy the potable water quality criteria (10 mg/l) by SMZ reactive barrier, 300 tons of SMZ and about 6 years of breakthrough time will be required, suggesting that 165 million wons are needed as barrier material expenses in each 6 years besides the initial design and construction expenses and the minimal monitoring and maintenance expenses.

Simultaneous Removal of Nitrogen and Phosphorus by Rotating Biological Activated Carbon Process (회전생물활성탄[RBAC] 공정을 이용한 질소.인의 동시 제거)

  • Nam, Beom-Sik;Lee, Yeong-Ho;Jo, Mu-Hwan
    • KSBB Journal
    • /
    • v.14 no.5
    • /
    • pp.606-610
    • /
    • 1999
  • The purpose of this study was to develop and evaluate rotating biological activated carbon(RBAC) process for nitrogen and phosphorus removal with increasing loading rate. The removal efficiency of $NH_4^+$-N was observed to be higher than 96.5% at all runs, and the relative stable levels of effluent $NH_4^+$-N, $NO_2^-$-N, $NO_3^-$-N could be maintained. The removal efficiency of T-N was observed to be higher than 90%, except RUN 1. The T-P removal efficiency was kept between 32.7% and 49.8%, and the amount of biomass was kept between 269 mg/g support and 473 mg/g support with varying loading rate.

  • PDF

Separation Technologies for the Removal of Nitrate-Nitrogen from Aqueous Solution (수용액으로부터 질산성질소 제거를 위한 기술)

  • Seo, Yang Gon;Jung, Se Yeong
    • Clean Technology
    • /
    • v.23 no.1
    • /
    • pp.1-14
    • /
    • 2017
  • At high nitrate concentrations, water must be treated to meet regulated concentrations because it results in threat to human health and eutrophication of natural water. However, it is almost impossible to remove nitrate by conventional water treatment methods such as coagulation, filtration and precipitation, due to its high water solubility. Therefore, other technologies including adsorption, ion exchange, reverse osmosis, denitrification, and electrodialysis are required to effectively remove nitrate. Each of these technologies has their own strengths and drawbacks and their feasibility is weighted against factors such as cost, water quality improvement, residuals handling, and pre-treatment requirements. An adsorption technique is the most popular and common process because of its cost effectiveness, ease of operation, and simplicity of design. Surface modifications of adsorbents have been enhanced their adsorption of nitrate. The nitrate-selective membrane process of electrodialysis reversal and reverse osmosis have proven over time and at many locations to be highly effective in removing nitrate contaminating problems in aqueous solutions. Both electrodiaysis and reverse osmosis methods generate highly concentrated wastes and need careful consideration with respect to disposal.

Synthesis and Functionalized Conditions of Quaternized Poly(vinylimidazole-co-trifluoroethylmethacrylate-co-divinylbenzene) Anion Exchange Membrane (질산성 질소 제거용 Quaternized Poly(vinylimidazole-co-trifluoroethylmethacrylate-co-divinylbenzene) 음이온교환막 제조와 관능화 조건)

  • Oh, Chang Min;Hwang, Taek Sung
    • Polymer(Korea)
    • /
    • v.39 no.1
    • /
    • pp.157-164
    • /
    • 2015
  • In this study, we synthesized poly(vinylimidazole-co-trifluoroethylmethacrylate-co-divinylbenzene) (PVTD) copolymer and introduced functional group through quaternization reaction for removing nitrate from drinking water. Also, optimizing conditions (reaction time, reaction temperature and functionalized agents concentration) for introducing the functional group were confirmed. The basic properties such as water uptake, swelling ratio, electrical resistance, ion exchange capacity and anion permselectivity for removing nitrate from drinking water were measured. The optimal values of water uptake, electrical resistance and ion exchange capacity of synthesized anion exchange membrane were 51.2%, $5.4{\Omega}{\cdot}cm^2$, and 1.04 meq/g, respectively.

Nitrogen Removal in Fluidized Bed and Hybrid Reactor using Porous Media (다공성 담체를 이용한 유동상 및 하이브리드 반응기에서의 질소제거)

  • Jun, Byong-Hee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.5
    • /
    • pp.542-548
    • /
    • 2005
  • A fluidized bed reactor containing porous media has been known to be effective for nitrogen and organic matters removal in wastewater. The porous media which attached microbes plays important roles in simultaneous nitrification/denitrification (SND) due to coexistence of oxic, anaerobic and anoxic zone. For SND reaction, oxygen and organic substrates should be effectively diffused from wastewater into the intra-carrier zone. However, the overgrowth heterotrophic microbes at the surface of porous media may restrict from substrates diffusion. From these viewpoints, the existence and effect of heterotrophic bacteria at surface of porous media might be the key point for nitrogen removal. A porous media-membrane hybrid process was found to have improved nitrogen removal efficiency, due to stimulated denitrification as well as nitrification. Microelectrode studies revealed that although intra-media denitrification rate in a conventional fluidized bed was limited by organic carbon, this limitation was reduced in the hybrid process, resulting in the increased denitrification rate from 0.5 to $4.2\; mgNO_3-N/L/hr$.

Comparison of Pollutants Removal between the Intermittently Aerated Bioreactor(IABR) and Intermittently Aerated Membrane Bioreactor(IAMBR) (간헐포기공정과 막결합 간헐포기공정의 오염물질 제거특성 비교)

  • Choi, Chang Gyoo;Lee, Kwang Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.1B
    • /
    • pp.119-124
    • /
    • 2006
  • The purpose of this study was the comparison of pollutants removal and the track study of the nitrogen and phosphorus, the estimation of the nitrification and denitrification rate, and the investigation of the nitrogen mass balance between intermittently aerated membrane bioreactor(IAMBR) and intermittently aerated bioreactor(IABR), thus it verified the validity of the membrane submergence. As a result, it had no difference of organic matter removal, however, IAMBR showed better efficiency than IABR in the nutrients. Also, $NO_3{^-}$-N concentration at the anoxic state in the reactor was lower in IAMBR, and the denitrified nitrogen of IAMBR was 40.9%, that of IABR was 10.7%, thus it found out that the denitrification capability of IAMBR was higher than IABR above fourfold. Therefore, it seems resonable to conclude that the membrane helps to improve the removal of pollutants, because of the high MLSS concentration and the available method of intermittent inflow/outflow.