• Title/Summary/Keyword: 진압대책

Search Result 45, Processing Time 0.023 seconds

Muscuoloskeletal Disorders of Korean Fire Fighters: Applicants for Public Worker's Compensation from 2011 to 2013 (소방공무원의 근골격계 질환: 2011년~2013년 공상신청 분석)

  • Yoon, Jangwhon
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.133-137
    • /
    • 2016
  • The aims of this study were to analyze the Korean fire fighters' applications for the public worker's compensation between 2011 and 2013 and to suggest a feasible solution for prevention of work-related musculoskeletal disorders. The Korean Ministry of Public Safety and Security provided the complete list of fire fighters' application from January 2011 to December 2013. 510 applicants with chief complaint of musculoskeletal disorders were screened out of all 1596 applicants. Male applicants were 92%. Fire fighters in their early 40's applied most frequently, followed by those in early 30's. Musculoskeletal disorders of fire fighters were reported most frequently in May and June. Regionally, Seoul had most applicants and Jeonbuk showed the highest prevalence. Low back was the most frequently reported body part followed by the knee. Ligament was insured most frequently followed by vertebral disc and bone. The fire fighter's injury occurred while fire extinguish (38.3%), emergency medical service (37.7%), rescue (12.4%), and other duties. Result of this study suggests further investigation on the large variation in regional prevalence and on the injury mechanism of musculoskeletal disorders especially during the fire extinguish and emergency medical service.

A Study on how to improve Survey of Fire Safety Management of manufacturing plants (The Medium and Small-sized Manufacturing industry) (제조 사업장의 소방안전관리 실태조사 및 개선방안에 대한 연구 (중소규모 제조사업장 중심으로))

  • Choe, Yeong-Gi;Kim, Byeong-Seok
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2013.11a
    • /
    • pp.483-497
    • /
    • 2013
  • 현대사회가 발전 할수록 대량산업화와 도시화가 심화되어 건축물의 초고층화 및 대형화가 증가하고 있으며, 안전적인 건축물 보다는 건물 및 제조사업장의 시각적인 디자인에 치우쳐 화재하중이 높은 건축자재의 내 외장재 및 고급스러운 장식물을 사용함으로써 그 위험뿐 만 아니라 화재발생시 대규모 인명 및 재산상의 피해를 가져오게 된다. 그리고 제조사업장화재는 화재로 인한 직접적인 손실 즉 물적 손실은 물론 생산중단으로 인한 간접적인 손실은 실로 측정하기가 어렵다. 지금까지 발생한 제조사업장화재의 발화요인별 분석은 부주의, 전기적, 미상 순으로 인한 화재가 가장 많고 발화열원은 작동기기, 담뱃불(라이터), 마찰 전도 복사등이 주요 원인이 되고 있고 대형화제 취약시설로는 공장 및 창고로 나타나고 있다. 소방방재청의 통계자료를 살펴보면 2012년 화재 발생현황 중 발화요인에 대한 화재별 장소 건수를 검토 한 결과 비주거의 화재발생 16,009건 중 5,758건으로 (36%)부주의이고, 주거에도 화재발생 10,715건 중 5,560건으로 51.9%의 부주의로 가장 높은 것으로 나타났다. 그러므로 제조사업장의 사소한 부주의로 발생하는 화재를 예방하기 위해서는 소방안전관리자의 처우개선과 기업활동규제완화의 겸직 허용을 재검토 하여야 하며, 소방안전관라자의 실무능력 강화를 위한 소방안전관리 실무교육과정을 이론적 교육 보다는 현장 실습위주로 할 필요가 있다. 이를 위해서는 소방안전관리자에 대한 법정 실무교육 횟수를 확대하여 현행 2년에 1회 에서 1년에 1회로 하고, 실무교육에 있어서도 우수송방안전관리 업체를 선정하여 화재예방에 대한 구체적인 업무를 활성화 하고, 문제 발생요소들을 분석하여 실습을 통한 소방안전관리자의 실무교육을 실시해야 할 것이다. 이러한 전문 소방안전관리자로 소방대상물의 소방교육 및 훈련을 성실히 수행 해야 할 것 이다. 한순간의 부주의로 인하여 화재가 발생하면 돌이킬 수 없는 수백명의 생명을 앗아가고, 수백억원대의 재산피해를 줄이기 위해서는 소방안전관리자의 역량을 넓히고 화재예방 업무를 최우선적으로 수행해야 할 것이다. 화재예방을 위해 소방안전관리자의 업무개선 및 전문교육을 활성화 하여 업무능력을 향상 시켜 화재발생시 초기진압에 신속하고 정확하게 대처해야 한다는 것이 전문적인 화재예방 대책 일 것이다.

  • PDF

Experimental Study on Moisture Content According to Addition of Surfactants (계면활성제 첨가에 따른 함수율에 관한 실험적 연구)

  • Kim, Nam-Kyun;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.29 no.2
    • /
    • pp.79-83
    • /
    • 2015
  • The fire accident is a representative type of disaster that can largely impact on business. Therefore, precautionary measures and rapid initial response is very important when a disaster occurs. The storage of porous combustibles is inevitable in coal yard, plywood processing industry, and others that are currently operating. Initial fire fighting of fire and identifying the ignition point in such a porous combustible storage space are so difficult that if the initial response is failed, being led to deep-seated fire, surface fire is likely to result in secondary damage. In addition, deep-seated fire can cause personal injuries and property damage due to a large amount of toxic gases and reignition. Therefore damage reduction measures is required around the storage space to handle a porous flammable. Improving the penetration performance of the concentration of the surfactant is carried out as underlying study, which is about an deep-seated fire extinguishing efficiency augmentation when using wetting agents. The porous materials used in the experiments is radiata pine wood flour, which occupies more than 75% of the domestic wood market. Fire fighting water is selected as Butyl Di Glycol (BDG), which is being used for infiltration extinguishing agent, and the experiment was carried out by producing a standard solution. The experiment was carried out on the basis of the Deep-Seated Fire Test of NFPA 18. The amount of watering, porous material to the internal amount of penetration, and runoff measurement out of the porous material was conducted. According to experimental results, as the surface tension is reduced, the surfactant concentration macroscopic penetration rate decreases, but infiltration to a porous material is shown to have growth characteristics.

A Study on the Evacuation Risk of Simultaneous Fires from Exterior (외장재에 의한 동시다발적인 화재의 피난위험성에 관한 연구)

  • Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.26 no.4
    • /
    • pp.48-54
    • /
    • 2012
  • In order to study on the evacuation risk when connate fires caused by vertical fire spread of the exterior occurs, the egress simulations based on the relevant scenarios has carried out. As a result of it, ASET (permitted evacuation time) was reached in between 550 to 650 seconds in entire floors after vertical smoke spread from fire of combustible exteriors. In particular, ASET was 358 seconds in the first floor, 490 seconds in the six floor and 473 seconds in the tenth floor. In addition, five floors of all levels, the 1st floor, the 6th floor and the 28th floor ~30th floor, show RSET (minimum evacuation time) which is bigger than ASET as evacuation risk. This result presents occupants in high rise buildings with more than 15 floors might not be able to egress of them using staircases due to huge population attempting to evacuate simultaneously. Particularly, 699 people in the upper levels by smoke from the first floor are having difficulty escaping this building since ASET on the first floor adjacent to the ignition point was 358 seconds which is relatively reached fast. Considering a prevention method of the fire and smoke spread, architects have to use non-combustible exterior in the building's facade to be required as an active fire protection system.

Status of RDA Researches on Weed Control for Rice Nurserybed (농진청(農振廳)의 못자리 잡초방제(雜草防除) 연구(硏究) 현황(現況))

  • Kim, S.C.;Chung, G.S.;Kim, D.S.
    • Korean Journal of Weed Science
    • /
    • v.5 no.2
    • /
    • pp.175-186
    • /
    • 1985
  • Research situation and recent research activities of the RDA of Korea were reviewed and summarized for rice nurserybed. Sixty five percent of total 784 weed research items were carried out as rice research while only 6 percent was belonged to nurserybed within rice research. The floristic composition based on the degree of dominance significantly affected by herbicide properties, type of nurserybed and seeding itself. Herbicidal phytotoxicity of currently used several herbicides was greatly dependent upon the covering, absorption, germination, and irrigation regimes. The new safening agent "CGA 123 407" (4,6-dichloro-2-phenyl-pyrimidine) permited the safe application of pretilachlor (2-chloro-2',6-diethyl-N-(2-propoxyethyl) acetanilide) as a pre-emergence herbicide without reducing herbicidal efficacy. Several new herbicides, pyrazolate (4-(2,4-dichlorobenzoyl)-1,3-dimethylpyrazol-5-yl-p-toluenesulphonate), SL-49 (1,3-dimethyl-4-(2,4-dichlorobenzoyl)-5-phenacyloxy-pyrazole) MY-93 (S(1-methyl-1-phenethyl)-piperidine-1-carbathioate) and DPX-84 ((methyl 2- ((4,6-dimethoxypyrimidin-2-yl) amino-carbonyl) aminosulfonylmethyl)) benzolate)) performed satisfactorily in terms of safety and herbicidal efficacy for both surface covered and surface pressed nurserybed after herbicide application and thus expected very significant contributions not only for all kind of nurserybeds but also for direct seeding.

  • PDF