• Title/Summary/Keyword: 진동 가속도

Search Result 943, Processing Time 0.02 seconds

Hand-Arm Vibration and Noise Levels of Double-Hammer Type and Oil-Pulse Type Impact Wrenches in Automobile Assembly Lines (자동차 조립라인에서 이중-헴머형(Double-hammer type) 임펙트 렌치와 오일-펄스형(Oil-pulse type)임펙트 렌치 에어공구의 국소진동가속도 및 소음수준)

  • Jeung, Jae-Yeal;Kim, Jung-Man
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.2
    • /
    • pp.147-159
    • /
    • 1995
  • This study was conducted to introduce fundamental data of hand-arm vibration and noise exposure levels with impact wrenches(double-hammer impact wrenches and oil-pulse impact wrenches) used in automobile assembly lines considering the process variables and tool variables. In studing, products per day, required time screwing the bolts or nuts per bolts or nut were considered as process variables, and capacity of bolts or nuts, air consumptions per minute, tool weights, RPM were considered as tool variables. Hand-arm vibration levels of 3 axis in each hand were measured using the instruments compling with ISO/DIS 5349 and noise levels were measured using a noise logging dosimeter. The results were as follows : 1. Required time to screwing the bolt or nut by oil-pulse impact wrenches is shorter than double-hammer impact wrenches but total daily exposure time of oil-pulse impact wrenches was higher than double-hammer impact wrenches because the number of bolts or nuts per cycle was many. 2. Oil-pulse impact wrenches have been used to screwing the large bolt or nut in comparing with double-hammer impact wrenches and required time to screwing the bolts or nuts were shorter than double-hammer impact wrenches because oil-pulse impact wrenches were using high RPM and large air consumption per minute. Noise level of oil-pulse impact wrenches was 8 dB(A) lower than double-hammer impact wrenches. 3. Dominant hand-arm vibration levels of double-hammer impact wrenches in each hand were $8.24m/sec^2$ of Zh axis in right hand and $9.60m/sec^2$ of Xh axis in left hand. Dominant hand-arm vibration level of oil-pulse impact wrenches in each hand was $2.59m/sec^2$ of Xh axis in right hand and $3.23m/sec^2$ of Yh axis in left hand. 4. In double-hammer impact wrenches, corresponding hand-arm vibration levels of Xh, Yh, Zh axis in left hand were higher than hand-arm vibration levels of right hand in 3 axis. In oil-pulse impact wrenches, Xh axis of right, Yh axis of left, Zh axis of left were higher than the corresponding hand-arm vibration levels of Xh, Yh, Zh axis in right and left hand. 5. Correlation coefficients among Xh, Yh. Zh axis of right and left hand hand-arm vibration levels in double-hammer impact wrenches and oil-pulse impact wrenches were commonly high in Yh axis and correlation coefficients of Yh axis in double-hammer impact wrenches and oil-pulse impact wrenches were 0.76 and 0.86,respectively. 6. As a measure repetitiveness, plotting total daily exposure time with the number of bolts or nut per cycle, direct correlation was shown between repetitiveness and hand-arn vibration exposure, and correlation coefficient between the number of bolts or nut per cycle and total daily exposure time in double-hammer impact wrenches, oil-pulse impact wrenches were 0.84 and 0.50, respectively. 7. Considering the total acceleration level and tool variables in double-hammer impact wrenches and oil-pulse impact wrenches, air consumption in right hand, and bolt or nut capacity in left hand were commonly the variable that explainability was high. Considering the noise and tool variables in double-hammer impact wrenches and oil-pulse impact wrenches, air consumption per minute was commonly the variable that explainability was high.

  • PDF

Echocardiographic Diagnosis of Pulmonary Arterial Hypertension in Chronic Lung Disease with Hypoxemia (만성 저산소성 폐질환의 폐동맥 고혈압에 대한 심초음파 검사)

  • Chang, Jung-Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.6
    • /
    • pp.846-855
    • /
    • 1999
  • Background : Secondary pulmonary hypertension is an important final endpoint in patients with chronic hypoxic lung disease, accompanied by deterioration of pulmonary hemodynamics. The clinical diagnosis of pulmonary hypertension and/or cor pulmonale could be difficult, and simple noninvasive evaluation of pulmonary artery pressures has been an relevant clinical challenge for many years. Doppler echocardiography might to be a more reliable method for evaluating pulmonary hemodynamics in such patients in terms of the accuracy, reproducibility and easiness for obtaining an appropriate echocardiographic window than M-mode echocardiography. The aim of this study was to assess echocardiographic parameters associated with pulmonary arterial hypertension, defined by increasing right ventricular systolic pressure(RVSP), calculated from trans-tricuspid gradient in patients with chronic hypoxic lungs. Method : We examined 19 patients with chronic hypoxic lung disease, suspected pulmonary hypertension under the clinical guidelines by two dimensional echocardiography via the left parasternal and subcostal approach in a supine position. Doppler echocardiography measured RVSP from tricuspid regurgitant velocity in continuous wave with 2.5MHz transducer and acceleration time(AT) on right ventricular outflow tract in pulsed wave for the estimation of pulmonary arterial pressure. Results : On echocardiography, moderate to severe degree of pulmonary arterial hypertension was defined as RVSP more than 40mmHg, presenting tricuspid regurgitation. Increased right ventricular endsystolic diameter and shortened AT were noted in the increased RVSP group. Increased RVSP was correlated negatively with the shortening of AT. Other clinical data, including pulmonary functional parameters, arterial blood gas analysis and M mode echocardiographic parameters were not changed significantly with the increased RVSP. Conclusion : These findings suggest that shortened AT on pulsed doppler can be useful when quantifying pulmonary arterial pressure with increased RVSP in patients with chronic lung disease with hypoxemia. Doppler echocardiography in pulmonary hypertension of chronic hypoxic lungs is an useful option, based on noninvasiveness under routine clinical practice.

  • PDF

An Analytical Study on the Seismic Behavior and Safety of Vertical Hydrogen Storage Vessels Under the Earthquakes (지진 시 수직형 수소 저장용기의 거동 특성 분석 및 안전성에 관한 해석적 연구)

  • Sang-Moon Lee;Young-Jun Bae;Woo-Young Jung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.152-161
    • /
    • 2023
  • In general, large-capacity hydrogen storage vessels, typically in the form of vertical cylindrical vessels, are constructed using steel materials. These vessels are anchored to foundation slabs that are specially designed to suit the environmental conditions. This anchoring method involves pre-installed anchors on top of the concrete foundation slab. However, it's important to note that such a design can result in concentrated stresses at the anchoring points when external forces, such as seismic events, are at play. This may lead to potential structural damage due to anchor and concrete damage. For this reason, in this study, it selected an vertical hydrogen storage vessel based on site observations and created a 3D finite element model. Artificial seismic motions made following the procedures specified in ICC-ES AC 156, as well as domestic recorded earthquakes with a magnitude greater than 5.0, were applied to analyze the structural behavior and performance of the target structures. Conducting experiments on a structure built to actual scale would be ideal, but due to practical constraints, it proved challenging to execute. Therefore, it opted for an analytical approach to assess the safety of the target structure. Regarding the structural response characteristics, the acceleration induced by seismic motion was observed to amplify by approximately ten times compared to the input seismic motions. Additionally, there was a tendency for a decrease in amplification as the response acceleration was transmitted to the point where the centre of gravity is located. For the vulnerable components, specifically the sub-system (support columns and anchorages), the stress levels were found to satisfy the allowable stress criteria. However, the concrete's tensile strength exhibited only about a 5% margin of safety compared to the allowable stress. This indicates the need for mitigation strategies in addressing these concerns. Based on the research findings presented in this paper, it is anticipated that predictable load information for the design of storage vessels required for future shaking table tests will be provided.