• Title/Summary/Keyword: 진동안전기준

Search Result 123, Processing Time 0.025 seconds

Safety Evaluation Method for Ground Ammunition and Explosive Storage Facilities due to Underground Tunnel Blast (지하시설 굴착공사에 따른 탄약저장시설 안전성 평가방법 연구)

  • Park, Sangwoo;Kim, Kuk-Joo;Park, Young-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.4
    • /
    • pp.331-339
    • /
    • 2019
  • Recently, expansion of urban and social infrastructures is planned to go through the transfer of military facilities or crossing the infrastructures via underground tunnels. However, when crossing facilities such as ammunition and explosive storages, a high level of safety assessment is required to prevent an accidental explosion of ground ammunition. In this study, a case study was conducted to evaluate the effect of blasting for the construction of tunnel on the ground ammunition facilities. The design section of Sinansan train operated by the Korea Railroad Authority with agreement of the Ministry of National Defense was selected. For the purpose of this study, the vibration velocity due to explosion was predicted by using GTS-NX, a numerical analysis program. Through literature review, it was confirmed that the vibration velocity of 0.2cm/sec can be a safety evaluation standard. These safety evaluation indicators and procedures used in this study can be utilized as an index of safety evaluation in the planning of social infrastructures that cross the ammunition facilities in the future.

Practical Vibration Analysis of Deck Floor Slab (데크 바닥판 구조물의 실용적인 진동해석)

  • Kim, Gee-Cheol
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.18 no.1
    • /
    • pp.61-69
    • /
    • 2005
  • As long-span and light-weight deck floor slab are flexible and have low inherent damping, the significant floor vibration could be induced by residents' activities. These floor vibrations affect to safety and serviceability of building structures. So the vibration criteria are applied to the quality assessment of building structure. Therefore, the accurate vibration analysis should be performed for the correct assessment of deck floor slab. In this paper, practical analysis method with considering orthotropic rigidity of deck floor is proposed tot the accurate vibration analysis of dock floor slabs with form deck plates.

Investigation and Analysis of Regulations for the Safety of the Noise Barrier (방음벽 안전을 위한 기준 조사 및 분석)

  • Huh, Young;Kim, Heung-Sik
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.9
    • /
    • pp.730-734
    • /
    • 2003
  • For the noise reduction measures in a construction field or near the traffic line receiver is often the most economic measure in order to exclude the propagated sound. The dimension of the barrier is decided by the noise and construction design, and the constructive quality of a soundproof panel shall be secured in accordance with KS F4770 to guarantee the safety of sound barriers. In this paper the problems included in the KS F4770-1 that is the regulation for the metallic sound barrier of the absorption type are identified and it is suggested what to be corrected or improved. Through a series of the analyses, conclusions were reached that it is required to improve test methods in KS F4770-1 as well as to break down test loads for building more cost-effective sound barrier.

Investigation and Analysis of Regulations for the Safety of the Sound Barrier (방음벽 안전을 위한 기준 조사 및 분석)

  • Huh, Young;Kim, Heung-Sik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.219-223
    • /
    • 2003
  • For the noise reduction measures in a construction field or near the traffic line receiver is often the most economic measure in order to exclude the propagated sound. The dimension of the barrier is decided by the noise and construction design, and the constructive quality of a soundproof panel shall be secured in accordance with KS F4770 to guarantee the safety of sound barriers. In this paper the problems included in the KS F4770-1 that is the regulation for the metallic sound barrier of the absorption type are identified and it is suggested what to be corrected or improved. Through a series of the analyses, conclusions were reached that it is required to improve test methods in KS F4770-1 as well as to break down test loads for building more cost-effective sound barrier.

  • PDF

Experimental and Numerical Investigation of Sliding Response of Unconstrained Objects to Base Excitations (바닥진동에 의한 비구속 물체의 거동파악 실험과 수치해석 전산프로그램의 개발)

  • Lee, Sang Ho
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.3
    • /
    • pp.463-469
    • /
    • 2014
  • Safety related devices unconstrained temporally in the process of operation of nuclear power plants could be damaged by the sliding during seismic activity. In this study sliding response of unconstrained objects to the base excitations is studied experimentally and analytically. In experiments static and dynamic tests to determine the coefficient of friction and the shaking table experiments to verify the sliding response of the analytic results were conducted. Numerical solutions by solving the nonlinear differential equations of motion governing sliding were found by the computer program using the step by step acceleration method. The exact solutions of the sliding response to the simple forms of base excitations were found to verify the computer program developed in this study. Relative displacement envelopes were suggested as a colliding criteria of the unconstrained objects.

A Vibration Evaluation and Improvement Scheme for Open Test Blasting (노천시험발파의 진동평가와 개선방안)

  • Kim, Eung-Rok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.310-315
    • /
    • 2017
  • Although studies evaluating the effects of the blasting vibration on the adjacent structures from various angles have continued, cases of securing the safety of the adjacent buildings and researching the proper blasting method for the field condition by analyzing the vibration waveform of the measuring field while performing the open pit blasting are poor. Therefore, it is necessary to present a remedy for blasting pattern selection through test blasting that is appropriate for field conditions, and is economical and efficient. In this study, open pit blasting work was conducted based on the separation distance applied according to the standard blasting method by test blasting and the vibration regulation standard in the road expansion construction site to measure the blasting vibration value, and the vibration prediction equation by blasting methods was examined using a regression analysis computer program to calculate K, N, and R of the confidence level 95%. By setting the blasting allowed vibration standard of the test blasting target area to 0.3cm/sec, and the charring weight and blasting method by the separation distances according to the blasting vibration estimation equation of the open pit blasting guideline and the blasting vibration estimation equation of the test blasting were compared/analyzed, it was possible to identify the factors that increased the working expenses. In addition, the measurement and analysis of the adjacent structures during open pit blasting and the blasting vibration were performed after selecting the most adjacent structure to the open pit blasting spot to analyze the problems on the test blasting procedure and analysis method in the open pit blasting design/construction guidelines, which appeared in the process of completing open pit blasting construction, and a remedy is presented.

A Evaluation on the Effect of Vibration for the Application of PEMFC Stack to Unmanned Aircraft (고분자 전해질 연료전지 스택의 무인기 적용을 위한 진동 영향 평가)

  • KANG, JUN-YOUNG;OH, GUN-WOO;KIM, MIN-WOO;LEE, JUNG-WOON;LEE, SEUNG-KUK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.6
    • /
    • pp.587-595
    • /
    • 2018
  • Recently, research is being conducted to use a fuel cell as a power source of unmanned aircraft. However, safety standards about applying fuel cells to unmanned aircraft are insufficient. In this paper, to improve the safety of the fuel cells for unmanned aircraft is experimentally studied. For this reason, standards for safety of fuel cells were analyzed. And influence of vibration among the evaluation items related to the safety of the fuel cell for unmanned aircraft was discussed. In order to, at constant intervals, vibration was applied to the fuel cell, then the performance was measured, the measurement items were gas tightness, polarization curve, frequency response analysis (FRA). A total of 220 hours was experimented at 20 hour intervals. the result of vibration test, gas leakage rate was a maximum of -0.04826 kPa/min and Polarization curve reached a maximum of 1.0103 times of the initial value, the charge transfer resistance reached a maximum of 1.0104 times of the initial value. This research indicate that performance of fuel cell is affected by vibration and this study is expected to contribute to the safety of fuel cell for unmanned aircraft.

Application of Electronic Deck Charge Blasting Method to a Vertical Shaft Excavation (수직구 굴착시 전자뇌관을 이용한 Deck-Charge 발파 시공사례)

  • Kim, Jae-Hong;Kim, Hee-Do;Lee, Jun-Won;Kim, Gab-Soo;Son, Young-Bok;Kim, Jae-Hoon
    • Explosives and Blasting
    • /
    • v.31 no.1
    • /
    • pp.64-75
    • /
    • 2013
  • This case study deals with an excavation blasting carried out at "Sooseo-Pyeongtek ${\bigcirc}$-${\bigcirc}$ section construction site" in the vicinity of residential area. Originally, the sequential blasting (multi-stage blasting) using electric detonators was planed in this area. However, there was a concern that the sequential blasting method could increase the construction cost by delaying the construction period due to possible complaints from local residents. As an alternative, electronic deck blasting technique was taken in order to meet the ground vibration regulation (0.2cm/s, in apartment area) and to keep the construction schedule. The performance of the electronic deck charge blasting was two times better than the sequential blasting with electric detonators and the level of ground vibration was also within the regulatory value (0.2cm/s). In particular, it was shown that the use of electronic detonater eDevII, which was developed for tunnel, could provide more convenient and electrically safer working condition.

A Study on the Correlation between Underwater Noise and Ground Vibration (지반진동과 수중소음의 상관성 연구)

  • Park, Jung-Bong;Kang, Choo-Won;Lee, Chang-Won
    • Explosives and Blasting
    • /
    • v.31 no.1
    • /
    • pp.11-22
    • /
    • 2013
  • This study compared and analysed ground vibration, size of underwater background noise in fish farms and underwater object noise of blasting and obtained ground vibration prediction equation through a regression analysis and correlation equation between underwater object noises in order to predict degrees of underwater noise in blasting and organize underwater noise control regulations. Before the study, when background noise of fish and shellfish farms with different conditions was measured, levels of background noise were different according to environmental characteristics of each farm. Ground vibration which causes underwater noise was measured to obtain a correlation equation between ground vibration and underwater object noise. Therefore, if underwater noise is predicted for each construction with a use of a correlation and permissible standards appropriate for each condition are applied for design and construction, financial loss from damages to fish and shellfish caused by development of insufficient technological and engineering logic can be prevented and successful construction with safety of underwater creatures guaranteed can be achieved.

T/G Gear Box의 파손원인 조사

  • 심종성
    • Computational Structural Engineering
    • /
    • v.4 no.4
    • /
    • pp.14-23
    • /
    • 1991
  • T/G 가동중 발생한 Gear Box 파손원인을 조사하기 위하여 실시한 현장측정결과를 이용한 결과, 다음과 같은 사실을 알 수 있었다. 1) 현장 측정치와 구조해석 결과를 토대로 판단해 볼 때 본 연구대상 구조물의 구조상 문제는 없는 것으로 판단된다. 특히 측정된 진동변위를 여러기준과 비교해 볼 때 기계 가동시 구조물에 발생하는 진동은 사람이 감지할 정도에 속한다. 2) 본 연구대상 구조물과 기계의 진동수 차가 커 공진역을 벗어나므로 기계와 구조물이 공진을 일으킬 가능성은 없으며, 감쇠비에 따른 구조물의 동적응답에는 큰 변화가 없는 것으로 판단된다. 3) 구조물설계회사에서 사용한 구조해석 모델은 근사적 모델로서 구조해석 결과 안전한 값이 얻어졌다. 따라서 이 모델을 사용하여 기초설계를 실시할 경우 안전성 문제는 없는 것으로 판단되나, 다소 경제성이 문제가 되었을 것으로 사료된다. 4) 기계제작회사에서 제시한 해석자료의 불충분으로 기계제작회사의 구조해석 모형에 대해서는 충분한 검토를 실시할 수 없었으나 기계제작회사의 해석결과를 측정치와 비교해 볼 때 측정치를 훨씬 초과함을 알 수 있었다. 이는 해석모형 작성시 구조물과 하중의 실제 상황을 제대로 반영하지 못했기 때문으로 판단되며 따라서 해석결과는 타당성이 없어 보인다. 이상의 사실을 토대로 판단해 볼 때 Gear Box 파손의 주된 원인은 구조물의 결함이라기 보다는 기계 자체의 결함인 것으로 판단되나 기계에 대한 조사는 본 연구대상이 아니므로 이에 대한 검토는 실시하지 않았다.

  • PDF