• Title/Summary/Keyword: 진동성능시험

Search Result 388, Processing Time 0.053 seconds

Improvement and Operation of a Helicopter Tail-Fan Performance Test System (헬리콥터 테일팬 시험장치 개조 및 운용)

  • Lee, Je-Dong;Song, Keun-Woong;Kang, Hee-Jung;Sim, Jung-Wook;Kim, Seung-Bum
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11b
    • /
    • pp.41-44
    • /
    • 2005
  • This paper described improvement and operation of a 'Tail-Fan' anti-torque performance test system KARI (Korea Aerospace Research Institute) developed a 'Tail-Fan' anti-torque system of a helicopter and a performance test-rig to test the performance of the Tail-Fan. The test-rig was improved for full rotating test in 4300rpm(100%). Machinery and hydraulic parts ware changed to reduce vibration and to increase safety. To find the operation rotating speed for the performance test, vibration test were carried out rising accelerometers on tail gear box. The performance test conditions of the Tail-Fan to avoid a resonance were found from vibration test results. The Tail-Fan operation tests were performed safely frier to carry out performance test.

  • PDF

A Study on the Applicability of Adaptive Bang-Bang Control Algorithm for the Vibration Control of Multi-DOF Structure under Unexpected Large Earthquakes (과도한 기진력을 받는 다자유도계 구조물의 진동 제어를 위한 적응형 뱅뱅 제어 알고리듬의 유용성에 관한 연구)

  • 임채욱;정태영;문석준
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.1
    • /
    • pp.53-61
    • /
    • 2001
  • 구조물이 과동한 기진력을 받을 때에 구조물의 진동 제어를 위하여 적응형 뱅뱅 제어 알고리듬이 저자들에 의해서 제안된 바 있으며, 이 제어 알고리듬을 1자유도계의 시험 구조물에 적용하여 제어 성능을 실험적으로 확인하였다. 본 논문은 이의 연장으로서 제안된 적응형 뱅뱅 제어 알고리듬을 최상층에 유압식 농동질량 감쇠기가 설치된 다자유도계의 시험 구조물에 적용하여 이의 유용성을 확인하였다. 이를 통하여 제안된 적응형 뱅뱅 제어 알고리듬은 제어 및 전체 구조계의 안전성이 보장되는 가운데 과도항 외부의 기진력을 받는 다자유도계의 구조물의 진동을 제어함에 효과적임을 확인할 수 있었다.

  • PDF

Analysis on the Dynamic Behavior according to Suspension Structure of the Urban Railway Vehicle (전동차 현가구조에 따른 동적거동특성 분석)

  • Hur, Hyun-Moo;Noh, Hak Rak
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.617-623
    • /
    • 2020
  • Urban railroad vehicles carry many passengers and are the core of an urban railroad transportation system. Therefore, the dynamic performance of the vehicle must be ensured. Dynamic behaviors such as the vibration and ride comfort of railway vehicles are affected by the structure of the suspension system. We analyzed the dynamic behavior of a railway vehicle according to the suspension system of an urban railway vehicle, which is mainly operated in Korea. For two types of vehicles with different suspension structures, the vibration of the vehicles on railway tracks was measured, and dynamic behavior characteristics such as vibration, ride, and vibration reduction rate were analyzed. The result of the test shows that the vibration performance of the body is superior to that of B-bogie in the lateral direction and that of A-bogie in the vertical direction. Overall, the ride quality of the A-bogie car is superior to that of B-bogie. When analyzing the vibration attenuation rate of primary suspension system, the vibration attenuation performance of B-bogie with coil spring was superior to that of A-bogie with a conical rubber spring. The secondary suspension system has better vibration attenuation performance for A-bogie with air springs compared to coil springs.

Presentation of Performance Test Criteria for Denuclearization Verification Equipment Considering North Korea Environment (북한 환경을 고려한 비핵화 검증 장비의 성능 시험 기준 제시)

  • Ji-Young, Han;Su-Hui, Park;Yong-Min, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.71-77
    • /
    • 2023
  • The issue of North Korea's denuclearization is an global issue that transcends the North and South. It is necessary to prepare for the denuclearization process in preparation for the situation in which North Korea reveals its intention to denuclearize. In the process of North Korea's denuclearization, it is required to guarantee the normal operation of the denuclearization verification equipment. If a performance test criteria that takes into account the North Korean environment is established, it is highly likely that it will be used in the future denuclearization process. For this purpose, basic materials related to performance test standards were established through analysis of test standards such as international standards. After that, we established a performance test criteria. This includes high temperature, low temperature, humidity, vibration and shock tests. Through follow-up studies, validity of test criteria will be established through actual device testing.

Development and Performance Tests of the Waste Water Diffusers using Acoustic Resonance and Oscillatory Pulsation (음향공진과 맥진동 현상을 이용한 폐수처리용 산기관 개발 및 성능시험)

  • Hong, Suk-Yoon;Moon, Jong-Duck
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.6
    • /
    • pp.52-58
    • /
    • 1996
  • Using the acoustic resonances and oscillatory pulsations considered as the branch of wave technologies, the concept of the acoustic resonance diffusers for waste water treatment which maximize the oxygen transfer efficiency in gas-liquid two phase medium have been proposed, and studies for the principles and performance tests were accomplished. Besides, the design concepts for the low pressure Helmholtz resonator, cylinder and annular type reflection resonator and combined type resonance system have been implemented. The acoustic resonance energy which can speed up the mass transfer process increase the oxygen transfer efficiency, and periodic pulsations generated from the instability of air jet from nozzle make very small air bubbles. Then, the annular type jet resonator(AJR) applying these two principles successfully was evalulated as the most promising device and also the efficiency showing $20{\sim}30%$ better than conventional diffusers has been verified experimentally.

  • PDF

Dynamic Behaviors of Behavior Piles and Countermeasures to Improve Their Seismic Performance Using Shaking Table Tests (진동대 모형실험을 이용한 경사말뚝의 동적 거동 분석과 내진성능 향상을 위한 보강기법 개발)

  • Hwang Jae Ik;Lee Yong Jae;Han Jin Tae;Kim Myoung Mo
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.2
    • /
    • pp.105-111
    • /
    • 2005
  • Shaking table tests are performed to investigate the seismic behavior of the batter pile and to bring up the countermeasures to improve the seismic performance of the batter pile. First of all, this study demonstrates how batter piles and vertical piles behave under static lateral loadings. Secondly, the vulnerability of batter plies under dynamic lateral loadings is demonstrated showing the axial forces and bending moments mobilized at the pile heads during shaking table tests. Thirdly, countermeasures to overcome the vulnerability of behavior piles during earthquakes are pursued. The countermeasures investigated in this study include introduction of a rubber element at the pile head and the deck plate connection, and introduction of hinge connection. Finally, the slope of batter piles which induces the minimum pile forces during the dynamic loadings are investigated and found to be 8:3 (Vertical to Horizontal).

Analysis of Vehicle Dynamic Performance after Wheel Reprofiling (차륜 전삭에 따른 차량 동적성능 분석)

  • Hur, Hyunmoo;Ahn, Dahoon;Youn, Suksoon;Choi, Yongwoon
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.5
    • /
    • pp.565-575
    • /
    • 2016
  • Wheel reprofiling is frequently conducted to remove faults such as flange wear, flat areas, and cracks that occur in railway vehicle operation. We analyzed the dynamic performances of a vehicle before and after wheel reprofiling to grasp the influence of reprofiling on the dynamic behavior of the vehicle. We measured the wheel profile of the test vehicle and conducted a running test to analyze the vibration and comfort characteristics of the test vehicle. The result of the test indicated that vibration of the test vehicle after wheel reprofiling was reduced compared to that before wheel reprofiling. And, comfort level of the test vehicle after wheel reprofiling was improved by about 3dB laterally and vertically. Consequently, the positive effect of wheel reprofiling on the dynamic performance of vehicle was verified.

Design/Manufacturing/Test of Curved Actuator LIPCA Composed of Piezoelectric Ceramic and Fiber Composite Layers (압전 세라믹과 섬유복합재료 층으로 구성된 곡면형 경량 작동기 LIPCA의 설계/제작 및 성능시험)

  • Sin, Seok-Jun;Kim, Ju-Sik;Gu, Nam-Seo;Park, Hun-Cheol;Gwak, Mun-Gyu;Yun, Gwang-Jun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1268-1272
    • /
    • 2000
  • 본, 논문에서는 카본/에폭시, PZT 세라믹 박판, 글래스/에폭시 층으로 이루어진 곡면형 복합재료 작동기(LIPCA)의 설계, 제작 및 성능실험에 대한 연구 성과를 제시하고 있다. LIPCA의 큰 요점은 기존 THUNDER의 성능을 유지하면서 이를 경량화 하기 위하여 THUNDER의 금속 층을 상대적으로 가벼운 섬유 강화 복합재료로 대체하는 것이다. 이러한 경량화 작업으로 LIPCA는 기존 THUNDER 보다 약 $30{\sim}40%$ 정도의 무게를 감소시킬 수 있으며, 복합재료의 특성에 따라 설계의 유연성을 가질 수 있는 장점이 있다. 또한, 에폭시 수지를 사용함으로써 접착제 없이 평판 몰드에서 오토클레이브에서 $177^{\circ}C$로 경화되어, 탈형된 후 충분한 곡률을 형성하였다. 작동 성능 실험에서, LIPCA는 기존 THUNDER보다 작동변위가 향상됨을 보였다.

  • PDF

Vibratory Loads Reduction of a Rotor in Slow Descent using Higher Harmonic Control Technology (고조파제어(HHC) 기법을 이용한 저속 하강 비행중인 로터의 진동하중 억제에 관한 연구)

  • You, Younghyun;Jung, Sung Nam
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.6
    • /
    • pp.440-447
    • /
    • 2013
  • In this paper, a higher harmonic control (HHC) methodology is applied to find the optimum input scenario for the vibratory hub loads reduction. A comprehensive aeroelastic analysis code, CAMRAD II, is used to model the HART (Higher-harmonic-control Aeroacoustic Rotor Test) II rotor, and parametric study is conducted for the best HHC inputs leading to a minimum vibration (MV) condition. The resulting outcomes are compared with the earlier HART II test results. It is indicated that the control input adopted in the MV condition showed less satisfactory results. The new MV condition obtained in the present investigation can achieve 45% lower vibration level than the baseline uncontrolled condition. The optimum HHC input results lead to 3/rev harmonic input having $0.8^{\circ}$ amplitude and $350^{\circ}$ phase angle. About 5% reduction in the required power is possible but accompanies with the increase of vibration level.

A Study on the Comparison of Structural Performance Test and Analysis for Design Verification of Bimodal Tram Vehicle Made of Sandwich Composites (샌드위치 복합재 적용 바이모달 트램 차체의 설계검증을 위한 구조 성능 시험 및 해석적 비교 연구)

  • Ko, Hee-Young;Shin, Kwang-Bok;Jeong, Jong-Cheol
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.4
    • /
    • pp.518-525
    • /
    • 2009
  • This paper describes the evaluation of structural performance test and finite element analysis to verify the design of Bimodal Tram made of sandwich composites. The sandwich composite applied to vehicle structure was composed of a aluminum honeycomb core and WR580/NF4000 glass fabric/epoxy laminate composite facesheet. The load tests of vehicle structure were conducted for vertical load, compressive load, torsion and modal analysis according to JlS E 7105. The structural Integrity of vehicle was evaluated by the measurement of displacement, stress and natural frequency obtained from dial gauge, strain gauge and gravity sensor, respectively. And finite element analysis using ANSYS v11.0 was done to compare with structural test. The results showed that the displacement, stress and natural frequency were in an good agreement with those of structural analysis using the proposed finite element models.