Seismic Performance Evaluation of Unreinforced and ECC-jacketed Masonry Fences using Shaking Table Test (진동대실험을 사용한 비보강 및 ECC 자켓 보강 조적담장의 내진성능평가)

  • Yonghun Lee;Jinwoo Kim;Jae-Hwan Kim;Tae-Sung Eom;Sang-Hyun Lee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.182-192
    • /
    • 2023
  • In this study, the efficacy of Engineered Cementitious Composite(ECC) jacket for masonry fences subjected to lateral dynamic load was experimentally verified through a shaking table test, comparing it with the performance of an unreinforced masonry(URM) fence. Firstly, dominant frequencies, modal damping ratios and deformed shapes were identified through an impact hammer test. URM and ECC-strengthened fences with heights of 940mm and 970mm had natural frequencies of 6.4 and 35.3Hz, and first modal damping ratios of 7.0 and 5.3%, respectively. Secondly, a shaking table test was conducted in the out-of-plane direction, applying a historical earthquake, El Centro(1940) scaled from 25 to 300%. For the URM fence, flexural cracking occurred at the interface of brick and mortar joint(i.e., bed joint) at the ground motion scaled to 50%, and out-of-plane overturning failure followed during the subsequent test conducted at the ground motion scaled to 30%. On the other hand, the ECC-jacketed fence showed a robust performance without any crack or damage until the ground motion scaled to 300%. Finally, the base shear forces exerted upon the URM and ECC-jacketed fences by the ground motions scaled to 25~300% were evaluated and compared with the ones calculated according to the design code. In contrast to the collapse risk of the URM fence at the ground motion of 1,000-year return period, the ECC-jacketed fence was estimated to remain safe up to the 4,800-year return period ground motion.

Shaking Table Test of a Full Scale 3 Story Steel Frame with Friction Dampers (마찰형 감쇠장치가 설치된 실물크기 3층 철골프레임의 진동대 실험)

  • Bae, Chun-Hee;Kim, Yeon-Whan;Lee, Sang-Hyun;Park, Young-Pil
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.9
    • /
    • pp.862-873
    • /
    • 2007
  • Energy dissipation devices can be considered as an alternative for the seismic performance enhancement of existing structures based on the strengthened seismic design code. In this study, seismic response mitigation effects of friction dampers are investigated through the shaking table test of a full scale 3 story building structure. Frist, the bilinear force-displacement relationship of a structure-brace-friction damper system and the effect of brace-friction damper on the increase of frequency and damping ratio are identified. Second, frequency, displacement, and torque dependent characteristics of the friction damper are investigated by using harmonic load excitation tests. Finally, the shaking table tests are performed for a full scale 3 story steel frame. System identification results using random signal excitation indicated that brace-friction damper increased structural damping ratio and frequency, and El Centro earthquake test showed that brace-friction damper reduced the peak displacement and acceleration significantly. In particular, it was observed that the damping effect due to friction damper becomed obvious when the structure was excited by more intensive load causing frequent slippage of the friction dampers.

Experimental Study on Effect of Boiling Heat Transfer by Ultrasonic Vibration (초음파 진동이 비등열전달 과정에 미치는 영향에 관한 실험적 연구)

  • Na Gee-Dae;Oh Yool-Kwon;Yang Ho-Dong
    • Journal of Energy Engineering
    • /
    • v.15 no.1 s.45
    • /
    • pp.35-44
    • /
    • 2006
  • This study experimentally investigates effect of boiling heat transfer when ultrasonic vibration was applied. Under the wall temperature condition, temperature distribution in a cavity was measured during the boiling process and heat transfer coefficient of convection, sub-tooled boiling and saturated boiling states were measured with and without ultrasonic vibration, respectively. Also, the profiles of the pressure distribution in acoustic field measured by a hydrophone were compared with the augmentation ratios of heat transfer calculated by local heat transfer coefficient. Result of this study, heat transfer coefficient and augmentation ratio of heat transfer is higher with ultrasonic waves than without one. Especially, augmentation ratio of heat transfer is more increased the convection state than sub-cooled boiling and saturated boiling states. Acoustic pressure is relatively higher near ultrasonic transducer than other points where is no installed it and affects the augmentation ratio of heat transfer.

3-D Aeroelastic Model Test of a Cable-Stayed Bridge with a Main Span of 1,200m (주경간장 1,200m 사장교의 3차원 풍동실험)

  • Sin, Seung-Hwan;Kim, Yeong-Min;Gwak, Yeong-Hak;Lee, Hak-Eun
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.70-70
    • /
    • 2011
  • 사장교의 적용지간이 증가하여 초장대화하면서 구조안전성을 확보하기 위한 다양한 노력이 시도되고 있다. 본 연구에서는 현재까지 시도된 적이 없는 주경간 1,200m 사장교의 내풍안정성을 검토하기위하여 3차원공탄성 모형을 제작하고 풍동실험을 수행하였다.(그림1 참조) 실험대상 구조물은 내풍안정성 증대를 위해 유선형 박스거더를 채용하고 케이블이 거더와 함께 비틀림에 저항하도록 2면 케이블을 적용하였다. 구조적인 측면에서는 보강형 자중감소를 위해 전경간을 강박스로 계획하였으며 측경간에 부반력제어를 위한 Counter Weight을 적용하였다. 실험대상 구조물은 완성계, 가설계95%, 가설계50%, 가설계45%로 모형을 해체하면서 진행하였고 가설단계 별로 내풍케이블의 수량과 형상을 달리하여 내풍안정성 개선효과를 확인하고자 하였다. 3차원 풍동실험 결과 완성계에서 교량의 안전성에 심각한 문제를 발생시킬 수 있는 와류진동, 플러터, 버페팅과 같은 유해한 진동현상이 발견되지 않았으며, 시공중 내풍안정성 확보를 위하여 대상교량에 내풍케이블을 설치하고 내풍케이블의 수량 및 배치형상에 따른 진동제어 효과를 검토하였다. 본 실험은 현재 풍동실험 요소기술을 이용하여 1,200m급 사장교 풍동실험을 수행하였고 이에 따라 교량이 초장대화 되면서 스케일다운에 따른 보강형질량, 케이블 간격 등 실험모형 제작상 문제점을 확인 할 수 있었으며 이러한 경험을 토대로 향후 1,000m 이상급 초장대 사장교 내풍설계를 위한 기초자료로 활용이 가능할 것으로 사료된다.

  • PDF

Design and Fabrication of a Double Mode Filter with Thickness Vibration Mode of Piezoelectric Ceramic (압전세라믹의 두께 진동모드를 이용한 다중모드 필터의 설계와 제작)

  • 이승희;정이봉;노용래
    • The Journal of the Acoustical Society of Korea
    • /
    • v.17 no.3
    • /
    • pp.37-46
    • /
    • 1998
  • 본 연구에서는 압전 세라믹인 PZT를 이용하여 두께 진동모드의 다중모드 필터를 설계, 제작하였다. 다중모드 세라믹필터의 등가회로를 설계하였고, 이를 이용하여 설계변수 인 물성변수와 형상변수에 따른 필터전달특성의 경향을 분석하였다. 이를 바탕으로 10.7MHz의 중심주파수를 가지는 세라믹필터를 제작하였고, 설계변수 중에서 압전세라믹 기 판과 전극형상의 변화에 따른 필터의 전달특성의 변화를 실험적으로 검증하였다. 본 연구를 통한 경향분석결과는 다양한 진동모드와 다양한 주파수대를 가지는 다중모드 필터를 설계하 는데 있어서 유용한 도구로 사용될 수 있을 것이다.

  • PDF

Evaluation of the Soil-Structure Interaction of a MDOF Column Type Structure on Group Piles Based on the Large Scale 1g Shaking Table Test and the Numerical Analysis (대형 진동대 실험 및 수치해석을 이용한 다자유도 기둥 구조물과 군말뚝 기초의 지반-구조물 상호작용 평가)

  • Chae, Jonghoon;Yoon, Hyungchul;Ahn, Jaehun;Jung, Jongwon
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.4
    • /
    • pp.47-58
    • /
    • 2022
  • Many 1g shaking table tests with an SDOF structure supported by a single pile were performed to evaluate the soil-structure interaction (SSI) effect. Since most structures supported by group piles are MDOF structures with columns, the SSI effect is simulated using a large 1g shaking table test and numerical analysis. According to the results, the movement in the piles tends to increase with input acceleration and when the input frequency is similar to the natural frequency. Furthermore, the slope of the dynamic p-y curve remains constant regardless of the variation of acceleration and input frequency. According to the results of the dynamic p-y backbone curve and the moment of group piles, a center pile with a leading pile has more soil resistance than side piles with a trailing pile, and the effect of group piles is observed above the 7D center to center pile distance.

A Study on Dynamic Characteristics of Hybrid Pedestrian Cable Stayed Bridge by Impact Hammer Test (충격해머실험에 의한 하이브리드 보도사장교의 동특성에 관한 연구)

  • Chin, Won Jong;Kim, Young Jin;Choi, Eun Suk;Lee, Jungwhee
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.166-166
    • /
    • 2011
  • 한국건설기술연구원내에 세계 최초로 UHPC(초고성능 콘크리트)를 활용한 보도사장교를 설계 및 시공하여 공용중이다. 초고성능 콘크리트(UHPC, Ultra High Performance Concrete)는 기존의 콘크리트의 단점을 극복하기 위하여 강섬유 및 혼화재료를 사용하여 고강도화와 더불어 인장강도, 휨강도, 균열에 대한 저항성, 전단강도 및 내충격성을 대폭 개선시켜서 구조부재의 연성 및 강도를 확보하기 위해 개발된 것으로서 한국건설기술연구원이 독자적 연구를 바탕으로 UHPC를 개발하였고, KICT-UHPC의 특성을 충분히 반영한 보도사장교를 한국건설기술원내에 실구조물로 시공하였다. 한국건설기술연구원내 본관 1, 2동 연결 보도사장교(SUPER BRIDGE 1)의 진동실험을 통해 UHPC 보도사장교의 동특성(고유진동수 및 모드형상)을 평가하였다. 대상교량에는 보도사장교의 캔틸레버 구조 특성에 의해 발생하는 진동을 제어하기 위한 질량 264kg의 난간형 수직진동제어장치(TMD) 4대가 설치되어 있으며, 부가질량의 운동을 기계적으로 구속하거나 구속을 해제하여 TMD의 작동을 켜거나 끌 수 있도록 되어있다. TMD의 가동 및 정지시 동특성을 비교하는 정밀한 검증 실험을 통하여 TMD 설치에 의한 동특성의 변화도 평가하였다. 가진망치에 의한 충격실험으로부터 획득한 가속도 시간이력 데이터와 가진망치의 가진력 시간이력 데이터를 사용하여 주파수응답함수(FRF, frequency response function)를 계산하고, 이로부터 Super Bridge I의 동적모드형상과 고유진동수를 추출하였다. 1차 모드의 고유진동수는 TMD 정지시 2.2949 Hz, TMD 작동시 2.0996 Hz로서 8%정도 감소하였다. 충격해머에 의한 가진 실험을 통해 세계 최초로 시공한 UHPC 보도사장교의 진동특성과 관련한 신뢰성 있는 자료를 확보할 수 있었다.

  • PDF

Nonlinear Characteristics Evaluation of Tuned Liquid Damper with White Noise Amplitude (백색잡음 하중 크기에 따른 TLD의 비선형 특성 평가)

  • Woo, Sung-Sik;Lee, Sang-Hyun;Choi, Ki-Young;Chung, Lan;Park, Tae-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.21 no.2
    • /
    • pp.135-143
    • /
    • 2008
  • In this study, it was investigated for dynamic nonlinear characteristics using dynamic data obtained by shaking table test. The design of Tuned Liquid Damper(TLD) has limitation to plan based on Tuned Mass Damper(TMD) analogy and linear wave theory. Also, while there are many studies regarding properties of TLD under harmonic load, there are not estimated for dynamic non-linear characteristics of TLD under the load that is not governed by particular frequency like a white noise. This paper investigated dynamic non-linear characteristics of TLD varied with load amplitude using a white noise and suggested equations that can estimate damping ratio, natural frequency ratio and effective mass ratio of TLD.

Pounding Characteristics of a Bridge Superstructure on Rubber Bearings (교량 상부구조물의 탄성받침 설치에 따른 충돌특성 분석)

  • Choi, Hyoung-Suk;Kim, Jung-Woo;Gong, Yeong-I;Cheung, Jin-Hwan;Kim, In-Tae
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.15 no.4
    • /
    • pp.13-21
    • /
    • 2011
  • Seismic structure pounding between adjacent superstructures may induce the destruction of pier and bridge superstructures and cause local damage that leads to the collapse of the whole bridge system. The pounding problem is related to the expansion of joints, gap distance and seismic response of the abutments. In this research, methods of the contact element approach, the linear spring model, the Kelvin-Voigt model and the Hertz model were studied to analyse the pounding characteristics. The shaking table test for a model specimen such as a bridge superstructure with elastomeric bearings was performed to evaluate the contact element approach methods. Relationships between the time history response from the numerical analysis results and the measured response from the shaking table test are compared. The experimental results were not well matched with the numerical analysis results using the existing pounding stiffness models. Therefore, in this study, coefficients are proposed to calculate the appropriate pounding stiffness ratio.

Strain Analysis of Longitudinal Reinforcing Steels of RC Bridge Piers Under Shaking Test (진동대 실험에 의한 RC교각의 주철근 변형률 분석)

  • Hong, Hyun-Ki;Yang, Dong-Wook;Chung, Young-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.93-96
    • /
    • 2008
  • The near fault ground motion(NFGM) is characterized by a single long period velocity pulse of large magnitude. NFGM's have been observed in recent strong earthquakes, Turkey Izmit (1999), Japan Kobe(1995), Northridge(1994), etc. These strong earthquakes have caused considerable damage to infrastructures because the epicenter was close to the urban area, called as NFGM. Extensive research for the far fault ground motion(FFGM) have been carried out in strong seismic region, but limited research have been done for NFGM in low or moderate seismic regions because of very few records. The purpose of this study is to investigate and analyze the effect of near-fault ground motions on RC bridge piers without lap-spliced longitudinal reinforcing steels. The seismic performance of two RC bridge piers under near-fault ground motions was investigated on the shake table. In addition, Two of four identical RC bridge piers were tested under a quasi-static load, and the others were under a pseudo-dynamic load. The respectively two RC bridge pier is comparatively subjected to Pseudo-dynamic loadings and Quasi-Static loadings. This paper indicated that more gives bigger ultimate strain of longitudinal steels to be fractured at bigger PGA motion.

  • PDF