• Title/Summary/Keyword: 진동대 시험

Search Result 141, Processing Time 0.028 seconds

Evaluation of Seismic Performance of Valve Chamber System by Shaking Table Tests (진동대 실험을 통한 밸브실 시스템의 내진성능 평가)

  • Young-Soo Jeong;Kyeong-Seok Lee;Jin-Seok Yu;Hyung-Chae Jeong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.1
    • /
    • pp.46-52
    • /
    • 2024
  • The structural safety of expansion joints for piping systems has been drawing attention owing to ruptures and leaks of water pipes caused by earthquakes and road subsidence at soft ground. In general, metal bellows are installed as expansion joints to prevent various damages in the piping system. In this study, the seismic performance of a valve chamber system was evaluated by performing earthquake shaking table tests. To validate the benefits to structural safety of metal bellows in connecting steel pipes to valve chambers, the seismic tests were conducted on expansion joints (bellows) and general pipping, and the results were compared for durability. Strain gauges were attached to measure the effects of the input motion. As a result of the shaking table test, it was confirmed that the strain of the valve chamber structure and inflow or outflow steel pipes were decreased in 1/100, 1/20 by applied to the expansion joints.

Experimental Vibration Analysis of Vehicle Body-Engine Systems by Transfer Function Synthesis Method (전달함수합성법에 의한 차체-엔진계의 실험적 진동해석)

  • 정의봉;안세진;김원영
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.289-295
    • /
    • 1995
  • 구조물의 동적부하에 대한 동적변형 응답을 정확히 예측하고, Over Design이나 Under Design이 아닌 합리적인 설계방안의 개발은 중요한 과제이다. 동적강도해석이나 소음 승차감과 같은 진동 및 충격에 기인하는 제반 문제를 복잡한 구조물을 대상으로 합리적으로 처리하기 위한 Dynamic Design Analysis는 높은 신뢰성의 추구와 더불어 필요불가결한 기술이 되고 있다. 동적해석 방법으로는 현재 유한요소법이 널리 사용되고 있으며 여러 종류의 범용 프로그램들이 보급되어 있는 실정이다. 그러나 특히 동적문제에 있어서는 형상이나 거동이 복잡한 구조물의 경우, 또는 차량의 차체와 같이 많은 장착물이 부착된 경우에는 유한요소법의 적용이 곤란하여, 지금까지 대처할 수 있는 유용한 방법이 없었다. 따라서 비교적 용이하고 간단하게 적용가능한 진동실험을 기초로 한 구조물의 동적 응답해석 및 설계 방안의 개발이 필요하다. 본 연구에서는 진동시험으로 얻어진 부분구조물의 응답특성과 결합특성으로부터 결합 후의 응답특성을 예측할 수 있는 방법을 전달함수합성이론을 기초로하여 프로그래밍 package화 한다. 그리고 평판구조물에 대하여 진동시험과 컴퓨터 시뮬레이션을 통하여 개발된 방법의 타당성을 검증한다. 또한 실제 차량에서 차체만의 진동시험과 엔진의 자유진동시험에 의한 시험데이터로부터 차체와 엔진이 마운트 결합된 후의 진동특성을 예측한다. 진동시험시에 입력과 출력에 노이즈가 필연적으로 혼입되어 주파수응답함수의 크기(magnitude)와 위상(phase)을 왜곡시킨다. 특히 위상의 왜곡은 복소수연산을 하는 전달함수합성법의 결과에 중요한 영향을 미치게 된다. 본 연구에서는 데이타 획득시 입력과 출력의 시간지연으로 생기는 위상왜곡을 보정하는 방법을 제시하고, 그 개선 정도를 조사한다.는 소견의 확실도로서 가능성을 표현한 것이다. 예를 들면, 진동진폭 스펙트럼상에 2X 성분이 상당히 크게 나타나 정렬불량의 가능성이 0.7 정도라고 판정하는 것 등은 이러한 수치적진리치를 이용하는 방법이다. 그러나 상기의 수치적 표현만으로는 확실도를 한개의 수치로서 대표하게 하는 것은 진단의 정밀도에 문제가 있을 것으로 생각된다. 따라서 언어적진리치가 도입되어 [상당히 확실], [확실], [약간 확실] 등의 언어적인 표현을 이용하여 애매성을 표현하게 되었다. 본 논문에서는 간이진단 결과로부터 추출된 애매한 진단결과중에서 가장 가능성이 높은 이상원인을 복수로 선정하고, 여러 종류의 수치화할 수 없는 언어적(linguistic)인 정보ㄷㄹ을 if-then 형식의 퍼지추론으로 종합하는 회전기계의 이상진단을 위한 정밀진단 알고리즘을 제안하고 그 유용성을 검토한다. 존재하여도 모우드 변수들을 항상 정확하게 구할 수 있으며, 또한 알고리즘의 안정성이 보장된 것이다.. 여기서는 실험실 수준의 평 판모델을 제작하고 실제 현장에서 이루어질 수 있는 진동제어 구조물에 대 한 동적실험 및 FRS를 수행하는 과정과 동일하게 따름으로써 실제 발생할 수 있는 오차나 error를 실험실내의 차원에서 파악하여 진동원을 있는 구조 물에 대한 진동제어기술을 보유하고자 한다. 이용한 해마의 부피측정은 해마경화증 환자의 진단에 있어 육안적인 MR 진단이 어려운 제한된 경우에만 실제적 도움을 줄 수 있는 보조적인 방법으로 생각된다.ofile whereas relaxivity at high field is not affected by τS. On the other hand, the change in τV does not affect low field profile but strongly in fluences on bot

  • PDF

A Vibration Evaluation and Improvement Scheme for Open Test Blasting (노천시험발파의 진동평가와 개선방안)

  • Kim, Eung-Rok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.310-315
    • /
    • 2017
  • Although studies evaluating the effects of the blasting vibration on the adjacent structures from various angles have continued, cases of securing the safety of the adjacent buildings and researching the proper blasting method for the field condition by analyzing the vibration waveform of the measuring field while performing the open pit blasting are poor. Therefore, it is necessary to present a remedy for blasting pattern selection through test blasting that is appropriate for field conditions, and is economical and efficient. In this study, open pit blasting work was conducted based on the separation distance applied according to the standard blasting method by test blasting and the vibration regulation standard in the road expansion construction site to measure the blasting vibration value, and the vibration prediction equation by blasting methods was examined using a regression analysis computer program to calculate K, N, and R of the confidence level 95%. By setting the blasting allowed vibration standard of the test blasting target area to 0.3cm/sec, and the charring weight and blasting method by the separation distances according to the blasting vibration estimation equation of the open pit blasting guideline and the blasting vibration estimation equation of the test blasting were compared/analyzed, it was possible to identify the factors that increased the working expenses. In addition, the measurement and analysis of the adjacent structures during open pit blasting and the blasting vibration were performed after selecting the most adjacent structure to the open pit blasting spot to analyze the problems on the test blasting procedure and analysis method in the open pit blasting design/construction guidelines, which appeared in the process of completing open pit blasting construction, and a remedy is presented.

Dynamic Characteristics and Isolation Performance of Isolation Table System (면진 테이블 시스템의 동적 특성 및 면진성능)

  • ;;;Kurabayashi
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.4
    • /
    • pp.67-74
    • /
    • 2001
  • Structural engineers lately have an interest in the safety for equipments and facility in buildings subjected to earthquake. The stability of cultural assets was not considered for the earthquake induced vibration, while the integrity of structure has been considered through the resistant earthquake design. The purpose of this study aimed to analyze the behavior of isolation device named as \"Isolation table system\" and to evaluate its isolation performance through the experiment study. Isolation table is one of isolation systems to reduce the vibration which was transferred from slab to exhibition table. Experimental result shows that isolation table can reduce the vibration by 80-90% and its behavior is very stable within its maximal stroke.al stroke.

  • PDF

A Study on the Step-Up Converter with the New Topology Method (내구성이 개선된 발전용 가스터빈 온도센서 개발에 관한 연구)

  • Lee, Young-Jun;Jung, Hai-Young
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.6
    • /
    • pp.1175-1186
    • /
    • 2020
  • In this study, the problem is analyzed, and methods of improvement are presented. For evaluating the performance of the proposed EGT sensor, a complex environment test equipment has been developed to test both high temperature and vibration conditions at the same time. This equipment evaluates the accuracy and response time of the EGT sensor. In the results of the comparison test of the complex environment test equipment of heat and vibration, the existing sensor showed a carbonization problem, and the proposed sensor showed no problem. Therefore, it is expected that the improved EGT sensor will be able to be applied to various industrial fields, including gas turbines for power generation.

Shaking Table Test of Isolated EDG Model (면진된 모형 비상디젤발전기의 지진응답 실험)

  • Kim, Min-Kyu;Choun, Young-Sun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.3 s.55
    • /
    • pp.33-42
    • /
    • 2007
  • In this study, for research on an improvement of the seismic safety of an EDG system, a small scale EDG system was manufactured. For the isolation system, the Coil Spring-Viscous Damper systems were selected. For the shaking table test, 3 kinds of seismic motions were selected which had different frequency contents. In this study, the isolation effects were different and they depended on the input seismic motion. In the case of an NRC earthquake which had low fiequency contents, the isolation effects of the horizontal direction were 20%. But for the seismic motions which had high fiequency contents, the isolation effects were $50{\sim}70%$. In the case of the vertical direction, poor isolation effects were observed. It was because the design properties and the real properties of the isolation system were a little different.

Comparisons on the Interface Shear Strength of Geosynthetics Evaluated by Using Various Kinds of Testing Methods (다양한 시험법에 의해 산정된 토목섬유 사이의 접촉면 전단강도 비교)

  • Seo, Min-Woo;Oh, Myoung-Hak;Yoon, Hyun-Suk;Park, Jun-Boum
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.2C
    • /
    • pp.73-80
    • /
    • 2006
  • The shear behavior of four different interfaces consisting of four types of geosynthetics was investigated, and both static and dynamic test for the geosynthetic interfaces were conducted. The monotonic shear experiments were performed by using an inclined board apparatus and large direct shear device. The interface shear strength obtained from the inclined board test was compared with calculated values from large direct shear tests. The comparison results indicated that direct shear tests show high possibility to over-predict the shear strength in the low normal stress range where direct shear tests are not performed. Curved failure envelopes were also obtained for interface cases where two static shear tests were conducted. By comparing the friction angles measured from three tests, i.e. direct shear, inclined board, and shaking table test, it was found that the friction angle might be different depending on the test method and normal stresses applied in the research. Therefore, it was concluded that the testing method should be determined carefully by considering the type of loads and the normal stress expected in the field with using the geosynthetic materials installed in the site.

Development of an Analysis Model for UPS System of LNG Receiving Terminal Facilities (천연가스 생산기지 내 UPS시스템의 해석모델 개발)

  • Kook, Seung-Kyu;Hong, Seong-Kyeong;Kim, Joon-Ho;Choi, Won-Mog;Park, Young-Ho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.6
    • /
    • pp.539-545
    • /
    • 2016
  • UPS system in the liquefied natural gas(LNG) receiving terminal is one of the fundamental equipment that need to sustain operation during earthquake. In this study, modal identification test of UPS system was performed based on IEEE Std. 693-2005 and natural frequencies and modal damping, mode shapes had been identified. In addition, tri-axial time history test was performed to check the behavior and stress of the equipment during earthquake. Eigenvalue analysis was performed and analysis model was modified by reflecting the results of the test. Static analysis by dead weight and response spectrum analysis were performed to compare the combined stresses with the stress results of test. Dynamic characteristics and combined stresses under seismic load condition of the improved analysis model were similar to the test results and in this regard the compatibility was proved.

Structural Damping Ratio of Steel Plate Concrete(SC) Shear Wall at the Low Stress Level Identified by Vibration Test (진동시험을 통한 강판콘크리트(SC) 전단벽의 저응력수준에서의 구조 감쇠비 규명)

  • Cho, Sung Gook;So, Gihwan;Kim, Doo Kie;Han, Sang Mook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.2
    • /
    • pp.255-264
    • /
    • 2015
  • Steel plate concrete (SC) structure has been developed as a new structural type. Rational damping value shall be determined for the seismic design of SC structure. This study evaluated damping ratio of SC structure through experiments. For the study, a SC shear wall specimen was constructed and dynamically tested on the shaking table. Acceleration time history responses measured from testing were converted to the transfer functions and analyzed by using experimental modal analysis technique. The structural damping ratio of the specimen was identified as 4% to critical. Considering the shaking table test was performed at the excitation level corresponding to the low stress level of the specimen, 4% could be suggested as a structural damping for design of SC structure for operating basis earthquake.

Seismic Performance Evaluation of Unreinforced and ECC-jacketed Masonry Fences using Shaking Table Test (진동대실험을 사용한 비보강 및 ECC 자켓 보강 조적담장의 내진성능평가)

  • Yonghun Lee;Jinwoo Kim;Jae-Hwan Kim;Tae-Sung Eom;Sang-Hyun Lee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.182-192
    • /
    • 2023
  • In this study, the efficacy of Engineered Cementitious Composite(ECC) jacket for masonry fences subjected to lateral dynamic load was experimentally verified through a shaking table test, comparing it with the performance of an unreinforced masonry(URM) fence. Firstly, dominant frequencies, modal damping ratios and deformed shapes were identified through an impact hammer test. URM and ECC-strengthened fences with heights of 940mm and 970mm had natural frequencies of 6.4 and 35.3Hz, and first modal damping ratios of 7.0 and 5.3%, respectively. Secondly, a shaking table test was conducted in the out-of-plane direction, applying a historical earthquake, El Centro(1940) scaled from 25 to 300%. For the URM fence, flexural cracking occurred at the interface of brick and mortar joint(i.e., bed joint) at the ground motion scaled to 50%, and out-of-plane overturning failure followed during the subsequent test conducted at the ground motion scaled to 30%. On the other hand, the ECC-jacketed fence showed a robust performance without any crack or damage until the ground motion scaled to 300%. Finally, the base shear forces exerted upon the URM and ECC-jacketed fences by the ground motions scaled to 25~300% were evaluated and compared with the ones calculated according to the design code. In contrast to the collapse risk of the URM fence at the ground motion of 1,000-year return period, the ECC-jacketed fence was estimated to remain safe up to the 4,800-year return period ground motion.