• Title/Summary/Keyword: 진단 표지

Search Result 248, Processing Time 0.029 seconds

Random Amplified Polymorphic DNA-PCR Analysis for Identification of Bacillus anthracis (탄저균의 Random Amplified Polymorphic DNA-PCR 분석)

  • 김성주;박경현;김형태;조기승;김기천;최영길;박승환;이남택;채영규
    • Korean Journal of Microbiology
    • /
    • v.37 no.1
    • /
    • pp.56-60
    • /
    • 2001
  • Molecular typing of Bacillus anthracis has been extremely difficult due to the lack of polymorphic DNA markers. Aiming to develop a DNA marker specific for Bacillus anthracis and to be able to discriminate this species from Bacillus genus, we applied the random amplified polymorphic DNA (RAPD)-PCR. We have identified B. anthracis from various Bacillus species. The analysis performed by RAPD clearly demonstrated substantial genetic variations among Bacillus species. This type of analysis is an easy, quick and highly discriminatory technique that may help in diagnosis of anthrax.

  • PDF

야간에 등부표의 시인성을 높이는 윤곽표시조명의 개발

  • 김종구;박대원
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2022.11a
    • /
    • pp.31-33
    • /
    • 2022
  • 등부표는 소형 어선을 포함한 선박의 항로표지에 중요한 역할을 한다. 그러나 야간에 어두워지면 해상에 설치된 등부표의 위치나 번호판 식별이 어려워 소형 어선이나 선박이 등부표에 가까이 접근하는 경우 등부표를 미처 발견하지 못하고 충돌하여 선박이 파손되거나 인명사고가 발생한다. 이 연구에서는 소형 어선이나 선박이 야간에도 등부표의 위치와 번호판을 쉽게 식별할 수 있도록 등부표에 조명장치를 구비하여 충돌사고의 예방과 항로표지서비스를 향상시키는 방법을 분석하고 고안하여 태양광전원을 이용한 방수형 LED조명과 통신모듈IoT를 결합하여 원격디밍 RGB제어 및 조명자가진단기능을 갖추어 야간에 시인성을 높이는 등부표의 윤곽표시조명을 개발하였다.

  • PDF

허혈성 심질환의 자기공명 영상 진단

  • 최영희
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.1
    • /
    • pp.5-20
    • /
    • 2002
  • 허혈성 심질환 환자의 평가도구로서 MRI의 역할이 확대된 데에는 소위 "one-stop shop"이라는 통합적 심장검사법의 개발이 계기가 되었다. 즉 한 번의 MRI 검사로서 심실벽운동을 평가하여 심근의 기능과 예비능을 측정하여 만성 심근경색을 평가할 수 있고, 심근의 관류를 평가할 수 있고, 관동맥의 혈류 예비능과 심근의 viability를 평가하고, 관동맥 조영술을 통해, 수술 후의 우회로 평가 및 관동맥의 협착 여부의 진단이 가능한 프로토콜이 MRI장비마다 각각 개발되어 보급되고 있다. 하드웨어와 소프트웨어의 개발과 지속적인 연구를 통해서 MRI는 허혈성 심질환의 진단적 검사로서 기존의 다른 검사들과 비교하여 높은 시간적, 공간적 해상력으로 정확한 구조와 기능의 평가를 제공할 수 있는 가장 유용한 검사가 될 것으로 사료된다 특히, MR 관동맥조영술, 심근관류검사, 심근 표지법, dobutamine 부하검사, viability 평가, plaque characterization, MR spectroscopy 분야에서 현재 활발히 연구가 진행되고 있으며 향후 임상적용이 확대될 것으로 예상된다.

  • PDF

Clinical Significance of Creatine Kinase MB mass and Cardiac Troponin I as a Marker of Perioperative Myocardial Infarction After Coronary Artery Bypass Grafting (관상동맥 우회술 후 심근경색의 표지자로서 Creatine Kinase MB 농도와 Cardiac Troponon I의 임상적 의의)

  • 이재진;김응중;이원용;신윤철;지현근
    • Journal of Chest Surgery
    • /
    • v.35 no.1
    • /
    • pp.27-35
    • /
    • 2002
  • Background: A perioperative myocardial infarction(PMI) is one of the major complications after CABG. Among diagnostic methods of PMI, CK-MB activity assays have been increasingly replaced by CK-MB mass assays, which have more sensitive, simple measurement. Also, new cardiac-specific and -sensitive marker, cardiac troponin I(cTnl), has been shown to be a marker of myocardial infarction. We report our evaluation of clinical significance of CK-MB mass and cTnl as a marker of PMI after CABG. Material and Method: We studied 32 patients who underwent CABG at Kangdong Sacred Hospital between April 2000 and April 2001. Postoperative serum CK-MB activity level, serum CK-MB mass, cTnl, electrocardiogram, echocardiogram, and clinical data were recorded prospectively The diagnosis of PMI was defined as positive 2 among 3 or all of the following , by a new Q wave on the electrocardiogram, by serum CK-MB activity higher than 200 lU/L within 72 hours after operation, and by new regional wall motion abnormality on the echocardiogram. Result: After CABG, 3 patients had sustained a PMI according to current diagnostic criteria. As serum CK-MB activity time course, a level of CK-MB activity 12 hours after CABG had very linear correlated significance with serum CK-MB mass 24hours(R=0.946) and cTnl 48 hours(R=0.933) after CABG(p=0.000). As we used a receiver operating characteristics curve(ROC curve) for a diagnostic cutoff value in patients with PMI, serum CK-MB mass levels higher than 30.05 ug/L 24 hours after CABG detected the presence of PMI with an area under the ROC curve of 1.0, a sensitivity of 100%, a specificity of 100%, a positive predictive value of 100%, and a negative predictive value of 100%. Also serum cTnl levels higher than 17.15 ug/L 48 hours after CABG detected the presence of PMI with an area under the ROC curve of 0.98, a sensitivity of 100%, a specificity of 96.6%, a positive preclictive value of 75%, and a negative predictive value of 100% Conclusion: We concluded that both the measurement of CK-MB mass and cTnl are the easier, accurate methods as a diagnostic marker of PMT after CABG, also as a proposal of diagnostic cutoff value enables to an early detection of PMI. However, a 1arger number of patient will be needed because of statistic limitation that a small number of participating patients, a small number of PMI.

A Study on the Sediment Transport using Radioisotope Tracer (방사성동위원소 추적자를 이용한 표사이동 추적실험)

  • Choi Byung-Jong;Jung Sung-Hee;Kim Jong-Bum;Lee Jong-Sup
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.16 no.3
    • /
    • pp.162-170
    • /
    • 2004
  • On the basis of the radiotracer technology and the related equipments which have been developed for its industrial application through the nuclear long-term research project, a radiotracer study on sediment transport was carried out as a part of the development of the radiotracer technology for a coastal environment. The crystalline material doped with iridium having a similar composition and specific gravity as those of the bedload sand collected from the research area was produced by the oxide-route method. A radioisotope container was specially designed to inject the radiotracer from 1 m above the sea bedload without radioactive contamination during the transport from the nuclear reactor at KAERI. The position data from the DGPS and the radiation measurement data were collected concurrently and stored by means of the application software programmed with the LabVIEW of the National Instrument. The position data was reprocessed to represent the real position of the radiation probe under water and not that of the DGPS antenna on board. The time dependency of the spatial distribution of the sediment was studied in the area through three tracking measurements after the iridium glass was injected. This trial application showed the potential of the radiotracer technology as an important role for maintaining and developing the coastal environment in the future.

Studies on the Biological Behaviors of Taxol Derivatives (Taxol 유도체들의 생물학적 거동에 관한 연구)

  • Awh, Ok-Doo;Yoo, Dae-Wung;Im, Sang-Moo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.4
    • /
    • pp.440-451
    • /
    • 1997
  • This study was designed to prospect the $^{111}In$-labelled paclitaxel as tumor imaging agent. In order to provide a taxol molecule with a functional group which is able to chelate In-111, taxol-DTPA conjugate and 2'-hemisuccinyltaxol were synthesized by esterification of taxol at C-2'on C-13 carbon with DTPA anhydride and succinic anhydride, respectively. Synthesis yield of the taxol derivatives was 34% for taxol-DTPA and 80% for 2'-hemisuccinyltaxol. Cytotoxicity of the taxol derivatives were measured by MTT method toward cell lines HT29, B16, P388, and CT26. The cytotoxic activities of the taxol derivatives were maintained, although less active than taxol. Radiolabelling of the taxol derivatives were proceeded directly with $^{111}InCl_3$ or indirectly with $^{111}In$-citrate(ligand-exchange method). The ligand-exchange method was not suitable because some precipitates appeared during the reaction. On the contrary, by direct radiolabelling method, we were able to obtain taxol-DTPA-$^{111}In$ in 100% radiochemical yield. However, 2'-hemisuccinyltaxol was not labelled by both methods. Yield and radiochemical purity of the radiolabelled com-pound were determined by HPLC, paper chromatography and instant thin layer chromatography. Taxol-DTPA-$^{111}In$ was characterized to be hydrophilic by lipophilicity test, and nearly non-adhesive to HT29, B16, P388, and CT26 by cell binding affinity test. Binding affinity of the taxol-DTPA-$^{111}In$ complex to serum proteins was also examined by protein precipitation with 30% trichloroacetic acid. The results showed that 30% of the taxol-DTPA-$^{111}In$ complex binds with serum proteins.

  • PDF

Multiple Genetic Marker Analysis with Using Quantitative RT-PCR in Gastric Cancer (위암에서 정량적 역전사 중합효소연쇄반응을 이용한 다중 표지자 분석)

  • Yoo, Moon-Won;Lee, Hyuk-Joon;Choi, Soo-Min;Yu, Ji-Eun;Hur, Keun;Kim, Young-Kook;Yang, Han-Kwang
    • Journal of Gastric Cancer
    • /
    • v.7 no.2
    • /
    • pp.59-66
    • /
    • 2007
  • Purpose: This study was aimed at evaluating the diagnostic validity of peritoneal dissemination of gastric cancer cells by performing multiple genetic marker analysis via quantitative reverse transcriptase-polymerase chain reaction (RT-PCR) in gastric cancer cell lines and gastric cancer tissues. Materials and Methods: Quantitative RT-PCR was performed on 12 human gastric cancer cell lines and 10 gastric cancer tissues with four mRNAs of carcinoembryonic antigen (CEA), Cytokeratin 20 (CK20), dopa decarboxylase (DDC), and L-3-phosphoserine phosphatase (L3PP). Results: Out of the 12 human gastric cancer cell lines we tested, CEA was overexpressed in four cell lines (33%), CK20 in one (8%), DDC in six (50%) and L3PP was expessed in all the lines (100%). Out of the 10 gastric cancer tissues we tested, CEA was overexpressed in nine tissues, CK20 in eight, DOC in nine and L3PP was overexpressed in all the tissues. L3PP was overexpressed in all the gastric cancer cell lines and tissues, but the levels of overexpression were lower than those of CEA and DDC. Conclusion: Multiple genetic marker analysis can compensate for the weak points of single marker analysis when testing gastric cancer, and three mRNAs of CEA, DDC and L3PP can be used as candidate genes.

  • PDF

Studies on the Formation of Pyrophosphate-$^{99m}T_c$ complex

  • Kim, Jae-Rok;Awh, Ok-Doo
    • Nuclear Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.19-28
    • /
    • 1980
  • An instant labelling technique for lyophilized pyrophosphate with $^{99m}$Tc is described labelling yield of about 90% is obtained at the pH range 3.5-5.5 on reconstitution with sodium pertechnetate-$^{99m}$ Tc solution. The final product is controlled by a modified two dimensional paper chromatography using 85% methanol and 0.85% saline, and biodynamic investigations are performed on white mice. Generally, the less amount of stannous chloride is used. the higher labelling yield is obtained. The molar ratio of pyrophosphate to stannous chloride of 10 : 1 ~ 50 : 1 is sufficient. The more amount of reduced unbound $^{99m}$Tc is injected, the more radioactivity is incorporated in the liver. Thus. the cause of the false bone-imaging is attributable to the presence of reduced unbound $^{99m}$Tc which is known to be well adsorbed to oxidized tin colloidals. The maximum uptake ratio of bone: liver in mice, in weight basis, 35 : 1 is achieved in lime of 60 min. or so. Tile preparation is suitable for clinical investigations on patients with bone diseases.iseases.

  • PDF

공진반사광 바이오센서를 이용한 심근경색 마커 감지 기술

  • Heo, Cheol;Kim, Bong-Gyu;Kim, Wan-Jung;Hong, Jong-Cheol;A, Chil-Seong;Kim, Sang-Hyeop;Seong, Geon-Yong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.127-127
    • /
    • 2014
  • 인체 내 소량의 생체성분(혈액, 소변 등)을 감지하는 바이오센서 기술은 질병 진단뿐만 아니라 예방 및 관리로 의료서비스 확대, 개인 맞춤형 진료 및 의료비 감소 효과를 가져올 수 있는 기술이다. 광바이오센서는 광학적인 측정방법을 이용하여 다양한 생화학물질들의 상호 반응을 검출해 낼 수 있는 바이오센서로 현재 활발하게 연구가 진행되고 있다. 광 바이오센서는 생체성분 내에 존재하는 전하를 가진 많은 이온들 및 Salt 농도 등에 영향을 받지 않기 때문에 나노 와이어를 이용한 FET (field-effect transistor)형 바이오센서에 비해 많은 장점을 가지고 있다. 일반적으로 광 바이오센서는 형광물질, 인광물질, 발색물질, 방사선 물질 등의 발광물질을 인식물질에 표지하여 인식물질과 분석물질과의 반응유무를 표지된 발광물질의 광학 신호를 감지하여 분석물질을 검출해내는 표지식 광 바이오센서 기술이 상용화되고 있다. 그러나 이러한 분석 방법은 민감도는 우수하지만 분석 시간이 매우 느리고, 고가의 분석 장비 및 복잡한 제조 공정 등의 단점들을 가지고 있다. 이러한 단점들을 극복하기 위하여 생화학 반응 유무를 표지물질 없이 광학적 방식으로 직접 측정할 수 있는 비표지식 광 바이오센서 기술이 최근 들어 많이 연구되고 있다. 본 논문에서는 광파장 이하의 주기를 가진 주기적 공진 격자 표면에서 일어나는 바이오 항원-항체 반응에 대한 공진 반사 파장을 측정하여 생체성분 내에 존재하는 바이오 항원을 고감도로 검출할 수 있는 비표지식 공진반사광 바이오센서 기술을 소개하고자 한다. 공진반사광 바이오센서를 이용하여 human serum내에 존재하는 심근경색 마커인 troponin I (cTnI), creatine kinase MB (CK-MB), myoglobin (MYO)을 0.1 ng/mL 이하의 농도까지 고감도로 측정할 수 있었다.

  • PDF

Pharmacogenomics in Cancer Research

  • Rha Sun-Young
    • Proceedings of the Korean Society for Bioinformatics Conference
    • /
    • 2006.02a
    • /
    • pp.91-96
    • /
    • 2006
  • 현대의학의 발전으로 많은 질병들의 치료율이 개선되고 있으나, 암은 여전히 낮은 치료율과 약제 내성 및 부작용으로 많은 환자들이 의학적 고통 뿐 아니라 정신적, 경제적 문제점들을 호소하고있다. 이와같은 문제점은 동일한 병리학적 특성을 가지는 종양이라도 사람마다 그 생물학적 특성이 다르며, 동일한 환자안에서도 종양의 시기에 따라 다양한 특성의 세포들이 공존하며 다양한 문제를 발생하는 tumor heterogeneity에서 기인하게된다. 다행히 최근의 분자생물학의 발전과 인간유전체연구들의 활성화로 이와같은 다양한 암의 특성과 환자들의 특성을 이해하는 연구 방법들의 개발로 환자의 특성에 맞는 항암제를 효율적으로 투여하는 맞춤치료를 향한 노력을 지속하고 있다. 이와같은 맞춤치료의 일환으로 약제의 환자에서의 반응과 부작용을 예측하고자 최신의 high-throughput 기법을 도입한 것이 Pharmacogenomics이다. 즉, 지금까지의 항암치료는 암의 종류에 따라 임상연구 결과에 근거한 항암제를 선택하고 있다. 그러나 앞서 설명한 것처럼 암의 특성과 환자 반응의 다양화로 실제 항암효과는 기대에 미치지 못하여 많은 수의 환자들이 치료에 내성을 보일 뿐 아니라 치명적인 부작용으로 새로운 문제에 대면하게 되었다. 따라서 각 항암제011 최대의 효과를 보이며 최소의 부작용을 나타내는 최선의 치료책을 선정하는 것이 중요한 과제이다. 이를 위해서 암환자의 치료 단계에서 정확한 진단 및 병기 설정, 생물학적 특성 이해 뿐 아니라, 치료 반응을 예측할 수 있는 생물학적 표지자를 찾고자 하는 노력의 결과로 현재 임상에 사용되는 몇 가지 종양표지자를 포함하여 다양한 유전자 칩들이 연구단계에 있다. 특히 다양한 생물학적 현상이 많은 유전자들의 변화에 의한다는 근거하여 약제의 효과와 부작용을 예측할 수 있는 표지자 발굴도 DNA chip 등의 high-throughput technology를 사용하여 그 특이도와 민감도가 향상된 표지자 발굴이 시도되고 있다. 아직은 시작단계이고 많은 검증이 필요하나 여러 가지 가능성의 증거들로 멀지않은 시기에 맞춤치료가 가능하리라 기대하며, 암 연구에 있어서 pharmacogenomics의 현황을 소개하고자 한다.

  • PDF