• Title/Summary/Keyword: 진단 영상

Search Result 3,016, Processing Time 0.041 seconds

A Study on The Consumer Expectation - Performance according to the Types of Internet Shopping Malls (인터넷 쇼핑몰 유형에 따른 소비자 기대-성과에 관한 연구)

  • Lee, In-Ku;Ryoo, Hak-Soo
    • Korean Business Review
    • /
    • v.17 no.2
    • /
    • pp.63-87
    • /
    • 2004
  • To create and maintain comparative supremacy as a strategic tool of business, many organizations have introduced informational technology and system. By using this system, Some companies got a beneficial value for achieving organizational goals but others could not obtain their effectiveness and efficiency. In particular, a lot of organizations that tried to make strategic supremacy with e-commercial trade are under hard condition because of poor profit. It implies that it is essential to identify and analyse the consumer who uses e-commercial trade. This paper, therefore, focusing on internet shopping malls between business and consumer as one of areas of e-commercial trades, shows the difference between consumer expectation and performance. The results of this study are as follows: First, as for the significant difference of influencing factors to consumer satisfactions according to the types of internet shopping malls, there is a meaningful difference in consumer anxiety and internet usefulness, but not in consumer service. Prior to verify the differences in detail on consumer's anxiety and internet usefulness, we examined that there is any difference between expectation and performance. T-test was used for the variants of consumer anxiety and internet usefulness, and its meaningful probability was 0.000, which means that both showed statistically significant difference. Based on the results, we also found that regardless of the types of internet shopping malls, consumer expectation was greater than performance. although the difference between expectation and performance was not equal according to the internet shopping malls. Second, a regression analysis was performed to understand the relation between consumer service, internet usefulness, consumer anxiety, and consumer satisfaction, it was found that consumer service, internet usefulness, consumer anxiety had significantly effected on consumer satisfaction. Third, To verify the relation between consumer satisfaction and repurchase-intentions, intentions to spread out, Pearson correlation analysis was used. it was found that consumer satisfaction had positive effect on both intentions. This study has some limitations because of the shorts of money and time. since the sample of this study was consumers who have ever bought one or more products via internet shopping mall, this sample was appropriate. but the major parts of sample were college students, and the sample size was so small. therefore this results should carefully be generalized. For further study, it is required to select more precise samples and to include more variables.

  • PDF

Bladder Volume Variations in Patients Receiving Conformal Radiotherapy to Prostate (전립선암 환자의 방사선 치료 시 방광 체적 변화)

  • Lee, Re-Na;Lee, Ji-Hye;Lee, Kyung-Ja;Ji, Young-Hoon
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.2
    • /
    • pp.61-65
    • /
    • 2008
  • Objective: To reduce urinary side effects in prostate cancer patients receiving radiation, patients were asked to drink certain amount of water to maintain bladder volume constant and the bladder volumes were measured weekly using ultrasound scanner. Materials and Methods: Twenty-six patients with prostate cancer who received radiation between December 2002 and August 2007 were enrolled in this study. Thirteen patients were enrolled in experimental group. These patients were asked to drink 450 cc of water, one hour prior to simulation, CT scan, and treatment. The other thirteen patients were given no information about bladder filing. Bladder, prostate, and rectum were contoured on CT and volumes were calculated. 3D conformal treatment planning was performed and effective volumes of bladder were calculated when a prescription dose of 70.2 Gy was delivered. For the patients in experimental group, bladder volumes were measured weekly using ultrasound scanner for 6-8 weeks and the bladder volume variations were analyzed. Results: Average bladder volumes and standard deviations obtained at CT scanning were $283.5{\pm}114.0\;cc$ (40%) and $181.2{\pm}120.1\;cc$ (66%) in experimental and control groups, respectively. Although it was not statistically significant, there was correlation between the bladder volumes measured from CT and ultrasound. The volumes measured using ultrasound scanner were 62% lower than the volumes using CT images on average. There was significant variations in volumes measured weekly for 6-8 weeks. It ranged between 33 - 75 %. Conclusion: Our results showed that it is possible to obtain larger bladder volume if they are asked to drink certain amount of water prior to CT scan. However, patients were unable to maintain constant bladder volumes over the 6-8 weeks of treatment period although they were asked to drink constant amount of water.

Causes of Under-staging in Patients with Gastric Cancer That was Proven to be Unresectable after a Laparotomy - Correlation with CT Findings (비절제 위암의 원인분석-전산화단층촬영(CT) 소견을 중심으로)

  • Yoon, Hyuk-Jin;Shin, Jung-Hye;Kim, Gab-Chul;Yu, Wan-Sik;Chung, Ho-Young
    • Journal of Gastric Cancer
    • /
    • v.6 no.4
    • /
    • pp.263-269
    • /
    • 2006
  • Purpose: The aim of this study was to investigate the causes of under-staging in patients with advanced gastric cancer that was proven to be unresectable after a laparotomy. Materials and Methods: We retrospectively analyzed 25 gastric cancer patients who had undergone a diagnostic laparotomy between 2001 and 2005. For the preoperative evaluation, spiral CT and multidetector-row CT were performed. We analyzed the clinicopathologic features of patients and compared the image findings and the results of surgery. The causes of under-staging were divided into 3 groups; patient factor, CT factor, and interpretation factor. Results: Grossly, there were 12 cases of Borrmann type-III tumors and 13 cases of Borrmann type-IV tumors. The most frequent histologic type was poorly differentiated adenocarcinomas (8 cases) and signet ring cell carcinomas (7 cases). There were 13 cases of adjacent organ invasion, and the pancreas was the most frequently invaded organ (9 cases). There were 17 cases of peritoneal metastasis, and 3 cases of distant lymph node metastasis. For the cause of under-staging, there were four cases of patient factor, 19 cases of interpretation factor, and 9 cases of CT factor. In three cases, the cause of under-staging could not be identified. Conclusion: CT interpretation factor was the most frequent cause of under-staging in the preoperative diagnosis with gastric cancer patients. Therefore, more cautious CT interpretation is necessary to avoid unnecessary laparotomies in gastric cancer patients.

  • PDF

Analyze for the Quality Control of General X-ray Systems in Capital region (수도권지역 일반촬영 장비의 정도관리 분석)

  • Kang, Byung-Sam;Lee, Kang-Min;Shim, Woo-Yong;Park, Soon-Chul;Choi, Hak-Dong;Cho, Yong-Kwon
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.93-102
    • /
    • 2012
  • Thanks to the rapid increase of the interest in the quality control of the General X-ray systems, this research proposes the direction of the quality control through comparing and inspecting the actual condition of the respective quality control in the Clinic, the educational institution and the hospital. The subjects of the investigation are diagnostic radiation equipment's in the clinic, the educational institution and the hospital around the capital. A test of kVp, mR/mAs out put test and reproducibility of the exposure dose, half value layer, an accordance between the light field and the beam alignment test, and lastly reproducibility of the exposure time. Then the mean difference of the percentage, the CV (Coefficient of Variation, CV) and the attenuated curve which are respectively resulted from the above tests are computed. After that we have evaluated the values according to the regulations on the Diagnostic Radiation Equipment Safety Administration regulations. In the case of the clinic and the educational institution, there were 22 general X-ray devices. And 18.2% of the kVp test, 13.6% of the reproducibility of exposure dose test, 9.1% of the mR/mAs out put test, and 13.6% of the HVL (Half Value Layer) test appeared to be improper. In the case of the hospital, however, there were 28 devices. And 7.1% of the reproducibility of exposure dose, 7.1% of the difference in the light field/ beam alignment, and 7.1% of the reproducibility of the exposure time appeared to be improper. According to the investigation, the hospital's quality control condition is better than the condition in the clinic and the educational institution. The quality control condition of the general X-ray devices in the clinic is unsatisfactory compared to the hospital. Thus, it is considered that realizing the importance of the quality control is necessary.

Effects of Gadolinium Contrast agent on Bone Mineral Density Measurement using Dual Energy X-ray Absorptiometry (가돌리늄조영제가 이중에너지 X-선 흡수법을 이용한 골밀도검사에 미치는 영향)

  • Lee, Keun-Ohk;Lee, Min-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.63-70
    • /
    • 2021
  • Radiographic contrast agents are used for diagnostic purposes and are one of the factors affecting measured values in bone density tests. They are absorbed into tissues and have an effect of increasing the measured values of bone density, so they are avoided as much as possible before performing a bone density test. MRI contrast agents, which have different physical properties and mechanisms of action than radiographic contrast agents, are based on gadolinium, a metal element. They have radiopacity characteristics, so MRI are generally performed prior to examination using radiation. The purpose of this study was to investigate the effects of MRI contrast agents on bone mineral density examination using dual energy X-ray absorption. Two types of gadolinium based MRI contrast agents were injected into an acrylic water tank for each volume, and the humanoid spine phantom was inserted and the BMD and T-score from (L1-L4) were analyzed by scanning a total of 30 times, 5 times for each injection type. The average value of the measured total (L1-L4) bone density for each of the two contrast agents was 0.952±0.052, 0.957±0.050, and 0.956±0.05g/㎠, respectively, for the Gadoterate Meglumine component 0mL, 7.5mL and 15mL, when the gadobutrol components were 0mL, 5mL, and 10mL, there was no statistically significant difference at all sites at 0.953±0.001, 0.954±0.001, and 0.945±0.001g/㎠, respectively(p>0.05). The average value of total T-score was -0.46±0.05, -0.4±0, -0.42±0.04 when the Gadoterate Meglumine component was 0mL, 7.5mL and 15mL, respectively. When the Gadobutrol ingredients were 0mL, 5mL and 10mL, there was no statistically significant difference in all areas, with -0.46±0.05, -0.46±0.05, and 0.5±0.00, respectively. In this experiment, the MRI contrast agent was found to have no effect on bone density tests, using the dual-energy X-ray absorption method. There is a limitation in that physical conditions such as kidney and health conditions etc. were not taken into consideration, so further clinical research is expected to be conducted in the future.

Discrepancy and Correlation in the renal length between Kidney CT and 99mTc-DMSA Renal scan (신장 CT 검사와 99mTc-DMSA Renal Scan 검사에서 측정한 신장 길이의 차이 및 상관분석)

  • Jung, Woo-Young;Shim, Dong-Oh;Lee, Dong-Hun;Choi, Jae-Min
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.1
    • /
    • pp.15-20
    • /
    • 2021
  • Purpose This article studies the relationship between the length of a kidney measured by two scanning methods: Kidney Computed Tomography (CT) and 99mTc-Dimercaptosuccinic acid (DMSA) renal scan. Kidney CT provides a better anatomic assessment, while 99mTc-DMSA renal scan is superior in the kidney function test. Materials and Methods From January to December of 2019, two hundred patients who had Kidney CT and Tc99m-DMSA renal scan were chosen for this study. SPSS17.0 was selected for statistical analysis. Results Due to the effect of the breathing and resolution of 99mTc-DMSA renal scan, it showed the kidney's relatively longer length than the length of Kidney CT. For the same kidney, the length comparison among different brands' Gamma cameras was negligible. The length difference within the same age group did not show a noticeable discrepancy. However, there was a length difference between the radio technologists. Kidney CT and 99mTc-DMSA renal scan indicated a strong positive correlation between the length of the left and right kidney. Conclusion It is necessary to establish a standardized measurement method for measuring kidney length using 99mTc-DMSA renal scan. The kidney's functional changes and length changes are indications of Kidney diseases. Especially, pediatric patients tend to use 99mTc-DMSA renal scan for assessing the kidney's shape and the function to avoid potential radiation exposure during the Kidney CT. Therefore, it is significant to provide not only the kidney's functional information but also an anatomic analysis, including the kidney's size, length, and location through the 99mTc-DMSA renal scan.

Arthroscopic Full-Thickness Rotator Cuff Repair in Elderly Patients (고령 환자의 관절경적 회전근 개 봉합술의 결과)

  • Cheon, Sang Jin;Lee, Dong Ho;Park, Yong Geon;Son, Seung Min
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.1
    • /
    • pp.38-45
    • /
    • 2020
  • Purpose: To examine the clinical and structural outcomes of an at least two-year follow-up of arthroscopic full-thickness rotator cuff repairs with a single-row or suture-bridge technique in patients more than 65 years of age. Materials and Methods: Patients diagnosed with a full-thickness rotator cuff tear who were more than 65 years of age, underwent arthroscopic rotator cuff repair after at least six months of conservative treatment, agreed to take a follow-up magnetic resonance imaging (MRI) six months postoperatively, and visited outpatient for at least two years were enrolled in this study. Clinical evaluations were done using The University of California Los Angeles score, Constant Shoulder Score, and visual analogue scale evaluated two years after the surgery. The structural integrity was analyzed using follow-up MRI. During surgery, a suture-bridge technique was used if the rotator cuff tendon could cover half of the footprint under constant tension. Otherwise, single-row repair was performed. Results: The samples were 158 cases, consisting of 93 single-repairs and 65 suture-bridge repairs. A preoperative comparison of the age distribution, fatty degeneration of supraspinatus and infraspinatus muscle, medial retraction of torn cuff tendon, and tear size between the two groups were not significant. The clinical scores were improved significantly in all cases. The distribution of the structural integrity by Sugaya classification were 49 cases in type 1 (31.0%), 62 cases in type 2 (39.2%), 30 cases in type 3 (19.0%), 11 cases in type 4 (7.0%), and six cases in type 5 (3.8%). The re-tear rate of the single-row group was 9.7% (nine out of 93 cases) and 12.3% (eight out of 65 cases) for the suture-bridge group. Conclusion: Satisfactory clinical and radiological outcomes were achieved after arthroscopic full-thickness rotator cuff repair in patients more than 65 years of age. Both single-row and suture-bridge techniques would be beneficial for the elderly.

A Case of Urologic Manifestation of IARS2-associated Leigh Syndrome (IARS2 유전자 연관 리 증후군(Leigh syndrome) 여아에서 방광기능장애 증례)

  • Hyunjoo Lee;Ji-Hoon Na;Young-Mock Lee
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.23 no.1
    • /
    • pp.25-30
    • /
    • 2023
  • Leigh syndrome is a rare progressive neurodegenerative mitochondrial disorder with clinical and genetic heterogeneity. Recently, balletic IARS2 variants have been identified in a number of patients presenting broad clinical phenotypes from Leigh and West syndrome to a rare syndrome CAGSSS characterized by cataracts, growth hormone deficiency, sensory neuropathy, sensorineural hearing loss, and skeletal dysplasia syndrome (OMIM#616007). We describe a child with Korean Leigh syndrome with urologic manifestations resulting from a compound heterozygote mutation in IARS2. A 5-year-old girl visited the emergency room with a complaint of abdominal pain accompanied by abdominal distension. Abdominal-pelvic CT showed a markedly distended urinary bladder without definite obstructive lesions. She was diagnosed with neurogenic bladder dysfunction based on a urodynamic study. She had global delayed development due to neurologic regression after 6 months of age and a history of bilateral cataract surgery at the age of 2 years. Her brain magnetic resonance imaging showed symmetrically increased signal intensities in the bilateral putamen and caudate nuclei with diffuse cerebral atrophy. No gene variants were identified through whole-mitochondrial genome analysis. Whole exome sequencing was performed for diagnosis, and compound heterozygous pathogenic variants were identified in IARS2: c.2446C>T (p. Arg816Ter) and c.2450G>A (p. Arg817His). To the best of our knowledge, this is the first case report of bladder dysfunction manifestation in a patient with IARS2-related Leigh syndrome. Thus, it broadens the clinical and genetic spectrum of IARS2-associated diseases.

  • PDF

Significance Evaluation of Lung Volume and Pulmonary Dysfunction (폐용적과 폐기능 환기장애에 대한 유의성 평가)

  • Ji-Yul Kim;Soo-Young Ye
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.767-773
    • /
    • 2023
  • To In this study, we sought to evaluate related factors affecting lung volume and their significance in pulmonary function and ventilation disorders. As experimental subjects, 206 normal adult men and women who underwent a low-dose chest CT scan and a spirometry test were selected at the same time. The experimental method was to measure lung volume using lung CT images obtained through a low-dose chest CT scan using deep learning-based AVIEW. Measurements were made using the LCS automatic diagnosis program. In addition, the results of measuring lung function were obtained using a spirometer, and gender and BMI were selected as related factors that affect lung volume, and significance was evaluated through an independent sample T-test with lung volume. As a result of the experiment, it was confirmed that in evaluating lung volume according to gender, all lung volumes of men were larger than all lung volumes of women. he result of an independent samples T-test using the respective average values for gender and lung volume showed that all lung volumes were larger in men than in women, which was significant (p<0.001). And in the evaluation of lung volume according to BMI index, it was confirmed that all lung volumes of adults with a BMI index of 24 or higher were larger than all lung volumes of adults with a BMI index of less than 24. However, the independent samples T-test using the respective average values for BMI index and lung volume did not show a significant result that all lung volumes were larger in BMI index 24 or higher than in BMI index less than 24 (p<0.055). In the evaluation of lung volume according to the presence or absence of pulmonary ventilation impairment, it was confirmed that all lung volumes of adults with normal pulmonary function ventilation were larger than all lung volumes of adults with pulmonary ventilation impairment. And as a result of the independent sample T-test using the respective average values for the presence or absence of pulmonary ventilation disorder and lung volume, the result was significant that all lung volumes were larger in adults with normal pulmonary function ventilation than in adults with pulmonary function ventilation disorder (p <0.001). Lung volume and spirometry test results are the most important indicators in evaluating lung health, and using these two indicators together to evaluate lung function is the most accurate evaluation method. Therefore, it is expected that this study will be used as basic data by presenting the average lung volume for adults with normal ventilation and adults with impaired lung function and ventilation in similar future studies on lung volume and vital capacity testing.

One-stop Evaluation Protocol of Ischemic Heart Disease: Myocardial Fusion PET Study (허혈성 심장 질환의 One-stop Evaluation Protocol: Myocardial Fusion PET Study)

  • Kim, Kyong-Mok;Lee, Byung-Wook;Lee, Dong-Wook;Kim, Jeong-Su;Jang, Yeong-Do;Bang, Chan-Seok;Baek, Jong-Hun;Lee, In-Su
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.33-37
    • /
    • 2010
  • Purpose: In the early stage of using PET/CT, it was used to damper revision but recently shows that CT with MDCT is commonly used and works well for an anatomical diagnosis. This hospital makes the accuracy and convenience more higher in the diagnosis and evaluate of coronary heart disease through concurrently running myocardial perfusion SPECT examination, myocardial PET examination with FDG, and CT coronary artery CT angiography(coronary CTA) used PET/CT with 64-slice. This report shows protocol and image based on results from about 400 coronary heart disease examinations since having 64 channels PET/CT in July 2007. Materials and Methods: An Equipment for this examination is 64-slice CT and Discovery VCT (DVCT) that is consisted of PET with BGO ($Bi_4Ge_3O_{12}$) scintillation crystal by GE health care. First myocardial perfusion SPECT with pharmacologic stress test to reduce waiting time of a patient and get a quick diagnosis and evaluation, and right after it, myocardial FDG PET examination and coronary CTA run without a break. One-stop evaluation protocol of ischemic heart disease is as follows. 1)Myocardial perfusion SPECT with pharmacologic stress: A patient is injected with $^{99m}Tc$-MIBI 10 mCi and does not have any fatty food for myocardial PET examination and drink natural water with ursodeoxcholic acid 100 mg and we get SPECT image in an hour. 2)Myocardial FDG PET: To reduce blood fatty content and to increase uptake of FDG, we used creative oral glucose load using insulin and Acipimox to according to blood acid content. A patient is injected with $^{18}F$-FDG 5 mCi for reduction of his radiation exposure and we get a gated image an hour later and get delay image when we need. 3) Coronary CTA: The most important point is to control heart rate and to get cooperation of patient's breath. In order to reduce a heart rate of him or her below 65 beats, let him or her take beta blocker 50 mg ~ 200 mg after a consultation with a doctor about it and have breath-practices then have the examination. Right before the examination, we spray isosorbide dinitrate 3 to 5 times to lower tension of bessel wall and to extension a blood wall of a patient. It makes to get better the shape of an anatomy. At filming, a patient is injected CT contrast with high pressure and have enough practices before the examination in order to have no problem. For reduction of his radiation exposure, we have to do ECG-triggered X-ray tube modulation exposure. Results: We evaluate coronary artery stenosis through coronary CTA and study correlation (culprit vessel check) of a decline between stenosis and perfusion from the myocardial perfusion SPECT with pharmacologic stress, coronary CTA, and can check viability of infarction or hibernating myocardium by FDG PET. Conclusion: The examination makes us to set up a direction of remedy (drug treatment, PCI, CABG) because we can estimate of effect from remedy, lesion site and severity. In addition, we have an advantage that it takes just 3 hours and one-stop in that all of process of examinations run in succession and at the same time. Therefore it shows that the method is useful in one stop evaluation of ischemic heart disease.

  • PDF