• Title/Summary/Keyword: 진단장비

Search Result 743, Processing Time 0.033 seconds

Definition and Extraction of Causal Relations for Question-Answering on Fault-Diagnosis of Electronic Devices (전자장비 고장진단 질의응답을 위한 인과관계 정의 및 추출)

  • Lee, Sheen-Mok;Shin, Ji-Ae
    • Journal of KIISE:Software and Applications
    • /
    • v.35 no.5
    • /
    • pp.335-346
    • /
    • 2008
  • Causal relations in ontology should be defined based on the inference types necessary to solve problems specific to application as well as domain. In this paper, we present a model to define and extract causal relations for application ontology for Question-Answering (QA) on fault-diagnosis of electronic devices. Causal categories are defined by analyzing generic patterns of QA application; the relations between concepts in the corpus belonging to the causal categories are defined as causal relations. Instances of casual relations are extracted using lexical patterns in the concept definitions of domain, and extended incrementally with information from thesaurus. On the evaluation by domain specialists, our model shows precision of 92.3% in classification of relations and precision of 80.7% in identifying causal relations at the extraction phase.

3T MR Imaging에 적합한 RF Surface Coil의 개발 : 피부 미세구조에 대한 예비 연구

  • 윤성익;이정우;최보영;이형구;서태석
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.48-48
    • /
    • 2003
  • Abstract: 현대 질병의 최종진단은 세포수준의 해부형태학적 연구가 일반적이며 광학현미경이나 전자현미경을 이용한 병리조직학적 소견을 바탕으로 진단되어지고 있다. 이러한 진단에는 In vivo 검사가 거의 불가능하여 주로 생검을 통한 연구만 수행되고 있어 진단함에 있어 단계적인 불편이 초래될 뿐만 아니라 악성 종양의 전이를 유발시킬 수 있고 또한 생리 및 생화학적 분석이 어렵다. 이러한 문제점을 해결하기 위해 고분해능의 RF Surface Coil을 개발하여 In vivo 및 비침습적인 방법인 MR Technology를 이용하고자 한다. Introduction: 피부조직과 같은 미세 인체구조 연구를 위해 고해상도 3T MRI 시스템에 적합한 고분해능의 RF surface coil을 개발하고 있다. In vivo 연구를 위한 여러 parameter를 최적화하여 기능영상에도 부합된다. 비침습적인 In vivo 검사에 의한 세포수준의 극 미세구조의 연구가 가능해짐으로써 과거 시행하던 침습적인 생검없이 각종질환의 진단적 접근이 병리학적 수준으로 향상되어 질병의 정확한 진단이 가능해지게 될 것이다. Method: 고분해능의 RF Surface Coil을 제작하여 3T MR 장비에서 피부 미세구조연구에 보다 적합하도록 In vivo 및 In vitro 실험을 수행하였다. In vitro 실험은 In vivo 연구를 위한 여러 parameter들을 최적화하기 위한 기초 실험을 하였고 다양한 팬톰들을 이용하여 Tl 강조영상, T2 강조영상을 획득하였으며, SNR을 높이기 위한 개선에 대한 연구를 수행하였다. In vivo 실험은 정상피부에서 다양한 부위에 대한 피부영상의 예비 연구를 수행하였다. Result and Discussion: 비침습적인 In vivo 검사에 의한 세포수준의 극 미세구조의 연구가 가능해짐으로써 과거 시행하던 침습적인 생검없이 각종질환의 진단적 접근이 병리학적 수준에서 가능해짐으로써 질병의 정확한 진단이 가능해지게 될 것이다. Acknowledgement: 본 연구는 2002 년도 한국과학재단 목적기초연구사업 (과제번호 : R0l-2002-000-00294-0 (2002)) 지원아래 수행되었다.

  • PDF

Evaluation of IH-1000 for Automated ABO-Rh Typing and Irregular Antibody Screening (ABO 및 RhD 혈액형 검사와 비예기항체 선별검사를 위한 자동화장비 IH-1000의 평가)

  • Park, Youngchun;Lim, Jinsook;Ko, Younghuyn;Kwon, Kyechul;Koo, Sunhoe;Kim, Jimyung
    • The Korean Journal of Blood Transfusion
    • /
    • v.23 no.2
    • /
    • pp.127-135
    • /
    • 2012
  • Background: Despite modern advances in laboratory automated medicine, work-process in the blood bank is still handled manually. Several automated immunohematological instruments have been developed and are available in the market. The IH-1000 (Bio-Rad Laboratories, Hercules, CA, USA), a fully automated instrument for immunohematology, was recently introduced. In this study, we evaluated the performance of the IH-1000 for ABO/Rh typing and irregular antibody screening. Methods: In October 2011, a total of 373 blood samples for ABO/Rh typing and 303 cases for unexpected antibody screening were collected. The IH-1000 was compared to the manual tube and slide methods for ABO/Rh typing and to the microcolumn agglutination method (DiaMed-ID system) for antibody screening. Results: For ABO/Rh typing, concordance rate was 100%. For unexpected antibody screening, positive results for both column agglutination and IH-1000 were observed in 10 cases (four cases of anti-E and c, three of anti-E, one of anti-D, one of anti-M, and one of anti-Xg) and negative results for both were observed in 289 cases. The concordance rate between IH-1000 and column agglutination was 98.7%. Sensitivity and specificity were 90.9% and 99.3%, respectively. Conclusion: The automated IH-1000 showed good correlation with the manual tube and slide methods and the microcolumn agglutination method for ABO-RhD typing and irregular antibody screening. The IH-1000 can be used for routine pre-transfusion testing in the blood bank.

Evaluation to X-ray Tube Variable Beam Limiting Device Ability Test, Collimation and Beam Alignment Test of Diagnostic X-ray Unit (진단용 X선발생장치의 X선관 가변조리개 성능검사와 조사야일치검사 및 중심선속 일치검사에 대한 평가)

  • Im, In-Chul;Lee, Sang-Hun
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.3
    • /
    • pp.250-255
    • /
    • 2009
  • This study performed and evaluated the performance test in 40 general X-ray units among diagnostic X-ray units, which were being used in hospitals of gyeongsangnam-do gimhae-si through X-ray tube variable limiting device ability test, the light field and X-ray field alignment test and collimation and beam alignment test of diagnostic X-ray unit. The results are as followings: In a variable beam limiting device ability test, the result of maximum X-ray field test showed that 4(10%) of were incongruent while the result of minimum X-ray field test represented that 5(12.5%) of were incongruent. The result of the light field and X-ray field alignment test showed 23(57.5%) of were within 2% of maximum permissible level and the other 17(42.5%) units were misalignment. The result of beam alignment test represented that 11(27.5%) coincided and another 11(27.5%) within $0.5^{\circ}$ respectively, 10(25%) were $0.6^{\circ}-1.5^{\circ}$ intervals, 7(17.5%) were $1.6^{\circ}-3^{\circ}$ and 1(2.5%) were more than $3^{\circ}$.

Study on Infrared Thermography (적외석 체열촬영에 관한 고찰)

  • Kim, Ho-Bong
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.1 no.1
    • /
    • pp.9-14
    • /
    • 1995
  • Thermography is a diagnostic procedures that measures infrared energy emitted by the skin. Thermography detects body temperature change which are controlled by the autonomic nervous system. It does show the thermal dysfunction that correlates closely with pain syndromes as well as normalization when the healing process takes place. Experienced clinical interpretation of the thermal pattern is necessary to diagnose and establish causation. Thermography is useful in the diagnosis of painful conditions such as herniated disc diseases, myofascial syndrome, myositis, musculoligamentous injury, reflex sympathetic dystrophy, athretic injuries, vascular diseases, arthritis, inflammation and breast tumors.

  • PDF

Prediction of Cardiovascular Diseases using Wireless Transmission of Blood Pressure Data (혈압데이터 무선전송에 의한 심혈관질환의 예측시스템 구축)

  • 김태운;고창성;송종관;김법영
    • Proceedings of the Korea Inteligent Information System Society Conference
    • /
    • 2000.04a
    • /
    • pp.243-249
    • /
    • 2000
  • 본 연구의 목적은 휴대폰이나 무선호출기가 가진 양방향 데이터 전송기술을 활용하여 혈압자료를 주기적 혹은 수시로 송신하고 개인별로 축적된 건강관련데이터를 이용하여 혈압과 관련된 심혈관 질환을 예측하는 시스템을 개발하고자 한다. 본 시스템은 크게 5가지 모듈로 구성되어 있다. 첫째는 가정용 혈압측정기에 무선 데이터 전송 기능이 부가된 혈압측정 및 전송장비이다. 둘째는 무선데이터 송수신을 위한 데이터 전송과 관련된 시스템을 구축하는 부분이다. 셋째는 수신된 개인별 혈압 데이트를 DB화하고 이를 자동으로 검사하여 혈압 이상변동 여부를 수시로 확인하고, 필요시 본인에게 경고 메시지를 보내어서 담당의사와 상의하거나 병원에 가서 정밀진단을 받도록 사전에 건강 이상상태를 경고해 주는 조기경보시스템이다. 넷째는 의사의 전문지식과 개인별 혈압자료를 기초로 하여 인터넷 상에서 스스로 심혈관 관련 질병을 진단해 볼 수 있는 인터넷 기반 심혈관 질병 진단 시스템의 구축이다. 다섯 번째로는 이러한 모든 기능이 복합된 전체 시스템을 통합하고 각 부분을 연결하는 시스템 인터페이스 및 사용자가 아주 쉽게 사용할 수 있도록 하는 사용자 인터페이스 부분이다. 본 논문에서는 이를 위한 전체 시스템의 프레임웍을 제시하고 혈압과 의사의 전문지식에 기초한 심혈관 질병 진단 전문가 시스템에 대하여 구축하고자 한다.

  • PDF

Study on Medical Dicom based XRay Image improvement program using image processing (이미지 프로세싱을 이용한 의료용 Dicom기반의 XRay 영상 개선 프로그램 개발에 관한 연구)

  • Lee, So-Haeng
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.1
    • /
    • pp.1153-1156
    • /
    • 2005
  • PACS system developments for improve of diagnosis efficiency for hospital duty efficiency and patients through various medical image diagnosis device. PACS system studies for nonfilm hospital, but still, image filtering technology Present high accuracy take a photograph image be not enough. On study image processing part is very importance. The fittest of image processing in order to using simple and essential filter try to improvrnent. The future, diagnosis of patients decide accuracy, low cost based Digital XRay system will be using.

  • PDF

Development of medical image quantification software in the abdominal diseases (복부질환 의료영상 분석 소프트웨어 개발)

  • Kim, Ji-Eon;Kim, Seung-Jin;No, Si-Hyeong;Jun, Hong-Yong;Lee, Chung Sub;Ryu, Jong-Hyun;Kim, Tae-Hoon;Jeong, Chang-Won
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2019.05a
    • /
    • pp.348-349
    • /
    • 2019
  • 의료영상은 진단을 목적으로 환자의 질환 부위별로 정밀하게 촬영하여 수집된 영상이다. 수집된 의료영상을 판독하여 진단하기 어려운 경우에는 조직검사를 통해 확진검사를 실시한다. 하지만 조직검사의 경우 환자에게 신체적, 경제적 부담을 줄 수 있다. 따라서 의료영상을 기반으로 정밀 진단하는데 도움을 줄 수 있는 정량분석 소프트웨어 개발이 중요하다. 현재 복부 간 질환의 경우 MELD(Model For End-Stage Liver Disease) 점수를 이용하여 간 질환의 중증도나 예후를 예측하는데 이용되고 있다. 하지만 MELD점수 산출에 있어서 의료영상 정보를 사용하지 않았기 때문에 질환 여부를 가늠하는데 에만 이용될 뿐 병변부위의 위치를 확인하는데 에는 어려움이 있다. 그러므로 본 논문은 다양한 의료영상장비에서 획득한 복부영상을 이용하여 복부질환의 중증도를 예측 및 분석함으로서 실제 임상진단에 도움을 줄 수 있는 시스템을 제안하고자 한다.

Image Quality Evaluation according to the Application of Air Mattress on Computed Tomography Equipment Table (전산화단층촬영장비 테이블의 에어 매트리스 적용에 따른 화질평가)

  • Jeon, Sang-Won;Pak, Jae-Yun;Suh, Tae-Suk
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.6
    • /
    • pp.819-825
    • /
    • 2020
  • The purpose of this study was to evaluate the usefulness of the developed air mattress for reducing the deterioration of image quality due to the scattered radiation generated on the computed tomography equipment table. 5 cm and 10 cm thick air mattresses were developed and the image quality was measured by scanning the AAPM phantom according to thickness and thickness. Statistical significance was confirmed by One Way Analysis of Variance(ANOVA) Compared with the AAPM phantom scanned in the standard method, the image with the air mattress did not show any difference, but when the air mattress was not applied, the CT number and uniformity were low and the noise was high, and the spatial resolution Respectively. The developed air mattress has no harmful effect on the diagnostic image, it is very effective in improving the image quality and can increase the CT image quality by simply applying Air Mattress to existing equipment without using the technology applied to the latest and high-cost equipment.

핵의학 DICOM 영상 Data 분석

  • Kim, Sae-Rom;Jeong, Hae-Jo;Seong, Min-Mo;Choe, Seung-Uk;Jang, Bong-Mun;Yang, Geon-Ho;Kim, Hui-Jung
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.108-112
    • /
    • 2004
  • 현재 많은 병원의 핵의학과에서 핵의학 장비를 이용하여 많은 수의 핵의학영상을 생성하고 있다. 생성된 핵의학영상은 환자의 질병을 진단 또는 치료하기 위해 기능적 정보를 많이 포함하고 있다. 하지만 이렇게 중요한 기능적 정보가 현재의 PACS 에서는 그 중요한 기능적 정보를 모두 표현하지 못 하는 문제점이 있다. DICOM 에서는 핵의학 영상 및 데이터에 대하여 표준을 정해놓고 그 표준을 따르도록 규정하고 있다. 이러한 DICOM 3.0 표준에서 핵의학 영상 및 데이터에 대하여 표준을 정해놓은 일은 비교적 최근의 일이어서 많은 수의 핵의학 영상 장비나 PACS에서는 핵의학영상에 대한 특징이 반영되지 않고 있는 실정이다. 이에 핵의학 영상의 호환성을 향상과 PACS와 핵의학 장비간의 호환성을 향상시키기 위하여 DICOM 3.0 Part 3에 정의된 IOD 중 꼭 필요하다고 생각되는 최소한의 Tag들을 선별하여 Guideline을 작성하여 DICOM 영상을 Guideline의 내용을 토대로 분석하였고 핵의학 영상이 PACS에서 제대로 활용되지 못 하는 원인을 분석 하였다.

  • PDF