• Title/Summary/Keyword: 진단용방사선

Search Result 279, Processing Time 0.029 seconds

Comparison of the Legislation Applicable to Compare the use of Diagnostic Radiation Devices (진단용 방사선발생장치 이용에 적용되는 법제의 비교)

  • Ko, Jong-Kyung;Jeon, Yeo-Ryeong;Han, Eun-Ok;Cho, Pyong-Kon;Kim, Yong-Min
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.277-286
    • /
    • 2015
  • Diagnostic radiation devices that is used in the country has reached to 78,000 units. When used for human subjects diagnostic purposes, it is subject to Medical Service Act, when used in diagnostic purposes in animal subjects, the subject to Veterinarians Act. When used for other purposes are subject to the Nuclear Safety Act. Even the same radiation devices varies the legislation that is applied depending on the intended use and object. Diversified been p rovisions a re necessary compared to t he analysis o f l egal content in o rder t o prevent confusion of the legislation is a matter to be applied. It is a qualitative study that Nuclear Safety Act, Medical Service Act and Veterinarians Act administrative procedures for the introduction of the applied diagnostic radiation devices, safety inspection, human resources management, area management and the content related to administrative punishment. The Nuclear Safety Act sub-provisions, the introduction of diagnostic radiation generating devices, there are many complex and complete requirements administrative procedures on the concept of a permit. Inspection of safety associated with the use, would be subject to periodic inspection auditing characteristics over the entire field of radiation safety management. It must receive court regular education for the safety administrator and workers. Unlike the reference of the radiation dose rate to specify the radiation controlled area there is a measurement obligation of radiation dose rate. Unlike the reference of the radiation dose rate to specify the radiation controlled area there is a measurement obligation of radiation dose rate. Quantitative difference of administrative punishment that is imposed when legislation violation has reached up to 10 times, over the entire field, the largest burden of radiation safety management at the time of application of the Nuclear Safety Act sub provisions. And it is applied differently depending on the purpose and the imaging target using the same diagnostic radiation devices. Depending on the use mainly under the current legal system, radiation can be lacking in fairness of the contents of the legislation for safety management, there is a risk of confusion. Alternatives such as centralized and standardization of legislation by diagnostic radiation devices use is expected to be necessary.

The Recent Trend of the National and International Standard of Manufacturing Quality Control for Diagnostic X-ray Equipment (진단용엑스선장치 제조품질관리에 관한 국내.외 규격의 동향)

  • Choi, In-Seok;Kim, Jung-Min;Jeong, Hoi-Woun;Min, Jung-Whan;Lee, In-Su
    • Journal of radiological science and technology
    • /
    • v.32 no.1
    • /
    • pp.1-15
    • /
    • 2009
  • Newly published IEC 60601-1-3 ; 2008 2nd Edition has two important meanings. First, Radiation Quality and Dose should make sure for safety of patient and staff in manufacturing diagnostic X-ray equipment. Second, it should be minimized of Leakage Radiation, Residual Radiation, and Stray Radiation. The requirement to make enactment or revision of national standard for diagnostic X-ray Equipment is as follows : 1. It should be adjusted the new standard to the recent IEC Publication under the consideration of the Korea medical circumstances. 2. For focus to the Radiation Safety, IEC 60601-1-3 (General requirements for radiation protection in diagnostic X-ray equipment) could be applied to the new regulation. It should be compact sentence. 3. A sudden Notification change should not be desired. It needs a enough time to make easy the circumstances.

  • PDF

Perceptions of Patients and Radiologists on Exposure to Diagnostic Radiation (진단용 방사선 피폭에 관한 환자 및 종사자간 인식도 비교)

  • Kim, Gab-Jung;Hong, Jee-Young;Lee, Moo-Sik;Na, Baeg-Ju;Lee, Jin-Yong;Lee, Boo-Woo
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.05b
    • /
    • pp.1072-1075
    • /
    • 2011
  • 이 연구는 진단용 방사선피폭에 대한 환자 및 종사자의 방사선 인식도, 방사선 지식정도, 방사선 피폭의 유해성, 진단방사선의 필요성, 방사선의 피폭방지, 정보파악의 유무 및 파악경로, 방사선 검사 시 심리적 상태에 영향을 미치는 요인을 살펴보고자 하는 연구이다. 2010년 10월 25일부터 11월 10일까지 일개 광역시 소재하는 종합병원 및 의원에 근무하는 방사선사와 2주내에 진단 방사선을 이용한 해당 의료기관에 내원한 환자를 대상으로 총 347부의 유효설문지를 사용 하였다. 방사선에 대한 인식도에 영향을 미치는 요인으로는 환자의 경우, 직업, 2년내 건강검진 경험, 방사선 피폭에 대한 설명을 들은 경험으로 나타났고, 근무자의 경우, 2년내 교육이수 경험으로 나타났다. 방사선에 대한 지식정도에 영향을 미치는 요인으로는 환자의 경우, 2년내 건강검진 경험으로 나타났고, 근무자의 경우, 연령, 근무기관으로 나타났다. 방사선의 유해성에 영향을 미치는 요인으로는 환자의 경우, 성별, 2년내 건강검진 경험, 정보매체로 나타났고, 근무자의 경우, 근무기관으로 나타났다. 방사선의 필요성에 영향을 미치는 요인으로는 환자의 경우, 월소득, 거주지로 나타났고, 근무자의 경우, 결혼상태, 피폭선량계 착용여부, 환자에게 피폭에 대한 설명을 하는 것으로 나타났다. 방사선 피폭방지에 영향을 미치는 요인으로는 환자의 경우, 직업, 월소득, 2년 내 건강검진 경험으로 나타났고, 근무자의 경우 환자에게 피폭에 대한 설명을 하는 것으로 나타났다. 방사선검사의 심리적 상태에 영향을 미치는 요인으로는 환자의 경우, 방사선에 대한 피폭설명을 들은 경험, 직업으로 나타났고, 근무자의 경우, 연령, 경력, 2년내 교육이수 경험으로 나타났다. 그러므로 방사선 종사자들도 방사선의 위해성에 대한 올바른 인식을 하게 하여 방사선 방어를 적극적으로 할 수 있는 행동을 유도하기 위해서는 이용 방사선의 특성에 맞는 방사선 안전 관리 교육 프로그램의 개발과 방사선 종사자 스스로 방사선에 대한 안전성 확보를 위하여 노력해야 할 것이다.

  • PDF

A Base Study on the Constancy Quality Control Test and Clause of Diagnosis Radiation Equipment (진단용 방사선 발생장치의 수시 정도관리 항목 및 기준에 관한 기초 연구)

  • Heo, Yeji;Kim, Kyotae;Noh, Sicheul;Nam, Sanghee;Park, Jikoon
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.3
    • /
    • pp.105-110
    • /
    • 2014
  • Diagnostic radiation equipment diagnosis and treatment of disease of recent plays a central role, but this is based on the assumption of an appropriate balance of benefits and risks of diagnostic. If balance is not maintained has the potential to give an adverse effect on the health of the public. In the case of an overseas, the importance of (QA) quality assurance of medical equipment is growing, but evaluation criteria of quality assurance has not been clearly presented in domestic. Therefore, the modernization of medical equipment from the point at which the degree of cycle-by-cycle management system of foreign national to be suitable for diagnostic radiation generator entry and quality control standards by introducing a tailoring is necessary. In this study the most frequently used diagnostic radiation generator X-ray imaging apparatus of the general three-year periodic inspections at any time between the periodic inspection items and quality control methods and standards for the establishment of the United States, Canada and abroad, and international electronic literature search Technical Committee (International Electro-technical Commission, IEC) were compared with the provisions of item. Based on the national quality control items when opening frequent inspection items and standards presented as a basis for setting up study.