• Title/Summary/Keyword: 진단용방사선발생장치

Search Result 63, Processing Time 0.027 seconds

Evaluation and Experimental Production of Single-Phase Full-wave Rectification Type for X-ray Equipment of High Precision (고정밀도의 단상전파정류형 X선 장치의 제작 및 평가)

  • Han, Dong-Kyoon;Jung, Jae-Eun;Choi, Jun-Gu;Seoun, Youl-Hun;Ko, Shin-Gwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.1
    • /
    • pp.413-419
    • /
    • 2011
  • Diagnosis X-ray equipment localized at 1950's but it is developed suddenly at 1960's with demand together. Manufacture of Diagnostic X-ray equipment is controled by the KS regulation and the Ministry of Health and Welfare because of hazardous element etc. exposure by radiation. Most of diagnostic X-ray equipment ware single phase and three phase full-wave rectification but from 1980's it transforms it was exchanged in inverter type X-ray equipment. Inverter type X-ray equipment produces approximately 50~80% more average photon intensity then single phase full-wave rectification and the accuracy is high. But from a clinic it dose not use because expensive therefor the efficiency improvement of single phase full-wave rectification is necessary. We produced single phase full-wave rectification X-ray equipment control unit, high tension transformer, filament heating transformer, rectification circuit, high tension cable and others and evaluated efficiency, in result which is excellent compare with Rule of Safety Management and KS regulation.

A Performance Evaluation of Diagnostic X-ray Unit Depends on the Hospitals Size (병원 규모별 진단용 X선 발생장치의 성능 평가)

  • Park, Ju-Hun;Im, In-Chul;Dong, Kyung-Rae;Kang, Se-Sik
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.1
    • /
    • pp.31-36
    • /
    • 2009
  • The purpose of this study is to measure the tube voltage, the tube current/volume, exposure time and exposure dose of diagnostic X-ray unit in each doctor offices, hospitals and general hospitals for evaluating the performance of such device, to learn the method and technology of its measurement and to suggest its importance. Research subjects were total 30 X-ray units and divided into groups of 10 X-ray units each. The tube voltage, the tube current/volume, exposure time and exposure dose were measured using percentage average error, and then reproducibility of exposure dose was measured through calculating coefficient of variation. The results are like followings; The tube voltage correctness examination showed that incongruent devices among total 30 X-ray units were 5 devices (16.7%). The tube current correctness examination showed that incongruent X-ray units were 3 devices (10.0%). The tube current volume correctness examination showed that incongruent X-ray units were 4 devices (13.3%). Finally, according to exposure time correctness examination, incongruent X-ray units were 5 devices (16.7%) and according to reproducibility examination of exposure dose, incongruent X-ray units were 7 devices (23.3%). Above results showed serious problem in performance management based on management regulation of diagnostic X-ray unit; it means that regular checkout and safety management are required, and as doing so, patients will be able to receive good quality of medical service by the reduction of radiation exposure time, image quality administration, unnecessary retake and etc. Therefore, this study suggests that the performance of diagnostic X-ray units should be checked regularly.

Usability Evaluation of Foot Pedal Switch in X-ray Radiography System (진단용 엑스선 촬영장치에서 발판 스위치의 유용성 평가)

  • Kwon, Hyeokjin;Jung, Hongmoon;Jung, Jaeeun;Jung, Kyunghwan;Won, Doyeon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.651-658
    • /
    • 2018
  • A foot pedal switch in the diagnosis x-ray radiography system has been researched to improve radiologic technologist works and patient satisfaction. The switch has been installed in the diagnosis x-ray radiography system used in domestic clinics. Quantitative evaluation has been conducted by measuring the exposure dose reproducibility test, tube voltage, mAs, and percentage average error. Qualitative evaluation has been conducted by analysis of the radiologic technologists questionnaire. In the quantitative evaluation for the use of the foot pedal switch, the coefficient of variation was less than 0.05 in the exposure dose reproducibility test. In the mAs test, percentage average error of ${\pm}20%$ was measured. There was no problem raised since it meets the all inspection standards of the diagnosis x-ray generator. In the qualitative evaluation, most of the opinions are that it has a clinical value for the foot pedal switch in the diagnosis x-ray radiography system. Therefore, developing the foot pedal switch for the diagnosis x-ray radiography system can improve effectively the rapidity and accuracy of the radiologic technologist work. In addition, it is effective in decreasing the x-ray exposure of patients and increasing satisfaction for the medical service due to reduction of retaking x-ray.

The present condition and improvement program of the diagnostic safety management (진단용방사선발생장치의 안전관리 문제점과 개선방안)

  • Seo Jae Lyong
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.27 no.2
    • /
    • pp.260-268
    • /
    • 2001
  • Ⅰ. Introduction : 'The regulation for the safety management of diagnostic radiation apparatus' legislated and it has been managed systematially. So that, it enables a national health to be protected from harmful radiation. But, managers and administers of

  • PDF

Improvement Way for Mobile X-ray Examinations by Rule Revision about Safety Management of Diagnosis Radiation Occurrence System (진단용방사선발생장치의 안전관리에 관한 규칙 개정에 따른 이동형 방사선검사의 개선방안)

  • Choi, Jun-Gu;Kim, Gyeong-Su;Kim, Byeong-Gi;Ahn, Nam-Jun;Kim, Hyeong-Sun;Kim, Sang-Geon;Lim, Si-Eun
    • Journal of radiological science and technology
    • /
    • v.30 no.1
    • /
    • pp.53-59
    • /
    • 2007
  • A safety management rule of the diagnosis radiation system which opened a court 2006 February 10th was promulgated for safety of the radiation worker, patients and patients' family members. The purpose of this study is to minimize injury by radiation that can happen to patients and people around a sick ward when managing mobile X-ray system. This study analyzed sickroom environment of mobile X-ray examination and the statistical data of the Konkuk medical Information System(KIS) and the Picture Archiving Communication System(PACS). This study also investigated patient conditions, infection, relation information and related data, when the sickroom mobile X-ray examination is used. Through data analysis, many problems were expected such as restriction of space side, manpower and expense of business side, satisfaction degree decline of patient and protector of operation side. Therefore, we tried to restrict examination of multi bed sickroom, and to use treatment room in each ward to solve problem mentioned. As a result, the whole sickroom mobile X-ray examination rate decreased to near 50%, and mobile X-ray examination rate for inpatients decreased to more than 85%. This study shows that several attempts we did should be helpful for manpower, patients satisfaction and expenses. Also, they should protect patients in sickroom from unnecessary radiation exposure and could minimize inconvenience of patients and their family members from x-ray examination.

  • PDF

홍보자료 I: 2011년부터 동물병원 방사선 관리제도가 시행됩니다

  • 대한수의사회
    • Journal of the korean veterinary medical association
    • /
    • v.47 no.3
    • /
    • pp.207-216
    • /
    • 2011
  • 2011년 1월 26일 관련 법규(동물 진단용 방사선발생장치의 안전관리에 관한규칙)가 제정되어 시행됨에 따라 X-ray, CT 등 방사선발생장치를 사용하려는 동물병원은 사용일 3일전까지 시 군 구청에 신고하여야 하며 사용기록을 작성하고 필요한 검사를 받아야 합니다.

  • PDF

A Study on Regulations Through Analysis of the Status of Radiation Workers and Related Workers and Satisfaction Survey in the Radiology Department (방사선작업종사자 및 방사선관계종사자의 현황 분석과 교내 실습 만족도 조사를 통한 방사선(학)과의 규제에 대한 고찰)

  • Jung, Hyunseo;Lee, Yong-Ki;Ahn, Sung-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.327-334
    • /
    • 2022
  • In this study, the purpose of this study was to conduct a basic study on the effectiveness and feasibility of the regulation of the Nuclear Safety Act for the department of radiology by examining the questionnaire on the satisfaction of on-campus practice while attending the department of radiology and the current status of radiation workers and radiation related workers. As for the satisfaction of the workers who were designated as frequent visitors while attending the department of radiology and did not handle and operate the radiation generator during on-campus training, 34.62% of the workers answered 'not satisfied'. On the other hand, 50% of workers who were designated as radiation workers while attending school or who were enrolled in school before the regulation of the nuclear safety act and handled and operated radiation generators were 'satisfied' at 50%. In addition, the annual exposure dose of radiation workers in educational institutions was found to be less than 0.05 mSv. If you look at the trends of radiation workers and radiation workers, it can be seen that students who graduate from the Department of Radiology find the most employment in the field dealing with diagnostic radiation generators registered as radiation workers among medical institutions. Therefore, by easing the regulations of the current Nuclear Safety Act or by amending the medical act and the rules on the safety management of diagnostic radiation generating devices, etc. It is presumed that something is necessary.

Research on the Actual Condition of the radiation Safety Management(RSM) for the Educated Training of the Dental Diagnostics X-ray Generators (교육용 치과 엑스선 발생장치에 대한 방사선 안전 관리 실태 조사)

  • Lee, Mihyeon;Yu, Yunsik;Lee, Jaeseung;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.7
    • /
    • pp.467-477
    • /
    • 2014
  • The purpose of this study is to offer data base for establishment of dental training x-ray generator based safety usage through surveying real radiation safety management state of radiation worker's in plan of operations that have dental training x-ray generators and use it. For it, comprehensive references were surveyed referring reports of current state of regulation technique development and domestic radiation safety evaluation and nuclear related legislation regarding radiation safety management of dental training x-ray generators. On the basis of it, questionnaires were filled in about respondent's general characteristic radiation safety manager's status current state of radiation safety management and the level of knowledge & consciousness. For the study, the survey was conducted to 224 people of radiation safety managers and university graduates training assistants and full-time professors who can treat dental training x-ray generators in education center. through this survey 95 questionnaires were used as analysis materials except the insufficient and omitted responses. As a method of analysis, the frequency and percentage were figured out with the general characteristics and safety manager's status. Chi-square test for frequency and correlation per question analysis and Pearson correlation analysis for crosslevel correlation were done with current state of radiation safety management and knowledge & consciousness level. As a result, running dental training x-ray generators was dealt with by 20's to 40's who have high education level over post undergraduate degree and major in dental hygienic. In addition, female have higher consciousness level for radiation safety management than male. It shows significal linear relation statistically(${\chi}^2$ >5, 0.1${\chi}^2$ >5, 0.3${\chi}^2$ >5, 0.3

The Improvement Plan on Unifying from Law and Regulations Related to Radiation (방사선관계법 개정 시 용어 적용에 관한 개선 방안)

  • Jeong, Dong-Kyong;Lee, Jong-Back;Park, Myeong-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.7-12
    • /
    • 2006
  • Purpose: This is for the purpose to help the bill related to technologists be systematic and unitary by carefully analyzing a legislation, an enforcement ordinance, and enforcement regulations in the connection with the radiological worker and the radiation workers from the law and regulations related to technologists. Materials and Methods: Concerning technologists, a legislation, an enforcement ordinance, and enforcement regulations for a sort of medical technician, regarding the radiological worker, the rules of diagnosis radiation equipment safety management, and concerning the radiation workers, atomic energy law, an enforcement ordinance and enforcement regulations were gathered, compared with one another, and analyzed. Results: Among technologists, in the case of working in the department of diagnosis radiation, the title 'Radiological Worker' is used by the Medical Service Law, and in the case of working in the department of radiation tumors or the one of nucleus medicine, the title 'Radiation Workers' is used by the Atomic Energy Law. Conclusion: Besides the technical term that is used by characteristic tasks, unification of the terms that can be used in common is necessary for sure. And when a legislation, an enforcement ordinance, enforcement regulations, and notification, things like that in the radiation field are amended, certainly they should be done by mutual agreement through negotiation between the organization related to radiation and the governmental organization.

  • PDF

Analyze dosimetry with and without shielding when amplifying scattered rays (산란선 증폭시 차폐체 유무에 따른 선량 분석)

  • Chang Ho Cho;Jeong Lae Kim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.3
    • /
    • pp.819-825
    • /
    • 2024
  • The reason for recording dose data when using a diagnostic radiation source is to record and manage the dose to healthcare personnel and patients. The purpose of this study was to verify the difference in radiation dose when using diagnostic radiation generating devices and to inform users' awareness of dose reduction through measurement and analysis of dose in situations with and without shielding. The dose analysis of each equipment for two Korean C-arms and two German C-arms showed that the Korean FPD type C-arm had the highest dose value, followed by the German I.I type C-arm, German FPD type C-arm, Korean, and I.I type C-arm. The results of the dose analysis with and without shielding showed that the dose to the human phantom in a normal atmosphere increased by about 2 times due to scattered radiation, but the dose to the human phantom was reduced by about 5 times by wearing a shield (0.5mm/lead apron). More important than the management of radiation dose is the study of how to reduce exposure when using radiation, and since the radiation dose output from different equipment is different, it is necessary to provide dose information with and without shielding.