• Title/Summary/Keyword: 진단영상기술

Search Result 646, Processing Time 0.033 seconds

Characterizing Strategy of Emotional sympathetic Robots in Animation and Movie - Focused on Appearance and Behavior tendency Analysis - (애니메이션 및 영화에 등장하는 정서교감형 로봇의 캐릭터라이징 전략 - 외형과 행동 경향성 분석을 중심으로 -)

  • Ryu, Beom-Yeol;Yang, Se-Hyeok
    • Cartoon and Animation Studies
    • /
    • s.48
    • /
    • pp.85-116
    • /
    • 2017
  • The purpose of this study is to analyze conditions that robots depicted in cinematographic works like animations or movies sympathize with and form an attachment with the nuclear person and organize characterizing strategies for emotional sympathetic robots. Along with the development of technology, the areas of artificial intelligence and robots are no longer considered to belong to science fiction but as realistic issues. Therefore, this author assumes that the expressive characteristics of emotional sympathetic robots created by cinematographic works should be used as meaningful factors in expressively embodying human-friendly service robots to be distributed widely afterwards, that is, in establishing the features of characters. To lay the grounds for it, this research has begun. As the subjects of analysis, this researcher has chosen robot characters whose emotional intimacy with the main person is clearly observed among those found in movies and animations produced after the 1920 when robot's contemporary concept was declared. Also, to understand robots' appearance and behavioral tendency, this study (1) has classified robots' external impressions into five types (human-like, cartoon, tool-like, artificial bring, pet or creature) and (2) has classified behavioral tendencies considered to be the outer embodiment of personality by using DiSC, the tool to diagnose behavioral patterns. Meanwhile, it has been observed that robots equipped with high emotional intimacy are all strongly independent about their duties and indicate great emotional acceptance. Therefore, 'influence' and 'Steadiness' types show great emotional acceptance, the influencing type tends to be highly independent, and the 'Conscientiousness' type tends to indicate less emotional acceptance and independency in general. Yet, according to the analysis on external impressions, appearance factors hardly have any significant relationship with emotional sympathy. It implies that regarding the conditions of robots equipped with great emotional sympathy, emotional sympathy grounded on communication exerts more crucial effects than first impression similarly to the process of forming interpersonal relationship in reality. Lastly, to study the characters of robots, it is absolutely needed to have consilient competence embracing different areas widely. This author also has felt that only with design factors or personality factors, it is hard to estimate robot characters and also analyze a vast amount of information demanded in sympathy with humans entirely. However, this researcher will end this thesis as the foundation for it expecting that the general artistic value of animations can be used preciously afterwards in developing robots that have to be studied interdisciplinarily.

Usefulness Evaluation of Open Mouth View when PET/CT scan In Tongue Cancer Patients (Tongue Cancer 환자에서 PET/CT 검사 시 Open Mouth 촬영법의 유용성 평가)

  • Kim, Jae Hwan;Yun, Jong Jun;Jung, Ji Wook;Kim, Jung Wook;Hwang, Ju Won;Ji, Hye In
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.14-20
    • /
    • 2016
  • Purpose Tongue cancer is 1.8% of all cancer tumors occur in the tongue, it is known that the high incidence enough to account for 75% of oral cancer conducted a PET / CT examination for early diagnosis, metastasis, staging, etc. and. Tongue when PET / CT scan of a cancer patient and a Torso taken to close mouth lesions if the condition was caused due to the overlapping or corresponding artifacts are not clearly observed. The purpose of this study is to evaluate the changes that occur during PET / CT scan with open mouth and its usefulness under. Materials and Methods From June 2015 to March 2016 complained of herein by May 21 had received a diagnosis of tongue cancer underwent PET / CT scan patients were treated with a target (16 males, 5 female). The first was taken to close mouth Torso state, it was taken to add 1 bed open mouth condition. Tumor (T), measuring the Normal Tongue (NT), Lymph Node (LN) standard intake coefficient by setting a region of interest in the (standardized uptake value, SUV) SUVmean, the average value was measured SUVmax, drawn to each region of interest 3 times and Background (Carotid artery) was out of the SUV. In Chapter 3 of the slice to the tumor clearly visible by setting the region of interest to measure the change Tumor size was calculated average value. Gross Image resolution assessment were analyzed statistically through were divided into 1-5 points by the Radiation 7 people in 2, more than five years worked in specialized nuclear medicine compare to proceed with the blind test nonparametric test (wilcoxon signed rank test). (SPSS ver.18) Results $SUV_{mean}$ T's were in close mouth $5.01{\pm}2.70$ with open mouth $5.48{\pm}2.88$ (P<0.05), $SUV_{max}$ were respectively $8.78{\pm}5.55$ and $9.70{\pm}5.99$ (P<0.05). $SUV_{mean}$ in the NT were respectively $0.43{\pm}0.30$ and $0.34{\pm}0.24$ (P=0.20), $SUV_{max}$ was $0.56{\pm}0.34$ and $0.45{\pm}0.25$ (P=0.204). LN $SUV_{mean}$ were respectively $1.62{\pm}1.43$ and $1.69{\pm}1.49$ (P=0.161), $SUV_{mean}$ was $2.09{\pm}1.88$ and $1.99{\pm}1.74$ (P=0.131). Tumor size change is close mouth $4.96{\pm}4.66cm^2$ $5.33{\pm}4.64cm^2$ with 7.45% increase was (P<0.05), gross image resolution evaluation is $2.87{\pm}0.73$, $3.77{\pm}0.68$ with open mouth examinations 30.5% increase was (P<0.05). Conclusion Tumor SUV on the changes that had an increase in open mouth during inspection, the normal tongue and lymph node, but there was no significant difference in the change slightly. It is also one open mouth PET / CT scan will provide improved image to all patients with tongue cancer, but it could be confirmed that similar overall through the blind test, or tumor size changes and showing a high resolution image. It can be the perfect alternative method for problems that occur when the close mouth Open mouth PET / CT scan, but is believed to be through the open mouth to observe the boundary of overlapping or tumor of the oral cavity other structures a little more clearly. Tongue cancer patients how to recommend that the shooting further open mouth PET / CT.

  • PDF

An Analysis of BMD Changes With Preoperative and Postoperative Premenopausal Breast Cancer Patient (폐경 전 유방암 환자의 치료 전.후 골밀도 변화 분석)

  • Kim, Su-Jin;Son, Soon-Yong;Choi, Kwan-Woo;Lee, Joo-Ah;Min, Jung-Whan;Kim, Hyun-Soo;Ma, Sang-Chull;Lee, Jong-Seok;Yoo, Beong-Gyu
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.279-286
    • /
    • 2014
  • The purpose of this study is to provide basic data of comparing BMD(bone mineral density) value of preoperative breast cancer patient and postoperative breast cancer patient due to bone loss with radiation/chemical therapy. The participants consisted of 254 breast cancer patients with BMD after having surgery and treatment from March 2007 to September 2013. Except for 84 patients with menopause or hysterectomy and we have analysed 171 patients. The BMD value(lumbar spine and femur) of before and after treatment from PACS by dure-energy X-ray absorptiometry was analyzed. First, we found variation of entire BMD and BMD according to treatment type, and analyzed detailed correlation by using marital status, number of children, presence of feeding, age of menarche, breast cancer therapy types as variable. Data was analyzed by using SPSS for Windows Program(version 18.0). BMD was decreased 7.1% in lumbar spine, 3.1% in femur respectively(p<.01). Also there is relatively high decrement($0.067g/cm^2$) in group who had just chemotherapy in femur(p<.05). There is decrement depend on marital status, number of children, presence of feeding, age of menarche, breast cancer therapy types but there was no statistical significance. The results show that BMD was decreased after treatment in premenopausal breast cancer patient, patient who had relatively high decrement need to be included high-risk group. As a result, aggressive prevention policy would be necessary.

Method to Reduce the Activity Loss and Pain when Injecting 18F-Florbetaben (18F-Florbetaben 주사 시 Activity 손실과 통증 감소를 위한 방법)

  • Kwon, Hyeong Jin;Choi, Jin Wook;Lee, Hyeong Jin;Woo, Jae Ryong;Kim, Yoo Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.42-45
    • /
    • 2016
  • Purpose Neuracep is used to other diagnostic evaluations of the brain to estimate beta-amyloid neuritic plaque density in adult patients with cognitive impairment and inspected cognitive impairment. $^{18}F-Florbetaben$ specially has moderate lipophilicity and property of the added ethanol. It is the subject of interest of the patient pain and residual activity after injecting. Our study is effective injection method of the radiopharmaceutical and patient care. So it is for the highest quality image. Materials and Methods Patients were targeted 70 subjects, it was injected mean $259{\pm}74MBq$ to the patients ($^{18}F-FDG$: 20 subjects, $^{18}F-FP-CIT$: 20 subjects, $^{18}F-Florbetaben$: 30 subjects). After injection (reflusing 2 times, reflusing 3 times) using a 3-way set, it measured the residual activity. When injecting $^{18}F-Florbetaben$, we evaluated the effective injection methods(3-way set method and heparin cap method). The average residual activity after the injection was compared using a statistical analysis of SPSS 12.0(ANOVA, t-test analysis). Also, elemental analysis was performed on $^{18}F-Florbetaben$ by GC (Gas Chromatography). Results When reflusing 2 times measured residual activity as follows ($^{18}F-FDG$: 1.48 MBq, $^{18}F-FP-CIT$: 7.4 MBq, $^{18}F-Florbetaben$: 32.6 MBq). And when reflusing 3 times measured residual activity as follows ($^{18}F-FDG$: 1.85 MBq, $^{18}F-FP-CIT$: 3.7 MBq, $^{18}F-Florbetaben$: 36.3 MBq). There was a significant difference when reflusing 2 times(P < 0.05) and reflusing 3 times (P < 0.05). But when reflusing 3 times, there was no significant difference relation FDG and FP-CIT (P > 0.05). $^{18}F-Florbetaben$ Residual activity according to the injection method was a significant difference (P < 0.05). GC analysis results were measured ethanol: 207665 ppm and acceton: 377.4 ppm. Conclusion $^{18}F-Florbetaben$ was high residual activity compared to FDG and FP-CIT. Heparin cap method was effective when $^{18}F-Florbetaben$ was injected. $^{18}F-Florbetaben's$ ethanol component analysis was highly measured. So it is recommended that inject to 6 sec/ml or more in order to reduce the pain.

  • PDF

Evaluation of Effective and Organ Dose Using PCXMC Program in DUKE Phantom and Added Filter for Computed Radiography System (CR 환경에서의 흉부촬영 시 Duke Phantom과 부가여과를 이용한 유효선량 및 장기선량 평가)

  • Kang, Byung-Sam;Park, Min-Joo;Kim, Seung-Chul
    • Journal of radiological science and technology
    • /
    • v.37 no.1
    • /
    • pp.7-14
    • /
    • 2014
  • By using a Chest Phantom(DUKE Phantom) focusing on dose reduction of diagnostic radiation field with the most use of artificial radiation, and attempt to reduce radiation dose studies technical radiation. Publisher of the main user of the X-ray Radiological technologists, Examine the effect of reducing the radiation dose to apply additional filtering of the X-ray generator. In order to understand the organ dose and effective dose by using the PC-Based Monte Carlo Program(PCXMC) Program, the patient receives, was carried out this research. In this experiment, by applying a complex filter using a copper and Al(aluminum,13) and filtered single of using only aluminum with the condition set, and measures the number of the disk of copper indicated by DUKE Phantom. The combination of the composite filtration and filtration of a single number of the disk of the copper is the same, with the PCXMC 2.0. Program looking combination of additional filtration fewest absorbed dose was calculated effective dose and organ dose. Although depends on the use mAs, The 80 kVp AP projection conditions, it is possible to reduce the effective amount of about 84 % from about 30 % to a maximum at least. The 120 kVp PA projection conditions, it is possible to reduce the effective amount of about 71 % from about 41 % to a maximum of at least. The organ dose, dose reduction rate was different in each organ, but it showed a decrease of dose rate of 30 % to up 100 % at least. Additional filtration was used on the imaging conditions throughout the study. There was no change in terms of video quality at low doses. It was found that using the DUKE Phantom and PCXMC 2.0 Program were suitable to calculate the effect of reducing the effective dose and organ dose.

An Electrical Conductivity Reconstruction for Evaluating Bone Mineral Density : Simulation (골 밀도 평가를 위한 뼈의 전기 전도도 재구성: 시뮬레이션)

  • 최민주;김민찬;강관석;최흥호
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.261-268
    • /
    • 2004
  • Osteoporosis is a clinical condition in which the amount of bone tissue is reduced and the likelihood of fracture is increased. It is known that the electrical property of the bone is related to its density, and, in particular, the electrical resistance of the bone decreases as the bone loss increases. This implies that the electrical property of bone may be an useful parameter to diagnose osteoporosis, provided that it can be readily measured. The study attempted to evaluate the electrical conductivity of bone using a technique of electrical impedance tomography (EIT). It nay not be easy in general to get an EIT for the bone due to the big difference (an order of 2) of electrical properties between the bone and the surrounding soft tissue. In the present study, we took an adaptive mesh regeneration technique originally developed for the detection of two phase boundaries and modified it to be able to reconstruct the electrical conductivity inside the boundary provided that the geometry of the boundary was given. Numerical simulation was carried out for a tibia phantom, circular cylindrical phantom (radius of 40 mm) inside of which there is an ellipsoidal homeogenous tibia bone (short and long radius are 17 mm and 15 mm, respectively) surrounded by the soft tissue. The bone was located in the 15 mm above from the center of the circular cross section of the phantom. The electrical conductivity of the soft tissue was set to be 4 mS/cm and varies from 0.01 to 1 ms/cm for the bone. The simulation considered measurement errors in order to look into its effects. The simulated results showed that, if the measurement error was maintained less than 5 %, the reconstructed electrical conductivity of the bone was within 10 % errors. The accuracy increased with the electrical conductivity of the bone, as expected. This indicates that the present technique provides more accurate information for osteoporotic bones. It should be noted that tile simulation is based on a simple two phase image for the bone and the surrounding soft tissue when its anatomical information is provided. Nevertheless, the study indicates the possibility that the EIT technique may be used as a new means to detect the bone loss leading to osteoporotic fractures.

The Assessment of Scattered Ray According to the Beam Thickness of Z-axis in MDCT(Multi Detector Computed Tomography) (MDCT(다배열검출기 전산화단층촬영장치)에서 Z-축의 빔 두께에 따른 산란선의 평가)

  • Ryu, Gwi-Bok;Kim, Hyun-Soo;Lyu, Kwang-Yeul;Dong, Kyung-Rae;Kweon, Dae-Cheol
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.127-132
    • /
    • 2010
  • The purpose of this study is to measure scattered ray which is occurred except for Z-axis range of the detector in MDCT's iso-center and present the basic data about the standard for reduction of scattered ray. The development of MDCT brings out the enlargement of beam thickness to the patient's Z-axis, which distributes to the increase in exposure dose according to the rise of scattered ray. Also MDCT brings out the increase of scattered ray about 4times more than SDCT. To evaluate scattered ray according to the change of beam thickness on MDCT, we measured scattered ray of MDCT's Z-axis beam thickness by using one 16-slice CTs and two 64-slice CTs. We used the ionization chamber 60ml 2026C as the equipment of measurement. In our results, we found out that the change of scattered ray according to the beam thickness in the same kVp has increase of scattered ray. Secondly we found out the increase of scattered ray according to the increase of kVp. Lastly we found out the decrease of scattered ray according to the increase of the distance from the ionization chamber.

The Position for Measuring BMD of the Distal Radius and The Study of the Correlation Between the Distal Radius and Lumba (원위 요골 골밀도의 측정 자세 및 요추 골밀도의 상관관계에 관한 연구)

  • Han, Man-Seok;Jeon, Chul-Min;Kim, Jong-Jin;Seo, Seon-Youl;Kim, Yong-Kyun
    • Journal of radiological science and technology
    • /
    • v.33 no.1
    • /
    • pp.19-24
    • /
    • 2010
  • The aim of this study was to evaluate the change of bone mineral density according to distal radius rotation and the correlations of the lowest BMD measured by DXA at the lumba versus distal radius. The eleven males were projected distal radius by DR X-ray and the measurement of BMD by DXA of the appropriate position of the forearm were performed on 21 males. The healthy 11 and 21 volunteers without any history of operations, anomalies, or trauma were enrolled. The experiment was performed by two methods. First, The DR X-ray was measured distal radius of 11 males in pronation and supination with three, six and nine degrees, including a neutral position. The ROI was measured by the m-view program on the PACS monitor. Second, The DXA was measured distal radius of 21 males in pronation and supination with five and ten degrees, including a neutral position to evaluate the changes of BMD according to the rotation. A correlation of the BMD in the distal radius with BMD that lumbar spine was performed, along with analysis of the data by SPSS 12.0v. The mean rotation angle of the distal radius about eleven males DR X-ray measured $7^{\circ}$ of pronation (82%, n = 9), $6^{\circ}$ of supination and $0^{\circ}$ of neutral of (9%, n = 1), The total average rotation angle in 11 male was $5.1^{\circ}$ of pronation. The rotation angle of the distal radius about twenty one males on DXA measured $7.2^{\circ}$ of pronation (43%, n = 9), $7^{\circ}$ of supination (24%, n = 5), and $0^{\circ}$ of neutral (33%, n = 7), The total average rotation angle in 21 people was $4.1^{\circ}$ of pronation. The correlation of the analysis of lumba and distal radius were r = 3.0, p = 0.18. consequently, The correlation was not significance. Because BMD of lumba was not coverd for BMD of the distal radius, with a neutral position, Pronation is needed for BMD in the distal radius with the rotation angle measuring at the lowest BMD. the rotation angle about five degrees of pronation of the distal radius is recommended.

Effect of MRI Media Contrast on PET/MRI (PET/MRI에 있어 MRI 조영제가 PET에 미치는 영향)

  • Kim, Jae Il;Kim, In Soo;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.19-25
    • /
    • 2014
  • Purpose: Integrated PET/MRI has been developed recently has become a lot of help to the point oncologic, neological, cardiological nuclear medicine. By using this PET/MRI, a ${\mu}-map$ is created some special MRI sequence which may be divided parts of the body for attenuation correction. However, because an MRI contrast agent is necessary in order to obtain an more MRI information, we will evaluate to see an effect of SUV on PET image that corrected attenuation by MRI with contrast agent. Materials and Methods: As PET/MRI machine, Biograph mMR (Siemens, Germany) was used. For phantom test, 1mCi $^{18}F-FDG$ was injected in cylinderical uniformity phantom, and then acquire PET data about 10 minutes with VIBE-DIXON, UTE MRI sequence image for attenuation correction. T1 weighted contrast media, 4 cc DOTAREM (GUERBET, FRANCE) was injected in a same phatnom, and then PET data, MRI data were acquired by same methodes. Using this PET, non-contrast MRI and contrast MRI, it was reconstructed attenuation correction PET image, in which we evanuated the difference of SUVs. Additionally, for let a high desity of contrast media, 500 cc 2 plastic bottles were used. We injected $^{18}F-FDG$ with 5 cc DOTAREM in first bottle. At second bottle, only $^{18}F-FDG$ was injected. and then we evaluated a SUVs reconstructed by same methods. For clinical patient study, rectal caner-pancreas cancer patients were selected. we evaluated SUVs of PET image corrected attenuastion by contrast weighted MRI and non-contrast MRI. Results: For a phantom study, although VIBE DIXON MRI signal with contrast media is 433% higher than non-contrast media MRI, the signals intensity of ${\mu}-map$, attenuation corrected PET are same together. In case of high contrast media density, image distortion is appeared on ${\mu}-map$ and PET images. For clinical a patient study, VIBE DIXON MRI signal on lesion portion is increased in 495% by using DOTAREM. But there are no significant differences at ${\mu}-map$, non AC PET, AC-PET image whether using contrast media or not. In case of whole body PET/MRI study, %diff between contras and non contrast MRAC at lung, liver, renal cortex, femoral head, myocardium, bladder, muscle are -4.32%, -2.48%, -8.05%, -3.14%, 2.30%, 1.53%, 6.49% at each other. Conclusion: In integrated PET/MRI, a segmentation ${\mu}-map$ method is used for correcting attenuation of PET signal. although MRI signal for attenuation correciton change by using contrast media, ${\mu}-map$ will not change, and then MRAC PET signal will not change too. Therefore, MRI contrast media dose not affect for attenuation correction PET. As well, not only When we make a flow of PET/MRI protocol, order of PET and MRI sequence dose not matter, but It's possible to compare PET images before and after contrast agent injection.

  • PDF

Ultrasonography findings on thyroid nodule with no clinical symptom (임상적 증상이 없는 갑상선 결절에 대한 초음파영상 소견)

  • Kim, Wha-Sun
    • Journal of radiological science and technology
    • /
    • v.28 no.3
    • /
    • pp.211-217
    • /
    • 2005
  • This study obtained the following conclusions by analyzing whether or not thyroid nodule, the number of nodules depending on age and gender, and the developed site of nodule, targeting 838 persons in their 30s-70s who were conducted the thyroid ultrasonography, without clinical symptoms, at the Health Promotion Center. 1. As for the general characteristics of 838 research subjects, men were 368 persons(44%), and women were 470 persons (56%), and the mean age was 51. 2. Among 838 whole subjects, a case, which was diagnosed to be normal, was 590 persons(70%), and persons with nodules findings were 248 persons (30%), thus it was indicated 30% on an average in having the thyroid nodules findings. 3. As for the frequency by age level in thyroid nodule, it was represented men with 10%-14% and women with $20{\sim}29%$ in their $30{\sim}40s$, and men with $27{\sim}33%$ and women with 37-52% in their 50-60s, and men with 46% and women with 50% in their 70s. 4. As a result of obtaining 248 persons, who have thyroid nodules findings, with the solitary nodule and the multiple nodule, it was indicated the solitary nodule of 50.5% with 125 persons and the multiple nodule of 49.5%, thereby representing the almost same ratio. 5. As for the size of thyroid nodule, the majority in all the age levels had the nodule in small size, and the size of $1{\sim}10\;mm$ was largest with 187 persons (75%) among 248 persons with abnormal findings, and it was 45 persons (18%) in $11{\sim}20\;mm$, 14 persons (5.6%) in $21{\sim}30\;mm$, and 2 persons in more than 31 mm. 6. As for the anatomically developed site in nodule, it was indicated the right lobe with 93 persons (38%), the left lobe with 67 persons (27%), both lobes with 75 persons (30%), and isthmus with 13 persons (5.3%), thereby representing the largest frequency in the right lobe, and it was discovered less in isthmus.

  • PDF