• Title/Summary/Keyword: 지하수오염

Search Result 1,731, Processing Time 0.027 seconds

Assessment of Regional Groundwater Pollution Hazard using Potential Pollutant of Pohang Area (잠재오염원을 이용한 포항지역의 광역적 지하수 오염 위험성 평가)

  • Lee, Sa-Ro;Kim, Yong-Seong;Kim, Deuk-Geun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.9 no.3
    • /
    • pp.1-13
    • /
    • 2006
  • The aim of the study is to assess groundwater pollution hazard of Pohang city using the DRASTIC system developed by the US Environmental Protection Agency (USEPA). Hydrogeological spatial databases of the system include information on depth to groundwater, net recharge, aquifer media, soil media, topographic slope, hydraulic conductivity, lineament and potential pollution source. With GIS based on these hydrogeological databases and the DRASTIC system, the regional groundwater vulnerability of the study area was assessed. Then the vulnerability was overlaid with potential pollution source and the regional groundwater pollution hazard was assessed by administrative district. From the results of the study, areas where need the counter plan for groundwater pollution and where should be managed for the groundwater pollution, are identified.

  • PDF

팩카그라우팅 공법을 이용한 지표하부 오염방지 시공 및 응용 연구

  • 조희남;성익환;이병대;조병욱
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.77-81
    • /
    • 2003
  • 일반세균, 질산성질소, 탁도로 오염된 지하수 관정의 2개공에 대해 수질개선을 시행하였다. 그 결과 2개공 모두 음용수 기준에 적합한 수질개선 효과를 가질 수 있음으로 하여 수질오염 발생의 주요 요인 중의 하나가 지하수 지표하부 오염방지 시설인 그라우팅이 부실함으로써 기인함을 규명할 수 있었다. 따라서, 본 연구를 통해 수질이 오염된 지하수 관정의 수질개선이 가능하다는 확인은 물론 또한, 지하수 관정내 지표수의 유입을 방지하기 위해서 지하수 상부오염방지 시설의 설치가 적극적으로 추진되어야 할 것이다. 지하수 오염을 예방하기 위해서는 지하수 개발 단계에서부터 지하수 지표하부 오염방지 시설이 연암 암반층까지 견실하게 적용되어져야 한다는 것을 확인할 수 있었다.

  • PDF

The recent trend of the soil and groundwater environment policy and the role of geophysical exploration technology (최근의 토양${\cdot}$지하수환경 정책동향과 물리탐사기술의 발전과제)

  • Kim Young-Woong
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2000.09a
    • /
    • pp.5-18
    • /
    • 2000
  • 토양${\cdot}$지하수환경분야와 관련된 제도들이 최근 개정 움직임을 보이고 있는 시점에서 조사단계 및 처리단계이후의 유지관리분야에서 지구물리탐사분야의 중요성이 점차 인식되고 있다. 특히 토양${\cdot}$지하수오염과 관련하여 오염유발가능시설의 $80\%$가 농촌지역에 산재되어 있으나, 그 규모와 오염정도에 대한 조사가 제대로 이루어지지 않은 상태이다. 이에 따라 지하수의 수질은 점차적으로 저질화 되어가고 있으나 비가시적인 이유로 인하여 그동안 소홀히 다루어져 왔다. 또한 오염조사 및 오염복원 등이 제도적으로 뿌리내리지 못해 오염원의 범위, 정도 등을 확인하는데 많은 한계점을 드러내고 있는 현실이다. 최근 관계법령의 개정을 통해 보다 엄격하고 강화된 규제 및 책임을 법제화하는 일은 현재와 미래의 환경보전을 위해 다행한 일이라 하겠다. 특히, 지하수오염 등은 국가적인 불행한 일이므로 향후 토양${\cdot}$지하수환경에 막대한 영향을 미칠 오염인자에 대한 정밀실태조사가 시급히 이루어져야 할 것이다. 따라서 현재 개정을 추진하고 있는 토양환경보전법과 지하수법의 개정취지를 제대로 살리면서 환경오염에 능동적으로 대처하기 위하여 지구물리탐사분야와 지질조사분야에서의 다양하고 정밀한 조사를 위한 방법들과 내용에 대한 연구가 절실히 요구되고 있다. 또한 이와 더불어 오염부지 특성조사를 위한 절차 및 방법들이 구체적으로 법제화되어 할 것이다.

  • PDF

공장부지 토양.지하수 오염 조사기법 및 정화기술의 적용

  • 황종식;박연정;손명기
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1998.11a
    • /
    • pp.19-26
    • /
    • 1998
  • 토양과 지하수 오염은 오염원이나 그 정화 방법에 있어서 서로 밀접한 관계를 가지고 있으며, 수질오염이나 대기오염과 달리 일단 한번 오염이 되면 오염 정화과정이 매우 복잡하고 어려우면서도 비용이 많이 드는 특성을 갖고 있기 때문에 오염원의 형태에 따른 통합된 관리 및 효율적 정화기술의 적용이 무엇보다 필요하다. 따라서 표준화된 오염조사 절차 (Environmental Site Assessment)를 통해 대상부지를 조사한 후, 확인된 오염원의 정화를 위한 기술을 선정함에 있어 필요한, 오염원·대상부지 특성 및 사업환경에 따른 정화기술에 대해 설명하고, 토양 및 지하수 통합 정화기술의 적용 예를 들어 토양과 지하수를 통합·관리함이 필요함을 살펴보고자 한다.

  • PDF

염소계유기용제 및 유류물질에 의한 산업단지 지하수 오염특성

  • Kim Jong-Ho;Kim Rak-Hyeon;Ryu Gwan-Hui;Park Jeong-Gu;Seo Chang-Il;Jeon Gwon-Ho;Jeong Jang-Sik
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.355-359
    • /
    • 2006
  • 토양에 누적된 오염물질은 지하수 유동과 연계하여 점차 주변지역으로 확산된다. 본 조사는 오염의 개연성이 높은 산업단지를 선정하고 그 중에서도 유해화학물질의 사용이 많은 지역을 대상으로 토양과 지하수의 오염도조사를 수행하였다. 토양오염도 조사는 160개 지점에서 토양시료를 채취하여 오염물질을 분석하였으며 분석결과 TPH물질은 최고 23,151mg/kg, BTEX는 최고 1,657mg/kg로 검출되었다. 오염특성은 유류(TPH, BTEX) 물질 이외에도 TCE, PCE◎물질과같은 염소계 유기용제에 의한 오염도 확인할 수 있었으나 중금속 물질에 의한 오염은 우수 방류구와 같은 일부 지역에서 검출되었다. 지하수 수질의 경우 페놀, 비소, 납, BTEX, TCE, PCE 물질들이 복합적으로 오염되어있는 것으로 나타났다.

  • PDF

Study of securing safe groundwater for water quality management (지하수 수질관리를 위한 안심지하수 연구)

  • Lee, Chung-Mo;Hamm, Se-Yeong;Jeon, Hang-Tak;Lim, Woo-Ri
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.454-454
    • /
    • 2017
  • 국내 상수도가 보급되지 않은 지역 내 취약 계층은 약 214만 명으로 대부분은 노후관정 및 미신고 관정에서 지하수를 먹는물로 이용하고 있다. 이들은 대부분 미신고 관정이기 때문에 실태파악이 어렵고 정기적인 수질 검사를 실시하지 않아 수질상태에 대한 안전 대책이 미흡한 실정이다. 우리나라의 경우 농촌지역의 관정은 천부지하수의 의존도가 크고 강우에 의한 지표오염물질(축산분뇨, 비료 등)이 관정 내부로 유입 가능성이 매우 높다. 기존 연구에서도 천부지하수 관정의 조사 결과, 질산성질소 및 총대장균군에 의한 수질 오염이 심각하다고 보고된다(Chae et al., 2004; Min et al., 2003). 따라서 상수도 미보급지역 지하수 관정의 지하수 수질 현황을 파악하고, 고농도 오염 관정 및 지역의 경우 정밀조사를 통해 오염 원인을 규명해야 한다. 또한 오염 원인에 대한 향후 개선방안 및 대책안을 마련하여 지하수 수질 안정성 확보를 도모할 필요가 있다. 이를 위해 환경부 산하 국립환경과학원에서는 안심지하수 지원 사업을 2012년 "지하수 안심이용 무료 수질검사 시범사업"부터 시작하여 2016년 "상수도 미보급지역 2016년 안심지하수 지원사업 연구"로 이어지며 수행하였다. 이 사업은 수질분석, 관정내부 탐사, 마을 공용 음용관정 설치지원, 고농도 오염지역 중 시범사업 지역 선정, 고농도 오염지역 수질개선 시범사업으로 구성된다. 수질 분석은 2012년 TA군 내 8개 읍 면의 1,200개 관정, 2013년 경기 북동부권 8개 시 군 11,861개 관정, 2014년 전국 14,494개 관정, 2015년 전국 25,900 관정, 2016년 전국 25,914 관정에 대해 수질 분석을 실시하였다. 수질분석 결과를 바탕으로 고농도 오염지역의 지하수 관정 내부 탐사를 실시하여 소유주에게 주변 환경 개선 조치 및 대민 지원(마을 공용 음용관정 설치)을 수행하고, 시범조사 대상지역을 선정하여 오염지역의 오염원 현황, 수질조사, 지하수 유동 모델링을 실시하여 오염 원인을 파악하였다. 추가로 2014년에는 안심지하수 수질보전 연구로드맵을 작성하여 환경부에 제시하였고, 2015년은 수질개선 사업에 대한 경제성 분석, 수질자료 DB 구축이 완료되었다.

  • PDF

An Assessment of Groundwater Contamination Vulnerability and Priority Areas for Groundwater Management Using GIS and Analytic Hierarchy Process (GIS 및 계층분석법을 이용한 지하수 오염 취약성 평가 및 관리 우선 대상 지역 평가)

  • LEE, Moung-Jin;HYUN, Yun-Jung;HWANG, Sang-Il
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.18 no.3
    • /
    • pp.35-51
    • /
    • 2015
  • The purpose of this study is to improve the previous groundwater contamination vulnerability assessment method, apply it to the study area, and select priority areas for groundwater management based on the quantitative analysis of groundwater contamination vulnerability. For this purpose, first, the previous 'potential contamination' based on groundwater contamination vulnerability assessment method was upgraded to the methodology considering 'adaptation capacity' which reduced contamination. Second, the weight of groundwater contamination vulnerability assessment factors was calculated based on the analytical hierarchy process(AHP) and the result of survey targeting groundwater experts. Third, Gyeonggi-do was selected as the study area and the improved methodology and weight were implemented with GIS and actual groundwater contamination vulnerability assessment was carried out. Fourth, the priority area for groundwater contamination management was selected based on the quantitative groundwater contamination vulnerability assessment diagram. The improved detailed groundwater contamination vulnerability assessment factors in this study were a total of 15 factors, and 15 factors were analyzed as new and improved weight with higher 'adaptation capacity' than the assessment factor corresponding to the previous 'potential contamination' in the weight calculation result using AHP. Also, the result of groundwater contamination vulnerability assessment in Gyeonggi Province using GIS showed that Goyang and Gwangmyeong which were adjacent to Seoul had a high groundwater contamination vulnerability and Pocheon and Yangpyeong County had a relatively low groundwater contamination vulnerability. In this study, the previous groundwater contamination vulnerability assessment was improved and applied to study areas actually. The result of this study can be utilized both directly and indirectly for the groundwater management master plan at national and local government level in the future.

오염방지 시설을 이용한 지하수 환경성 복원 연구

  • 이병대;조병욱;성익환;함세영;정상용;윤성택
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.155-158
    • /
    • 2002
  • 질산성질소 및 탁도로 오염된 지하수공에 대하여 환경성 복원을 위한 오염방지 시설을 시범 설치하였다. 지하수공에 대한 오염 정도를 조사한 결과 PS-1, CW-1, 그리고 CW-2 공이 질산성질소로 오염되어 먹는물 수질기준을 초과하였고, CW-3 공은 탁도가 먹는물 수질기준을 초과하였다. 오염원은 지하수공 개발시 수량 확보를 위하여 그라우팅을 제대로 하지 않은 불량시공으로 인한 오염된 지표수의 유입으로 기인되었다. 금번 연구는 오염된 지하수의 환경성 복원을 위한 것으로, 오염원과 지하수를 격리시켜 오염물질의 지하수 내 유입을 방지할 수 있도록 패커 그라우팅을 완벽하게 다시 실시하였으며, 오염방지시설을 설치하였다. 이 연구를 위하여 먼저 대수층의 분포 및 특성팍악, 지하수공내 지표수의 유입구간 규명, 지하수 오염원, 오염실태, 오염경로 등을 파악하였다 오염방지시설을 설치한 후, 설치 전,후의 질산성질소와 탁도의 함량을 비교하기 위하여 수질 분석을 실시하였다. PS-1의 경우, 오염방지시설 설치전의 질산성질소 함량은 16.1 mg/L 이었으나, 설치후에는 8.1 mg/L, 7.9 mg/L로써 설치전에 비하여 51% 감소되었으며, CW-1은 10.3 mg/L에서 6.3mg/L으로 39%, 그리고 CW-2는 14.9 mg/L에서 9.0 mg/L 으로 40% 감소되었다. CW-3 공의 탁도는 157 NTU에서 0.97 NTU로 완벽하게 복원되었다.

  • PDF

차폐팩커(protection packer)를 이용한 지하수 심정의 역주입 상향식 그라우팅 방법 연구

  • 조희남;임승태
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.106-109
    • /
    • 2004
  • 지표하부 상층 오염지하수의 침투로 인한 암반 지하수의 오염을 방지하기 위하여 지하수 개발과정에서 반드시 지표하부 지하수 오염방지를 이행하도록 지하수법에 규정하고 있다. 널리 알려진 지표하부 오염방지 공법으로서는 팩카그라우팅 공법(packer Grouting Method), 트레미공법(Tremie Method)과 브레든 헤드 공법(Bradenhead Method)이 있다. 그러나, 현재 대다수의 지하수 개발 현장에서는 단순히 강관을 굴착공에 억지박음함으로써 지표하부 오염방지에 가름하는 사례가 다반사이며 깊은 심도의 경우에도 종래 공법으로는 한계를 가질 수밖에 없는 실정이었다. 따라서, 본 연구에서는 차폐 팩카(Protection Packer)를 이용하여 고, 저심도의 어느 지하수 심정에서나 용이하게 역주입 상향그라우팅이 가능한 여건이 될 수 있도록 시공 사례를 통해 연구를 수행하였다.

  • PDF

Groundwater Contamination at the Seokdae Waste Landfill Area of Pusan City (부산 석대 폐기물 매립장 일대의 지하수 오염)

  • 정상용
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.2 no.1
    • /
    • pp.1-8
    • /
    • 1995
  • Wastes produce groundwater contamination, offensive odor, and hazardous gases. This study investigates the contamination of groundwater at the Seokdae waste landfill area and seeks the desirable ways to minimize the groundwater contamination. Groundwater levels, water chemistry and aquifer characteristics of wells were examined around the Seokdae waste landfill. The water chemistry of the Dong stream, the groundwater distribution and flow were also studied. The results of this research show that the estimated quantity of the percolation from the landfill base to the ground is 520 ㎥/day and the extent of groundwater contamination is about 1-1.5 km from the center of the waste landfill. The groundwater contains heavy metals and other toxic elements. The conservation and management of the groundwater of the waste landfill need several monitoring wells to check the quantity and quality of groundwater, pumping wells to extract the contaminated groundwater, and slurry walls to protect the movement of contaminated groundwater.

  • PDF